HomeMy WebLinkAboutSOUTHPARK BLK 1 LT 5South Park Block 1 Lot 5 #020-491-05 Municipality of Anchorage On-Site Water and Wastewater Section ^ (907) 343-7904 Page 1 of 2 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP201401 PID Number: 020-491-05 Dwelling: ❑ Single Family (SF) ❑ with ADU ❑ D Duplex p (D) El Two Single Family Project: El New ❑Upgrade Name William & Patricia Schreck ABSORPTION FIELD Site Address F] Deep Bed E] Mound Deep Trench ❑Wide Trench 16120 Terracewood Lane El Other Phone Number of Bedrooms Soil Rating Total depth from original grade 4 GPD/SF Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot Southpark 1 5 Ft. Ft. Fill added above original grade Gravelength Township Range Section Ft. Ft. Gravel width Beds: Number of Lines Distance between lines SEPARATION DISTANCES Ft. FL To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line Ftz Ft. Well ! N (\l�c NA NA Iv TANK Septic ❑ S.T.E.P. ❑Holding [I Other II Manufacturer Capacity Surface Water 100'+ 100'+ NA NA GREER 1250 Gal. Material Number of compartments Lot Line 10'+ 10'+ NA NA NA HDPE 2 Foundation 10'+ 10'+ NA NA LIFT STATION- Manufacturer TATIONManufacturer Capacity Remarks Gal. Alarm location Electrical installed by PIPE MATERIAL House to tank 3034 Tank to3034 Installer drainfield Dean Construction Drainfield Co/MT3034 Inspector Pannone Engineering BENCH MARK (Assumed elevation) 220 ft Inspection 51 Location anddescri tion dates: /t� O 2nd /V 3 � p 3rd 4m Basement FF ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp Conditional Approval: Date` OFA( P OO 0 49 TH��� Steven .P. P-an'rion' e Septic System �� �; . E J149 Approved Date Note: this approval does not include well permit requirements. (Ppv nFir9r1 A% -iz� oo N=CO 0 € CO = z m � K: 0 C-) m -0 -H rlrZ CU D O Or-x�m I �fT1�7— z c: c FA O � AE n N --i N O r >ILn0r-z xD N O 0 v -� c� £ m p m z 9 c z m -Ci `r' Z I - cn 0) 0) N .. 1711 mXnzz cn ,, 03 o cn y o�nD r O z cn 07 v N 'n ^ (n .70 z mD O m o zc D rrrr*m m o� O cn ;u ri O -{ 1 p Z - .M ;oNP W �p CD � n i m rn i- i0 a m \ :;u U) m m X rn i S z II D /mi / N r / m / / D /D m . / 0 m o / (n m / m 0Ln 0 no / o / C) / o m C-) / z / / om C_A._Esynt / / _ C.E. Ln�' o / / i Cnm Z m CD / / � ' N :m N / N / /i CD I I ro o o / c:) CA o N < / NOTES: PANNONE ENG SVC LLC (C.I. 10$$) REVISIONS DATE RECORD DRAWING P.O. BOX 1807 645 PHONE (9077) 745-8200 FAXMER, (907)AK 9745-8201 SCA E22/2021 SOUTHPARK B1 L5 .............. P.I.D. NO 020-491-05 DRAWN MJL WILLIAM & PATRICIA SCHRECK 9I— R. Ponnono ; 16120 TERRACEWOOD LANE CE 8149 PERMIT N0. 4 '`Z(C OSP201401 SITE PLAN ANCHORAGE, AK 99516 �`' SHEET 1 of 1 I Lot 6 T 10' CEA Easement f (Book 595, pg 559) S89055'00" W 212,90 ' SCALE: V= 40' 7(9 \ •O1> Tract B OF , 44 4B �.� 49th o,•. Elizabeth L. Walatka �srFp • ' 8036 — LS • • a4 AW OFESSIONAt-•� maim 1 • Q�Q Cb i-- C*V 00 1.11 o©• �J J�� 5d / 00 /Q /tv EASEMENTS OF RECORD, OTHER THAN fit; .• ry-f THOSE SHOWN ON THE RECORDED FB 21-5, pg 66 PLAT ARE NOT SHOWN HEREON. FB 20-2, pg 59-60 UNLESS OTHERWISE NOTED FB 86-3, pg 7 BE RECERTIFIED 9-29-21& NO C4 RNERS SET THIS DATE I hereby certify that I have performed a Mortgagee's inspection in accordance with ASPLS Standards of the following described property: LOT 5 BLOCK 1 SOUTHPARK SUBDIVISION Anchorage Recording Precinct, Alaska, and that the improvements situated thereon are within the property lines and do not overlap or encroach on the property lying adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission lines or other visible easements on said property except as indicated hereon. Dated at Anchorage, Alaska this 10th day of September, 1986. FRED WALATKA & ASSOCIATES, L.L.C. 907-248-1666 Engineers and Surveyors This drawing is a representation of conditions found at the time the mortgage location survey was performed. This document does not constitute a boundary survey and is subject to any inaccuracies that a subsequent boundary survey may disclose. The information contained on this drawing shall not be used to establish any fence. structure or other improvements. This drawing shall only be used for a single property transaction. Use of this drawing by the original client or by others at a later date without the consent of Elizabeth L. Walatka is a violation of Federal Copyright law. Unless gross negligence is discovered, the liability extent of the preparer is limited to the amount of fees collected for services in preparation of this product. MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http:/Iwww.muni.org/onsite Permit Number: OSP201401 Effective Date: Work Type: SepticTank Upgrade Expiration Date: Tax Code Number: 02049105000 Site Legal Address: SOUTHPARK BLK I LT 5 G.