Loading...
HomeMy WebLinkAboutPARK HILLS RIDGE LT 1 LOT 2 OREENPOfNT AVE NOTkS: SURVEYOR'S CERTIFICATE PLAT APPROVAL CERTIFICATE OF OWNERSHIP and DEDICATION ACCEPTANCE OF DEDICATION TAX CERTIFICATION A PLAT OF: LOTS 1,2,~,4 LL_% F~IDOE APPROVALS BRAWN By DMD -9 w. o4, 93-S-2 DTI001268 Municipality of Anchorage Page 1 of 4- .. DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION - P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: SW980361 PIDNumber: 01 '7-113-03 ..-',' '~"~: " wastewater SystEm: ~ew [] Upgrade Joseph Desj arlais 10201 Betula Drive Anc. ,AZ RPTION FIELD Pho.~: 562-3640 I"°'°f¢~'°°~",: O Deep Trench ~haflowTrench OB~ OMound Soil Rating: / ~ TO~I Depth from origi~l grade: Lot: Block: Subdivhion: ~ffi to pi~ ~om from original grade: Gravel dep~ ~neath pipe I N/A Park Hills Ridge ~.o R. ~ Ft. Township: IRange~. ~ktion: mlladdoda~veoriginalg~de:~ Ft. G~velleng~ WELL: =' ~ New O Upgrade G~vel~dth: ~ Ft Num~rof lin~:.. /~]DJsm~nlA~ Clmifi~ti~n (Private. kB.C): Total Oep~: ~s~ To: Total abso~tion area: Pi~ mateda~ SEPARATION DISTANCES ~p~ ~ Ho,di~g a S_T.~.~. Lot I / Si~e in gallons: [ Manufacturen High water alarm at: C uAain ¢ ,~ ~mp Make~l~trical Insp~tions .d0~ed by: Drain _ Remarks: BENCH MARK L~don and O~dption: ~um~ Bevation:f~O. ;~ Ft. ENGI~ ~EAL of Health and Human Services approval '¢;:~.:.~ ~*....,~ Department permit,No, ' SW980361 Page 2 .of. 4 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Legal. Description: LT 1, park Hills Ridge Subdivision 100 ' well .Co ~ 1., 250 Gallon septic 017-113-03 PID NO,' -~x ;~ '-- "- radiUs ~,/ ' ~ '3 ,B~ :HoUse PLAN AS-Built SP1 -SP2 L ~ ' ~- ~bsorption trench : · .,. , '~ CO clean' out ~ [ - . · SP stand pipe · ," '.~ . HT monitor tube Evergreen St. of ,Permit.No. SW980361 Page 3 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Legal Description: q~' '1.250 LT I, Park Hills Ridge Subdivision PID No.:017-113-03 septic tank' 42 LF C.I.P. 2" Dow in~_l. 20.0 Elevation AS Built CO clean out SP . sband pipe MT' monitor tube 1. loo.7~ / ~ / ' /-- _ _/_ _ / / / ----~I . ]- / , / / '±NS3 '9~93 ~ 'NN0~393± ,0~ C? / / ' / _~ / . : ~/ ~/ . . / ~/~ / ~,_ ~ ........ ............ : :-:-~ . /" .~? /J Mun,clpahty of Anchorage Pag, 4 o, 4. :- /: ~? // ' DEP~RTMENT OF HEALTH AND HUMAN SERVICES . /': *~" {/ ENVIRONMENTAL SERVICES U V S ~N ' ;.~/~" ~ P.O Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 ~' /~ O~i~e Wastewater DispoSal System and/or Well Inspection Report ~ ~' Permit Number' _ 5~98036~ ' ._ . . 'PIDNumbe~: 0~7=1q3=03 / i/ I 1" = 50' Park Hills Ridge Subdivision Reserw~ ~ OJ' ,oo'o'~ F~om : ALPINE DRILL 90~ ~45 0L:~2 m~c. 08.19~8 06:00 RM P01 STATE OF AL~81CA DEPARTMENT OF NATURAL RESOURGE8 DIVISION OF MINING & WATER MGMT a~aH GU~IVISION LOT 8LOCK ~CT~OH QTfl8 ~EOTION TO--HIP ,, . LOCATIONISK~CH: WELL O~ER: DEPTHS M~SURED FROM~casing top ~gmund surface TWILLDEPTH: ~ / DATE OF C~PL~ION .... ' ' Depth of hoJo:~ ft Matetlal Type a~ Color From To - ' ' ' ft below ~ top of casing ~ ground suvaco M~HOD OF DRILLING: ~ air rotary ~ cable tool / ". ....... USE OF WELLt ~ domestic ~ irrigation ~ mOnltef ' / CASING STICK-UP, ~_ft. Diam: ~in. tO~ft ........ Casing 'type:~~ _.~ In. tO ~/ ft WELL JNTAKE OPtiNG TYPE:/~-open end ~ screened ~ perforated ~ open hole SCREEN TYPE; Bi, m: .... in. ' JUL 7 ,19~ ~ , Slot/Mesh Size: ,,, .,, Length: ft G~VEL PACK TYPE: Municipality et An( ~orage Volume used: ...... Depth to t~:a _. . Depth: from .... ft to ft D~ELOPMENT M~HOD: PU~NG L~EL AND _~,. f~ a~ter ,~-~ h~ pumping ~ gpm PUMP ~TAKE DEPTH: ...... W~L DISINFECTED UPON C~PL~ION? ~YES ~ NO CONTRACTOR INFORMATION; REMARKS; ~ DN"/D~ISlO. OF MI"~G & WATE" MGMT Signature ot Author~ed Respre~tive D~ 3601 C St, Suite ANCHORAGE AK 99503-5935 Phone ~907)269-8839, Fax MuniCipality of Anchorage. DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: Joseph Dejarlais LEGAl :RIRTION: LT 1, Park Hills DATE PERFO Township, Range, Section: -2 ob 11 12 13 14 15 16 17 18 19 20- COMMENTS Ridge Subd. SLOPE 5 8 WAS GROUND WATER 1 / ENCOUNTERED? 