HomeMy WebLinkAboutP & S LT 1 Municipality of Anchorage Page [ of DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: ~LV 9.?.C) lJrI5' PIDNumber: Name: JSf~C~ ~. PIERCE Wastewater System: [] New ~Upgrade ^ddress: ABSORPTION FIELD ,5'0o0 E. ~'2_ ~ AVE , ANCH ,flqS'/~'m NO. of Be.~ CO s: Phone: 3/"~(¢ - l,~'O'-~ ,~Deep Trench [] Shallow Trench [] Bed [] Mound [] Other LEGAL D ESCR I PTI O N .,,., Raling: O. 6 GPD/Sq. Ft. Tolal Depth from~ originalz. ~ grade: Lot: Block: Subdivision: Deplh Io pipe bottom Irom original grade: Gravel depth beneath pipe Township: ~ ~ Range: Section:~ ~ Fill added above original grade: Gravel lenglh: ~ 3 ~ O. ~ Ft. '~ Ft. Number of lines: Distance between lines: WELL: ~XiSTIN~New ~ Upgrade Gravelwidth: 2.~ Ft. J " ' Ft. Classification (Private. A.B,C): ~ ~otal Depth: Cased To: Total absorption area: Pipe material: FI. Ft. 7~0 SQ. Ft. Driller: Date Drilled: Static Water Level: Installer: Date in~talled: F~. CA~'S ExcAV~TI~G Sl~ ~ ~1~ Yield: GPM Pump Set at: Ft. Casing .eigh, Above Ground:F/. TAN K SEPARATION DISTANCES ~Septic ~ Holding B S.T.E.P. From ~ank Field Slation Tsn* S .... Lines ANClJOR~dE Iooo Well JO~ Jo~ ~ ~ ~ ~TEEL Surface Water >JOO' >/oo -- -- >1oo' LIFT STATION Lot I ~ Size in gallons: Manufacturer: Line J~ 2 ~ ~ ~O~ OI ~OI ~ ~ O I "Pump on" level al: "Pump off" level at: J High water alarm at: Foundation 5 CurtainDrain ~ .... Pump Make & Model Eleclrical Inspections performed by: ~ sr~-~ ,~/~-~ ~ ~'~--~ BENCH MARK Remarks: ~~ ~;~o, ~.~/~/ C~I~ ~C'~ ~ ~ ~F~~ /,~ ~E ~ Location and Description: ~ t)~ ~ ~ot~ ~U ~ ~ t~ ~. Assumed Elevation: ~ h--~ n~? ¢¢*/ ~'"¢ ~.e ~.z ~ >.,~ Fl~to~ Technical Servic~ ENGINEER'S SEAL refitted,,/ ~y~k~-, ~/ .... ~ I°~, ~chomge, A]ask~ 99516 ~.: 49 Inspections performed by: ~Z~9~ ~ 5F~.5_ .... Dates: 1st S/~)~ Department of Health__and Human Services approval Reviewed and approved by: ~ Date: ~-/~- ~ 72-013 (Rev. 9/91) MOA 25 PermitNo. 51,v' q2©L~l~- Page of Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Legal Description: LoT I ~' ~- <5 PID No.: I/:3 O O 72-013 A (Rev. 9/91) MOA 25 IOOO r~A L 5~c PT~C 'TANk C.o. '015T/tNC£g A B TANK C,o?~ $1' 33 ENCI~ C.O, H oo SE Flattop Technical Services 14530 Echo Street Anchorage, ,~dc~skct 9951g Permit I~1o. ~ L,/ cj 2 © ¢r 15- Page -~ of :~ Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Legal Description: ~-CT I 'j:) 4- ~ PID No.: _O looo ~Ac SEPTIC TA~k U, tVEP,.T ELEV: iNLET *13.%' / D)$T. Pi PE INVERT EI, gV,/ BOTH EM'b5 BOTTOt~ oF Te~C~/ f~$,7 ~ pl(~ttop Techniccd Services 14530 Echo Street Anchorage, Alr~sl¢c[ 99516 'PRY 3o 31--.-~. 72-013 A (Rev. 9/91) MOA 25 Tom Fink, Mayor MuniCipality of Ancl orage Department of Health and Human Services 825 "L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 August 20, 1993 Ted Moore, P.E. Flattop Technical Services 14530 Echo Street Anchorage, Alaska 99516 Subject: Waiver Request for Lot 1 P & S Subdivision waiver Request ~WR930049, PID ~015-142-38 Dear Mr. Moore: Your request for waiver of the required 10 foot separation between a septic system and a lot line has been approved. The waived distance is 2 foot from the north property iine. This approval applies to the existing septic system lot line separation only. Any future upgrade to the septic system will require all separations be met or another approval from this department. Sincerely.