-3236 Site Mailing Address: 16120 TERRACEWOOD LN, Anchorage Owner: SCHRECK WILLIAM R & PATRICIA A Lot Size in Sq Ft: Design Engineer: PANNONE ENGINEERING SERVICES Total Bedrooms: 9/25/2021 171 Disposal Field Z Septic Tank 0 Holding Tank 11 Privy El Private Well 171 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing fi�� Issued By: Date: T� YX 9 \ E. Date: is Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201401, Rebecca Carroll, 09/25/20 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201401, Rebecca Carroll, 09/25/20 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201401, Rebecca Carroll, 09/25/20 72-013 (Rev. 3/78) MUNICIPALITY OF ANCHORAGEI. DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAMEPHONE NEW LLt MI S 866—/ 70/_76419 I ❑UPGRADE MAILING ADDRESS /C Al/- = 26cil 6406)31RD 0AJC-l0, &' LEGAL DESCRIPTION r L 0r �7 13111' 1 96u't PAR11 TPAI3 W , °3 mo yy� LOCATION NO. OF BEDROOMS TeRPKE funis j . els Ll' Well ^6L(C Absorption area Dwelling PE IT NO. Uy DISTANCE TO: 2Y� t '� %'t]rngc� '!l �fC2 'tG8 i Q w F. Manufacturer>. ��,�, tj (T of Matg{i J No, of corypartments C rn Liq. capacity in gallons l2; IF HOMEMADE:Inside length Width Liquid depth <7 �' DISTANCE TO: Well Dwelling PERMIT NO. O z F Manufacturer Material Liquid capacity in gallons O WellIditr'y�iC Foundation Nearest lone f PER ITNO w= DISTANCE TO: .rte r'11U5Zi J LL Z No. of lines Length of each lirle Total leytth oflipes Trench wiSJth t Distare t veen lines P Z w Ci q' lnekee G H Top of tile to finish grade / Material beneath tile / Total effec�a$sbrp ion area 'k p inches Length Width Depth PERMIT NO. w Q F Type of crib Crib diameter Crib depth Total effective absorption area W a m Well Building foundation Nearest lot line DISTANCE TO: - Class P040C Depth Driller Distance to lot line PERMIT NO. J Y w � Building foundation Sewer line Septictank Absorption area(s) DISTANCE TO: OTHER NPL Zr t n C. /� PIPE MATERIALS D363'* SOI L TEST RATING f INSTALLER 6-f0/VjL REMARKS I<US'ULA'Tl A� O -I . LNG/ I' 2C FAr3Rit pUER'rRenfefa GiQY+UL4 AEPr1f Rr-DOcEALE µ c 7 UG 'r2 el EXCESLiV C 9 0 Al S PEC_'rE: 0 N 4� *0A4J W 6A-tc - �s QC EL Pcw dv S . W I IIIA PPRO D DATE LEGAL fV 6 g/?e/9, LS 4 1 soutl, PAR /T y 72-013 (Rev. 3/78) DEPARTMENT OF HEALTH AND ENVIRONMENTALPROTECTION 825 L STREET. ANCHORAGE, AK 99501 � 264-4720 F� H:F; t°7 Y -r ;PERMIT NO: 840468 DATE ISSUED: 06/16/84 APPLICANT ADDRESS: 'CONTACT PHONE LEGAL DESCRIP LOT SIZE: MAX BEDROOMS WILLIAM B. SCHNECK 2601 BLUEBERRY ROAD ANCHORAGE, AK 99503 276-7048 SUBDIVISION: SOUTH PARK SECTION: 3 TOWNJSHIP: i1N 34463 (SQ. FT. OR ACRES) 4 LISTED BELOW ARE THE OPTIONS AVAILABLE TO SYSTEM. CHOOSE THE OPTION THAT BEST FITS - - - - - - - - - - - - - - -IF FP- F= 1-4 C: DEPTH TO PIPE BOTTOM (FT.) 4.0 GRAVEL DEPTH (FT.) 10.0 TOTAL DEPTH (FT.) 14.0 GRAVEL WIDTH (FT.) 2.5 GRAVEL LENGTH {FT. ) 17.0 GRAVEL VOLUME (CU.YDS.) 16.5 TANK SIZE (GALS) :b250.0 W F: SOIL RATING (SO. FT. /BR) 85 LOT: 5 BLOCK: 1 ' RANGE: 3•.I YOU IN DESIGNINJG YOUR SEPTIC YOUR SITE. F= E L} 1--4 _ 0- Fc B:=i I r -a 5.0 0 0.5 5 5.5 S.G. 0 32.0 0 18. 9 1, 250. 0 i 85 85 *:* TANK MUST HAVE AT LEAST TWO COMPARTMENTS 4. 0 3. 5 7.5 c 0 37. 0 27,4 1, 250. 0 85 I CERTIF7` THAT: 1. I AM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE '_E14ERS AND WELLS AS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE (NOR) AND THE STATE OF ALASKA. 2. I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH ALL MOA CODES AND REGULATIONS, AND IN COMPLIANCE WITH THE DESIGN•d CRITERIA OF THIS PERMIT. _. I WILL ADHERE TO ALL MOA AND STATE OF ALASKA REQUIREMENTS FOR THE SET BACK DISTANJCE^S• FROM ANY EXISTINJG WELL, WASTEWATER DISPOSAL SYSTEM OR PUBLIC SEWERAGE SYSTEM ON THIS OR ANY ADJACENT OR NEARBY LOT. 4. I UNDERSTAND THAT THI_ PERMIT IS VALID FOR A MAXIMUM OF 4 BEDROOMS AND ANY ENLARGEMENT WILL REQUIRE AN ADDITIONAL PERMIT. IF A LIFT STATION IS INSTALLED IN AN AREA COVERED BY MOA BUILDING CODES, THEN (1) AN ELECTRICAL PERMIT AND INSPECTION MUST BE OBTAINED; (2) AS-BUILTS WILL NOT BE APPROVED WITHOUT AN ELECTRICAL INSPECTION REPORT; AND (3) THE ELECTRICAL WORK MUST BE DONE BY A LICENSED ELEC:TRICIANJ. SIGNED -- DATE: _ , -----------�-- ----- APPLICANT: WILLIAM B. '=CHNJECK rL ISSUED BY ��4i�2 DATE: ------------- SOILS LOG MUNICIPALITY OF ANCHORAGE l�I 11 DEPARTMENT OF HEALTH AND ENVIRONMENTAL_ PROTECTION PERCOLATION TEST 825 L. Street, Anchorage, Alaska 99501 264.4720 SOILS LOG — PERCOLATION TEST SW PERFORMED FOR: "rSYl1*" `.JG �rP K �? DATE PERFORMED: LEGAL DESCRIPTION: Sb r� / ' '' '--' kG/- I �—`-' •� RI OPE SITE PLAN - ./ 8a� WAS GROUND WATER S ENCOUNTERED?� L L O P E IF YES, AT WHAT DEPTH? lF I ET I OL n.