0 DEPTH? /'~' p E Depth to Water Alter ,~,~-- Monitoring? SITE PLAN EVERGREEN STREET Reading Date Gross Net Depth tO Net Time Time Water Drop !~ ~;,q-~,=,F I~,,~ ~.~ .~.o~ PERCOLATION RATE '~ (minutes/inch) PERC HOLE DIAMETER Municipality of Anchorage. DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: JosePh Dejarlais DATE PERFO LEGAL DESCRIPTION: LT I, 1 2 3 7 8 ~0 12 14 16 17 lg 20 Park Hills Township, Range, Section: Ridge Subd. SLOPE WAS GROUND WATER ENCOUNTERED? SITE PLAN EVERGREEN STREET S IF YES, AT WHAT ~ ~,~- 0 DEPTH? /-- p E Depth to Water After ~.,,¢ Moflil~ing? ~./'~- Oat~ Reading Date Gross Net Depth to Net Time Time Water Drop ' PERCOLATION RATE ~ (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN ~L~ FT AND ~ FT MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 995~9-6650 (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM ! WATER SUPPLY PERMIT Initial Date Issued: Sep 15, 1998 Expiration Date: Sep 15, 1999 Permit Number: SW980361 Legal Description: PARK HILLS RIDGE LT 1 Design Engineer: 0014 Anderson Engineering Owner Name: JOSEPH DESJARLAIS Owner Address: 10201 BETULA DRIVE ANCHORAGE , AK 99507-4131 This permit is for the construction of: [] Disposal Field [] Septic Tank [] Holding Tank Parcel ID: 017-113-03 Site Address: 014919 EVERGREEN ST Lot Size: 123533 SQ. FT. Total Bedrooms:~ Permit Bedrooms:/4~ [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. TOTAL DEPTH OF EXCAVATION MUST NOT EXCEED 5 FEET BELOW ORIGINAL GRADE THROUGHOUT ENTIRE TRENCH LENGTH. Received By: " ~/Z Date: Issued By: ~-~/ ~'~ Date: DATE: TO: MEMORANDUM FROM: SUBJECT: May 26, 1999 Onsite Services Engineer Mike Anderson, p.E.'~'~ Lot 1, Park Hills Ridge Subdivision Permit No. SW980361 RECEIVED MAY 2. 6 1999 Municipality of Anchora, Dept. Health & Human Ser[tg/cees The owner of Lot 1, Park Hills Ridge Subdivision encountered several feet of old fill, organics and other deleterious material on his lot during construction of the house. The discovery of this poor material forced him to move the house forward on the lot and away from the planned and permitted septic system locations. We are therefore requesting the location of the new system be moved to the location shown on the attached Site Plan. Testholes excavated in the new area indicate poorly graded sand and gravel from 2' to 4' below the surface which percolate at a rate of I to 2 minutes per inch. This material is underlain by silty gravel with a percolation rate of 15 minutes per inch. Groundwater was monitored at 8' below the surface. We are proposing placement of a 5' wide shallow trench with 2' of gravel beneath the distribution pipe. Total depth of the trench will be 4' which is 4' above the groundwater level. Total length of the trench will be 80'. The original permit was issued for a 4 bedroom home. The owner, however, has constructed a 3 bedroom home and requests the permit be modified to reflect 3 bedrooms. The as-built for the new system will show the modified location and the original location will become the alternate site. In addition, all paperwork will be upgraded to Municipal standards. CALCULATED BY. CHECKED BY. I SHEET NO. OF CALCULATED BY DATE ANDERSON ENGINEERING P.O. Box 240773 ANCHORAGE, AK 99524 (907) 563-7155 (907) 337-8855 CHECKED BY SCALE DATE Received Time-May.25.