HomeMy WebLinkAboutUS SURVEY 3202 LT 5 T10N R1W SEC 102 � d ,,.•1 � r2 :3 •a< rr,�.:a:. �.�. �s'iw}5.� ` ,xc�= �,s�v`�;`� ��.€,,,,.s .�w�...�Z:: s���k:'= Municipality of Anchorage On -Site Water and Wastewater Program • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP171232 PID Number: 090-022-21 Dwelling: ❑■ Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑ New ❑■ Upgrade Name: Gary Mohar ABSORPTION FIELD ❑ Deep Trench *Shallow Trench ❑ Bed ❑ Mound Address 923 Powerline Rd. Bird Creek, AK 99540 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 850-417-1453 3 2.0 GPD/SF +1.5 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade +2.0 Ft. Gravel depth beneath pipe 0.5 Ft. Subdivision Block Lot US Survey 3202 5 Fill added above original grade 5.5 Ft. Gravel length 45.0 Ft. Township Range Section 10N 1W 10 Gravel width 5.0 Ft. Beds: Number of Lines 1 Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 225 Ftz Ft. Well >100' >100' N/A N/A >25' TANK ❑ Septic X S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank/Orenco Capacity 11250 Gal. Surface Water >100' >100' N/A N/A Material Steel Number of compartments 2 Lot Line >5' 10' N/A N/A NA Foundation >5' >10' N/A N/A LIFT STATION Manufacturer Anchorage Tank/Orenco Capacity 1250 Gal. Curtain Drain None Noted Remarks *CAT II system installed Pump on level at 48 in. Pump off level at 42 in. High water alarm at 52 in. Pump make and model Electrical Inspections performed by Orenco/PF2005 Capstone Electric PIPE MATERIAL House to tank D3034 Tank to drainfield D 1785 Installer Wilco Construction Drainfield D3034 CO/MT Inspector C. Johansen, J. Millette BENCH MARK (Assumed elevation) 100 ft Inspeectiontes: 15f 11/13/17 11/14/17 Location and description 2nd Bottom of 2nd from south lateral beam on SE wall 3,d 4th COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp Conditional Approval: Date OF A4 �"1�fi1� p' ••"• t f 49 7H k...... ..: .......... Eden Schiller / �� �c�� ApprovedCa-kA Date 1 • �`4� •.• CE 12592.0 Oiw AW Jr/7 DPROfE5S10� Inspection Report_9-1-12.doc US SURVEY 3202 LOT 5 T1 ON R1 W SEC 10 PERMIT # OSP171232 / 50' BLM EASEMENT 11� I hed I I Existing Well II III I Shed 1 1 Two O Bedroom FCO 1 Home \ Shed Shed JGarage— 1\ d� MT2 C0 M H3 2 \ TH D I Shed D K EXISTING SEPTIC TANK WAS M ABANDONED IN ACCORDANCE WITH MUNICIPAL CODE.�� I I \ 50.00 H 50' BLM EASEMENT ptl . .... ... ........... Benjamin 6' ME 32592 •'� ll►:�PROFES510NP�'� A B C FCO 16.2 24.2 SV1 23.6 50.3 SV2 52.2 25.7 MH1 52.3 26.3 MT1 59.1 36.6 C01 60.6 38.7 MH2 53.6 35.1 MI -13 52.0 34.7 CO2 50.1 34.4 MT2 37.8 41.8 CO3 39.6 43.2 0 50 100 FEET 1.1=50' PID # 090-022-21 II I — 1500,GAL STEEL SEPTIC TANK 36" PUMP VAULT W/ AEROCELL PUMP AND t 2 FLOATS 'ot 45' LONG x 5'IWIDE x 0.5' EFFECTIVE DEPTH ABSORPTION TRENCH 650 GPD AER OCELL UNIT I I ALTERNATE SITE LEGEND CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE US SURVEY 3202 LOT 5 T1 ON R1 W SEC 10 PERMIT # OSP171232 PID # 090-022-21 01�— INSULATION �-p _---98.2 FINISH GRADE jj jj 92.7 ORIGINAL GRADE MOA APPROVED DRAINAGE SAND 94.7 94.7 94.2 - N 45 ` 94.2 raj TH *� . • ' Benjami chiller .. ' . WE 22692 l 111�� /'ROFESSI�NP�'~ 91.2 GROUNDWATER 8/16/17 81.2 EXPOSED SURFACES OF MOUND HAVE BEEN TOPSOILED AND SEEDED. PROFILE AS -BUILT (NO SCALE) 3 ,1 May 3, 2018 Municipality of Anchorage Development Services Dept- On -Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: US Survey 3202 Lot 5 — 932 Powerline Road Alternate On -Site Disposal Method Dear On -Site Services Engineer: The owner of the above lot has installed a new advanced septic system to replace one that had failed. The design specified a Category III septic system, a Quanics system with a Jandy valve attachment. However, the contractor installed a Quanics system without a Jandy valve, making this a Category II system. We would like to request approval for this system to operate without re - sizing the drain field or retrofitting the system. In a typical (unmounded) bed installation, the advanced treatment system would discharge to the bed set directly on in-situ soils. The bottom of the bed would need to have a minimum 2' separation to groundwater. A Category II system is specified as having a lower application rate than a Category III system because the effluent does not receive quite the same level of treatment, and therefore will plug up the soils quicker, causing the bed to fail. In the system installed on Powerline Road, there is 2.5' of filter sand that makes up the vertical separation to groundwater. This filter sand changes the system significantly, acting as further treatment before the effluent reaches the receiving soils and the groundwater below. The effluent that filters through to the bottom is effectively Category III effluent. This analysis is supported by the EPA's "Decentralized Systems Technology Fact Sheet" as well as regulations codified for various states. These organizations consider the system to be sized based on the two application rates- that of the filter sand for the initial size of the system and the permeability of the basal soils for the size of the bottom of the bed. This method of analysis acknowledges the use of the sand layer as the initial receiving soils instead of simply a buffer layer. Based on this accepted methodology, the initial layer of receiving sand would qualify for an application rate of 4 GPS/SF for Category II effluent, and is significantly oversized for the system installed on this property. By the time it reaches the slower silty soils underneath, it has received significant filtration, and the use of the Category III application rate of 2 GPD/SF should be acceptable. We are confident that the system as installed meets the intent of the application rates, and increasing the size of the absorption trench, or retrofitting the system to convert it to a Category III system, will have no practical change to the effluent quality. Sincerely, Benjamin Schiller, PE •1;BenjamiMSchiller • •: �'F•• C 1 592 .• �`��i 1hl_PwoFEs INP DEPTH (feet) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 ELMORE ROAD ANCHORAGE, AK 99519-6650 SOILS LOG AND PERCOLATION TEST LEGAL DESCRIPTION: US SURVEY 3202, LOT 5 PERFORMEDFOR: ANDERSON ENGINEERING DATE: 8-3-2017 PROJECT No.: PARCEL ID#: 090-022-21 TECHNICIAN: TEST HOLE 1 SANDY SILT ML BLUE CLAY `SCHILLER / MILLETTE SLOPE SITE PLAN SEE SITE PLAN y WAS GROUND WATER ENCOUNTERED? 