Loading...
HomeMy WebLinkAboutTHUNDERBIRD FALLS LT 3 Tom Fink, Mayor January 10, urdcipaH y Ar chorage Department of Health and Human Services $25 "L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 1991 Mark F. Campbell HC 79 Box 1645 Chugiak, Alaska 99567 Subject: Lot 3 Thunderbird Falls Subdivision Permit #900356, PID #051-411-06 The subject permit, issued by this office for a single family well and/or on-site wastewater system has expired as of December 31, 1990. A new permit must be obtained from this office for a well and/or on-site wastewater system not installed by the expiration date. to be sent to If you have drilled the well, a well log needs this office for documentation of the installation and to close the permit. If a private engineer inspected the installation of the on-site wastewater system, the original as-built inspection report (three-part form) must be sent to this office for review, approval and documentation. All inspection reports must be submitted Within 30 days of construction completion. When applying for a new permit, the fees are: $90.00 for an on-site wastewater permit; $50.00 for a well permit; $140.00 for a combined on-site wastewater and well permit. If you have any questions, please call this office at 343-4744° JW/ljm:200 enc: Copy of Permit ~Kids Are Our Future GAAfJ-HD-I GP/~TER ANCHORAGE AREA BOROI/'~"~ D,.,ARTMEI~T OF ENVIFIONMEI~TAL 0.UALI, r ~ 3500 TUDOR ROAD ANCHORAGE, ALASKA 99507 279-8686 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM LOCATION MAILING ~1" ,~OJ ADDRESS LEGAL DESCRIPTION ~/O/'.~ SEPTIC TANK: DISTANCE FROM WELL LIQUID CAPACITY /~ _GALLONS. MATERIAL 5/'~4&/ INSIDE LENGTH NUMBER OF COMPARTMENTS INSIDE WIDTH LIQUID DEPTH__ SEEPAGE SYSTEM: SEEPAGE PIT: NUMBER OF PITS J OUTSIDEDIAMETER UN,NG MATER,A, * NEAREST LOT LINE OR WIDTH [,~ I~ ~ II DISTANCE FROM WELl TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) .LENGTH /.~/~// DEPTH BUILDING FOUNDATION '~'~'~'~' , 2~:~ Y SQ. FT. TILE DRAIN FIELD: DISTANCE FROM WELL NUMBER OF LINES ABSORPTION AREA , FOUNDATION DISTANCE BETWEEN LINES SQ. FT. LENGTH OF EACH LINE DEPTH: TOP OF TILE TO FINISH GRADE NEAREST LOT LINE 1RENCH WIDTH TOTAL LENGTH , OF LINES IN. TOTAL EFFECTIVE DEPTH OF FILTER MATERIAL BENEATH TILE IN. ABOVE TILE -- WELL: LOT LINE TY,E ,"~t/,~4,//'~////-//'~' ~'? '~'~'-'t'D,STANCE EROM DEPTH , BUILDING FOUNDATION. NEAREST SEPTIC SEEPAGE ., SEWER LiNE , TANK , SYSTEM___ WATER SAMPLE , CESSPOOl , NEAREST OTHER , SOURCES DISTANCES: DIAGRAM OF SYSTEM 1' G.A.A.B. DATE r¢7/ APPROVED GREATER ANCHORAGE AReA BOROUGH D£PARTMENT OF' ENVIRONMENTAL QUALITY 3500 TUDOR ROAD POUCH 6-650 ANCHORAGE, ALASKA 99502 TELePHONe 279-8686 SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT PERMIT NO, MA]LiNG ADDRESS~/~' ~/ ///~e/~/,/' PHONE INSTALLATION OF: SEPTIC TANK / TYPe AND SIZE OF FACILITY TO ~E SERVED SOIL TEST RESULTS SEEPAGE Pit ~' DRAIN FIELD OTHER NOTE: THIS PERMIT 15 NOT VALID WITHOUT SOIL TEST COMPLETION DATE ANTICIPATED MINIMUM DISTANCES, REQUIREMENTS FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIT SEPTIC TANK TO SEEPAGE PIT WALL SEPTIC TANK SEEPAGE PIT TO NEAREST LOT LINE. WELL TO SEPTIC TANK DRAIN FIELD WATER MAIN TO SEPTIC TANK DRAIN FIELD SEPTIC TANKi _, SEEPAGE PIT TO RIVER, LAKE, STREAM. , DRAIN FIELD · DRAIN FIELD SEEPAGE PIT ALSO CONSIDER AREA WELLS. ., SEEPAGE Pit ~ DRAIN FIELD CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION S FEET INTO UND]STURE~eD SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC: TANK AND SEEPAGE Pit FITTED With AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING ~NSTALLATION. DIAGRAM OF SYBTEM ~,~ EA LTH AUTHORITY or LICENSED DESIGNER CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE / CASE # GRE~R ANCHORAGE AREA BOROUGH DEPAR~ ENT OF ENVIRONMENTAL QUAL1 3500 TUDOR ROAD ANCHORAGE, ALASKA 99502 Performed For.~e~m ~m~ ~u~,~ Date Performed Legal Description: Lot Block Sl~b ......... This Form Reports Soils~g ~ Percolation Depth Feet Soil Characteristics Test Was Ground If Yes, At Water Encountered? What Depth? ~/ Reading Date Gross Time Net Time Depth to H20 Net Drop ~te Minute Proposed Insta'l"lation: Seepage Pit Drain Field Depth Of Inlet Depth To Bottom Of Pit ~ Trench Performed By' · /~ ' Data ~ertified By: ~ // -~/~/c'~ Date: