HomeMy WebLinkAboutVILLAGE PARKWAY ESTATES Lot 1 Tract A Plat# 80-156 S-5348A
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTAL HEALTH CASE REVIEW WORK SHEET
[] PLATTING BOARD [] PLANNING & ZONING
CASE NUMBER NAME
S-5348A Lot 1 and Tract A Village Parkway Es%ares
DATE RECEIVED
May ].4, 1980
COMMENT TO PLANNING BY
May 28, 1980
FOR MEETING OF CASE OF
71-014 (Rev. 2/787-..
A chora e
825 "L" STREET
ANCHORAGE, ALASKA 99501
(907) 264-4111
GEORGE M, SULLIVAN~
MAYOR
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
August 18, 1980
Steve Chronic
H.V. Lounsbury and Associates
723 West 6th Avenue
Anchorage, Alaska 99501
Subject: S-5348A Lot 1 and Tract A Village Parkway Estates
The final proposal,, as submitted, has been reviewed and the
following items noted:
(1)
A perc test will be required prior to a permit issuance
on Lot 1 in the designated sewage disposal sire bordering
Villages Scenic Parkway, northwest corner of Lot 1.
(2) 'The proposed disposal site located on the southwest
corner of Lot 1, is not acceptable due to shallow bedrock.
(3) A multi-french design will be necessary for use in the
disposal site located near Villages Scenic Parkway°
If there are any furthe~ questions~ please call this
department at 264-4720.
Sincerely,
l~e8 N. Buchholz,
Senior Environmental Specialist
LNB/ljw
DATE:
TO:
FROM:
SUBJECT:
Anchor ge
MEMORANDUM
May 6, 1980
Planning Department
Health and Environmental Protection
S-5348: The Villages Village Parkway Estates
After a meeting with th~ developer's engineer, this department
has no objections with the following proposal~
(1) Eliminate lot line between Lots 3 and 4 and label as
Tract.
(2) Relocate Lots. 1 and 2 to the south. This should place
test hole 2-A and 3-A on Lot 2. Lot 1 should be at
least lb acres.
(3) Prior to final approval, sewer systems on Lots i and 2
shall be shown regarding, designated installation sites
on the plat.
(4) The "tract"(Lots 3 and 4) can only have a single family
dwelling and sewer installation site shall be designated
on the plat prior to final approval. A note on the plat
addressing these single family dwelling item is requested.
Les N. Buchholz, R.S.
Senior Environmental Specialist
LNB/ljw
~BLE
F.T 2 [Y~" BC
)CK '
fl
MONUMP~'~ FLUSH WITH O.G,
558,67
HVL
Lot I \
101,840
2.~34 Ac:- \
\
ATA PER PLAT 77-106 X
/2" ALUMINUM (~AP MONUMENT)~
REBAR:
3745
FOUr, ID IN GOOD
CONDITION, FLUSH
WiTH W/P
l i!
LEGEND
CURVE · SCHEDULE ~'-' - ~
PROPOSED $[WAGE DISPOSAL AREA DRAWN
W44 \Ac.
Lot 1
10[,840 SF
2.34 AC. \
/
// /
Itl /
TR 9
P- 077- ICG J
I
NO~rARY $ ACKNOWLEDGEMENT
ACCEPTRNC[ OF DEDICATION BY
.AT
--.. -"% .,~,__
DTI002157
VILLAGE PARKWAY ESTATES
LOT] ~ TRACT A
A SUBDIVISION OF TRACT 5
THE VILLAGES
1980-693