1 '4 v READING IF YES @ WHAT DEPTH'S - L DEPTH To WATER (INCHES) DEPTH OF WATER AFTER MONITORING: 1.5' 0 TEST HOLE PRESOAKED PRIOR TO TESTING: DATE OF MONITORING: 8 /16 /17 P 9:36 S/�,S O. S t E DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH To WATER (INCHES) NET DROP (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 8/3 1 9:36 0" 2 10:06 30 0.75" 0.75" 3 10:07 0" 4 10:37 30 0.75" 0.75" 5 10:38 0" 6 1 11:08 30 1 0.75"1 0.75" PERCOLATION RATE: 40 (MIN/INCH) PERC. HOLE DIA. 6" (INCHES) TEST RUN BETWEEN: 1.5 FT. and 2.5 FT. COMMENTS: Test Hole Presoaked Prior to Percolation Test. Silt Layer at 8' is Impervious. >' 'qui 0- rn®®=�A�� ®mto V c 00 01 wQ-vrq3: �rn C) U,j br i M,?- m ON M rqu d>A-q�� ;u M I -S Er, x � —a (n UK m C �0 F)rnrnx ;u rn Fn z e --4 0 q tr^ � 9 I-V rn � w m00 'r P� a777 W w2 � ®� X° cu 0 Cr ,,f t C lK Im 9 All ^ � -tp � cr J- I o H,cIPAtITy MUNICIPALITY OF ANCHORAGE r� • On-Site Water&Wastewater Program S<; .a„�, PO Box 196650 4700 Elmore Road V �. Anchorage,Alaska 99519-6650 Phone: (907)343-7904 Fax: (907)343-7997 y ' �' http://www.muni.org/onsite 1 epartment 4,yckoRp°. On-Site Wastewater Disposal System Permit Permit Number: OSP171232 Effective Date: 9/7/2017 Work Type: Septic Upgrade Expiration Date: 9/7/2018 Tax Code Number: 09002221000 Site Legal Address: US SURVEY 3202 LT 5 T1 ON R1W SEC 10 G:4760 Site Mailing Address: 297 AURIGA LN, Indian Owner: MOHAR GARY Lot Size in Sq Ft: 108900 Design Engineer: FORGE ENGINEERING Total Bedrooms: 3 This permit is for the construction of: 0 Disposal Field 0 Septic Tank ❑ Holding Tank El Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: Provide signed and notarized AWWTS maintenance agreement with inspection report/record drawings. Received By: f i'( 1-14//e/i, /ii i Date: q 7 Issued By: // Date: qAir& Municipalli y of Anchorage• P.O. Box 196650 • 4700 Elmore Road Anchorage, Alaska 99519-6650 • (907) 343-7904 • Fax (907) 343-7997 http://www.muni.org/Onsite Development Services Division On-Site Water and Wastewater Program **** VARIANCE/WAIVER REVIEW **** Waiver#: OSV171102 COSA#: Permit#: OSP171232 PID#: 090-022-21 Legal Description: US Survey 3202 Lot 5 Engineer: Forge Engineering Applicant: Gary Mohar Your request for a waiver of the required 4 feet vertical separation from the bottom of the absorption field to groundwater has been approved. The approved separation distance is 2.0 feet. In addition, your request for a waiver to provide Engineered Receiving Soil (ERS) in the absence of 2 feet of native unsaturated accepting soil has been approved. See engineer's letter for waiver request and justifications. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-site wastewater disposal system will require all code requirements be met or another approval from this department. The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. n Notarized letter(s) of nonobjection have been received from the owner(s) of the affected adjacent property. ® Adjacent properties are not affected by this waiver. Waiver is Granted: X Waiver is not Granted: Date: 4/1(0201 Approved by: kiltetk (GNLe'v Name of Reviewer **** VARIAN C EIWAIVE R REVIEW **** MUNICIPALITY OF ANCHORAGE ,7" :. ..)1 Community Development Department Phone: 907-343-7904 Development Services Division Fax: 9 -34 -7997 On-Site Water & Wastewater Program 6 1 8 9 10 77 ON-SITE SEWERNVELL PERMIT APPLICATION ti1. AUG 1b2017 t Parcel I.D. 090-022-21 1- Property owner(s) Gary Mohar Day phone �``cv Mailing address 923 Powerline Road, Bird Creek, AK 99540 69 L y Site address 923 Powerline Rd Legal description (Sub'd., Block & Lot) US Survey 3202, Lot 5 Legal description (Township, Range & Section) T1ON R1W SEC 10 Lot Size 108,900 Sq. Ft. Number of Bedrooms litre e (3.) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (®all that apply) Absorption Field CI Initial ❑ Single Family (SF) El (w/wo ADU) Septic Tank 0 Upgrade E Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE I WAIVER REQUEST FOR: Sefono 'troeN -11) ry-ou.‘c# k,ao. kr i ER,S Distance: a (* N \ I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Sig ature of operty owner or authorized agent) Permit/Rush Fees: 6105' Waiver Fees: 41 2 1 5 Date of Payment: %1 t r/t Date of Payment: 9/ri/I I Receipt Number: QQa1(pr Receipt Number: 0(15 70 C Permit No. 05 P l902. Waiver No. O SV fl 1 I 0 c2 Permit App_9-1-12.doc FORGE ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) September 6, 2017 Municipality of Anchorage Development Services Dept- On-Site Water& Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: US Survey 3202, L5 Waiver for vertical separation to water and engineered receiving soils Dear On-Site Services Engineer: The owner of the above lot is replacing his failed septic system with a new Category III system and absorption trench. Due to the high groundwater, a mounded system will be necessary to achieve the required separation distance from groundwater. The test hole data shows organics for the top 1', sandy silt under that down to 8' and blue clay beneath that. The groundwater has been measured at 1.5', right near the top of the in-situ soils. The seasonal high groundwater level is estimated to be right at the bottom of the organic layer. Current code requires 2' of in-situ receiving soils above the seasonal high groundwater levels. We are asking for a waiver to allow 2.5' of engineered fill (a minimum of 2' of filter sand, and the rest can be sand or Type II soils) to be used in this case. The peat and organics will be removed from under the trench, and the needed amount of fill placed, with the top 2' specified as sand. The filter rock will be placed on top of that fill. There are no adverse consequences to this proposal. The classified fill is better quality than the in-situ soils, and will provide for greater separation to groundwater. In addition, we are asking for a waiver to allow 2.0' separation to groundwater in this case. Since this is a Category III septic system, it processes the effluent significantly more than a typical septic tank. The difference in effluent quality is enough that reducing the separation by 2' to groundwater will not cause any threat to health, either in this property or in neighboring properties. + ..,:0� 1d4%, Thank you for considering this request. . 44 ��.;1.