~ Daniel J. Roth civil Engineer On-site Services DJR/ljm MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 PAGE 1 OF ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT PERMIT NUMBER:SW920415 DESIGN ENGINEER:FLATTOP TECHNICAL SERVICES OWNER NAME:PIERCE JANICE M OWNER ADDRESS:5000 E ll2TH AV ANCHORAGE, AK 99516 DATE ISSUED:12/13/92 EXPIRATION DATE:12/13/93 PARCEL ID:01514238 LEGAL DESCRIPTION: P & S LT 1 LOT SIZE: 22500 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED CIVIL & ENVIRONMENTAL ENGINEERING * ENERGY CONSERVATION & ANALYSIS Tlfl~ODORE F. MOORE, P.E. PH: (907) 345-1355 Robbie Robinson M.O.A. DHHS P.O. Box 19-6650 Anchorage, AK 99519 December 10, 1992 14530 ECHO ST. R E C E i 9'1" DE0 1 0 1992 Municipality of Anchorage Oept. Health & Human Services RE: Lot 1, P & S S/D - Revisions to design of proposed wastewater disposal system upgrade Dear Mr. RObinson: Per your request we have conducted additional soils testing in conjunction with the proposed septic system upgrade for Lot 1, P & S S/D. The logs for test holes 3A, 4, and 5 are enclosed. These test holes revealed significantly different (and more permeable) soils than were encountered in test holes gl ' and g2 submitted with our November 11 application for an upgrade permit. Based on this new soils information we have been able to redesign the upgrade as a soil absorption trench, instead of the originally proposed shallow bed. Thus we are requesting that you withdraw our original design submittal and substitute the enclosed trench design. We believe this revised design will result in a longer useful life as well as result in reduced construction cost. The proposed soil absorption trench will be constructed in the vicinity of test hole g5. As can be seen form the soil log, the native material between 4.5 and 12.5 feet is a silty sand of variable consistency. The material typical of 4.5' to 8' was perc'ed in T.H. g3A, and the material typical of between 8' and 12.5' was perc'ed in T.H. g5. Both of these perc tests showed a perc rate of between 1 and 5 minutes per inch which would normally dictate a design soil application rate of 1.2 gal/day/sq, ft. However, the boundaries between the several strata were indistinct, and we noted~ significant variations of consistency within a short distance. For example, we conducted 2 perc tests at a depth of approximately 10 feet in test hole g4. One of these perc'ed at 2 minutes per inch; the other one 4 feet away in a ~ocket of siltier material. perc'ed at slower than 60 minutes per inch. To compensate for this inconsistency¢:6urrevised design is' BaSed on 0,6 avd/sa. 'ft., which means that only half of the total sidewall area is ne~led; based On the ~easured per~'rate~.., ~'~ - Based on the above design criteria of 0.6 gpd/sq, ft., the total sidewall area required for this 3 bedroom residence is (3 x 150)/0.6 = 750 square feet. The proposed soil absorption trench with 7 feet of gravel below the horizontal distribution pipe at a depth of between 5' and 12' below ground level has a total sidewall area of 770 square feet. 5/c/ /~.~// ~y~ ¢/~,0~-~ -~ ~ ? ¢' I hope that this information will be sufficient for you to issue the requested upgrade permit. Please give me a call at 345-1355 if you have any questions on this submittal. Sincerely, Ted Moore, P.E. /.-AND LOT ~_ 1 o Hou£~ /._oT 3 ~to-~i Technical Services 14530 Echo Street . '~ LOT' t e ~ S/D NOT~: Tl-ttz u NOT ,Bi,.& l...o£A ~'zo/'L.~ PLA /',,/ VIEW/ "= Ftl,.T~R ~CA~.E: A5 NOT~O DWN I~Y: TF~ F/atfop Technical Services 14530 Echo Street Anchorage, Alaska 99516 Flattop Technical Serv~es 14530 Echo Street, Anchorage, AK99516 Phone (907) 345-1355 Lot 1, P & S S/D 5000 East ll2th Avenue Wastewater disposal system installation Specifications 1.0 General: 1.1 The scope of the project consists of abandonment of the existing septic tank and seepage pits and installation of a new 1000 gallon septic tank followed by a 55 foot long soil absorption trench with 7.5 feet of sewer gravel between 4.5' and 12' below ground level. 1.2 Construction shall be as depicted on the revised site Plan and design drawings. Minor deviations from these drawings may be allowed or requked by the engineer conducting the inspections. All construction procedures and material specifications shall conform with Municipal and State requirements. All separation distances shall be in confmrnance with Municipal requirements, unless specifically waived. 1.3 The contractor shall be responsible to obtain any necessary utihty locates, and to work around any buried utilities. 