Loading...
HomeMy WebLinkAboutWELLMAN LT 2Onsite File Wellman Lot 2 #018-281-24 PIPE MATERIAL House to tank Tank to Installer D3034 drainfield D3034 A+ HOME SERVICES Drainfield D3034 co/MTD3034 Inspector MOA AND GEG BENCH MARK (Assumed elevation) 100.00 ft Inspection 15` 7/14/2022 2�d 7/15/22 Location and description 3'd 7/15/22 4m 7/18/22 BACK DOOR THRESHOLD ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp � Foop Conditional Approval: Date o �� '" jt; Septic System .J f y A, Garn ss: CE -79 Approved Date Z 2 O��s Note: this approvalfiles not include well permit requirements. ��pap,ofessto"'O\ #AECC884 :v 05/02/18) Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP211324 PID Number: 018-281-24 Dwelling: 0 Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New 0 Upgrade Name PATRICK NELSON ABSORPTION FIELD EAST/WEST ❑ Deep Trench X Wide Trench ❑ Bed ❑ Mound Site Address 3540 TWILIGHT LANE *ANCHORAGE, AK ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 1-509-378-5266 3 1.2 GPD/SF 6.74/6.75 (MAX) Ft LEGAL DESCRIPTION Depth to pipe invert from original grade JGravel depth beneath pipe SEE DWG. Ft. 0.52/0.52 Ft. Subdivision WELLMAN; LOT 2 Block Lot Fill added above original grade Gravel length Township Range section SEE DWG. Ft. 40/40 (80 TOTAL) Ft. Gravel width 5/5 Ft. Beds: Number of Lines Distance between lines SEPARATION DISTANCES To Septic Absorption Holding Sewer Lift Station Total absorption area Number of trenches Ft. Dist. between trenches From Tank Field Tank Line 400 Fe 2 6'+ Ft. Well 100'+ 100'+ 25'+ TANK ❑ Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Capacity GREER TANK 1000 Surface Water 100'+I 100'+ Gal. Material Number of compartments Lot Line 5'+ I 10-+ NA PLASTIC 2 Foundation 110,+1 10,+ LIFT STATION Manufacturer Capacity Remarks PER CONTRACTOR, THE OLD TANK WAS DECOMISSIONED PER UPC Gal. OLD DRAINFIELD WAS ABANDONED IN PLACE Alarm location Electrical installed by PIPE MATERIAL House to tank Tank to Installer D3034 drainfield D3034 A+ HOME SERVICES Drainfield D3034 co/MTD3034 Inspector MOA AND GEG BENCH MARK (Assumed elevation) 100.00 ft Inspection 15` 7/14/2022 2�d 7/15/22 Location and description 3'd 7/15/22 4m 7/18/22 BACK DOOR THRESHOLD ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp � Foop Conditional Approval: Date o �� '" jt; Septic System .J f y A, Garn ss: CE -79 Approved Date Z 2 O��s Note: this approvalfiles not include well permit requirements. ��pap,ofessto"'O\ #AECC884 :v 05/02/18) PERMIT NUMBER: OSP211324 NOTE: PIPE LOCATIONS ARE SHOWN PER GEG SHOTS TAKEN WITH LEICA DISTO S910 LASER DISTANCE METER. SWING -TIES TO HOUSE CORNERS