~J 0:33AM- Rick Mystrom, Mayor Department of Health and Human Services 825 "L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 http://www.ci.anchorage.ak.us 343-4744 April 17, 1998 Joseph Desjarlais Talisha I Desjarlais 10201Butula Drive Anchorage, Alaska 99507 4131 Subject: Lot 1 Park Hills Ridge - 14919 Evergreen Street Permit #SW970054, PID #017-113-03 The subject permit, issued April 8, 1997 by this office for a single family well and/or on-site wastewater system, has expired as of April 8, 1998. A new permit must be obtained from this office for a well and/or on-site wastewater system NOT installed by the expiration date. If you have drilled the well, a well log must be sent to this office for documentation of the installation and to close the permit. If a licensed Professional Engineer has inspected the installation of the on-site wastewater system, the original as-built inspection report must be sent to this office for review, approval and documentation. Ail inspection reports must be submitted within 30 days of construction completion. When applying for a new permit, the fees are: $320.00 for an on-site wastewater permit; $120.00 for a well permit and $440.00 for a combined on-site wastewater and well permit. If yo~have any questions, please call this office at 343-4744. S/ince~ely,"×/ ~ Jam~s Cross, P.E. Pro~ram Manager On-site Services enc: Copy of Permit cc: Anderson Engineering MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUPLAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 PAGE 1 OF ON-SITE WELL A/~D WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW970054°/ DESIGN ENGINEER:ANDERSON ENGINEERING OWNER NAME:DESJARLAIS JOSEPH & TALISHA I OWNER ADDRESS:10201 BETULA DR. ANCHORAGE, AK. 99507 DATE ISSUED: 4/08/97 EXPIRATION DATE: 4/08/98 PARCEL ID:01711303 LEGAL DESCRIPTION: PARK HILLS RIDGE LT LOT SIZE: 123533 (SQ. FT.) NUMBER OF BEDROOMS: 4 THIS PERMIT: 4 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AACS0). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: TOTAL DEPTH OF EXCAVATION MUST NOT EXCEED 5 FT. BELOW ORIGINAL GRADE THROUGHOUT E~IRE TRENCH LENGTH. ISSUED BY: DATE: DATE: MEMORANDUM DATE: April 6, 1997 TO: FROM: Jim Williams Mike Anderson, P.E. SUBJECT: Lot 1, Park Hills Ridge Subdivision Septic System Permit Attached is the revised trench section for the absorption field proposed for Lot 1, Park Hills Ridge Subdivision. In accordance with our conversation last week I have raised the distribution piping to within 1.5' of the original ground surface. This should provide for a minimum of 5' separation from the highest observed groundwater level at this location. Testhole No. 5 was originally excavated in mid September of 1993. No groundwater was noted during the excavation nor was any observed during the monitoring period the remainder of 1993. In mid February of 1994 water was noted at a depth of 10'. We were unable to determine whether it was actually groundwater or snowmelt. In mid June of 1994 no water was found in the monitor tube and it remained dry throughout the summer. I have also enclosed testhole documentation completed by LeRoy Reid in April of 1984. His Testhole No. 15 is located approximately 30' from our Testhole No. 5. His documentation shows no groundwater encountered during placement of the hole. His percolation data is also similar to that obtained during our test. Although major portions of the lot are bothered with groundwater problems it appears the site chosen for the absorption trench may be an exception. Hopefully this backup documentation justifies placement of the trenches at the elevations shown on the revised drawing. Please let me know if you have additional questions. RECEIVED MunicipalitY of Anchorage Dept, Health & Human Services March 16, 1997 Municipality of Anchorage Department of Heath & Human Services 825 "L" Street Anchorage, AK 