-y.AZQ S'Oi 1 Reading Date Time 2 i I 3 9 eoo'V43 �9� 4 III=IN I n ■■ C V' �lcun �Y�yCJ 6- 7 PAST; �•� 8 (% y 9 10 11 id, Jr. ; 12 U�1 ® T a•• No 22 13 14- g� pROFES 15- 6 RE 16 rq9 17 i f C 18 19 20 ./ 8a� WAS GROUND WATER S ENCOUNTERED?� L L O P E IF YES, AT WHAT DEPTH? 11 (tYt d.2 5 ME Gross Net Depth to Net Reading Date Time Time Wai�q`a�6 ME 9 eoo'V43 �9� III=IN ��b••••eooa . n ■■ Lero C R id, Jr. ; ® T a•• No 22 1-E - g� pROFES RE 11 (tYt d.2 5 PERCOLATION RATE TEST RUN BETWEEN PERFORMED BY:%��L'FY SrF���`�CERTIFIED 72-008 (6/79) (minutes/inch) FT ANDFT �•t '6S 17`1A Gross Net Depth to Net Reading Date Time Time Wai�q`a�6 Gi Drop 9 eoo'V43 �9� ��b••••eooa . n Lero C R id, Jr. ; ® T a•• No 22 1-E - g� pROFES PERCOLATION RATE TEST RUN BETWEEN PERFORMED BY:%��L'FY SrF���`�CERTIFIED 72-008 (6/79) (minutes/inch) FT ANDFT �•t '6S 17`1A } ALASKA ei OROWnTAL COnTROL SRUIC65, InC. Engineering & 6nuironmenial Studies October 30, 1984 Department of Health and Envirommntal Protection 825 L Street/Fourth Floor Anchorage, Alaska Attention: Keith Bandt Subject: South Park Subdivision, Block 5 - Lot 1 Dear Keith: This office visited subject lot on October 5, 1984 to witness procedures for well abandonment. 12 cubic feet of concrete was poured into casing, casing was sealed and backfilled 4 feet below ground. Attached are pictures, during and after abandonment. If you have any questions, feel free to contact m? at our office. Sincerely, John W. Gates Engineering Technician 1200 West 33rd Auenue, Suite B • Anchorage, A66 99503 9 (907) 561-5040 A -Z Aft i ALASKA BUIRM611TAL C011TROL WU1CCs, Inc. Cngineerinq & 6nuironmental Studies October 24, 1985 Department of Health & Human Services 825 L. Street Anchorage, Alaska 99501 Re: South Park Subdivision Block 1 Lot 5 Subject lot has been submitted under the wrong legal description. The legal under which it was submitted is South Park Add. No. 1, Block 1, Lot 5. The.correc't legal should be ISouth Park Subdivision, Block 1,, Lot 5. The name of the owner `for said lot is William'Schreck. The permit was isued under the correct legal but the inspection report, dated 8/28/84, was completed under the incorrect one. Please take note of this correction for your files. Thank you for your time and consideration. Sincerely C>`=- Leroy . Reid, Jr., P.E. MUNICIPALIi 1 0,= DEPT. OF HEAL7: i L CNVIRONMEmAt. KCIEC71Ci'( j -81J RECE1VLD 1200 West 33rd Auenue, Suite B • Anchoraqe, Alaska 99503 • (907) 561-5040 Ur 1UPALITY OF ANCHORAC-1-E Development Services Department ; Phone: 907-343-7904 On -Site Wafter & Wastewater Section � Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 020-491-05 'I. GENERAL INFORMATION Complete legal description Southpark B1 L5 Location (site address) 16120 Terracewood Lane Expiration Date: / 0 - Z (a - 20 Z3 Current property owner(s) 6, l i scl rrDay phone Mailing address Real estate agent 2. T'�, PE OF DWELLING: Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 Day phone 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well ❑ Private Septic 0 Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System 0 Public Sewer ❑ Waiver request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee s_55 0 Waiver Fee $ Date of Payment 3//A_L Date of Payment Receipt Number __(2// y 6 r- Receipt Number COSA # 0 Is C, A S I 5 Waiver # 6. S T A T EIMEN T OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in accordance with MOP, COSA guidelines and regulations. The reported results describe the performance of the system under the conditions encountered at the time of the test. and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition, ground water levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. Therefore we cannot provide any warranty for future performance. nor can we estimate remaining life of the system. The content of this report is for the sole benefit of the owner listed above. Reliance on this report by another person is at their own risk. Pannone Engineering Services LLC highly recommends buyers hire their own engineer to evaluate this report. Name of Firm Pannone Engineering Services Address P.O. Box 1807 Palmer, AK 99645 Engineer's Printed Name Steven R. Pannone P.E., F. ACE 6. DSL' SIGN TUPE - - System #1 Approved for bedrooms System #2 Approved for bedrooms Disapproved Phone (907) 745-8200 Date OF A1 49 THy Vj rA Stever i i''c irore W Aw Conditional approval for bedrooms, with the following stipulations: J - R ANp � CD WAST taV\lAT o JJJ�iiNNT SERN�G �N`\\,� � 22 3 Original Certificate Date: 3- - Z OZZ The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. A a TACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist blue sheet t; C A C h e c k Ii 1612 Legal Description. 