HomeMy WebLinkAboutCHUGACH PARK ESTATES BLK 4 LT 1 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP211156 Work Type: Septic Initial Tax Code Number: 05148121000 Site Legal Address: CHUGACH PARK ESTATES BLK 4 LT 1 G:1161 Site Mailing Address: 19451 SULLINS DR, Chugiak Owner: KOLSTEDT JAMES & AMANDA Design Engineer: PANNONE ENGINEERING SERVICES This permit is for the construction of: Effective Date Expiration Date t S G o� Q` n v t�epartment Lot Size in Sq Ft: Total Bedrooms: 6/1/2021 6/1/2022 55444 Q Disposal Field 2 Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: Issued By: Date: Date: 3 MUNIUPALITY OF ANCHORAGE 03 - ---- Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 051-481-21 Property owner(s) James & Amanda Kolstedt Mailing address Site address 19451 Sullins Drive Day phone Legal description (Sub'd., Block & Lot) Chugach Park Estates Block 4 Lot 1 Legal description (Township, Range & Section) Lot Size 55,444 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field X❑ Initial FX -1 Single Family (SF) X❑ (w/wo ADU) Septic Tank MUpgrade ❑ (D) ❑ Holding Tank ❑ RenewalDuplex ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: t 5cjS Waiver Fees: Date of Payment:r '/�'( �% Date of Payment: Receipt Number: 06 %8Z ,2 Receipt Number: Permit No. —0-c-7 19Z I I 156 Waiver No. Permit App_ -'- :-:'-.,:c Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211156, Deb Wockenfuss, 06/01/21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211156, Deb Wockenfuss, 06/01/21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211156, Deb Wockenfuss, 06/01/21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211156, Deb Wockenfuss, 06/01/21 RcTERR P'i;��.� ERRA CONSULTING, INC 212 E. 51St Ave, Anchorage, AK. 99503 Office (907) 868-3791, Fax (907) 868-3793 yfR, 09577 Al' SOILS PERCOLATION TEST Performed for: Jason Nixa Date Performed: 8/18/15 ' .._..-' rO;' A �_) r4qT H Project: Chugach Park Est. B4, L1 TEST HOLE /f TH 15-1 Depth 18- 19- 20- Org/OL SW trace of silt B.O.H. — occ cobbles bottom 2' HOLE PRE-SOAKED PRIOR TO TEST KE;NNL•" FUS a Air SEE ATTACHED SITE PLAN FOR HOLE LOCATION Was Ground water encountered.? NO What depth? NA Depth to water after monitoring? NO - Dry Date? 9/1/2015 Reading Date Gross Time Net Time Depth to Water Net Drop 1 9/1/15 1:00 - 6" - 2 1:10 10 min 4/16" 5 12/16" 3 * 1:11 - 6" - 4 1:2I 10 min 3/16" 5 13/16" 5 * 1:22 - 6" - 6 1:32 10 min 4/16" 5 12/16" 7 * 1:33 - 6" - 8 1:43 10 min 6/16" 5 10/16" 9 * 1:44 - 6" - 10 1:54 10 min 6/16" 5 10/16" 11 * 1:55 - 6" - 12 2:05 10 min 6/16" 5 10/16" * Water Added Percolation Rate 1.8 (min/in) Perc Hole Diameter 6" Test Run Between 5 feet and 6 feet 1, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in effect on this date. Al ra ._ 9 So .....� . 'oK, upon JAW t 4 w _ � _ � ..._ .. _.. L �. .... _............. �._......,..... ...._......m & x e Wa..� e. .,.,...,m,> 6 . rte. �''•F..� ..... _ .,..- w y J ..... ..,,ee ... A Fromm Ft, �r��. �' �.. A, a � � y � � � � ,,,.�_ ... _...��. L Ft. tFt' „_ Rick Mystrom, Mayor Mmdcipali of_Anchor e Department of Health and Human Services 825 "L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 http://www.ci.anchorage.ak.us 343-4744 March 3, 1998 Curtis R & Kristina M Cherrier PO Box 200527 Anchorage, Alaska 99520 0527 Subject: Lot 1 Block 4 Chugach Park Estates Subdivision Permit #SW970023, PID #051-481-21 The subject permit, issued February 20, 1997 by this office for a single family well and/or on-site wastewater system, has expired as of February 20, 1998. A new permit must be obtained from this office for a well and/or on-site wastewater