•°• AtVS_ 7" , 0 Sincerely, s • ' trm.' 1 & tikes • � o de c Benjamin Schiller, P.E. `#0��•�r�,5 �"�� ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) August 26, 2017 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 Elmore Road Anchorage, AK 99519-6650 Subject: U.S. Survey 3202, Lot 5 Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The septic system on the subject lot has failed and must be replaced prior to the issuance of a COSA for the property. The existing system is undocumented and the exact location and configuration is unknown. We are therefore requesting a permit be issued for the upgrade of the septic system to accommodate the two-bedroom home on the lot. The new septic system however is designed for a three-bedroom home. The attached Site Plan and backup documentation identify the approximate location of the existing system and the proposed location for the new septic system along with the existing well. The existing septic tank and absorption system will be decommissioned in accordance with Municipal Code. No conflicts exist between the proposed septic system and the wells on this or adjacent lots. Drainage arrows are shown indicating the current drainage patterns. Drainage patterns will not change with construction. The test hole recently placed on the lot indicated Sandy Silt (ML) in the absorption zone of the trench. The percolation rate was determined to be 40 minutes per inch. The soil material changed to impervious silt at 8' below the surface. No groundwater was encountered during the placement of the test hole but was recently noted at 1 .5' below the surface. We are therefore requesting a waiver allowing the design to be reviewed under the new Wastewater Code which allows the use of Engineered Receiving Soils and a separation distance of 2' to groundwater with a Category III septic system. We have designed the new absorption system with an application rate of 2 gallons per day per square foot. We are proposing to place a new 1,500 gallon steel septic tank and a Quanics Aerocell System along with a 45' long by 5' wide absorption trench with 0.5' effective depth. The total depth of the system will be 1.5' above the surface with the US Survey 3202, Lot 5 August 26, 2017 Page Two distribution line at 2' above the existing surface. This will provide a 3.5' separation distance from the current groundwater level. The groundwater may be found closer to the surface during high runoff periods, but it is unlikely to encroach into the organic layer. The organic layer will be removed and replaced with MOA approved sand. The ground surface on the lot in the area of the new trench is virtually flat with minor sloping to the south. The absorption trenches will be constructed parallel to the contours of the slope in accordance with Municipal Code. A minimum of 100' will be maintained between all components of the septic system and the proposed well and from any surface water in the area. The previous survey on the lot indicated a small area of surface water to the east of the house, near the existing septic tank. Our investigation revealed that it was not a natural stream or ponding area. it was not fed from anywhere uphill, and did not flow or outfall anywhere. It appeared to be a depression that was filling with effluent from the failed septic system. It is possible that it is result of a partial tank collapse. The depression has been filled in recently, and there is no surface water in it. A small rivulet or drainage was noted on the westerly portion of the lot. The septic system will be constructed 100' from this drainage. If the system is constructed in accordance with our design the following statements apply: ]. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely •'4A° : 4klb ‘3' 14110 Benjamin Schiller, P.E. y r.: ir Attachmentsio-r alp' '• t5104t/. 4" 1,��y�¢,/ U . S . SURVEY 3202 LOT 5 \ N 49'20'00' W 330.00' / \ � / \ / \ 98,037S.F. \ / 50' BLM EASEMENT \ 1 � 1 1 I, 1 he 1 1 p T ® j 1 , I I Existing well 1 11 he 1 f NI \ I 1 ` ` NOTE: I\ 1 r Place Foundation/ ` , \ croorn Cleonout // l III \ ® 1 FCO W \ \\ W g , . 1 /<500 Gallon Steel g s Septic ••nk g \ ,-.... z Garages- `` . • __ '36`�Pump Vault w/Aerocell Pump 650 GPO A rocell 1 and Floats ya° 7 Unit w/Jany Valve Ae ,o• ,y k- 45' Lon x 5' Wide ° x .5' Elective Depth %'TH1 c," Absorptipn Trench II mShad `- U *4! 11 ; ALTdRNATE SITE m \ NOTE; ‘ *; Nor Slopes >25X Within 50' the GroundwaterWithin 100' of the \ Proposed Septic System. No Conflicts with Wells or Septic 1 50.0 _ _� Sytems on Surrounding Lots.. LA J Decommission Septic Tank and \ Absorption Area in Accordance with Municipal Code. Exact Limits +kr. 50' BLM EASEMENT and Configuration Unknown. .,,rrt•1<K�+4%4 N 49'20'00' W 330.00' rr ...,,'SCJ I, alt sv. \ *•f 1 : • •th �` • . i• • • i LEGEND . ' ti SITE PLAN MT — Monitor Tube • *�; BENJAMI �.CHILLER •G` " FCO — Foundation Clean Out 1--.:1'-,'-.. No, CE-12592 �,+ TH — Test Hole vit j'•••9#41!1 P•�,�: SCALE 1" = 50' CO — Clean Out •1�'JFES:; of U .S. SURVEY 3202, LOT 5 DESIGN FACTORS: SYSTEM REQUIREMENTS: Three Bedroom System 5' Wide Trench System Perc. Rate: 40 Min./Inch Quanics Treatment System Application Rate: 2 GPD/SF .5' Drainfield Rock 3 Bedrooms * 150 GPD/Bedroom = 450 SF Absorption Area 450 SF/2 GPD/SF/5 SF (Width) *1 (Red. Factor)= 45 LF Trench Length THEREFORE: Construct a 45' Long x 5' Wide x .5' Effective Depth Absorption Trench at the Location Shown on the Site Plan. Place Distribution Line at 2' Above Original Ground. Total Depth to be 1.5' above Original Ground. Remove Organic Layer Below Trench and Place MOA Approved Sand. Maintain 100' Separation Between Wells in the Area and All Components of the Septic System. 6" Topsoil and Revegetation To Prevent Erosion 3 3 71 1 T 2" Insulation Geotextile Fabri. '0" _ V.////// //////el 6 6„ 4" Perforated PVC (Holes Dow Drainfield Rock 1.6., MOA approved sand 1'0" MOA approved sand 5' TYPICAL 5' WIDE TRENCH SECTION (NO SCALE) • ..��-a.t.�� ��•,P�� .........,.'♦♦1 NOTE: Grade Area Over Trench to Drain Away. • : stn ,ON '�♦♦ Minimum 6' Separation From Bedrock. Minimum 2' Separation From Groundwater. S. Minimum 100' Separation From Private Wells in the Area. BENZ IN SCHILLER '�(��a- Minimum 100' Separation From Surface Water or Streams:% •_ CE-12592 `: ♦♦A !i 7 1:1.• 4 + '1111raaaa+** I MUNICIPALITY OF ANCHORAGE �"1"\ilkA.V`1 4 �[� DEVELOPMENT SERVICES DEPARTMENT ���P x•'• 49141+ z4700 ELMORE ROAD ANCHORAGE, AK 99519-6650 �*.49TM �` 4 VA SOILS LOG AND PERCOLATION TEST , . Ben in Schiller P LEGAL DESCRIPTION: US SURVEY 3202, LOT 5 r�'iF,j,. Cn9t6220s2 �444�• � ANDERSON ENGINEERING 1kkZ,�PROFESSIOHP\��' PERFORMED FOR: 1\1�\x��'�� DATE: 8-3-2017 PROJECT No.: PARCEL ID#: 090-022-21 TECHNICIAN: SCHILLEF? / MILLETTE • Professional Engineers Stamp: DEPTH TEST HOLE 1 (feet) 1 SLOPE SITE PLAN 2 _ - SANDY SILT 3 -..