0 Terracewood Lane Parcel ID: 020-491-05 If more than `i septic system on lot: COSA Checklist # 1 of 1 Structure served by this system 1 A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Comments Public water D. TANK DATA 10131 x Age of tank(s) years Tank type/material "°'""""` Measured operating fluid level in septic tank new Standpipes/foundation cleanout per record drawing Date of pumping 10/12/21 D. ABSORPTION FIELD DATA Deep Trench Which system tested (date installed) 8128184 0 ALL standpipes present per record drawing Total measured depth from grade 1 ax) Measured depth to pipe invert from grade 8 ft (min) ❑ N/A — pressurized field © Monitor tubes go to bottom of effective. If not, state depth into effective n Code -required soil cover over field ❑ System presoaked (Required if vacant for greater than 30 days prior to date of test) Gallons introduced gallons Comments/Deficiencies: COSA Checklist yellow sheet Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? ❑ Yes ❑ No ❑ Coliform bacteria is Negative Nitrate mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ❑ Arsenic less than MRL (ND) Collected by _ Date of Sample C. LIFT STATION ❑ Required maintenance completed Age of lift station years Lift station material Comments: Adequacy test date 10/26/21 Results [Z]Pass For 4 bedrooms Fluid depth prior to test 0" in Water added 600 gal New depth 1" in Elapsed time 110 min Final fluid depth 0 in Absorption rate 600+ gpd Any rejuvenation treatment (past 12 months) If yes, enter date E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' Yes Community Sewer Manhole/Cleanout > 100' ft ❑ Yes if No ft (D Yes if No ft Neighboring Tank > 100' ❑ Yes if No ft Private Sewer/Septic Line > 250 Yes if No x Absorption Field on Lot > 100' ❑ Yes if No ft Holding Tank > 100' ❑ Yes if No ft Neighboring Absorption Fields > 100' Surface Water > 100'✓Q Animal Containment > 50' ❑ Yes if No ft ft ❑ Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' F-1 Yes if No ft ❑ Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10'[]✓ Yes if No ft Surface Water > 100' Q✓ Yes if No ft Property Line > 5' Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' Q✓ Yes if No ft Private Wells > 100' Yes if No ft -- --VVater Mai n > 10' Yes if No ft Community Wells > 200' []✓ Yes if No ft Water Service Line > 10' ❑✓ Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required Building Foundation > 10' Yes if No ft If absorption field is under driveway comment below Property Line > 10' ❑✓ Yes if No ft Wells on Adjacent Lots: Water'Main > 10' F1 Yes if No ft Private Wells > 100' Yes if No ft Water Service Line > 10' Q Yes if No ft Community Wells > 200' Yes if No ft Surface Water > 100'✓Q Yes if No ft F. ENGINEER'S COMMENTS G. ENGINEER'S CERTIFICATION I certify that 1 have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. 2202.�� COSA Checklist yellow sheet �� OF Asti ��� MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 020-491-05 1. GENERAL INFORMATION Expiration Date: C1 Complete legal description South Park B1 L5 Location (site address) 16120 Terracewood Ln, Anchorage, AK 99518 Current property owners) Bill Schreck Day phone Mailing address Real estate agent Day phone 2. TYPE OF DWELLING: Fx7l Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well ❑ Private Septic n Water Storage ❑ Holding Tank ❑ Community Well Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ Waiver Fee $ _ Date of Payment Date of Payment Receipt Number Receipt Number COSA # _ Waiver # OSG 1$ 1 Lt O�g 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in accordance with MoA COSA guidelines and regulations. The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition, ground water levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. Therefore we cannot provide any warranty for future performance, nor can we estimate remaining life of the system. The content of this report is for the sole benefit of the owner listed above. Reliance on this report by another person is at their own risk. Pannone Engineering Services LLC highly recommends buyers hire their own engineer to evaluate this report. Name of Firm Pannone Engineering Services Phone (907) 745-8200 Address P.O. Box 1807 Palmer, AK 99645 Engineer's Printed Name Steven R. Pannone P.E. Date 6 Qov2% OF Akq J� S ' TH 6. DSD SIGNATURE • • . System #1 Approved for y bedrooms Steven R: inn'one cE 8314,_9 . System #2 Approved for bedrooms Disapproved Conditional approval for bedrooms, with the following stipulations: Ie 5 enil'c' Carl k 1,5 31 VY -5 OIa Avera o ,`����l %O,C:��i� M m O -70 ��; )) 1 By:/L%G✓ �� J �m j5ckJ,n�� Original Certificate Date: ZLl �g The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineers work. 7. ATTACHMENTS: COSA Checklist X Septic System