Loading...
HomeMy WebLinkAboutTHUNDERBIRD FALLS LT 1Thunderbird Falls Lot 1 051-411-04 EXPIRED PERMIT Municipality of Anchorage o •. i 1'.n. n1AC t�1)Al)) • And... ' 1c..).lusluk ��l l�'(�1(Fln • Telephone (907) 3t3'SM)1 • I'La (tX)7) S31'S:(K) ` my T ` zFr ¢r• 47(11)[Smgmr S)rcct •.Vjc6nrngc..\kts1:a x'+07 ullwnwnlmrg Hayor Mark Begich Bttildin� S<tfcty Dit3ston 23 May 07 Norm Campbell PO BOX 1310 Estavada, OR 97023 Subject: Expired On -Site Water and/or Wastewater Permit Permit Number: SW060175 Legal Description: Thunderbird Falls Lot 1 Dear Mr. Owens: An On -Site Water/Wastewater Permit, number SW060175 issued by this office for a single-family system, will expire on 23 June 07. Permits are valid for 365 calendar days from date of issue. If this was a well permit and the well has been drilled, a well log and a pump install log must be sent to this office for documentation of the installation and to close the permit. If this permit was for a wastewater disposal system, an original as -built inspection report must be sent to this office for review, approval and documentation. This as -built inspection report must be signed by the licensed Professional Engineer who inspected the installation of the system. As -built inspection reports are required to be submitted within 30 days of the completion of the system. If no system was installed under this permit, and you are still planning to install a well or wastewater disposal system, a new permit must be obtained from this office. A one-time renewal fee for a second year may be issued for a $115.00 if the renewal application is received on or before the expiration date of the original permit. When applying for a new permit, the fees are $460.00 for a wastewater permit and $175.00 for a well permit. If you have any questions, please call this office at 343-7904. Sincerely, I �w - -­r� Daniel J. Roth Program Manager On -Site Water and Wastewater Program Enc: Copy of permit Con>,nutnity, Security, Prosperity MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water d Wastewater Program `1 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650n 1Ct `(D (907) 343-7904 v1 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Permit Number: SW060175 Date Issued: Jun 23, 2006 Expiration Date: Jun 23, 2007 Parcel ID: 051411-04 Legal Description: THUNDERBIRD FALLS LT 1 Design Engineer: 0848 EAGLE RIVER ENGINEERING SEI Site Address: Owner Name: NORM CAMPBELL Lot Size: 72745 SO. FT. Owner Address: PO BOX 1310 Total Bedrooms: 3 Permit Bedrooms: 3 ESTACADA , OR 97023-0000 This permit is for the construction of: ❑✓ Disposal Field r7j Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Date: G /2 Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 ON-SITE SEPTICMELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. Property phone 4L41 - ME Mailing address PD ECX 1516Z. {5 E604Z& Zip Code 9aoa3 Site address ,1c.H (OS araCli)r Lane ( un; crk, AYZip Code XI e) s(, -i Legal description (Sub'd, Block & Lot) _m"VIcic rbi re/ Feal't- , L 1 Legal description (Township, Section & Range) —r I U A/ ►'—I 1,U 5�e� EL Lot Size 7A, l 115 Sq. Ft. THIS APPLICATION IS FOR (®all that apply): Absorption Field rX, Septic Tank Holding Tank ❑ Privy f/ Private Well Lld Water Storage ❑ Number of Bedrooms 3 THIS APPLICATION IS AN: Initial Upgrade Renewal certify that the above information is correct. I further certify that this application is being made for a Single Family tSwelling go is inpccordange with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: ftq -f Waiver Fees: Date of Payment: G 1((,lcb Date of Payment: Receipt Number: 917 et 7 /,-a Receipt Number: (Rev. 11105) V/ " Eagle River Engineering