1.4 The contractor shall provide adequate cover material and rough grading over all system components to ensure that proper drainage is achieved after settlement and that there are no residual depressions. Insofar as possible the contractor shall minimize damage to trees and existing lawn areas. 1.5 Unless specifically agreed otherwise, the homeowner shall be responsible for finish grading after the soil is compacted, as well as placement of topsoil and reseeding all areas disturbed by the construction. 2.0 Septic Tank: 2.1 The septic tank shall be a 1000 gallon Municipally approved tank with two compartments, and shall be set level on undisturbed soil. Each compartment shall be equipped with a watm~tight manhole cover and a 4" cleanout. If the tank is buried less than 4 feet, it shall be insulated with 2 inches of approved burial type, rigid insulation. 2.2 All pipe connections to the tank shall be equipped with watelproof mechanical couplings. The waste line from the residence to the septic tank shall have a minimum slope of 1/4'" per foot, and the waste line between the tank and the soil absorption system shall have a minimum slope of 1/8" per foot. A cleanout shall be installed within 5 feet of the building foundation, and a double cleanout shall be installed within 5 feet downstream of the septic tank. 2.3 The existing septic tank and seepage pits are to be properly abandoned by thoroughly pumping, removing the lids and backfilling with clean soil. 3.0 Soil absorption system: 3.1 The soil abso~j?tion system shall be constructed by excavating a 55' long trench to a depth of approximately 12 feet in the vicinity of test hole #5. 3.2 The bottom of the excavation shall be level. Any compacted or smeared surfaces shall be raked to allow proper infiltration. If soil conditions inconsistent with those reported on the log for test hole #5 are ' encountered the configuration of the trench may be field-modified to optimize utilization of the native soils. 3.3 A total of 7.5 feet of approved sewer gravel shall be placed in the bottom of the excavation with the perforated disuSbution pipes laid level such that the pipe inverts are no less than 7.0 feet above the bottom of the sewer gravel. Sewer gravel shall be 0.5" - 2.5" screened gravel, with less than 3% passing the #200 sieve. 3.4 Monitor tubes and cleanout pipes shall be of 4" diameter and installed in the locations.shown on the design drawings. The portion of the monitor tube extending through the sewer gravel shall be perforated. 3.5 Approved filter fabric shall be placed over the entire top surface of the sewer gravel. A minimum of 2 feet of soil cover is to be placed over the filter fabric. 3.6 The top surface of the cover material shall be raised a mininmm of 12 inches higher than the surrounding terrain to allow for subsequent settlement, and shall be graded to smooth contours. 3.7 After the backfill has stabilized, the property owner shall be responsible for placement of topsoil and reseeding the disturbed areas. 4.0 Inspections: 4.1 A total of 4 engineering inspections will be requked during the course of the project: (1) initial stakeout with the contractor to establish the location of the system and to discuss the plans, specifications and construction procedures, (2) after the native material has been excavated to expose the infiltrative surface to ensure that it is level and at the right elevation, and conforms with the soil test information, (3) after the sewer gravel is in place and the distribution pipes have been laid and connected up to the septic tank, but prior to placement of insulation or filter fabric, and (4) after final backfill and grading is complete. The septic tank requires one inspection after it is set level and the piping connected, but prior to backfill. This inspection may be incorporated with any of the above inspections. 