99502-0650 Subject: Lot 1, Park Hills Ridge Subdivision Septic System Design Impacts to Adjacent Properties Dear On Site Services Engineer: We hereby apply for a permit to construct an onsite septic system on Lot 1, Park Hills Ridge Subdivision. The attached site plan and backup documentation identify the size and location of the new system as well as the proposed location of the well to serve the house to be constructed on the lot. Surface water is known to exist in the area and surface grading will be required to maintain 100' separation between the septic system and any surface water. A percolation test completed on the soils in the area of the new absorption trenches indicated a rate of 24 minutes per inch. We propose to place 5' trenches with 3' of gravel beneath the distribution piping. Total depth of the system will be 6' below the surface. Extensive water monitoring in this area indicated the groundwater level came no closer than within 10' of the surface and is totally absent during much of the year. The drainage patterns on the lot will not be affected by the construction of the new system. Low areas within 100' of the system will be regraded so standing water will not occur. If the system is constructed as designed the following statements can be made: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. Lot 1, Park Hills Ridge March 16, 1997 Page Two The system, if constructed as designed, will have no adverse impact on reserved space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse impact The current drainage pattern wil on drainage patterns in the area. be maintained. Sincerely, Michael E. Anderson, P.E. Attachments 03 ~ I I · },¢'bs ~9%L6'/c2 ~OV~I~S OLLd.~S ,00/ )~0 ¥~1~S OLLd_~S '~t'bs LLC'OB I. (~ q ,,9L,9!~,69 S £~ lOq AB a3l¥Ola3d ION) 0330 Ag 'J3NNO~I · "JVNOI~IO FLLIM HSN1.J 'i3NOV~ FLLIM 3did IdnNl~l~-I¥ .0~' X .~'l~. ~ v NO iN:~HnNO~t dVO qV ,,~L ~ V HIIM C]=IOV-ld3~I / 'aNno~o 'IYN!OI~IO HI~ 9L lOq m L R L ~ iOq LOT5 1.765 acres NOTE: s a9'4~15' £ 156.02' 4.79.25' $ ~9'40'1b" £ LOT4 1,898 acres AREA MAP SCALE 1" = 120' NO Wells Within 100' of Proposed Septic System. APPROXIMATE -IOME LOCATION ALTERNATE SITE EVERGREEN STREET LOT 1, PARK HILLS SITE P LA N SCALE 1"= 50' PROPOSED 4 BEDROOM HOME (EXACT LOCATION TO BE DETERMINED) 100' WELL PROTECTIVE RADIUS / / GALLON SEPTIC TANK ZABEL Z200 FLOW SPLITTERj NOTE: SYSTEM PLAN NO SCALE MAINTAIN 100' SEPARATION DISTANCE FROM SEPTIC TANK -AND DRAINFIELD FROM Al! SURFACE WATER. SOME SURFACE FILLING Al~ GRADING WILL BE REQUIRED. LOT 1, PARK HILLS RIDGE SUBDIVISION DESIGN FACTORS: Four Bedroom Home Perc. Rate: 24 MinJInch Application Rate: .6 GPD/SF 4 Bedrooms X 150 GPD ! .6 GPD/SF 1,000 SF/5 LF X .58 (Red. Factor) SYSTEM REQUIREMENTS: Wide Trench System 1,250 Gallon Septic Tank 3' Drainfield Rock = 1,000 SF of Absorption Area = 116 LF Length of Trench Therefore: Construct a Wide Absorption Trench With Two Laterals, Each 60' in Length. Distribution Pipe in Trench Placed at 1.5' Below the Original Ground Surface. NOTE: TYPICAL WIDE TRENCH SECTION (NO SCALE) Grade Area Over Trench to Drain Away. Bottom of Trench to be 4' Above Groundwater. Minimum 3' of Cover Over Distribution Pipe. LOT 1, PARK HILLS RIDGE SUBDIVISION (ALTERNATE SITE) DESIGN FACTORS: sYSTEM REQUIREMENTS: Four Bedroom Home Perc. Rate: 54 Min./Inch Application Rate: .3 GPD/SF Shallow Bed System New 1,250 Gallon Septic Tank Place Atop SM/SP Layer 4 Bedrooms X 150 GPD = 600 Gallons Per Day 600 GPD/.3 GPD/SF = 2,000 SF / 15 LF (Width)= 133 LF Total Length Therefore: Construct a Shallow Bed System With Two Beds a Total Length of 133' and 15' Wide. Beds to Be Placed at 3' Below Existing Ground Surface Atop the SM/SP Layer. ¢., 0 O G NOTE: TYPICAL SHALLOW BED SECTION ~inimum 4' Separation from Ground Water.