-- - ' ML 4 5 , SEE SITE PLAN 6 l 8 ' BLUE CLAY 9 ,—__— 10------^ WAS GROUND WATER ENCOUNTERED? NO IF YES @ WHAT DEPTH DEPTH OF WATER AFTER MONITORING: I.5. 11— ' - DATE OF MONITORING: 8/16/17 12 r----:: GROSS TIME NET TIME DEPTH TO NET DROP 13 DATE READING (MINUTES) (MINUTES) IER CHES) (INCHES) (INCH 14 TEST HOLE PRESOAKED PRIOR TO TESTING: 15 8/3 1 9:36 Ott �� 2 10:06 30 0.75" 0.75" 3 10:07 0" 17 4 10:37 30 0.75" 0.75" 18 _ 5 10:38 0" • 19 6 11:08 30 0.75" 0.75" 20 PERCOLATION RATE: 40 (MIN/INCH) PERC.HOLE DIA. 6" (INCHES) TEST RUN BETWEEN: 1.5 FT. and 2.5 FT. COMMENTS: Test Hole Presoaked Prior to Percolation Test. Silt Layer at 8'is Impervious. l.,‘ N N [ i „......c...---- am - " + �y : !3' iJ zes Y ,Lxt ..„..a., „.... , pa i ./2.P. A I .�O l� • T, n ce i . i G R � 1 873 1 1 p l\ J J1. W a` _ 3 N. y L co I - ------ --lY/syn %'�'- _72 L "J Al.( ,fvg72-ir 74 ASBUILT SEWARD & ASSOCIATES LAND SURVEYING 694-0829 I HEREBY CERTIFY THAT I HAVE SURVEYED THE SCALE: / /"=yD ..om®ay.tt0 FOLLOWING DESCRIBED PROPERTY; �.OF A( r 4,1c.5-‘1_ ,-;;---..,:,33�Z Ea DATE- // ' gv,�h .-•'• --._S k• AND THAT NO ENC AOHMENTS EXIST EXCEPT AS 6/��j s�, . .„ ri INDICATED. IT IS THE RESPONSI�3ILITY OF THE _ ; 4�E TO DETERMINE THE EXISTENCE OF ANY 3RID a /4"----- OWNEREASEMENTS, COVENANTS, OR RESTRICTIONS f/.7io il, - d WHICH DO NOT APPEAR ON THE RECORDED SUBDI- VISION PLAT. UNDER NO CIRCUMSTANCES SHOULD FB ,..'ae � z `y. ANY DATA HEREON BE USED FOR CONS TRUCTI ON - ��z-Sa fi `tire ` '' OF FENCE LINES, OR FOR ESTABLISHING BOUND- D1�4WNi 3 „ rice...' ARY LINES. / - '`"`�"� Gr/J ~1: Time Date Insp ~-~UNICIPALITY OF ANCHORAGE ~ DEPARTMEN~PF HEALTH AND ENVIRONMENTA~ ?ROTECTION 825 L Street, Anchoraa~. Alaska 99501 2:00 p.m. #2: 10-3-77 Monday Buchholz 264-4720 Date Received: Time #3: Time Date Date Insp Insp September 30, 1977 e REQUEST FOR APPROVAL OF INDIVIDUAL SEWER AND WATER FACILITIES Lending Institution Request: Security Pacific Mortgage Company Mailing Address: Property Owner: Mailing Address: 1101 East Tudor Road, Suite 190 Robert B. Hancock Star Route Box 8535 Indian Phone:276-1933 Phone:653-8171 Legal Description: Lot 5 Section 10 U.S.S.S 3202 Single Family Residence: (x) Number of Bedrooms: Multiple Family Residence: ( ) Number of Bedrooms: Well System: Individual well ( ~ Community/Public System ( ) Permit ~ Depth of Well 80' Well Log on File Construction Sewage Disposal System: Permit # Septic Tank Size Absorption Area On-site System Tx) Installed 1977 Public Utility ( Installer Manufacturer Soils Rate Material Distances: Well to Septic Tank to Absorption Area to Sewer Line Nearest Lot line Absorption Area to Nearest Lot Line ~Page Two '~ ~ Department of Health and Environmental Protection Request for Approval of Individual Sewer and Water Facilities Legal Description: Lot 7 Section 10 U.S.S. 3202 Comments: ~L --~ LF~/~ I/~_ ~'~ .~ Affadavit Attached: ( ) Approved 1~ (~~ Department Worksheet: Letter Attached: ( ) Da%e: - t ? Date: f(~ --'/~--'"~ 7 ( ~UNICIPAL.ITY OF ANCHORAGE ~f[~ Department of Health and Environmental Protection 825 L Street, Anchorage, Alaska 99501 264-4720 quest for Approval of Individual Sewer and Water Facilities Property Owner: Mailing Address: Name of Buyer: Mailing Address: Phone: Lending Institution: Mailing Address: ~/ ¸5. Realtor/Agent: Mailing Address: Legal Description: ~ Street Location: Single Family Residence: Multiple Family Residence: Phone: (~Number of Bedrooms: ( ) Number of Bedrooms: Water Supply: *Individual Well If Individual Well, well depth If Community System, name of system Public/Community System ( ) Sewage Disposal System: On-site System (~ Public System If On-site System, date of installation: ~/~/~ ~ *NOTE: A well log is required on ALL wells drilled since 6/75. 3/77 DAft INDIVIDUAL AL DEPARTMENT OF NE ~LTH AND SOCIAL'SER¥,,~eS -... OIVISION OF P )BLIC: HEALTH LabNo ~ INDIVIDUAL AH ~SEMI-PUBLIC :BACTERIOLOGICAL WATER ANALYSIS .SANITARIAN'S REMARKS., Diameter of ~Vell\ DeoTn Well Casing Length al Water Deplh Offset in PUMP LOCATION: El n Well [~ Bosemem [~ n gosemem BA~TJ~RIOLOGICAL WATER ANALYSIS RECORD READ INS:i-RUCTIONS ON REVERSE SIDE BEFORE COLLECTING SAMPLE EMg ~. .ocloSe groth 2~4 hfs Coliform Den~ This omo .sis indrcotes Coliform Organisms to be. AGAR 48 hfs gram's stain (Most Drobable No. per 100cc Oetober 4~ 1977 Security Pacific Mortgage 1011 Esst Tudor Road Suite 190 Anchoragev Alaska 99507 Subject: T10N PlW 'Section 10 Lot 5 US Survey 3202 The well serving ~he s%lbject residence was inspected on October 3, 1977. The construction is not approved. Upgrading the well to meet code requirements consist of installing a floor drain f~m~ the well p~ to a hillside. This department would grant a temporary approval if f%mds are escrowed. If there are any further q~lestions, please contact this office at 264-4720. sincerely, Les No Buchholz, Sanitarian Robert ~ancoek Star Route A Box 8535 Indian~ Alaska 99540 MUNICIPALITY OF ANCHORAGE OJ Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Parcel I.D. 090-022-21 Certificate of On -Site Systems Approval Expiration Date: 9— Z/ -2,0 2 Z 1. GENERAL INFORMATION Complete legal description US Survey 3202 Lot 5 / T1 ON R1 W SEC 10 Location (Site address) 923 Powerline Rd, Indian, AK 99540 Current property owner(s) Mailing address Real estate agent Gale & Thomas Wozencraft Day phone (918)813-9116 923 Powerline Rd, Indian, AK 99540 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 Day phone 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well Private Septic RE Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Distance: Received by: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 5 5 0 Date of Payment 7 a0Q a i Receipt Number_ 0 2 $� COSA# 65CPa 1 lab' Date: Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm Forge Engineering (M.J.) Phone (907) 522-7773 Address 1399 W. 34th Ave Suite 101, Anchorage, AK 99503 Engineer's Printed Name Benjamin Schiller, P.E. Date 3/30/2022 TH 6. DSD SIGNATURE 3 � ��' •' ; System #1 Approved for bedrooms r�—'.r�� Y pp Benham r Schiller / System_#2 Approved for bedrooms 3/E 30/222592 Disapproved �i�PRO FESSION Conditional approval for bedrooms, with the following stipulations: i By ----'Original Certificate Date: 31 rZdZZ The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon -the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist blue sheet Legal Description: US Survey 3202 Lot 5 / T10N R1 W Sec 10 Parcel ID: 090-022-21 If more than 1 septic system on lot: COSA Checklist # of Structure served by this system A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled Unknown Total depth 80* ft Cased to Unknown ft W Sanitary seal is functioning correctly ❑® Wires are properly protected Casing height (above ground) 12** in. Date of flow test for COSA 3/28/22 Well production at time of test 3.2 gpm Water storage tank volume gallons Well disinfected for coliform test? ❑ Yes IN No 9 Coliform bacteria is Negative Nitrate 0.580 mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L Fg] Arsenic less than MRL (ND) Collected by Forge Engineering Date of Sample 3/28/22 Static water level at beginning of test 19 ft. Comments *Per 10/3/77 MOA approval paperwork **Met code in 1977 B. TANK DATA Age of tank(s) 4 years Tank type/material STEP/Steel Measured operating fluid level in septic tank 43 Fm_1 Standpipes/foundation cleanout per record drawing Date of pumping D. ABSORPTION FIELD DATA Wide Trench Which system tested (date installed) 11/13/2017 ❑® ALL standpipes present per record drawing Total measured depth from grade 2.7 ft (max) Measured depth to pipe invert from grade 2.4 ft (min) ❑ N/A — pressurized field ❑ Monitor tubes go to bottom of effective. If not, state depth into effective 0.3 C. LIFT STATION Q Required maintenance completed Age of lift station 4 years Lift station material Steel Comments: 8/13/2021 ARM Septic Services Adequacy test date 3/28/22 Results [] Pass For 3 Fluid depth prior to test 6 - Water added 470 gal New depth 0 in Elapsed time 1440 min 0 bedrooms H ❑® Code -required soil cover over field Final fluid depth in ❑ System presoaked Absorption rate >450 gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) _ date of test) If yes, enter date Gallons introduced gallons Comments/Deficiencies: Absorption field insulated. COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' P/ Yes Community Sewer Manhole/Cleanout > 100' r7✓ Yes if No ft M Yes if No ft Neighboring Tank > 100' Q✓ Yes if No ft Private Sewer/Septic Line > 25' F✓ Yes if No ft Absorption Field on Lot > 100' Yes if No ft Holding Tank > 100' F/ Yes if No ft Neighboring Absorption Fields > 100' 0✓ Yes if No ft Water Main > 10' Animal Containment > 50' [✓ Yes if No ft F71 Yes if No ft Yes if No ft Water Service Line > 10' 0✓ Yes if No Manure/Animal Excreta Storage > 100' If septic tank is under driveway Community Sewer Main > 75' Q✓ Yes if No ft -❑✓ Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' P/ Yes if No ft Surface Water > 100' Yes if No ft Property Line > 5'✓0 Yes Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' Q✓ Yes if No ft Private Wells > 100' 0✓ Yes if No ft Water Main > 10' 0✓ Yes if No ft Community Wells > 200'✓0 Yes if No ft Water Service Line > 10' 0✓ Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' E✓ Yes if No ft If absorption field is under driveway comment below Property Line > 10'✓Q Yes if No ft Wells on Adjacent Lots: Water Main > 10' Yes if No ft Private Wells > 100' Yes if No ft Water Service Line > 10' Yes if No ft Community Wells > 200' Yes if No ft Surface Water > 100'✓Q Yes if No ft F. ENGINEER'S COMMENTS G. ENGINEER'S CERTIFICATION / certify that / have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. COSA Checklist yellow sheet OF'.4C�` l TM BenjarriSchiller �������� • , C 2 3/30/22 kk�,PROFiSSI �t�"�®�4-ate Maintenance Checklist- Advanced Treatfnent System Ope��mnu|ChenkistAdvanoedTeahnen System Legal Description: Street Addr Service provided on: Date: Time: Service provided by� Company, Technician: Date of last service: By: (��o �ul Other: 1.Type ofAe,nceUTreatment System: [��catU-Aero ellTreatmontSystem r-1 Cat III -AemCe||Treatment System 2.Conditions admedia filter: ptable FUnacveptable a. Evaluate presence ofodor within lOftofperimeter ofsystem: �None El Mild 171 Strong Chemical F. Sour 0 Source ofodor, ifpresent: 3. Manhole Risers and Pipe Caps: n<A-oeptab|o 0UnaoceptaWe a Covens intact.- Sk7es U. Method ofsecuring covec o Insulation presenton all !ids? ��Yes El No \ d. Any plumbing leaks orwater mtruemn�^L��'"" ��No ' =�0�1 e ���w��������n�ne�- �� �Nu�� � /LVenting/Air supply: ptable Unacceptable a. Air supply unit operating properly. N]+es FlNo b. Ventmgappears operable, [��ex ��No �� ��ed�sur�oe L���uepteb|e LJ Unacceptable a. Giomatonourfece []Yea b� Uniform spray pattern, &�^~s d, Ponding in/on media E'Yes e Plugging/clogging o/nuzz|ea. FYen [ Media appears tobesettling. El Yes g, Appropriate maintenance performed, N7us h� Pest activity at surface, E] Yes 6. Effluent quality a. Effluent odor after passing through media fiUec b Effluent color after passing through media filter 17V]]Old Glenn 2r'm [�No No No 5�/vo [:]Nn so ;—�Mild El Strong EY-elear 17 Brown F-1 Black ARM Septic Services, T LLC 7. Tasks for recirculating/discharge flows: Ll Unacceptable a. |fapplicable, Jandyvalve functioning: FYns El No N/4 b. |fapplicable, JandyValve basin dry: El Yes No FS N/4 o.Cleaned collection systnminAerone||unit: 10 Yes "No L-Ve"N'ntNeoesaary d. Design recirculation ratio- 80 : 28 e. Actual recirculation ratio (Estimated): So -z'&? 8. Pump System: []Unacceptable o. Control panel inAuto: Ki��s F�Nu 1\�- b Timer settings !FS Panel (No Override timer): -!K�es ON _~7— c^\OFF: Override ON, Override OFF: c. Floats in correct placement: S"Yes d, Floats working properly, L�<Y~^ e High water alarm operational: [�4e" �— rannoouni -- [ High water �� g Pump Run Counts- h. Pump Run Tlme� | Float Error Counts, N/A J Total Override Cnunts.LlNA\ h Effluent Filter serviced av~. !� 'Tank lids secured after inspection: 1R'es no Weep hole functional- ��e" ` No No \ � `�u/ J/�,L FNo L�No No 8. Primary Tank: FlUnaoceptab|e e. Sludge and Scum level checked- ��< o b Sludge/Scum |eve|ai1st u 2nd: 7 « 3 c, Tank needs to be pumped: FYes '�- No d. Water softener backwash discharging onsystem? 0Yes 17 No e How many people live onthe oyxtam?� - [ Tank lids/caps Secured after inspection: s 1171No g Last Date Tank pumped: 10. Drainfield: o. Type ofDmmfield(circle )Oe�Tmn� b. Deo�nE�x��ode�h: tide ~� c Checked Liquid Levels inDramhe|d� I�Sryes FlNo MT#1Liquid Leve[ Inches Ml#2Liquid Level: Inches K47#3Liquid Level: Inches K8T#4Liquid Level: Inches d. |sthere any surfacing effluent?