4.2 The installer shall coordinate the timing of the inspections with the engineer sufficiently far in advance to ensure the availability of the engineer. PERFORMED FOR: LEGAL DESCRIPTION: t"//-- 1 2 3 4 5 6 '7 8 9 10 11 Flattop Technical Services 14530 Echo Street k~ilchorc~ge, Alctskc~ 99516 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST ~er~ Te~f 'I¢ 3A Township, Range, Section: SLOPE '~.(3~. .~ t l t.? ~can d. (becom~ cleao~r WAS GROUND WATER ENCOUNTERED? ~/ 12 14 15 16 17 t8 19 20 SITE PLAN 1~ lie '/'h s L IF YES, ATWHAT O DEPTH? p Depth Io Water Alter E ~oniloring? Dale: Reading Date Gross Net Depth to Net Time Time L/p,f ;,.~ .~ Water Drop iZ" ..Co,ak _J~J3olgz t: I~ p~ I : 2q + g~O I '. ql .' oo ~E l: q~,'OO 3 lO t ~ ~q I:~:~ ~ lO '1~ I PERCOLATION RATE ,.~ {minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN ~,, O FT AND .~".-~- FT PE~{FORMEDBY: ~'~'/~:;~, ~"]~ 7~0/~1¢~.t .-~Oc_( , ~ ~ CERtlFYTHATTHISTESTWASPERFORMEDIN ACCORDANCE WITH ALL STA:TE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE, DATE: 72-008 (Rev. 4/85) PERFORMED FOR: LEGAL DESCRIPTION: Ft' 2 3 4 7 8 11 12 15 16 17 18 19 20- ~Flattop Technical Services 14530 Echo Street fichorage, Alaska 995].6 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST Ft. ?;e¢ce Township, Range, Section: SLOPE % (¢-. WAS GROUND WATER ENCOUNTERED? . IF YES, AT WHAT DEPTH? Depth to Water Afler ~oniloring? Date: (onx o tio~, led SITE PLAN PERCOLATION RATE ~' (minutes/inch) PERC HOLE DIAMETER t~' ;/ TEST RUN BETWEEN ~,..~- FTAND IO'O FT PERFORMEDBY: F[~~nl¢qt ~o~ , ~ ~_ CER]IFYTHATTHISTESTWASPERFORMEDIN ACCORDANCE WITH ALL STA~E AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: _{~//~/~ 72-008 (Rev, 4/85) Reading Date Gross Net Depth to Net Time Time (' Pit'S) Water Drop PERFORMED FOR: LEGAL DESCRIPT,ON: 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18- 19- 20- ~lcdtop Technical Services 14530 Echo Street ~ifchorage, Alaska 995].6 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST T:H. /2 ~ .~ .-.~/.D Township, Range, Section: ~ , 9?/£ I'I WAS GROUND WATER ENCOUNTERED? SLOPE . N COMMENTS SITE PLAN s IF YES, AT WHAT r/L DEPTH? p E Oeplh to Water Aller hlonitorJno? ...... Dale: Reading [)ate Gross Net Depth to Net Time Time 4~f]~) Water Drop ~ ¢ g: qo: oo e ~ 8 ~1 t~ t '/w PERCOLATION RATE ~ (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN ~', 5" FT AND ~. ~:2 FT PERFORMED BY: F[<:~ ~TI'~,/~ 7'~C.~/'},¢o,[ -~eC.L. : ~--~"~ ~ CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STA~rE AND MUNICIPAL GUIDELINES IN EFFEC] ON THIS DATE. DATE: 72-008 (Rev. 4/85) ,%, PERFORMED FOR: ~-!.~zttop Technical Services 14580 Echo Street /~inchorage, Alaska 9951 ~ Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST LEGAL DESCRIPTION: 2 -- 3 4 P rs 5 Township, Range, Section: 5'ec 8;~, 'TI~N¢ /~'/,~' SLOPE SITE PLAN '~o 11 12 13' 14 ~P F&-i 15 16- 17 18 19 2O COMMENTS I e,~s~ off IwL len~.r of £P WAS GROUND WATER ENCOUNTERED7 .~ ~,/¢ IF YES, AT WHAT DEPTH? neplh to Water After Monitoring? pi, r. PC.Z- I)ate: I0/~ Reading Date Gross Net Depth to Net Time Time (f'7,~) Water Drop (.~'~. . loos~ cleoo eeoc /'<r f' PERCOLATION RATE --~ (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN I.O FTAND I,~- FT ' ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. 72/008 Rev. 4/85) CEWI IFY 1 HAT THIS TEST WAS PERFORMED IN DATE:_ ~Flatfop Technical Services 14580 Echo Street Anchorage, Alaska 99,5~ ~ Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLA'rlON YE-ST T.H. /CZ. PERFORMED FOR:__ "~,¢/./~ I C'~_~ ["~, t)i~l"C -~. LEGAL DESCRIPTION: ~.O ~ I] P ¢~'~ 1 Township, Range, Section: ..eec ~, 'TIP-N/ SLOPE SITE PLAN 10 11 12 13' 14 15 16 17 18 19 20- COMMENTS WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? ,~a~.d..,.~Depth to Water Alter Monilorin~? s L 0 P E Date: Reading Date Gross Net Depth to Net Time Time Water Drop PERCOLATION RATE (mir~t~tes/inch) PERC HOLE DIAMETER PERFORMED BY; Fl,~/-t~__T~__c~_.