HomeMy WebLinkAboutTUSTAMENA TERRACE LT 8A o'T'
Torn Fink,
Mayor
January 8,
Municipality Anchorage
Department of Health and Human Services
825 "L' Street
P.O. Box 196650 Anchorage, Alaska 99519-6650
1990
Tom Price
Box 231
Unalaska,
Alaska 99615
Subject: Lot 8A Tustamena Subdivision
Permit #890164, PID #017-381-14
The subject permit, issued by this office for a single family
well and/or on-site wastewater system has expired as of December
31, 1989.
Permits are issued on a calendar year basis by authority of the
Municipal Code of Regulations. A new permit must be obtained
from this office for an well and/or on-site wastewater system
not installed by the expiration date.
If you have drilled the well, a well log needs to be sent to
this office for documentation of the installation and to close
the permit.
If a private engineer inspected the installation of the on-site
wastewater system, the original as-built inspection report
(three-part form) must be sent to this office for review,
approval and documentation.
When applying for a new permit, the fees are: $90.00 for an
on-site wastewater permit; $50.00 for a well permit; $140.00 for
a combined on-site wastewater and well permit.
If you have any questions, please call this office at 343-4744.
Sincerely,
John Smith, P.E.
Program Manager
On-site Services
JW/ljm:200
enc: Copy of Permit
"Kids Are Our Future"
M U Iq
De~pai"'Lmer'rL oF Nealth & Human Serv.ic:e:,s
825 L. Str'eet~ Anther'age, A].~ska 995C)1
:'1" E S E W E R & S E F::' '1' I C "1' A N K P E R M
E:ngioeer Designed
I T
{]Wl]ep Name:
TOM PRICE
Bt]X :2:31
UNAL.ASI<A,
AK 996 15
Day I:::'h en e ~
5i!:/1- 16 15
Parcel Id: 017-:$81-'14
Lot L,.ega!: Subdivis:Lon~ 'TUS]"AMENA L. ot.: 8A Block:
Settle, n: 2',7 TownshJ. p: 12N Range: 3W
t_e~. ~:i. ze 50589 (sq. ~t.~ or ac:pe~)
Flax )~edl'~ooms: 'l"]]J.~ PepmJ. t] 3 Total C~pac::ity:
0
SEF']'!C TANK: Minimum ret. al sep'Lic: 'Lanl.::
tank must have at ].east 2 compartments.
Feet i-(.~,qLlire~ Jl"lsutat:[on over' 'Lank (s) ,,
capae:i'Ly: 1:,()00 gallc)n~s. Each septic:
Depth 'Lo top o~' septic tank(s) < 4.0
'I"IIIS SYS'TEM T[) BE INSTAL.L.ED IN ACC[]IRDANCE WI:TH ]"HE AF'PROVEiD
ENGINIS:!ER'S DESIE.tN,, DHHS MLIST BE NOT]:F'IIZD PRIOR 'i"0 ALL INSF'ECT"--
IONS. T'II]:S PERMI]' IS FOR A 3 BE:DROOM SINGL.E F'AMILY RESIDENCE
ONI....Y, AND EXPIRES ON 12/3:1./8~,, INS]"ALJ_ATtON OF:' A L. IFT STA]"I[IIq
R!ZQUIRES ]'HE AF:'F:'ROPI:C[ATE EL~ECTR]:CAL. INSF:'E[71"ION.
I CERTIF:'Y THAT:
i,, I am Familiar wit. h 'Lhe recluir'ements for' on-s:i, te !sew(~l-S and wells as set
~'ortll by the Munic:i. pality oF Anchopage (MOA) and thee State oF Alaska.
~. I wi].1 :i. nstal], the system in accordance ~JJ.'l.h all MOA ce)des and pegu]a'L:i,c)ns,
and in c:oml:]].J, anc8 b~)J.'Lh the deeign triter'ia oF this permit.
· 3. I will. adher, e to a]l IdOA and Fi'Late oF Alaska requ:[remen'Ls {or' the set back
distances ~Pom any existing weiI, wastewatep disposal, system of public
sewecage system on 'Lhis (::)r any ad.jacen'L of nearby lo'L.
I under'stand that this permit is valid f'or a maximum oF :~ bedr'oc)ms. I
a].sio ui"ider's'Larid that the c:apac:ity (:)(' tf~e total syE4t.~em :i.!~ :3 bedrooms and
a.l]y enJ. apgemerit wi],], i"~RL.(FLI"(~ an addi'Liona], pePmit.,,
Eli oFlec:t: . ' ""'"", ...................................................
~(Ownei' ) 'T'~:~]:~E / ~
Issued ~ ............ D(YFE~
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & HUMAN SERVICES
On-Site Services Transmittal Sheet
The attached paperwork has been reviewed and is being returned
for the following reason(s):
~/wells, curtain drains
not shown.'
Discrepancy in legal description.
Incomplete; needs
Signature missing on
and streams within 200
Area soil/well information needed.
· ~ ...... Other ~/.~>,,-,~,~ ~,~ ~/'~'/~>'~'~. ,'~;"~ ?~'~,~
Please supply the necessary information and re-submit your
request. Your cooperation is appreciated.