~~~-~ ~~ ra,e ,rea Over .., .o Minimum 3' Cover Over Bed. Zabel Z200 F10w Divider * Zabet Z200 D F10w Director BRAND NEW FOR 94- The Zabel Flow Divider replaces old fashioned distribution boxes and pipe manifolds and The Zabel Flow Director replaces expensive, old fashioned Y-valves. They are also more effective and easier to install. All Zabel products are manufactured ~om high quality injection molded PVC and carry Zabel's Lifetime Warranty if parrs fail due to manufacturer s defect in material or workmanship. The warranty does not include replacement parra not sold by Zabel and does not include labor for removal or reimtallation. 1. The Flow Divide distributes effluent leaving the septic tank by means of a patented central weir design that insures the flow is evenly divided even if the Flow Divider is not perfectly level. 2. The inlet pipe of the Flow Divider is constructed so that effluent will flow from it and down into the effluent into two equal portions. 3. Distributes flow be=er than D-boxes and mani- folds that are subject to frost heave or ground settling. 4. Testing shows that even with a level discrepancy of I/8" or more between the right and left port, the division of the flow was almost 50/50. A standard D-box or manifold distorra the flow under these ' same conditions. 1. The Flow Director is a Flow Divider with a pat- entedsleeve valve installed to distribute the efflu- ens flow to a primary field of your choice and allows the secondary field to rest until needed. 2. The F~ow Divider automatically back flows from the primary to the secondary field and does not depend on the homeowner to change the sleeve valve in the Flow Director. A standard Y-valve is dependent on the homeowner to change the flow direction at the proper time. Unfortunately, this usually does not happen and a problem develops such as an effluent break out resulting in ground water contamination. 3. At the time the septic tank is normally serviced, the septic tank service company can redirect the flow allowing the primary, field the opportunity to rest. · · Manufactured from injection molded PVC. · Always insures an everi flow. · Doesn't create solids build up. · Will not clog. " · Lifetime Warranty. Laboratory Test Results using 1OOO ml samples @ 3 ~m Average Distribution 50.03% 49.97% Level Right Port Left Port 1/16" Tilt Right Port Left Pox 1/8" Tilt 50.2% 49.8% LRight_ Port 51.3% ett Port 48.7% Quesrion.s concerning Z200 Flow Divider · Zabel Z2OO-D Flow Director please call 1-800-221-5742 or Fax (502) 267-8801 for further information. 7"00.01.11194 PERFORMED FOR: LEGAL DESCR,.TIO.: -r-r~= C. P/.~.~- /-/1~ 2 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Ala'~;ka 99502-0650 SOILS LOG -- PERCOLATION TEST WAS GROUND WATER ENCOUNTERED? dL 11 12 17 19 20 Township, Range, Section: SLOPE SITE PLAN S L IF YES, AT WHAT O DEPTH? p E M0nlloring? ~) aa~ /O :7 , Reading Date Gross Net Depth 1'o Net Time Time Water Drop "PERCOLATION RATE Z't'~' (minutes/inch) PERC HOLE DIAMETER ': / TEST RUN BETWEEN ~ FTAND .. ~' FT ...:,!: ?,: .':' .: ...... . ACCORDANCE WITH ALL STATE AND'MUNIC['P~L GUIDELINES IN EFFECT ON THIs DAT[ DA,~ 72~8 (R~. 4/~) :. Municipality of Anchorage DEPARTMENT OF HEALTH & H..UMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 · SOILS LOG -- PERCOLATION TEST Township, Range, Section: SLOPE WAS GROUND WATER .~__~[~ ENCOUNTERED? SITE PLAN COMMENTS [ S //V~L IF YES, AT WHAT oep~ ~ wa~,r Aaor.E ~/ ,' /O/E..' Reading Data Gross Net Depth to Net - Time Time Water Drop ~' <~/~-~7t /" ,'.~0 -- ~,'-- /~.'