system NOT installed by the expiration date. If you have drilled the well, a well log must be sent to this office for documentation of the installation and to close the permit. If a licensed Professional Engineer has inspected the installation of the on-site wastewater system, the original as-built inspection report must be sent to this office for review, approval and documentation. All inspection reports must be submitted within 30 days of construction completion. When applying for a new permit, the fees are: $320.00 for an on-site wastewater permit; $120.00 for a well permit and $440.00 for a combined on-site wastewater and well permit. If you have any questions, please call this office at 343-4744. /,~-fh~rely, ~ On-site Services enc: Copy of Permit cc: S & S Engineering COPY' PAGE 1 OF 1 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW970023 DESIGN ENGINEER:S & S ENGINEERING OWNER NAME:CURTIS CHERRIER OWNER ADDRESS:2436 GLENHOOD DR. ANCHORAGE, AK. 99508 DATE ISSUED: 2/20/97 EXPIRATION DATE: 2/20/98 PARCEL ID:05148121 LEGAL DESCRIPTION: CHUGACH PARK ESTATES BLK 4 LT 1 LOT SIZE: 55444 (SQ. FT.) NUMBER OF BEDROOMS: 4 THIS PERMIT: THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) A_ND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: 1.) ENSURE A MINIMUM SETBACK DISTANCE OF 50 FT. BETWEEN THE ABSORPTION TRENCH AND ANY DOWN HILL CUTBANK. 2. ) INSTALL ABSORPTION TRENCH PARALLEL TO THE CONTOUR LINES OF THE ~~~ Z R .C ,IV ,DBY: . DATE: DATE: ROBERT C. COWAN, RE. ROBERTA. SHAFER, RE. HEALTH AUTHORITY APPROVALS SEWER & WATER MAIN EXTENSIONS SEWER & WATER INSPECTION ENGINEERING STUDIES AND REPORTS WELL INSPECTION & FLOW TEST SITE PLANS ROAD DESIGN SOILTEST PERCOLATION TEST STRUCTURAL & MECHANICAL INSPECTIONS ON SITE WASTEWATER DISPOSAL SYSTEM DESIGN January 9, 1997 CIVIL ENGINEERS (907) 694-2979 FAX (907) 694-1211 MUNICIPALITY OF ANCHORAGE Department of Health and Human Services P.O. Box 196650 Anchorage, AK. 99519 REFERENCE: Lot 1, Block 4, Chugach Park Estates Request you issue a permit to drill a well and install a septic system to serve the proposed four bedroom house on the referenced property. A test hole was excavated and a percolation test performed. The approximate location of the test hole is located on the attached site plan. At the time of excavation no water was encountered in the test hole and after seven day ground water monitoring, the monitoring tube was found to be dry. This property has enough area for a future septic upgrade which can be seen on the attached site plan. We do not anticipate any adverse effects on neighboring wells, septic systems or drainage patterns by the installation of the proposed septic system. If you require additional information, please contact us. Sincerely, Robert C. Cowan, P.E. RCC/gk Enclosure 17034 NORTH EAGLE RIVER LOOP · SUITE 204 · EAGLE RIVER, ALASKA 99577 1" ! - 60' SITE BGALE I-- PLAN DESIGN 1-- r- Municipality o! Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST FERFORMED FOR: LEGAL DESCRIPTION: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2O '~,,,,'.... DATE PERFORME6:'~ Township, Range, Section: ;LOPE WAS GROUND WATER ENCOUNTERED? s IF YES, AT WHAT St L DEPTH? ~ pO E Depth to Water AIt§r MonitorinD7 ~ ir~V SITE PLAN Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE ~ (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN ~' ET AND ? FT COMMENTS $ & S ENGINEERING , _, PERFORMED BY: I CERTIFY THAT THIS TEST WAS PERFORMED IN 17034 Eagle River Loop Road No. 204 ' ' c~/-'f/'~r/~7 ACCORDANCE WlEItI~I~T~i"~I~I~Ii4i~JI~'AL GUIDELINES IN EFFECT ON THIS DATE. DATE: 72-008 (Rev. 4/85)