~l,¢,~r ~'¢~'1"i¢~.j'_ i __~ ~ CEf]]IFY THAT TFIIS TEST WAS PEI]FORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECTON THIS DATE. DATE: 72-008 (Rev. 4/85) TES~ RUN BETWEEN .--_ F'F AND -- lFlattop Technical Services 14530 Echo Street Anch0rc~9'e, Alaskct 99,51~ Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, AJaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR:__ LEGAL DESCRIPTION: 1 2 3 4 5 6 7 8 9 10 11 12 13' 14 15 16- 17' 18- 19- 20- 77, ~ ~/D lownship, Range, Section: ..~ec '~2, '"['12_N, r~l,,~, SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? S L IF YES, AT WHAT O DEPTH? p E i]oplh to Waler Allot Moniloring? _ 13.H, Reading Date Gross Net Depth to Net Time Time (~/1'.) Water Drop ~y ..... ~: q3:30 2 ~ z '/~ t PERCOLATION RATE ~ (mmutestinch/ PERC HOLE DIAMETER ~" TES} RUN BETWEEN ..... _~2~ ET AND ~-...~- F~ ...... ......... ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 72-008 (Rev. 4/85) ~r~ & ~O~ ~~ · ~E~¥ ~O~$~VA~O~ & ~¥S~ THEODORE F. MOORE, P.E. November 11, 1992 14530 ECHO ST. PH: (907) 345-1355 ANCHORAGE, ALASKA 99516 M.O.A. DHHS P.O. Box 19-6650 Anchorage, AK 99519 Dear Sirs: The purpose of this letter is to provide the required design narrative in support of our application for a pemdt to upgrade the wastewater disposal facilities serving the existing 3 bedroom residence on Lot 1 of P & S Subdivision, located at 5000 East 112th Avenue. We were unable to find any records of the existing septic system on file at DHHS, but according to CAMA the residence was constructed in 1963 The existing waStewater disposal system which is now starting to fail appears to consist of a septic tank followed by two seepage pits..~.~oils logs, perc test results, a site plan, design drawings and specifications for the proposedfopgrade are ei~closed for your review. The proposed~il absorptiOn system will be constructed between test holes #1 and #3. As can be seen from the soil log, tli~ natige material I~etween 0.5 feet and 2.5 feet below ground level is a sandy loam overlying a silty sa~l,, both of which: hav~ a m~sure ~dlperc raie of between 1 and 5 minutes per inch. Since the proposed design will incl,ude a Sand [dvelin~ courSe,: the design is based on a soil application rate of 0.7 gpd/sq, ft. spe6)tied in the ~asteWater o~dinance for filter sand This 3 bedroom residence requires a total absorption area~0f (3 x 150)/0.7 = 643 square feet. The prOposed 20' x 33' design has a total absorption area of 660 ~quare feet. The topography of the'10t in the vicinity of the proposed soil absorption bed slopes down to the west at 7% and down to the north at 5%. Since there is no foundation cleanout at the present time, enabling detem~ination of the elevation of the waste line as it leaves the building, the design is based on the assumption that a lift station will be needed, and thus incorporates pressurized distribution. In the event that the waste line is found to be sufficiently shallow, the design may be field changed to eliminate the lift station and utilize gravity distribution. Due to the limited available area on the lot outside the 100 foot protective radius around the well, it will be necessary to use 2.5:1 side slopes on the fill material covering the bed so as not to have the fill spill over the property line. If properly revegetated, a slope this steep should not be subject to erosion or allow daylighting of effluent. The proposed project is not anticipated to have any impact on present or future water supply and wastewater disposal systems serving adjacent properties, nor will it have any impact on reserved space/surface and subsurface, or on di'ainage. Please give me a call at 345-1355 if you have any questions on this submittal. Sincerely, Ted Moore, P.E. ~PTIC H 5~ PRop, I $ I~pTfC 4 #3 JsT.. / Flattop Technical Se. rvices 14530 Echo Street .oho~age, ,~l~k~ S~m ~ .... ,....n.~ LoT Z ~q~PTI C : YST ~PGI'fAD~ ~ IT~ PLA N owN. ~': T'F~ ~r~t~ ,~.PPRO XII'-IATL U.,/. 