~~/~ ,, ~]~,, /I ~/o ~ z]~,, '/z '~ PERFORMED FOR: LEGAL DESCRIPTIO~ 1 2 3 4 5 6 7 8 9- 10- 11 1.2 13 14 15 16 '17 18 19 20- COMMENTS PERFORMED BY: MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 Lo Street, Anchorage, Alaska 99501 264,4720 SOILS LOG-- PERCOLATION TEST SLOPE i -Fi PERCOLATION TEST SITE PLAN WAS GROUND WATER ~0 SL ENCOUNTERED? P E IF YES, AT WHAT DEPTH? Gross Net Dl~pth to Net Reading Date Time Time Water Drop CERTIFIED BY:. ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: Lot 1, Park Hills Ridge Subdivision GENERAL: 1. The scope of this project includes furnishing and installing a new 1,250 gallon septic tank. Work also includes the construction of a new 5' wide absorption trenches a total of 120' long at the location shown on the Site Plan. A flow divider shall be placed between the two components of the absorption bed. Filling and grading will be required to assure a 100' separation distance from any surface water and all components of the septic system. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION 1. A new 1,250 gallon septic tank must be procured from an approved source and installed at the location shown on the Site Plan. Lot 1, Park Hills Ridge Subdivision March 16, 1997 Page Two 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trenches shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. Lot 1, Park Hills Ridge Subdivision March 16, 1997 Page Three 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trenches to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to. placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a Municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). Septic tank inlets and outlets shall be fitted watertight couplings (Caulder, Fernco, or equal). with Lot 1, Park Hills Ridge Subdivision March 16, 1997 Page Four 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: A minimum of two inspections are required by Municipal Ordinance. These inspections must be conducted under the supervision of aprofessional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as-built of the completed system. SITE GRADING: The entire area must be graded upon completion to assure a minimum of 100' separation distance is obtained from any surface water and the septic tank and the absorption trenches. Parcel I.D. # MUNICIPALITY OE ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING 017-11'~-0~ '" HAA# GENERAL INFORMATION Complete'legal description Lot 1, Park Hills Ridge Location (site address or directions) '-.~ Property owner Jo_~2h ~e.Ta~l~is Mailing address 10201 Lending agency Mailing address Evergreen Street Betula Drive Anchorage, Day phone 562-3640 AK 9~07-413q Day ~hone Agent Address Day phone Unless otherwise requested, HAA will be held for pickup. 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: NOTE: Three (3) XXX Individual well Community well Public water If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. TYPE OF WASTEWATER DISPOSAL: Individual on-site Holding tank Community on-site NOTE: XXX Public sewer If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025 (Rev. 1/91) Front MOA~21 o STATEMENT OF INSPECTION BY ENGINEER ': As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein, i furtherverifythat based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm Anderson En~ineerirl~ Phone §22-7773 Address P,O, Bn¥ 2/,Q7'7'~ /~cho~-~ AE qq~2/~ Engineer's signature ~-'~J'-'"-% Date ? / 2 / 99 DHHS SIGNATURE ~ Approved for ~"/-//~Ebedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: Additional Comments By: The Municipality of Anchorage Dep~r~ment of Health ~nd Human Service8 (DHH$) issues Heelth Authority Approval Oer~ificates based only upon the representations given in paragraph {5 ~bove by 8n independent professional engineer registered in the SJ~e of Alaska. The DHH$ doeB ~hi$ ~s ~ ¢our~eeyto purohasem of home,s ~nd ~heir