Advisory Well Flow Advisory COSA Checklist blue sheet Nitrate Advisory Arsenic Advisory Other _[pink 0,qe a 015,50ry COSA Checklist Legal Description: South Park 131 L5 Parcel ID: 020-491-05 If more than I septic system on lot: COSA Checklist # of Structure served by this system A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Comments B. TANK DATA Age of tank(s) 34 years Tank type/material s�o:uswo Measured operating fluid level in septic tank MR Standpipes/foundation cleanout per record drawing Date of pumping 8/20/19 D. ABSORPTION FIELD DATA Deep Trench Which system tested (date installed) X ALL standpipes present per record drawing Total measured depth from grade 29.5 ft (max) Measured depth to pipe invert from grade 8 ft (min) ❑ N/A — pressurized field Q Monitor tubes go to bottom of effective. If not, state depth into effective RE -1 Code -required soil cover over field ❑ System presoaked (Required if vacant for greater than 30 days prior to date of test) Gallons introduced gallons Comments/Deficiencies: COSA Checklist yellow sheet Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? ❑ Yes ❑ Nc ❑ Coliform bacteria is Negative Nitrate mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ❑ Arsenic less than MRL (ND) Collected by _ Date of Sample C. LIFT STATION ❑ Required maintenance completed Age of lift station years Lift station material Comments: Adequacy test date 9/14/18 Results [DPass For 40 bedrooms Fluid depth prior to test 0 in Water added 600 gal New depth 0 in Elapsed time 110 min Final fluid depth 0 in Absorption rate 600+ gpd Any rejuvenation treatment (past 12 months) If yes, enter date E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' F✓ Yes Community Sewer Manhole/Cleanout > 100' M✓ Yes if No ft ❑✓ Yes if No ft Neighboring Tank > 100' M✓ Yes if No ft Private Sewer/Septic Line > 25'✓Q Yes if No ft Absorption Field on Lot > 100' M Yes if No ft Holding Tank > 100' [✓ Yes if No • ft Neighboring Absorption Fields > 100' Yes if No ft Water Main > 10' Animal Containment > 50' M Yes if No ft ✓0 Yes if No ft Q✓ Yes if No ft Water Service Line > 10'✓Q Yes if No Manure/Animal Excreta Storage > 100' If septic tank is under driveway comment below Community Sewer Main > 75' ✓� Yes if No ft rVJ Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' F✓ Yes if No ft Surface Water > 100' Q✓ Yes if No ft Property Line > 5' Yes Yes if No ft Wells on Adjacent Lots: P-1 Absorption Field > 5' if No Yes if No ft Private Wells > 100' Yes if No ft Water Main > 10' ft Yes if No ft Community Wells > 200' Q✓ Yes if No ft Water Service Line > 10'✓Q Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' E✓ Yes if No ft If absorption field is under driveway comment below Property Line > 10' ❑✓ Yes if No ft Wells on Adjacent Lots: Water Main > 10' P-1 Yes if No ft Private Wells > 100' Yes if No ft Water Service Line > 10' ❑✓ Yes if No ft Community Wells > 200' M Yes if No ft Surface Water > 100' ✓D Yes if No ft F. ENGINEER'S COMMENTS G. ENGINEER'S CERTIFICATION I certify that l have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. / !Zen ?=q COSA Checklist yellow sheet �.. 9IL .-.. Septic 'Tank Advisory Certificate of On -Site Systems Approval # OSC181498 Subdivision: South Park Block:1, Lot: 5 The septic tank for this property is 35 years old. The average life for a steel septic tank is 20 years. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. This is an example of what the metal of a 30 year old steel tank MAY look like. v M�! hAr1dr�Ss�0��r565t}a*agcia +eAlka55"FIVwsniinl r�� X EPtAtAS/ ea A • • t Municipality �g of Anchorage On-Site Water and Wastewater Program (907)343-7904 �d11.� Certificate of On-Site Systems Approval / Parcel I.D. 020-491-05 Expiration Date: v 1 J^( 7 1. GENERAL INFORMATION Complete legal description South Park B1 L5 Location (site address) 16120 Terracewood Ln. Anchorage, AK 99516 Current Property owner(s) Bill Schreck Day phone Mailing address 16120 Terracewood Ln. Anchorage, AK 99516 Real Estate Agent Day phone 2. TYPE OF DWELLING: O Single Family(w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual Individual Water Storage ❑ Holding Tank ❑ Community Class Well Q Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: Received b . 1► t I I Date:4,a4t_ COSA to be released to the engineer,unless otherwise requested by the engineer. COSA Fee $ 5240 Waiver Fee $ Date of Payment 9PO`rg Date of Payment Receipt Number ao ,na�c."