5-F'$~?" I'tol-,[F,~ DI1H. I-~'p I~ I l LO Y Z, e ~'5- ~/~ ZoI~ A~BZoR?T ~ohl Flattop TechnfcaI Services 14580 Echo Street Anchorage, Alaska 99516 Flattop Technical Services 14530 Echo Street, Anchorage, AK99516 Phone (907) 345-1355 Lot I, P & S Subdivision 5000 Eat ll2th Avenue Wastewater disposal system installation Specifications 1.0 General: 1.1 The scope of the project consists of abandonment of the existing septic tank m~d seepage pits m~d installation of a new 1250 gallon STEP tank with pressm'e distribution of effluent into a 20' x 33' soil absorption bed. If topography allows, a 1000 gallon conventional septic tank and gravity distribution into the soil absorption bed may be substituted. 1.2 Construction shall be as depicted on the approved site'i~lan and design drawings. Minor deviations from these d?a~vings may be allowed or required bj¢ the engineer conducting the inspections. All construction procedur~,and material specifications shall 6onform with Municipal m~d State requirements. All sepm'att~p distances shall be in confo~nance with Municipal requirements, unless specifically waived. 1.3 The contractor Shall be¥6$ponsible to obtain any necessm3~ utility locates, and to work around buried utilities. 1.4 The contractor shall provide'Odequate cover material and rough grading over all system components to ensure that proper dralhgge is achieved after settlement and that there are no residual depressions. Insofm' as possible the cmitr3ctor shall minimize damage to trees and existing lawn areas. 1.5 Unless specifically agreed otherwise, the homeowner shall be responsible for finish grading after the soil is compacted, as well as placement of topsoil and reseeding all m'eas distm'bed by the consU'uction. 2.0 Septic Tank: 2.1 The septic tank shall be a Municipally approved STEP tank with two compm'tments, and shall be set level on undisturbed soil. Each compm-tment shall be equipped with a watertight manhole cover and a 4" cleanout. If the tank is buried less than 4 feet, it shall be insulated with 2 inches of approved burial type, rigid insulation. 2.2 All pipe connections to the tank shall be eqtnpped with waterproof mechanical couplings. The waste line from the residence to the septic tank shall have a miniinum slope of 1/4'" per foot. A clem~out shall be installed within 5 feet of the building foundation. 2.3 If there is sufficient elevation differential between the waste line as it leaves the building and the suitable receiving soils in the soil absorption bed, a 1000 gallon con~,¢ntional septic tank may be substituted for the STEP tank, with gravity distribution to the soil ab~)rption bed. 2.4 The existing septic tauk and soil absorption pits are to be properly abandoned by pumping, removing the tops and backfilling with clean soil. 3.0 Lift station: 3.1 The lift station (if necessm'y) shall be installed itl tile second compm'tment of the STEP tank. The lift station shall be au "Oreuco" system as supplied by Anchorage Tank. 3.2 The contractor shall be responsible to obtain the necessary Municipal electric permit and inspection, and to provide a copy of the electrical inspector's report to the engineer overseeing the construction of the wastewater disposal system. 3.3 The on, off, and alarm floats shall be set at the elevations specified by the lift station supplier, and their proper operations shall be verified by the contractor. 4.0 Soil absorption system: 4.1 The soil absorption system shall be constructed by stripping the snrface organics off the proposed 20' wide by 33' long soil absorption bed m'ea to expose the top of a reddish sandy loam stratum. Cat'e shall be taken to neither overexcavate nor di'ive equipment on the sandy loam 4.2 The bottom of the excavation need not be level. Any compacted or smeared surfaces shall be raked to allow proper infiltration. A level bed bottom shall be created by placement of clean, coat'se sand meeting Municipal specific~[ions for filter sand. An eartl! berm may be created at'ound the bed area prior to excavation to contain the.!