Date /~/L4~//,{~ ¢/~ Reviewer
/aen203-~
N
I hereby certify tbat I have surv~&d ~Ae following doscf-ibe'd
property: Zo7~ ~ 7--o ~%~ .~ 7~ .~.-~ c ~
[~ /~-;~ ~ ~ ' Rmcordt~g Precinct, Alaska, end that the
improvements situated thereon are wikhin the property lines and
do not overlap or encroach on the property lying adJacen~ there-
to, that no ~mproven~nts Ca property lying adjacent thereto
encroach on the .premises in question' end that' there are no ,
roadways, transmission lines or' other visible easenents om
said property except as indicated hereon. ':
Dated 9.t'
~ - , ~ ~..- ~ ~. '
Price En~ineerin~ .,
Depf, rt. ment o~ Health ;md Environmental ~rotection DEP/, OF HEALTH &
-' " ENVIRONMENTAL PROTECT ON ':
2516 1':. Tudor Road ' :, :'
Anchorage, alaska 99507 O~0 2 1977 ;
276-222i -i
eerformud for ~7~z~ ,~?~' .......................... ;...y"";-"-r?"fh,J..../-/~z-_~,/'Z7'_ il
This form reports: Soils log ......... ~_ ......... vercolat~on ~est ~ ':.: ,-u~
Depth
Feet
I -
2-
3-
q-
7-
12 -
13 -
Was ground water encountered?
_.j~_~_ ...... If yus, at what de;~th? .......
Reading
.... Lo_fL(.,_'_
L.___m. :_~_& .
Date (]ross Time Her Time J Depth to Water Net Urop
.
'--/~ .: ~--- "b.'"~ ~z '_ ~ '_-:~.~2-:
.... It ~t-.- ..... :-,- -~, - .... .-~ .' - -; .'~ .~./~,- ......
Percolation race .~_g.. ~_/.~{z,~,_.~ ....... . -. ~ ,
installatiun ~e paqe P!L ~ ~)r'a]ll,llc'id' ~_.. _ ........
r! . _./ zo__ ~.~.~. t_. /_>~.,
?erf0rmed [ ~i-~ _ ~ ~.._ ............................
t:7.~- 0,10 (O/t 4 ) ~{::. /_~d~,,~-~ ~5/~9. ?~/o~''-~' ~
.I
z tTC /-/ lTD.
........... -- 47o. 4,.~ ....... .~ F'T. R.O. lZJ.
- l-/.Zb'Ol~ .....
0 \ \
O'
-- ~AUNICJPALITY OF ANChOr;AG2
~f ~ 2516 ]']. Tudoz' l{oad ~ ~ ~NVRONM~NTA~ PROT~CTIQN
1977
Anchorage, Alaska 99507
~ [IV
REC
H()ll,H IX)L; - I~}':R()I &lION TEST ~
Performed for_...~_, ff~4~ .......................... ~ ............
This form report~: Soils 1o0 ~ Percolation Lest ~
Depth
:Feet
7-
B-
9-
10-
11
12-
13-
14- : ,:
Was ground walzcr encountered?
___z'/lt/6)___ i_ If yes, at whaL depth? ......................
Reading.__ lO;mo .... ~~ss Time ._ " Net Tiros _ .?~tlLt~?m>,' Net ~ur°[" .. ":
.... l ...... [ ........................ H~ ....1 ....... ~ ....._].~.~ ..... ~..Z~/,~.
S.__~.~_-~j. ..... LF~._. Z._~ .... ~ ........ ~s~ ..... '_L :._ _~_..~'~ .... _~.~__
IM>U, of Inlet . oept'rF~.¥i,¥((ob i~-r-pit or.trench .... ]~]"~
825 "l "S'I RE E"['
ANCHQ.qAGE, Al ASKA 99,501
(907) 264-41~ I
December 31, 1979
Tom Price
Bo:< 81
Anchorage, Alaska 99501
Permit ~ 790035
Subject: Lot 8-A Tustamena Subdivision
A permit issued by this department for well and/or sewer
system has expired.
Permits are issued on a calendar year basis, as stated on
the permit, by authority of Municipal ordinance.
If you have drilled the well, a well log should be sent
to this department to document the installation date.
If an engineer has inspected the installation of the
on-site sewer system, please have them send us the as-builts
for our files.
If there are any further questions, please contact this
office at 264-4720.
Sincerely,
Les N. ~uchholz, R.S. .z--~
Senior ~nvironmenta! Speci~-?ist
LNB/ljw
enc: Copy of ~ '~
PERMIT NO. (
DEPFIRTMENT OF HERLTH RN[:' ENVIRONMENTRL PROTECTION
825 "L" STREET., RNCHORFIGE., RFC
264-4'~20
?~'¢00~:5 }
RPPLICRNT
LOC:RTION
L. EGRL
TOM PRICE
LT. 8-R TUSTRMENR
FINCH
LOT SIZE
276-524~
50000 SQUBRE FEET
MINIMUM DISTRNCE BETWEEN R WELL FIND RN"r' ON-SITE SEWFIGE DISPOSRL S"r'STEM IS
2L00 FEET FOR 8 PRI'v'FITE WELL.; OR
J. 50 TO 2E~0 FEET FROM B PUBLIC WELL DEPENDING UPON THE -F"r'PE OF PUBLIC WELL.
WEL. L LOGS FIRE REQUIRED BND MUST 8E RETURNED TO THE DEPRRTMENT WITHIN ]:0 DFI"r'S
OF THE WELL COMPLETION.
OTHER REL-]LIIREMENTS MB'¢ RPF'L'¢. SPECIFICRTIONS RND CONSTRUCTION DIFIGRRMS RRE
R'v'BILRBLE TO INSURE PROPER INSTRLLRTION.
I CERTIF"r' THRT
:L: I Rf'l FRMILIRR WITH THE REQUIREMENTS FOR ON-SITE SEWERS RND WELLS FqS SET
FORTH BY THE ML~ICIPRLITY OF RNCHORFIGE.
2: I WILL INSTRLL THE SYSTEM IN RCCORDRNCE WITH 'FHE CODES.
b I uNED: _~~ ................
;/]% 2
DEPT. OF I ALTH ~, i . :
ENV RONMEN ,; , IECTION
R:E:CEI ViD