� 0Yey NN ,~ 179]]Old Glenn Highway 11. Is the remote monitoring system functioning? (ifno. describe in cumnnentn)[�Y�^�+N' a. Type of Monitoring system: b. Phone line working? Yes 17 No $i�'N/A 12. Does this system receive an advisory notice/warning? (if so, describe in comments) k Ll No 13. Is the system in satisfactory condition/pass inspection? (if no, describe in comments) 171 Yes No Other Comments: \�nvp ��-.. Service Provid,�r -Date: 17933 Old 6teillh�Mighway *Chugiak, AK 99567 office/fax: (907) 688-9433 Email.: ARMService5AK@outtook.coni (PAGE 3 of 3) o IES INIUNICIPALITY OF ANCHORAGE ADVANCED NN"As'rFNN7ATER TRI ATAMENTSYSTEM MAINTENANCE, AND REPAIR AGRET":I11?NT TI 1lSX-'IAINT1--;NANCT-` AND REPAIR herein the "AGREE MENT" made and entered into as of this Day of ol'20'27- -, by and between S"" -ea Le"ei"tlie"OWNEIZ,"atidthe NILiiiicil)lity of Anchorage, herein the "MUNICIPALITY", inaccordance with Anchorage Municipal Code (AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this Agreement agree as follows: L Advanced Wastewater Trell OVI ent Sys te in s. The NItiiiicipilitygrants permission t(.)the Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as located at (legal description) 9 2 S' 'Pot.) AV- Ciqs-�/o 2. Maintenance, Repairs and Alterations. (Owner is required to read, understand and initial each section) CLS -7';�C Throughout the ierrn of this Agreement, the Owner shall enter into a service agreement with an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative. The AWWTS shall be maintained in a satisfactory condition capable of performing as designed and producing treated septic effluent in '21 accordance with the equipment's approval for operation in the Municipality. It shall be the responsibility of the Owner during the term of this Agreement to pay for all repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This includes an annual maintenance fee (typically S400 to nZf�Z Owneraorees thatonly maintenance and repair personel approved by the Municipality or the manufacturer's representative will inspect and make any necessary maintenance, repairs or permitted alterations to the system. /0 � -rW0 Owner acknowledges that regular maintenance of an AWWTS reduces the potential Failure of the System, Which Could include sewage backup and costly repairs or drainfield replacement. (rev. 05/18/2018) Page 1 of 3 I jtzU Owner acknowledges that the ►'v1ttnicipality may request records of maintenance and repairs from the tnanufaclurer's representative or maintenance provider. Owner acknowledges that the tine for failing to maintain and repair an AWwTs may be assessed in accordance with AMC 14.60.030. Owner agrees to grant the Mill, icipality reasonable access to test and inspect the AWWTS. The Municipality will hive at least 24-hour notice. CZJ Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On -Site Systems Approval. r Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendorfinstaller and approved by the Municipality are the governing guidelines for the construction, maintenance and repair of the Owner's AWWTS. Owner agrees to maintain remote monitoring ofthe AWWTS as required by the AWWTS approval. 3. Term. The term of this Agreement shall begin on the date of approval by the Municipality to operate the installed system, or upon transfer of title, and shall continue .while the AWWTS is operational or until title is transferred. 4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this Agreement shall in no way constitute a waiver of the provisions, nor in any way affect the validity of the Agreement or any part hereof, or the right of the Municipality thereafter to enforce every provision hereof. 5. Amendment. This Aareement shall only be amended by authorized representatives of the Owner and Municipality. Any attempt to amend this agreement by either an unauthorized representative or unauthorized means shall be void. 6. .Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Agreement. 7. Severability. Any provisions of this Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Agreement. (rev. 05/18/2018) Paae 2 of 3 -., OWNER4�,ra 5�Z-ZZ !J (signature) Date: St - STATE OF4=--� eoJUTr of. )ss. T;4!RlI_ITT7 IGI 17 TI&Tl)i' -r-. � ) f r4 t."f-f-111aC7 The foregoing instrument was acknowledged before me this 'day of , 20?--, by LrcLi k SoCyE £��/ �r� tic—,t v xw«,tj— orZ7t . RGI,�r OFFICIAL STAMP NOTARY PUBLIC FOR,(7 6a� SEAN PATRICK CHARLTON My Commission expires: NOTARY, PUBLIC-OREGON COMMISSION7 _ MY COMMISSION EXPIRES APRIL 6.2024 MUNICIPALITY: y: (signature) name) Date: S- -31 - Title: (rev. 0/18/2018) Page 3 of 3 1a9 10 /1 • h6 7S \r �1�1't,t� i� l A'11 rc . B� • Municipality of Anchors ,`�'��`' On-Site Water and Wastewater Prog �� (907) 343-7904 0. M ,., SAFETYS w b Certificate of On-Site Systems App :` '43,11 6 a 1- � Parcel I.D. 090-022-21 Expiration Date: a 0 • 0 1. GENERAL INFORMATION Complete legal description US Survey 3202 Lot 5 T10N R1 W Sec 10 Location (site address) 923 Powerline Rd. Current Property owner(s) Gary Mohar Day phone Mailing address 923 Powerline Rd. Bird Creek, AK 99540 Real Estate Agent Tracy Perryman Day phone 850-417-1453 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Q Individual EJ Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: Received by: (/i4 ZULtZ./ °Tle Date: 5/2,/ J COSA to be released to the engineer,unless otherwise requested by the engineer. COSA Fee $ oq0,5D Waiver Fee $ Date of Payment 5430 Date of Payment Receipt Number 0 86(2. ID Receipt Number COSA# Of7CI 7 1l 8 a Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Forge Engineering Phone (907) 522-7773 Address POBox 240773 Anchorage, AK 99524 Engineer's Printed Name Benjamin Schiller, P.E. Date 05/2/18 6. DSD SIGNATURE 0*: • TM System#1 Approved for J? bedrooms 4111'- enla in Schiller Q System#2 Approved for bedrooms #,T<• F9FOp wpsi Disapproved Conditional approval for bedrooms, with the following stipulations: - OF Ajvc, : ON-SITE : WRTER AND • WASTEWATER o PROGRAM 'o „.,'��AIT c^:p\I'C‘ By: `I�A)PJCI CQJU1APP Original Certificate Date: I nd r 0 I d The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet_S c If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: US Survey 3202 Lot 5 T10N R1W Sec 10 Parcel ID: 090-022-21 A. WELL DATA Well type Private If A, B, or C provide PWSID# Well Log (Y/N) N Date completed Unknown Sanitary seal (Y/N) Y Wires properly protected (Y/N) Y 80* Unknown Total depth ft. Cased to ft. Casing height (above ground) 12 in. FROM WELL