Loading...
HomeMy WebLinkAboutUS SURVEY 3202 LT 2 T10N R1W SEC 10 Rick Mystrom, Mayor Mtmicipality of Anchorage Department of Health and Human Services 825 "L" Street P.O. Box 195650 Anchorage, Alaska 99519-6650 343-4744 March 22, 1995 Mr. Timothy J. & Cecilia L. Miller HC 52 Box 8517 Bird Creek, AK 99540 Subject: Lot #2, US Survey 3202 Permit #SW940052, Parcel ID #090-022-24 Dear Timothy & Cecilia Miller: The subject permit, issued March 18, 1994 by this office for a single family well aad/or oa-site wastewater system, has expired as of March 18, 1995. A new permit must be obtained from this office for a well and/or on-site wastewater system NOT installed by the expiration date. If the well was drilled, a well log must be sent to this office for documentation of tile installation and to close the permit. If tile on-site wastewater system has been completed and a licensed Professional Engineer has inspected the installation of the on-site wastewater system, the original as-built inspection report must be sent to this office for review, approval and doculnentation. All inspection reports must be submitted within 30 days of construction completioa. When applying for a new permit, the fees are: $320.00 for an on-site wastewater perlnit; $120.00 for a well permit and $440.00 for a combined on-site wastewater and well permit. If you have any questions, please call this office at 343-4744. Sincerely, Program Manager On-Site Services JC/kb cc: James A. Smith, P.E. MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 PAGE 1 OF ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW940052 DESIGN ENGINEER:BUZDOR ENGINEERING OWNER NAME:MILLER TIMOTHY J & CELIA L OWNER ADDRESS:HC 52 BOX 8517 ANCHORAGE, AK 99540 DATE ISSUED: 3/18/94 EXPIRATION DATE: 3/18/95 PARCEL ID:09002224 LEGAL DESCRIPTION: US SURVEY 3202 LT 2 LOT SIZE: 108900 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 OR 343-4681 AFTER BUSINESS HOURS 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: THE TOTAL DEPTH~ THE DRAINFI/~LD MAY NOT EXCEED RECEIVED BY: ~Z~4~Z~ ~/~,~ 6.0 FEET. DATE: DATE: EBA Engineering Inc. Geotechnical and Materials Engineers March 10, 1994 0941 0287 Municipality of Anchorage Department of Health and Human Services P.O. Box 196650 Anchorage, AK 99519 On-Site Sewer Application Gentlemen: RECEIVED MAR 1 1 1994 Municipality of Anchorage Dept. Health & Human Sen/ices U.S. Survey 3202, Lot 2, T10N RIW S10 The attached paperwork presents EBA Engineering's on-site sewer design for the above referenced property. Design of the absorption field follows requirements specified in the Anchorage Municipal Code Chapter 15.65. A five foot wide shallow trench with a two foot effective depth has been specified. The minimum trench length is 55 feet and the maximum depth of the trench is six feet below the original ground surface. Reserve area for the lot is approximately 100,000 square feet. Slope on the tract is 30 to 35 percent on the south side of the property and 0 to 5 percent on the north side of the property. Slope in the immediate vicinity of the proposed drainfield site runs between 0 to 5 percent. Separation distances from the proposed system to all adjacent systems exceed 200 feet and impact on adjacent systems and property appears negligible. There is no surface water in the immediate vicinity of the drain field. The subsurface soils are primarily silty sands with gravel (SM) with a percolation rate of approximately 20 min/inch. Groundwater was not encountered in the drainfield area. The system installation will follow requirements specified in the Anchorage Municipal Code Chapter 15.65, and will be in accordance with On-Site Wastewater Disposal System Permit provisions. The following modifications have been made to EBA's initial on-site sewer design: 1. The calculation error has been corrected. Two 5' by 55' shallow trenches have been substituted for the original design. 2. Cleanout locations have been clearly delineated. 3. The total depth of the proposed bed has been illustrated. 