lending instiJutions in order to 88tisfy certain federal ~nd mate requirements. Employees of DHHS do not oonduo~ inspections or analyze dat~ before ~ certificate is i~ued. The Municipality of Anchorage is not responsible for error~or omissions in the professional engineer's work. 72-025 (Rev. 1/91) 8ack MOA I¢21 'o Municipality of Anchorage - JUL 0 6 19c)9/~ DEPARTMENT OF HEALTH & HUMAN SERVICES nwronmental Services Division ,¢,uN CIPALITY OF ANC~ 825 L Street, Room 502 · Anchorage, Alaska 99501 · (907)~3~'3-~z~'/z~z~ Health Authority Approval Checklist Legal Description: Lot 1, Park Hills Ridge Parcel I.D.: 017-11,3-03 A. WELL DATA Well type Private Log present (Y/N) Total depth 81 ' Sanitary seal (Y/N) Y If A, B, or C, attach ADEC letter. ADEC water system number Date completed Cased to 81 ' FROM WELL LOG 12/7/98 Casing height (above ground) Wires properly protected (Y/N) AT INSPECTION Date of test 12/7/98 Static water level _31 ' Well production /+0 WATER SAMPLE RESULTS: Coliform 0 Date of sample: 6/28/99 g.p.m. Nitrate .5 mg/L g.p.m. Collected by: Other bacteria 0 A. Harala B. SEPTIC/HOLDING TANK DATA Date installed 5125/99 Foundation cleanout (Y/N) Date of Pumping New Tank size I ~ 250 Number of Compartments 2 Cleanouts (Y/N).~ ¥ Depression (Y/N) N High water alarm (Y/N) N Pumper Conetruction Y C. ABSORPTION FIELD DATA Date installed 5/2?/99 Length 80 ' Width _ Soil rating (g.p.d./ft2 or ft2/bdrm) 1.2/./+5 System type 5 ' Wide 5 ' Gravel thickness below pipe Effective absorption area ~ SF Monitoring Tube present (Y/N). Y Date of adequacy test New Const. Results (Pass/Fail) Fluid depth in absorption field before test (in.); Fluid depth. (ins) Minutes later: Peroxide treatment (past 12 months) (Y/N) N 2 ' Total depth 5 ' ~ Depression over field (Y/N) For Immediately after . gal. water added (in.): Absorption rate = g.p.d. If yes, give date Trench bedrooms 72-026 (Rev. 3/96)* D. LIFT STATION - None on Lot; Date installed Manhole/Access (Y/N) High water alarm level at* Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic/holding tank on lot > 1 O0 ' Absorption field on lot > 100 ' Public sewer main N/A Sewer/septic service line >25 ' Size in gallons "Pump on" level at* *Datum "Pump off" level at* On adjacent lots > 1 00 ' On adjacent lots >1 O0, Public sewer manhole/cleanout N/A Lift station SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Foundation_ > 5 ' Property line > 5 ' Water main/service line > 1 0, Surface water/drainage) 1 O0, SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line > 10, Building foundation :> 1 0 ' Sudace water >100, Curtain drain. . l~one on Lo+~ ENGINEER'S CERTIFICATION I certify that I have determined thru field inspections and review of Municipal in conformance with MOA HAA guidelines in effect on this date. Signature ~ ~.~~ Engineer's Name Hi ,"h~l ~,, - Anr']~ ~ p · ~, , Date 7/2/99 HAA Fee $. ~'~ (~ "~ Date of Payment ~/'~./G ./~' '~ Receipt Number .~'"-~) ~ ~ ~5 ~ Absorption field ~> _5, Wells on adjacent lots > 100 ' 72-026 (Rev. 3/96)* Water main/service line ) 2 5 ' Driveway, parking/vehicle storage area 2 ~ Wells on adjacent lots > 100 ~ Waiver Fee $ Date of Payment Receipt Number "~"~t~m~ CT&E Environmental Services I.c. CT&E Ref.# Client Project Client &anple ID Ma~x Orde~d By PWS~ 993050001 Anderson Engineering L! ! Park Hills Ridge Lt 1 Park Hills Ridge Drinking Water Client PO~ Prin~ed DatefI'ime 06/29/99 16:54 Colletned D'ate/Time 06/28/99 14:25 Reeeiv-~d Date/Time 06/28/99 16: tO Technical Director: Stephen C. Releas,~d By ~ ~ Sample Remarks: Atto.abLe Prep An=ty$i= Limits Date Da=e lni~ Total Co, iform o 0.500 u ¢ot/lOOmL ~N18 9~Z28 0.500 n~q/L EPA 300.0 Ob/2B/99 r..AP 10 r~Jx 06/28199 06/28/99 SCL Received Time Jul. 2. IO:I4AM