/� Receipt Number COSA# o l g l'-Q0 Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply andfor wastewater disposal system is (are)safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection,the on-site water supply and/or wastewater disposal system is(are)in compliance with all applicable Municipal and State codes,ordinances,and regulations in effect at the time of installation. In conducting an adequacy test,I attempt to provide a thorough,conscientious engineering analysis of the system in accordance with MoA COSA guidelines and regulations.The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition,ground water levels that may fluctuate during the year,and the water usage of the family being served by the system.These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future performance of the system,nor do they guarantee that there are no hidden defects or encroachments.Therefore we cannot provide any warranty for future performance, nor can we estimate remaining life of the system.The content of this report is for the sole benefit of the owner listed above. Name of Firm Pannone Engineering Services LLC Phone (907) 745-8200 Address P.O. Box 1807 Palmer, AK 99645 Engineer's Printed Name Steven R Pannone Date 9/19/2018 fl .•odif 03.* � • !F 6. DSD SIGNATURE %:*••�`TH 40 N�` VA ra System#1 Approved for II bedrooms li • even •.•Isannorie System#2 Approved for bedrooms 00{ '• CE-8149 .•.43. \----- Disapproved �1,, R?p}TSSt - `7 Ai Conditional approval for bedrooms,wi`thh the following stipulations: I I - ' -0 Q Si-82f S is `k- c i. zo zl�vt• ( � cee ' P. t/t.c • rev QPM\� ., z 0N_S\VE p ", N m NIP PEER o N1 PS RPM : �- PR°G o " er) \& -_fir '1PNT(S��F BY ` Wk.C Original Certificate Date: C�� r —( t5 The Municipality of Anchorage Development Services Division (DSD)issues Certificates of On-Site Systems Approval (COSA)based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic AcJ„visory Well Flow Advisory Other 7( COSA blue sheet t . - If more than 1 septic system is on the lot: COSA Checklist# 1 of 1 Structure served by this system 1 Certificate of On-Site Systems Approval Checklist Legal Description: South Park B1 L5 Parcel ID:020-491-05 A. WELL DATA Well type Community If A, B, or C provide PWSID# 213475 Well Log(YIN) Date completed Sanitary seal (YIN) Wires properly protected(Y/N) Total depth ft. Cased to ft. Casing height(above ground) in. FROM WELL LOG AT INSPECTION Date of test Static water level ft. ft. Well production g.p.m. g.p.m. WATER SAMPLE RESULTS: Coliform colonies/100 mL Nitrate mg/L Arsenic ug/L Date of sample: Collected by: B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Date installed 8/28/84 Tank size 1250 gal. Number of Compartments 2 Cleanouts(YIN) Y Foundation cleanout(Y/N) Y Depression over tank(YIN) N High water alarm(Y/N) N/A Date of pumping 8/13/2018 Pumper Isaac's Pumping Service C. ABSORPTION FIELD DATA Date installed 8/28/84 Soil rating (g.p.d./ft2 or ft2/bdrm) 85 System type Deep Trench Length 29.5 ft. Width 4 ft. Gravel below pipe 8 ft. Total depth 14 ft. Eff. absorption area 472 ft2 Monitoring tube Y Depression over field N Date of adequacy test 9/14/18 Results(Pass/Fail) Pass For 4 bedrooms Fluid depth in absorption field before test 0 in. Water added 600 gal. New depth 0 in. Elapsed Time: 1 10 min. Final fluid depth 0 in. Absorption rate >= 600+ g.p.d. Any rejuvenation treatment(past 12 mo.)(Y/N&type) Non Known If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access(YIN) "Pump on"level at in. "Pump off'level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot 100 + On adjacent lots 1001+ Absorption field on lot 1001+ On adjacent lots 1001+ Public sewer main 75'+ Public sewer manhole/cleanout 1001+ Sewer/septic service line 25'+ Holding tank 100 + Animal containment areas 50 + Manure/animal excrete storage areas 100'+ SEPTIC/HOLDING TANK ON LOT TO: Building foundation 101+ Property line 101+ Absorption field 101+ Water main 251+ Water service line 251+ Surface water 100'+ Wells on adjacent lots 1001+ ABSORPTION FIELD ON LOT TO: Property line 101+ Building foundation 101+ Water main 10 + Water Service line 25'+ Surface water 1001+ Driveway,parking/vehicle storage 101+ Curtain drain 501+ Wells on adjacent lots 1001+ F. COMMENTS Tank levels are normal. G. ENGINEER'S CERTIFICATION —�`,eo��it ,c of A�,�sek I certify that I have determined through field inspections and X0"4:•:• Ni..."--4. -V I. review of Municipal records that the above systems are in ,O*.r • I`., •*, conformance with MOA COSA guidelines in effect on this date. •••• N i0 Engineer's Printed Name Steven Pannone /•...Sleveri IR.•hririone..•' Date 9/18/2018 61:,-.,. E-81424 e COSA canary sheet_2-6-15.doc • • i( 1 • I I f '1• y: • 1....:: ::•-")/k.)17... re,I lel p' P;.//y1)'.I'" ?i Sy '..ity� R.I • • 1 `+; �'� Cyn 4 ,r, } - 1 • I t y-' t-._ 5:. 1. is V. j w;�,e (i 't, I, '-, ... i I . \ . 4 /t•. iw 4. ate•. _ •• .\ f 1 i/g< �` y�• .i-n `N. j ;t :1 n r ,`. e� f, t . / .,,, .). • AS-BUILT NO CORNERS SET THIS DATEV / .o.'"'