~veling sand and sewer graY61. 4.3 A total of 1.0 feet of ~iPproved sewer gravel al{all be plac~ in the bottom of the bed with the perforated distribution pipes laid, level such that the pipe inverts are no less than 6 inches above the bottom of the sewer gravel. Sewer grage! shall be 0.5" - 7-,:'5" screened gravel, with less than 3% passing the #200 sieve. 4.4 Monitor tubes shall be of 4" diameter arid installed in the locations shown on the design ch'awings. The portion of the monitor tube extencti,ng thr0,u~gh the sewer gravel shall be perforated. If gravity distribution is used, a double cleanout ~ball be'installed within 10 feet downstream of the septic tank and 2 cleanouts installed in the perforated disffi~ution pipe at opposite corners fi'om the monitor tubes. 4.5 Approved filter fabric shall be placed, over the entire top surface of the sewer gravel, plus 2 inches of rigid, burial type insulation. A minimum Of 2 feet of soil cover is to be placed over the insulation. 4.6 The top surface of the cover material shrill, be raised a ~ninimum of 6 inches higher than the surrounding terrain to allow for subsequent settlement, and shall be graded to smooth contours. Fill slopes shall be no steeper than 2.5:1. 4.7 All lawn m'eas disturbed by the construction and/or soil absorption mound top and side slopes shall be covered with 4 inches of topsoil and seeded with an approved grass seed to promote rapid revegetation. 5.0 Inspections: 5.1 A total of 5 engineering inspections will be required durihg the course of the project: (1) initial stakeout with the contractor to establish the location of the system and to discuss the plates, specifications and construction procedures, (2) after the native material has been excavated to expose the infiltrative surface to ensure that it conforms with the soil test information, (3) after the sand leveling material has been placed, (4) after the sewer gravel is in place and the distribution pipes have been laid and connected up to the septic tank, but prior to placement of insulation or filter fabric, and (5) after final backfill and grading is complete. The STEP tank requkes one inspection after it is set level and the piping connected, but prior to backfill. This inspection may be incorporated with any of the above inspections. 5.2 The installer shall coordinate the timing of the inspections with the engineer sufficiently far in advance to ensore the availability of the engineer. MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 Parcel I.D. # CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING 1. GENERAL INFORMATION Complete legal description L¢-F I Location (site address or directions) ,~c~¢o ¢.¢,s'-r /l'Z?~--~ Property owner Mailing address Lending agency Mailing address Agent Ad dress Day phone '~ ~'/~ Day phone Day phone Unless otherwise requested, HAA will be held for pickup. NUMBER OF BEDROOMS: TYPE OF WATER SUPPLY: Individual well Community well Public water NOTE: If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. TYPE OF WASTEWATER DISPOSAL: Individual on-site Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025 (Rev, 1/91) Front MOA #21 STATEMENT OF INSPECTION BY ENGINEER As certified by my, seal affixed hereto and as of the validation date shown below, I verily' that my investigation of this Health Authority' Approval application shows that the on-site water supply' and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and ty,pe of structure indicated herein. I further verify' that based on the information obtained from the Municipality' of Anchor.a. ge files and from my, investigation and inspection, the on-site water supply' and/or wastewater disposal sy,stem is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm ~,¢o~,,,~ ~.¢4. %¥c_ Address <;so-cg ,~c~ m / cl-~o ~-.~- e l~,oC.14- Engineer's signatu re~r.