LOG AT INSPECTION Date of test Unknown 4/10/18 Static water level ft. 19 ft. Well production g.p.m. 3'0 g.p.m. WATER SAMPLE RESULTS: Coliform Neg colonies/100 mL Nitrate 0.481 mg/L Arsenic 7.44 ug/L Date of sample: 4/10/18 Collected by: Forge Eng. B. SEPTIC/HOLDING TANK DATA Tank Type/Material STEP/Steel Date installed 11/14/17 Tank size 1250 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) Y Date of pumping Pumper New Construction/ Quantics CAT II AWWTS C. ABSORPTION FIELD DATA Date installed 11/13/17 Soil rating (g.p.d./ft2 or ft2/bdrm) 2.0 System type 5 Wide Length 45 ft. Width 5.0 ft. Gravel below pipe 0.5 ft. Total depth 4.0 ft. Eff. absorption area 225 ft2 Monitoring tube Y Depression over field N Date of adequacy test New Constr. Results (Pass/Fail) For bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) If yes, give date D. LIFT STATION Date installed 11/13/17 Size in gallons 1250 Manhole/Access (Y/N) Y "Pump on" level at 48 in. "Pump off' level at 42 in. High water alarm level at 52 in. Datum Bottom Cycles tested ARM Services Meets alarm&circuit requirements? Y E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot >100On adjacent lots �100 Absorption field on lot >100On adjacent lots >100 Public sewer main '75' Public sewer manhole/cleanout 100 Sewer/septic service line >25' Holding tank >75' Animal containment areas >50' Manure/animal excrete storage areas >100' SEPTIC/HOLDING TANK ON LOT TO: Building foundation �' Property line >5' Absorption field >5' Water main Water service line Surface water Wells on adjacent lots 100 ABSORPTION FIELD ON LOT TO: Property line Building foundation Water main >10' >100' >10' Water Service line Surface water Driveway, parking/vehicle storage Curtain drain None Noted Wells on adjacent lots �100 F. COMMENTS *Well depth taken from existing Muni records 4����.1> G. ENGINEER'S CERTIFICATION OF lt� I certify that I have determined through field inspections and �,rg'<P*• `4�.t1 review of Municipal records that the above systems are in j*; • • TH i' •.*it conformance with MOA COSA guidelines in effect on this date. 1 IF •ey Engineer's Printed Name Benjamin Schiller, P.E. % •• r . Buisaurin Schiller : j Date 5/2/18 �+��cislF9F CE •12592••��� �� �pROFESS\O . COSA brown sheet 10-10-12.doc ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT BETWEEN MUNICIPALITrY OF/ANCHORAGE f� AND 7:644 is--& Lc d l� 12��L•tr.. TV` THIS MAINTENANCE AND REPAIR AGREEMENT made and entered into as of this Day of of 20 17, by and between i e•-•'(>&le 1e)o, e4cr'� herein the"OWNER,"and the Municipality of Anchorage,herein the "MUNICIPALITY." In consideration of the mutual covenants contained herein, the parties to this Maintenance and Repair Agreement agree as follows: I. Advanced Wastewater Treatment Systems. Municipality grants permission to Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as Quanics Aerocell System located at(legal description). US Survey 3202 Lot 5 770 Ai )'Z,i 4"1 _cEc._j 0 2. Definitions. Alteration. Any change to the design or function of an AWWTS that includes the installation or removal of any parts, components or pieces not included in the original construction permit and design. Certificate of On-Site Systems Approval (COSA). An approval by the Municipality of existing water and wastewater disposal systems given at the time of property sale and title transfer in accordance with Anchorage Municipal Code(hereinafter, "AMC") 15.65. These approvals certify that service and maintenance provider approved by the municipality and the manufacturer of the AWWTS for the entire term of the AWWTS. In addition, it shall be the responsibility of the Owner during the term of this Maintenance and Repair Agreement, and any renewals thereof, at the owner's sole expense,to pay for any and all: (i)repair(s), (2) maintenance, (3) adjustment(s), (4) replacement costs, and (5) inspection costs. B. Owner agrees to comply with all applicable ordinance, laws, regulations, rules and orders for the AWWTS. C. Upon request by the Municipality, the owner agrees to provide the Municipality a written schedule of routine maintenance and repairs which have been performed on the system. When a record of maintenance is documented and maintained by the system vendor,the owner agrees to allow the Municipality access to this information. D. Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be assessed in accordance with AMC 14.60 for improper discharge. E. Owner agrees that only maintenance and repair personnel approved by the Municipality will inspect and make any necessary maintenance, repairs or permitted alterations to the system. F. Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS upon 24 hours written notice. G. Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On-Site Systems Approval. 8. Jurisdiction: Choice of Law. Any civil action arising from this Maintenance and Repair Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Maintenance and Repair Agreement. 9. Severability. Any provisions of this Maintenance and Repair Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Mainten• ce and Repair Agreement. OWNER: WZ-Zeil\c* -d.rri By•, • � / (signs re) Date: 1 414 NO Z.ACr� (print name) C C k,kit STATE OF ALASKA ) )ss. THIRD JUDICIAL DISTRICT ) l The foregoing instrument was acknowledged before me this AIay of ft p r i 1 , 2018 ,by Itoh•e$ o,.,.::1 X6112 wore NOY PUBLIC FOR ALASKAjotozatAN My Commission expires: 0 6/Q X/ boa 8, ,l MUNICIPALITY://�� By: ` ,� CAM -Q (signature) Date: 00/1S/ R(Lk) c Ca -c o i l (print name) Title: ARM Services, LLC Quanics Maintenance Contract,Addendum A(2018 edition) For the purposes of the contract, the term "owner" or "owner(s)" shall refer to the legal owner of the system, or the authorized representative. The term "ARM" shall refer to ARM Services, LLC. PURPOSE: As required in the MOA(Municipality of Anchorage), the Quanics Aerocell system requires a maintenance contract with a certified maintenance provider.ARM Services, LLC is a certified Quanics maintenance provider. This contract covers one year of Quanics system monitoring, inspections, and maintenance, which will start upon receipt of payment. This contract will include a minimum of one inspection per year, which is covered under the $425 annual.fee (see"fees" for reduced rate for a brand new system). SERVICES: The services currently offered by ARM for the purposes of fulfilling this maintenance contract include: • At least one inspection