Services Christopher R. Wood, P.E. 10421 VFW RD. Suite 201 (907) 694-5195 tel Eagle River, AK 99577 (907) 694-3297 fax June 14, 2006 Dan Roth Manager, On -Site Services Municipality of Anchorage P.O. Box 196650 Anchorage, AK 99519 Re: Thunderbird Falls Lot 1 Narrative & Permit Application Dear Mr. Roth: Eagle River Engineering Services (ERES) was contracted to design a 4 bedroom well and septic system at the above referenced property. A test hole and soils percolation test has yielded a fine, poorly graded silty sand from 5-16 feet below the ground surface, with a clayey silt and fine sand mix in the top 5 feet below the ground surface. The soil type appears adequate to support a primary and replacement 4 bedroom septic system, as long as the top of the leachfield is at a depth greater than 5'. The terrain is gently sloping at a rate of 10%-20% across the property, and the leachfields will be installed parallel to these slope contours. The proposed 4 bedroom septic system and well will have very limited impact on adjacent properties for the following reasons: 1. The surrounding lots are large, so there is room for wells, septic systems and alternate sites. 2. Immediate neighboring septic systems are all +20' distance, and no private (or community) wells within 100' of the proposed septic system. 4. Drainage will not be affected and is not a major consideration in our design. Installation of this 4 bedroom well and septic system, to our best available knowledge, will not adversely affect the wells or septic systems or reserve areas on adjacent lots. If you have any questions please call our office at 694-5195. Sincerely, ;instophWero LE E G SERVICES Principal \2003\06.017SEPTICNARRATI V E.DOC .'� \\\NSTRAIGHT PROPERTY \ \ S 89.59'00"E \ WEu+zoo \ sEPnc +3o•t 300.00' -----I- ----------- 10• UTILIASEMENT II --�---------- I I \ NO WELL+20C' PROPOSED II O NO SEPTIC +SO. WELL O rn I I I I I I 1 STATE^ -AND I i Pi Lob'1 n I bl �p p \�♦ I -� HOU'SESED i elm \ I � 0 1•: � • ISTALL NEW OI r I INSTALLI O •3• I I NEW 100 CAL SEPTIC TANK I I \ S 89 S9. 10' 5' X60' DRAINFlELD X 601 y.pyRESERVE SITE /`"J 1 „ RAONS / \ ` Np'CV10ay510o 11 `\ WELL I 7SURFACE Lot 21 SEPTIC +30' I 3p�Op•1. NO KNOWN WATER +100'. 1 2. NO KNOWN CURTAIN DRAINS ® - TEST HOLE — — - EASEMENT / • - MONITOR TUBE - Pji0PO5ED LEACH FIELD 0 _ S / EWER CLEAN ouT �� -/EXISTING LEACH FIELD + WELL ©7 DRIVEWAY WELL/SEPTIC SITE PLAN LEGAL: THUNDERBIRD FALLS LOT 1 OWNER: NORM CAMPBELL �P CONTRACTOR: MARTIN CONSTRUCTION Alt JOB 06-017 DATE: t5/8/2006 1 SCALE 1"=50' i EAGLE RIVER ENGINEERING P.O. Box 773294 EAGLE RIVER, AK. 99577 (907) 694-5195 FAX. (907) SERVICES lmu NEIGHBORS WEL 100' RADUIS 1 SEPTIC ARE II Lot 4 N 00 OF CE -10387 694-3297 ,I�111% �� EAGLE RIVER ENGINEERING SERVICES P.O. Box 773294 Eagle River, Alaska 99577 (907) 694-5195 ERES Project No.: 0"17 Calculated By: CB Date: 06/14/2006 Legal: THUNDERBIRD FALLS LOT 1 TEST HOLE Single Family 3 Bedroom Dwelling Shalbw Trench Subsurface Wastewater Disposal Flekl Water use at 150 gallons per bedroom = 450 gallons Percolation rate = 8 minutes per inch Wastewater application rate = 0.8 gallons per day per square foot Required absorption area = 563 square feet Trench width (W) = 5 feet Gravel depth (D) = 4 feet Required length = Shallow trench factor • Required absorption area / W Shallow trench factor = (W + 2) / (W + 1 +2 D) Shallow trench factor= 0.50 �J Total Excavation Depth = X.6 'feet Required length = 56 feet 115 �cto�t-D Da -P 06 -017T -b irddra i nfield. xls 11:40 AM06/1412006 Eagle River Engineering ,Services Christopher R. Wood, P.E. 10}21 VFW Rd. Suite 201 (907) 694-5195 tel Eagle River, AK 99577 (907) 694-3297 fax SPECIFICATIONS FOR ON-SITE SEPTIC SYSTEM LEGAL: Thunderbird Falb Lot 1 October 27, 2005 A. GENERAL 1. The well and septic plan is for a 4 bedroom single family residence only. 2. The drawing and or site plan shall be apart of this specification. 