~------- A~ Phone Date DHHS SIGNATURE ./~ Approved for 3 Disapproved. Conditional approval for bedrooms. bedrooms with the following stipulations: Additional Comments By: ~/ Date ~ -//~'- F~/' The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority, Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-025 (Rev, 1/91) Back MOA #21 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SEI:I~/L~~ IV E D Environmental Services Division 825"L" Street, Room 502. Anchorage, Alaska 99501. Municipality of Anchorage ChecklisBept.~ Health &Human Serv.ces Health Authority Approval Legal Description: A. WELL DATA Well type q'~R~o~,~r'~ Log present (Y/N) Total depth [9 ~q Sanitary s~ (Y/N) If A, B, or C, attach ADEC letter. ADEC water system number Date completed O M Ic, Moco~/ Cased to ~'O '~ Casing height (above ground) FROM WELL LOG Date of test Static water level Well production WATER SAMPLE RESULTS: Coliform ~ ~ ~-- Date of sample: '~ -~ --*/b B. SEFI'IC/HOLDING TANK DATA Date installed .5-[~/c}~ Tank size Foundation cleanout (YiN) ~ Date of Pumping 'o,-- 9~_~ q & C. ABSORPTION FIELD DATA Date installed ~ ' ~--~'-~3 Nitrate Wires properly protected (Y/N) AT INSPECTION lq q ,5>- ~ g.p.m. '2.~ '~ 4- g.p.m. l, ~- ~- Other bacteria .~ cO ~ Collected by: ~ , F~ ~q"~n./ ,MOtV 6~ ! ~ Number of Compartments Z- Cleanouts (Y/N) . Depression (Y/N) ~ High water alarm (Y/N) .,4//~ Soil rating ~ ft2/bdrm) O ~- 6, System type Length Z~-~5-~ Width ~....S-- Gravel thickness below pipe ~ t Total depth l~2 ,,_%- t Effective absorption area °c.;tO Monitoring Tube present(Y/N) ~( Depression over field (Y/N) AY Date of adequacy test -"/- ,~'z-?~, Results (Pass/Fail) ~A,Sg For 2~ bedrooms Fluid depth in absorption field before test (in.); Fluid depth 'I~IZ~ (ins.) Minutes later: peroxide treatment (past 12 months) (Y/lq) Immediately aRer ~4$Ogal. water added (in.): Absorption rate = / ~q O + g.p.d. Ifyes, give date " ' Do Lll~F STATION Date installed Manhole/Access (Y/N) *Datum ~2yel~ted E. SEPARATION DISTANCES "Pump oft" level at* SEPARATION DISTANCES FROM WELL ON LOT TO: Septic/holding tank on lot / O3 ~ Absorption field on lot Public sewer main Sewer/septic service line ; On adjacent lots / ; On adjacent lots / Public sewer manhole/cleanout ,A~ Lift station /Ocg-t- SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation ..~ O t . Property line ! ,.%- t Absorption field Water main/service line ,/tl~'~} */' Surface water/drainage /OO't- Wells on adjacent lots SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Building foundation ~ t9 t Surface water / oo + Curtain drain ! ~a, m ENGINEER'S CERTIFICATION / e,o '~- LO ~kxv ~.'-~L 6 e~v., -r-~3 Property Line '2 ~L Water main/service line Driveway, parking/vehicle storage area Wells on adjacent lots I certify that I have determined thru field inspections and review of Municip in conformance with MOA HAA guidelines in effect on this date. Signature_ ~ _ Engineer's Name ~w-z~x ~-~/.) %.<~v~,aa/~,q~.~. HAg. Fee $ Date of Payment Receipt Number Rev. 8/95 OSS: haa.wk.doc Waiver Fee $ Date of Payment Receipt Number 17:42 ESI ANCHORAGE * 907,~72 8218 NO. 35? Q03 CT&E Environmental Services Inc. Laboratory Division ~ag~m~e',am~',a",e',~',~e~,~,a~.a.~,~F,~r,e~,,am~,a~-amm,~~,.~,,~.~ CT&E Ref.# Clle~t Name Project Name/# Clie~t Sample ID Matrlx Ordered By PW$ID ~mpl¢ Remarks: 963'120001 Ptumone Eng S~, Outskb Tap Outside Tap Drinking Water 200 W. Potter Drive Anchorage, AK 99618-i 605 Tel: (907) 562.2343 Fax: (907) 561-5301 Client PO# Printed Date/Time 07/26/96 08:40 Collected Date/Time 07/22/96 20;00 Received DateJTime 07/23/96 08:00 Technleal Director At[owable Prep Anetysfs Parameter Resu[t~ PQL Units Method Limits Date Date Init Nitrata-N 1.75 0.100 m~/L EPA ~55.2 0T/23/96 EM8 Nitrite-N O~lOOU 0.100 mg/g EPA $53,2 07/23/96 EMB Total coliform 0 0 co[/lOOmL eMI8 ~2gZB 07/2~/96 TAV ~ ~ Membsr of the SGl~ Group iSocietC~ G~ni~rale de ~urveiilence) ENVIRONMENTAl. FACIUTIE~ IN ALASKA, CALIFORNIA,. FLORIDA, ILLINOIS, MARYLAND, MICHIGAN, MISSOURI, NEW JEffrEY, OHIO, WEST VIRGINIA