and servicing of the system per year. Service work includes (but is not limited to) fitter cleaning, nozzle cleaning, inspecting of components and observing them functioning, checking drainfield liquid levels, and testing system operation. • Annual report, indicating the status of the system, and any required repairs. • Availability to respond to alarms or callouts. • Availability to repair system, make adjustments, and technical assistance. if any major maintenance, repairs or other items are required (other than the minimum filter cleaning, nozzle cleaning and inspecting of the system), these items shall be completed at an hourly rate of $105/hour+ material costs. If ARM Services, LLC (ARM) responds to any alarm conditions or call-outs (or completes service work/ repairs or troubleshooting), whether notified by the Quanics unit via phone line or from tenants/owners, a two hour minimum of billable time applies at $105/hour. If an alarm condition exists,ARM shall have 48 hours to respond to an alarm. If ARM responds to alarms from 6pm-11pm, time shall be billed out at$157.50/Hr (2-hr min.). If ARM responds to an alarm from 11pm-8am, or during weekends or holidays, time shall be billed out at$210.00/Hr (2-Hr min.). If such an alarm or malfunction situation arises, the owner(s) shall have a contingency plan which is to include an emergency pumping of the system (via septic tank pumping service) and/or restriction of water usage, to provide relief until the system can be inspected by ARM during reasonable hours. The owner(s) phone number is required to be input into the remote monitoring system in the Quanics panel, and the owner(s) are responsible for being the primary responders to any alarm conditions, whether contacted via phone call from the Quanics, or by someone else reporting a problem or alarm. If the owners respond to an alarm, and ARM is contacted to provide technical assistance over the phone, this time shall be billed out at$105/hour, with a .5 hour minimum (For example, if during a peak flow event like a Christmas party, if the Quanics system cannot keep up with a large surge of water and goes into alarm, the system can easily be manually pumped down by the homeowner while receiving technical assistance from ARM via telephone call or text). Should the system require pumping (via pump truck) for emergency reasons or as part of routine maintenance, the pumping fees are not covered under the annual. $425 fee. Should this Quanics unit utilize a RYMSYS remote monitoring system, the annual RMSYS fee is not included (or covered by ARM) under this contract. This contract shall renew automatically each year, unless the owner provides written notice with their intent to dissolve the contract. Payment is due at the beginning of each 1-year cycle, otherwise this contract has been broken, and ARM will not be providing any maintenance or monitoring services. FEES: • Annual maintenance contract fee: $425.00/year (A reduced rate of$225/year is provided for brand new systems, for their first year only, as the maintenance requirements are less) • Hourly rate (Mon-Fn, 8am-6pm): $105.00/hour • After hours rate (6pm-11pm): $157.50/hour • Hourly rate for weekends, night-time (11 pm-7am), and holidays: $210.00/hour 24738 Chugiak Drive*Chugiak,AK 99567 Ph: (907) 317-9433 office/fax: (907) 688-9433 Email:ARMServicesAK®outlook.com ARM Services, LLC OWNER RESPONSIBILITES: The owner(s) have read and understand the Quanics installation manual and the Quanics owners/ operation manual, and agree to operate the system in accordance with those manuals (available from Garness Engineering in Anchorage,Alaska). The owner(s) of this system are required to be trained on how to respond to alarms, how to identify potential problems, and how operate the system.Although ARM will be responding within 48 hours to potential alarms or problems, it is important for the owner(s) to understand the basic workings of the system, and to be prepared to respond to an immediate problem. This contract is absolutely contingent upon the system being maintained and kept in good working order. In short, if at any time the owner(s) put off any maintenance (or repairs) on this system, use the system in an abusive manor, or do not keep a working phone line hooked up to the panel (this includes maintaining a working remote monitoring system and any renewals required), this contract is null and void (ARM will not be providing a refund of the annual fee). See additional owner(s) responsibilities under"Disclaimer". DISCLAIMER: ARM is not responsible or liable for any damages to the system or the residence due to (but not limited to) the following reasons: • Performance of the septic system • Deferred maintenance • Abuse of the septic system • Workmanship associated with the installation of the system • Engineering design or inspection work associated with the septic system • Damages to the system • Failure of any of the septic components • Failure to keep a working phone line connected to the system • Lapsing of a remote monitoring contract (such as RMSYS) ARM is not associated in any way with the engineering of the septic system, or the corporation "Quanics".ARM does not offer or imply any warranty of the Quanics system components. Simply put, ARM is helping to monitor and maintain the existing septic system, solely at the direction of the owners. The owner(s) are fully (and solely) responsible for the septic system and its operation, the management of the system, its performance, and directing what is and what is not to be done by ARM regarding the system. Limited warranty: ARM does not offer nor imply any warranty of the workmanship of the existing septic system.Any issues with the system, components, and workmanship are not covered under a warranty by ARM. ARM does not offer or imply any warranty of the Quanics system or its components.ARM offers a limited 1-year warranty for workmanship associated with repairs made to the Quanics Aerocell system. By signing below, the�ov�er or authorized representative of this system agrees to all of the terms of this contract, nd�zes M �. provide annual services for this system. Signature: /C y' . Date: W-z-VA) /W - G /� `7 Property address/site description: I POOcr/iL _ P.c-1 7 - '\- Cre k � 4.)C- ct1--S-Id D GCS -►'e-J 332.132- 4.071-3- 7KnV Q`t 3-EC-/' 24738 Chugiak Drive*Chugiak,AK 99567 Ph: (907) 317-9433 office/fax: (907) 688-9433 Email:ARMServicesAK@outlook.com