3. All materials and workmanship shall meet the Anchorage Department of Health and State Department of Environmental Conservation requirements. 4. All soil tests are advisory to the design and are to be verified or modified in the field by the engineer. 5. All excavations and depths are advisory and are to be verified in the field by the contractor to meet Municipality of Anchorage, Department of Environmental Conservation requirements. 6. It is the responsibility of the owner to obtain all necessary permits or easements and to locate any adjacent multi -family wells. 7. The excavation is to be exactly in the area shown on the site plan, any deviation requires engineer approval. 8. Any remaining open test hole excavations shall be filled and monitor tube removed. B. SEPTIC TANK I. The sewer piping from the house shall be 4" PVC 3034 laid at 2% grade maximum — 1% minimum and insulated with 2" of burial foam if shallower than 3 ft., with 2 ft. minimum. 2. Septic Tank shall be a minimum of 1,250 gallon tank of MOA approved construction, insulated, or place with 4' of soil cover, min. C. DRAINFIELD 1. The drainfield is to be placed as shown on the site plan. Contractor shall take extreme care ensure that I O'separtation distance is maintained between the house and the drainfield, and from the drainfield to lot line. 2. The bottom of the drainfield excavation shall be level, plus or minus 1.5", prior to placing sewer rock. 3. The total depth of the drainfield excavation shall be 10.5 ft. in relation to natural ground surface at test hole, prior to placement of the sewer rock. 4. The drainfield gravel shall be covered with typar fabric material. 5. Soil or a combination of soil and extruded board insulation to at depth of 3' or equivalent is to be placed over the Ieachfield. 6. The area over the drainfield is to be finish graded or mounded to prevent ponding of surface water runoff. 7. The septic tank and Ieachfield must not be closer than 100' to any existing private well, 150' to any Class "C" well, or 200 feet to any community well. \\Ercs\DOCS\WPDOCS\2006\06-017drainriicld- spcc.doc Eagle River Engineering Services Christopher R. Wood, RE RECOMMENDED LEACHFIELD DIMENSIONS: TOTAL DEPTH = 10.5' GRAVEL DEPTII = 4' under pipe, 2" over pipe (4.5' total) DRAINFIELD LENGTH = 56' DRAINFIELD WIDTH = 5' SOIL RATING= 0.8 GPD/R= BEDROOM CAPACITY= 4 total SEPTIC TANK = 1250 gallons min. Twenty-four (24) hours notice required for all inspections. \\Ercs\DOCS\WPDOCS\2006\06-017drninfield- spcc.doc EAGLE RIVER ENGINEERING 10421 VFW RD, SUITE 201 EAGLE RIVER, AK. 99577 (907) 694-5195 FAX: (907) 694-3297 SOILS LOG - PERCOLATION TEST PERFORMED FOR: NORMAN CAMPBELL DATE PERFORMED 5/11/2006 LEGAL DESCRIPTION: THUNDERBIRD FALLS LOT 1 TEST HOLE N 2 SLOPE DEPTH r--r---� Ktam WAS GROUND WATER ENCOUNTERED? NO WATER MONITORING DATA DATE IWATER LEVEL 05/11/2006 NONE 06/04/2006 NONE OF ACq i .CHRISTOPHER R. WOOD.' CE -10387 1 �:RO`ESSION N', TOWNSHIP RANGE SECTION T16N. RTW. SEC 36 SITE PLAN NOT TO SCALE A�RIw11 Y1 I 1 Y YI 10% PERC TEST RESULTS FBMOLATONRATE=8 (MIN" FERCHOLEDAMErDW SOILS LOGGED PERCOLATION TEST BY: CHARLES BALZARINI CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 6 / 6 ass FBMOLATONRATE=8 (MIN" FERCHOLEDAMErDW SOILS LOGGED PERCOLATION TEST BY: CHARLES BALZARINI CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 6 / 6 Norman Campbell P.O. Box 576 Chugiak, AK 99567 ' fC 025 "L" STREE f