�•p a e�t1 • �F �� I hereby certify that I have performed a Mortagee's in- ..s. (£,.......,t 4 h —� e a Ak.-' . s t spection of the following described property: _ i .er..c_-._- ` J• 0et*r49.TNr :,�;4 -• •• 'I ];/J :1-1r,-;,÷.„‹ ft y�. t4 Anchorage Recording Precinct,Alaska,and that the improve- CR`_'Iz... -1r, .+-,c d menta situated thereon are nithin the property lines and do E lignot overlap or encroach on thepatying adjacent there- `"`"` to, that no improvements on ying adjacent thereto 1 4 `', . NO. 325,$ • ;-.0" encroach on the premises in question and that there are no Z .,, ,- .m roadways, transmission lines or other visible easements on /� s a . s I�",:oaf- ..-4.0.* .=- w said property except as indicated hereon. "Seale i ,,0 i.:S';;:t.L. Dated at Anchorage,Alaska `OZ,tNe ,�gxa. thix / 'th da• y of . ,o rn19_x /E' ie:r !r; __ EASEMENTS OF RECORD, OTHER THAN _ THOSE SHOWN ON THE RECORDED FRED WALATKA& ASSOCIATES PLAT ARE NOT SHOWN HEREON. o�_v p ��t/ Engineers and Surveyors 3, n MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION DIVISION OF ENVIRONMENTAL HEALTH CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY 264-4720 Q Application Date 1. GENERAL INFORMATION 0 (a) Legal Description (include lot, block, subdivision, section, township, range) Location (address or directions) (b) Applicant Name 4VIZ1 410 SCI-146�K Telephone: Home 7 ZS �7 Business Z7 - 70 7/� � Applicant Address ? �� �/, �� §4 (c) Applicant is (check one): Lending Institution ❑ ; Owner/builder ,NS : Buyer ❑ ;Other ❑ (explain); (d) Lending Institution 1:1 kko 4(�R FEDfCk, i' ,IlAlt l'Telephone 7S,3-0� 0 Address CRE'DI i-/ L t!/ /i/ R/y (e) Real Estate Company and Agent Address Telephone (f) Mail the HAA to the following ( Lz> G� IJ 2. TYPE OF RESIDENCE Single-Familyfg[ Multi -Family❑ Other Number of Bedrooms A 3. WATER SUPPLY Individual Well ❑ Community 5r Public ❑ il. X-1 CC - Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 4. SEWAGE DISPOSAL Onsite Public ❑ Community ❑ Holding Tank ❑ Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. Page 1 of 2 72-025 (11184) Z,_ 5. ,ENGINEERING FIRM PROVIDIN _ .NSPECTIONS, TESTS, FILE SEARCH, DA AND INFORMATION As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm AGC S Telephone Addre Date 6. DHEP APPROVAL " " �¢" bedrooms by �` Q / Date Approved for 4 Approved Ll� Disapproved Conditional Terms of Conditional Approval CAUTION The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 72-025 (11/84) I MUNICIPALITY U IALITY OF ANCHORAGE (MOA) a CI AUTHORITY APPROVAL (HAA) CHECKLIST - FEBRUARY 1984 f186t L iV V 264-4720 NOI1J31Oad 1VINWINOMIAN3 Legal Description: W H17W3H do 1d3a /'!AI A. WELL DATA 3OW10HJNW dO .1111VdIJINnw Well Classification COMMU/V/TY If A, B, C, D.E.C. Approved (Y/N) �U✓, S � � ��� 5 ��s Well Log Present (Y/N) Date Completed Yield Total Depth Cased to Static Water Level Casing Height Above Ground — Electrical Wiring in Conduit (Y/N) Separation Distances from Well: To Septic/Holding Tank on Lot To Nearest Edge of Absorption Field on To Nearest Public Sewer Line Cleanout/Manhole Water Sample Collected by Water Sample Test ResSPK Comments B. SEPTIC/HOLDING TANK DATA Depth of Grouting — Pump Set At Sanitary Seal on Casing )egression Around WQfB (Y/N) n Adjoining Lots — On Adjoining Lots To Nearest Public Sewer To Nearest Sewer Service Line on Lot Date Date Installed Size /Z�Q No. of Compartments Standpipes @N) Air -tight CapsON) Foundation CleanoutN) Depression over Tank (Y/O Date Last Pumped Pumping/Maintenance Contract on File (Y/N) ly/ ; for Holding Tank High -Water Alarm (Y/N) �Y.//� Temporary Holding Tank Permit (Y/N) Al Separation Distances from Septic/Holding Tank: 7 To Water -Supply Well 200 To Building Foundation To Property Line 20 To Disposal Field To Water Main/Service Line u ,5; To Stream, Pond, Lake, or Major Drainage Course Comments Page 1 of 2 72-026(11/84) Z__5 6/ .50o rli P'%RK %E�,RWc€ C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata `7 Type of System Design Date Installed 1��/eC1 Length of Field 2qs i ,y Width of Field Depth of Field Square Feel of Absorption Area Depression over Field (Y,&V Results of Last Adequacy Test Gravel Bed Thickness — Standpipes Present (DN) Date of Last Adequacy Test Separation Distance from Absorption Field: To Water -Supply Well To Properly Line__ To Building Foundation I V r To Existing or Abandoned System on Lot A/1 A On Adjoining Lots w i To Water Main/Service Line ys To Cutbank (if present) �± To Stream/Pond/Lake/or Major Drainage Course /OCJ 72' i t To Driveway, Parking Area, or Vehicle Storage Area 2,S Comments D. LIFT STATION Date Installed Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for