907-East Dowling Road, Suite 27, Anchorage, Alaska 99518 · Telephone (907) 561-4085 · FAX (907) 561-7071 · 0941 0287 Page 2 4. The reserve replacement trench site has been moved an adequate distance from the 30 to 35% slope on the south side of the property. If you have any questions or require further clarification, please feel free to contact me at your convenience. Sincerely, EBA Engineering Inc. Project Engineer Attachments: EBA Proposed Septic Design Plan View (original) On-Site Services Transmittal Sheet (original) Soils Log-Percolation Test Form - Test Hole No. 1 Soils Log-Percolation Test Form - Test Hole No. 2 EBA On-Site Design Sheet RESIDENTIAL ON-SITE DESIGN SHEET SINGLE FAMILY DWELLING MUNICIPALITY OF ANCHORAGE GUIDELINES EBA Engineering Inc. Phone: (907) 561-4085 907 East Dowlin~ Road, Suite 27, Anchorage, Alaska 99518 Fax: (907) 581-7071 DEEPTRENCH PROJECT NO: 0941 0287 CLIENT: MR. TIM MILLER SITE LOCATION: BIRD CREEK, ALASKA LEGAL DESCRIPTION: LOT 2, U.S. SURVEY 3202 NUMBER OF BEDROOMS: 3 MINIMUM SEPTIC TANK SIZE: 1000 GAL PERCOLATION RATE: 20 MIN/IN DEPTH TO GROUNDWATER: 10 FEET PLUS BACKFILL TO ORIG. GRD. SURFACE: 3 FT WASTEWATER APPLICATION RATE: 0.6 GPD/SQ FT WATER USE PER BEDROOM: 150 GPD ABSORPTION AREA REQUIREMENT: 750 SQ FT SHALLOW TRENCH OPTIONS: TWO INCHES STYROFOAM INSULATION REQUIRED OVER LINE WITH THREE FEET OF BACKF]LL DEEP TRENCH EFFECTIVE REQUIRED TRENCH DEPTH (FT) LENGTH (FT} 4 4.5 5 5.5 6 7 SHAI_LOW TRENCH TRENCH REQUIRED TRENCH LENGTH (FT) * To Close To Groundwater Or Not Considered COMMENTS - DESIGN CRITERIA SEPARATION DISTANCES FROM PROPOSED SYSTEM Water Well - 100It + Propedy Lines end Buildings - 10 ft + Slopes Greater Than 25% - 25 ft + System piping and tank must be Installed following 199t Uniform Plumbing Code requirements. Minimum two comparlment septic tank size is 1,000 gallon capacity. An additional 250 gallon capacity is recomended if a disposal or garbage grinder is used in the residence. Install filter fabric over Ihs sewer rock, including areas covered wilh solid Insulation. Trench should follow site contour. ABSORPTION BED DISPOSAL FIELD DESIGN ~ 3 BEDROOM; 0.6 GPD PER SF APPLICATION RATE; 15' BY 50' BED (750 SF) II I~, I ) I I I I \ \ I 1 I t DRIVEWAY I I / \ / \ / \ \ I MONITOR TUBES /~\ '%, AT'~kCORNERS ~\ OF~BSOR~TION FIELD k SOIL ABSORBTION FIELD CROSS-SECTION MONITOR TLIBES 4' MIN COVER ~ 1' FiL~rER FABRICL~ SEWER ROCK NOTTOSCALE ~ERFORATED DISTRIBUTION PIPES Miller Property, Bird Creek, Alaska Plan View - Proposed On-Site Septic System Design Project No. 0941 0287 1/31/94 EBA Engineering Inc. 907 East Dowling Road, Suite 27, Anchorage, Alaska 99567 Phone: (907) 561-4085 Fax: (907) 561-7071 \ SCALE: 1 Inch = 40 Feet 1 2 3 4 PERFORMED FOR: LEGAL DESCRIPTION: DEPTH 7 8 9' 10 11 12 13- 14 15 16 17 18 19- 2O Municipality of Anchorage 825 L Street, Anchorag , Alaska 99502-0650 so~s ~o~ - p~.co~o. T~S~ DATE Township, Range, Section: SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? S L IF YES, AT WHAT ~'~O "~ pO DEPTH? " Depth In Water Alter Monitoring? tale:. Gross Net Depth to Net Reading Date Time Time Water DroP / ~,/~/,~. :.,It o '~' 0 % i:$5. g ~ ' 0 ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES 72-008 IRev. 4/85) 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19- 20- PERFORMED FOR: LEGAL DESCRIPTION: 3 ' ! 49~h ~'~ ~ I Municipalily of Anchorage ....................... ~...~,..~ ~ 825 "L" Street, Anchorage. Alaska 99502-0650 , ~ ~ JQHN A.~U~O~ ~ ~ J SOILS LOG -- PERCOLATION TEST [,~;~:.,._'CE- ~2 ...(~ I ~. ~.,. .... ~ ~ I · ~.'.~D ~....,....¥....~ ~ DATE PERFORMED: -%~ Y ~ ~ Township. Range. Section: T J~ ~l ~ ~1~ I~ WASGROUNDWATER ENCOUNTERED? SLOPE SITE PLAN IF YES, AT WHAT DEPTH? Monitoring? 0 Gross Net Depth to Net Reading Date Time Time Water Drop ' ~'.~ ~ ~1' o%~ PERCOLATION RATE ~'~ (mlnutesnnch) PERC HOLE DIAMETER -- TEST RUN BETWEEN ~ FT AND ~ FT COMMENTS PERFORMED BY: ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT OI~.~[S DATE. 72-008 (Rev. 4/85) CERTIFY THAT/THI~ TEST WAS PERFORMED DATE: SHALLOW TRENCH ABSORPTION FIELD DESIGN 3 BEDROOM; 0.6 GPD PER SQ. FT. APPLICATION RATE; 750 SQ. FT. MIN. ABSORPTION AREA TRENCH DIM.: 5 FT. BY 110 LINEAL FT~B"~ F~. E~=FECTIVE DEPTH I \ +10' ~/ CLEANObrrs \+~, I I +~'1 MONITOR TUBES i' ' \ \+2' ILOCATION DRIVEWAY I / / / / \ \ ! i~ RESERVE REPLACEMENT TRENCH SITE \i ' x \ × ,-..- \ -4, \ -2' \ 0' 30 F~T TEST HOLE ~DIUS 5 ~. BY 55 ~. SHALLOW TRENCHES SCALE: 1 INCH = 40 FEET ~ SPECIFIC CR~ERIA: 10 ~. MIN. SEPA~TION BE~EEN: TRENCHES SEP~CTANK AND TRENCES SEPTIC T~K ~D HOUSE SEPTIC SYSTEM AND PROPER~ LINES 25 ~. SEPA~TION BE~EEN TRENCHES AND ABRUPT G~DE CHANGE (SLOPE OVER 25%) 100 ~. MIN. SEPA~TION BE~EEN WELL AND NOT TO SCALE~ Lot 2, U.S. Survey 3202, T1 ON R1W S10, Bird Creek, Alaska Plan View - Proposed On-Site Septic System Design Project No. 0941 0287 3/10/94 EBA Engineering Inc. 907 East Dowling Road, Suite 27, Anchorage, Alaska 99567 Phone: (907) 561-4085 Fax: (907) 561-7071