A VCHORAG[, AI_ASI<A 99501 9071 2G4 4111 ('PU)T?GE 40. SULLIVAN, 11A VOR f itCiu;N January 4, 1982 Permit # 810803 y Subject: L1 B1 Thunderbird Falls A permit issued by this department for a well and/or sewer system has expired as of December 31, 1981. Permits are issued on a calendar year basis, as stated on the permit, by authority of Municipal Ordinance. If you have drilled the well, a well log should be sent to this department to document the installation date. If an engineer inspected the installation of the on-site sewer system, please have them send us the as-builts for our files. If there are any further questions, please call this office at 264-4720. Sincerely, 4�% �% 66c �� C� Les N. Buchholz R. . Program Manager Sewer and Water Program Enclosure: Copy of Permit DEPARTMENT o: HEALTH HP'dt' ENVIRONMENTAL kOTECTION 825 'L' • STREET: ANCHORAGE, AK. 99501 264--470 PERMIT NO. r 8I0801 ) AF'PLIC:r-iP'dT hdOf?tgHP•d CAt•1F'E:ELt- PO BX 576 C:HLuGIAF` 88 — 007 LOCATION THUNDERBIRD FALLS LEGAL LIBI THUNDERBIRD FALL'S LOT SIZE 1040000 SQUARE FEET TYPE OF SOIL ABSORPTION SYSTEM IS: TRENCH MAXIMUM NUMBER OF BEDROOM: = _ SOIL RATING KSQ FT/BR)== 172 THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS: 11b A•-- F0" T 4--i _-_` _ �. �"_ �-°� A_n -E... f .. - v = f A °a m N.._ �"" -p•-. F'� c ro THE LENGTH DIMENSION IS THE LENGTH 0N FEET) OF THE TRENCH OR DRAINFIELD. THE DEPTH OF A TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE EXC:AVATION ON FEET). THERE IS NO SET WIDTH FOR TRENCHES. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE AND THE BOTTOM OF THE EXCAVATION (IN FEET). F? E_ Cl E_E 3" F Z E_ E> _" Ems: F'° 0_ g A_: 'T- 6=E Kl F'=__ _..E _-LA-_A ED EN C3 FA f _ I_--. A_A 1A "_° PERMIT APPLICANT HAS THE RES-PONSIALITY TO INFORM THIS DEPARTMENT DURING THE INSTALLATION INSPEC:TIONS OF ANY WELLS ADJACENT TO THIS PROPERTY AND THE NUMBER OF RESIDENCES THAT THE WELL WILL SERVE. ..- _ — _v t-19 A_A r" `e 1 141 W0 w E=o E�- I- I A_A KA :'_'" E' -E F4" E_ F°': E= R-9 U 1 LFZ E_ C-6 BACKFILLING OF ANY SYSTEM WITHOUT FINAL_ INSPECTION AND APPROVAL BY THIS DEPARTMENT WILL BE SUBJECT TO PROS•FCUTIQN. 'f 4,,1t ��_. J1' MINIMUM DISTANCE BETWEEN H WELLFllbri-ANY ON—SITE SEWAGE DISPOSAL SYSTEM IS 100 FEEL- FOR A PRIVATE WELL OR 150 TO :200 FEET FROM A PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL.. MINIMUM DISTANCE FROM A PRIVATE WELL TO A PRIVATE SEWER LINE IS 25 FEET AND TO A COMMUNITY SEWER LINE IS 75 FEET. OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER INSTALLATION. FO- E007? TO I -I- E07 K! 6=' IL FT ES: I, E._-• E= ED E= rl E3 E✓' FT A !L : AL <2 E3 -11 I CERTIFY THAT I: I HM FAMILIAR WITH THE REQUIREMENTS FOR ON—SITE SEWERS AND WELLS AS :_ET FORTH BY THE MUNICIPALITY OF ANCHORAGE. ?' I, WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES. 3: I UNDERSTAND THAT THE ON—SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE RESIDENCE IE• REMODELED TO INCLUDE MORE THAN 3 BEDROOMS. SIGNED10 ---------------------------- APPLICANT NORMAN CAMPBELL ISSUED E;�'� s' t <.°....!Ii r..n-r'c )��. -. a ° V4. 0 Russell Oyster 694-2774 Performed for: O & E ENC,NEERING & DEVELO, HENT CO. Box 90, Davis St., Eagle River, Alaska 99577 694-2774 or 688-2280 SOIL LOG Earl Ellis 688-2280 Tel. No.%`�Q7 r�ZZ,, G-7� c�u.�r��G � K� �-7,Sz� Mailing Address: r Legal Description: Depth (feet) Soil Characteristics C 1 3 4 5— g /am 6 �Cr 7 L, 0 Lacs C -rt svi rYz c:�nt o N✓�•T C> v. 10 A, 7 Ground Water Encountered: Yes No If yes, what depth Proposed Installation: Seepage Pit— Drain Field C—,v-r— t a t—rl— 1 TµTr✓ar0-43eOa� PLOT PLAN PERC. TEST a- = Z l rvf 2/,,s- -z7g.F;i-l%,e Performed byx��L- ("t �� �� - Date: 111Aj�����—