Electrical Codes (Y/N) — Comments — Dimensions Manhole/Access (Y/N) "Pump evel at Vent(Y/N) ** Check Permitted Bedroom Rating Against HAA Request ** Pumping Cycles during Adequacy Test. Meets MOA Icertifythatlhav c e ced,ver'ied, conformed to all MOA and AA guidelines in effect on the date of this inspection. Signed Date — Company IkC,,5 MOA No. Receipt No. (o�V Date of Payment Amount: $ 1 C_) ', Al 64c#1Vte1vr5 Page 2 of 2 72-026 (11/84) 0U #Z SIDE P164 ALASKA bUIROWnTAL COnTROL SCRuIINS, InC. Engineerinq & enuironmental Studies December 17, 1986 Municipality of Anchorage Department of HHealth and Human Services 825 L Street, Suite 502 Anchorage, Alaska 99501 Attn: Steve Morris Re: Lot 5, Block 1, South Park Subdivision Dear Mr. Morris: ®IAIDT8 Leg L NV i NOIJ3110i1d JVIN3WNObIAN9 '8 H1lV3H d0 'ld3a 30V80H:)NV 40 ALI1VdIOINBW Our office performed a Health Authority inspection December 10, 1986, on the subject lot. This 4 bedroom single family dwelling has not been lived in yet. They are in the final stages of construction and a Certificate of Occupancy will not be issued until early in January. The current closing date is set for January 9, 1987. Since the system was put in over two years ago, your office requires an adequacy test or a Certificate of Occupancy. As per our phone conversation on December 17, 1986, we discussed that due to the close proximity of the issuance of the Certificate of Occupancy and closing date, that it would not be feasible to obtain Health Authority Approval in that amount of time. Therefore, based on our investigation, we request that Health Authority Approval be given for the subject lot without the Certificate of Occupancy. If you have any questions please feel free to call me at 561--5040. Sincerely, Jeff Kaitchuck Engineering Technician Approved: IF OY'F. REID, JR. -7 ig -2251 �~ kk 1200 Llest 33rd Auenue, Suite B • Anchorage, Alaska 99503 • (907) 561-5040 ALASKA ENVIRONM�NTAL 3kZ CONTROL SERVIC ; INC. 1200 West 33rd Avenue, Suite B ANCHORAGE, ALASKA 99503 (907) 561.5040 JOB L S B 1OG7'N PRRK TERRACE SHEET NO. 'f(/ OF CALCULATED BY J / " DATE CHECKED BY DATE BILL SHEFFIELD, GOVERNOR DEPT. OF ENVIRONMENTAL CONSERVATION Telephone: rson Address: ANCHORAGE/WESTERN DISTRICT OFFICE 437 "E" STREET, SUITE 303 ANCHORAGE, ALASKA 99501 DATE: December 8, 1986 PWS I.D.# 213475 274-2533 To Whom it May Concern: According to records on file in this office the SOUTH'BARK TERRACE SUBDIVISION Water System is in compliance with the State Drinking Water Regulations Sincerely, Michael P. Lewis Environmental Engineer G LOT 5, BLOCK 1 Soils and Ground Water Most of this lot is located on a hill mapped as the gm landform by the U.S.G.S. Test Boring 35, located on top of the knoll near the southern boundary of Lot 6, encountered layered clean sandy gravels and gravelly sands. Test Pit 23A, located on the base of the hill, also encountered similar soils. Thus the landform is probably a glacial alluvium. Glacial alluvium is defined on the Generalized Geologic Map of Anchorage as irregular shaped hills deposited in or near glacial ice consisting chiefly of gravel and sand, moderately well graded and moderately well sorted. Np— round water was observed in Test Hole 35 which was drilled to a 15 foot depth or in the test pits. Ground water seepage was noted from a depth of seven to eight feet in Test Hole 23A. Location of Septic System The preferred septic system drain field location is in the central part of the lot on the hillside or depending on the house location, on the top of the knoll. The septic system should be located as high up on the hill as feasible to avoid any ground water problems. Design Absorption Area A percolation test was performed in Test Boring 35 and the percola- tion rate was three minutes per inch. Based on criteria in the Manual of Septic Tank Practice, the required absorption area is 100 square feet per bedroom. If silty soils are encountered, the required absorption area must be increased. Test Hole #35 DDe th in Feet From To 0.0' 1.0' 1.0' - 15.0' Bottom of Test Hole: Frost Line: Free Water Level: Remarks: I Table A WO #A18753 Logged By: J.D. black Date: 1-17-79 Soil Description Organic Topsoil. Layered Sandy Gravels (GW) and gravels (GP). 15.0' None Observed Mone Observed Percolation test hole located on top of knob. Test Hole #23A Depth in Feet From To 0.0' - 2.0' 2.0' - 8.0' 8.0' - 10.0' Bottom of Test Hole: Frost Line: Free Water Level: Remarks: Table A Soil Descr. Topsoil. WO #A18753 Logged By: J.D. Mack Date: 1-9-79 Coarse Sandy Gravels, GP, NFS, wet. Silt, ML, F-4, damp. 10.0' None Observed 7.0'-8.0' only Test Hole 23A, 80' uphill from test hole #2.3, water seepage at 8'