WERE GENERATED IN AUTOCAD. WELLMAN; LOT 1 1 I APPROXIMATE LOCATION OF I 100' WELL RADIUS / / a? : V, s -7')I / z RECORD DRAWING / TWILIGHT LANE \ B \ NEW 1000 GALLON HDPE GREER TANK NEW DRAINFIELD - / ffAF Ao. 7.71 \�C GARNESS ENGINEERING GROUP, Ltd ENGINEERING SALES CONSULTING 3701 E. TUDOR ROAD, SUITE 101 -ANCHORAGE, AK 99507 - PHONE (907) 337-6179 -FAX (907) 338-3246 -WEBSITE: -gemessengineenng.com PREPARED FOR: PHONE NUMBER: PAGE NUMBER: PATRICK NELSON 509-545-3772 2 OF 3 LEGAL DESCRIPTION: DRAWN BY. WELLMAN; LOT 2 D.J.G. TYPE OF WORK: DATE: �,_ RECORD DRAWING OF SEPTIC UGPRADE 7/26/2022 PARCEL ID NUMBER: 018-281-24 /.q�0 0 60 N SCALE: !!Nm - 1.1 = 40' �. rey A. Gayness = ♦ 79 3 %Sz4 it Z:: . LICENSE VA � \\S\� •••• #AECC884 / PERMIT NUMBER: OSP211324 RECORD DRAWING TOP OF TANK AT INTLET = 91.75 TOP OF MH = 96.97 /--- FINAL GRADE = 96.21-96.24 MH ST2 TOP OF TANK AT OUTLET = 91.74 INVERT OF BUNG AT INLET = 91.07-/ \ Doo �-- NEW 1599 GALLON H.D.P.E. GREER SEPTIC TANK RATED FOR 10' BURIAL - NO GROUNDWATER ENCOUNTERED IN TANK HOLE EAST ORIGINAL GRADE ATTO� FINAL GRADE = 96.46-96.78 HIGHEST POINT = 96.44 2022 T.H. FILTER FABRIC INVERT OF PIPE = 90.22 0.52' �5'~I BOTTOM OF TRENCH = 89.70 RELATIVE ELEVATION OF BOTTOM OF T.H. = 79.94 (GROUNDWATER ELEVATION AT 83.44 ON 7/14/22) ORIGINAL GRADE AT HIGHEST POINT = 95.86 0.52' F i PARCEL ID NUMBER: 018-281-24 INVERT OF BUNG AT OUTLET = 90.92 910 WEST FINAL GRADE = 96.56-96.76 2022 T.H. FILTER FABRIC INVERT OF PIPE = 89.63 BOTTOM OF TRENCH = 89.11 RELATIVE ELEVATION OF BOTTOM OF T.H. = 79.36 (GROUNDWATER ELEVATION AT 82.86 ON 7/14/2022) GARNESS ENGINEERING GROUP L FNr:INFFRINr- cAI FC r.r)MCl IITIAIrl ' �� 3/U1 L. I UUUR RUAU, SUI I E 101 - ANCHORAGE, AK 99507 - PHONE (907) 337-6179 • FAX (907) 338-3246' WEBSITE: w .gamessengineertng=m PREPARED FOR: PHONE NUMBER: PAGE NUMBER: PATRICK NELSON 1-509-545-3772 3 OF 3 PROJECT/LEGAL DESCRIPTION: DRAWN BY: WELMAN; LOT 2 D.J.G. TYPE OF WORK: DATE: � SEPTIC SYSTEM PROFILE RECORD DRAWING 7/22/2022 All.'�• .. .. . 0 effr�.y,. Garness .:.cvi 4-10 AN 4E-71953 AV AW LICENSE #AECC884 / a g N N O U) ui N F q rn = ww = N w Pip\uYi o f Z m u F- COw two N LLI > w � F- U i�'j _ q0 z o �a.W } m J N D << 0 > Z_ U U O Q I i J tit\\\\\\\\\\�� = W F 0 g F- = U m F- CO m U Z } _ m I S 00003'19" E 300.09' U)° z° 0 i Wo < Wig N W �C ATL Q IN q }? w ? _¢¢ mq 041: W CIO QCL CL Z F- Y Cl) 0 o fA N 50.1 w am w-' ~ z=� Q� X a� Q _ =O O gE-rn 0q JN 0wo w ��UJ `" Z a mCD Nr oo q w °° z }z oo L pLLcn d W wWW g N 8'8Sp N U) > 0= Cl)Z q U ul Z Z > W E- f- E- Z G A'Z£ int___ Cfl -Lo � 3: Q � o W oeZ�.Y,� _1 ch w rn ,- o0 0LU o W� Z Q o9'OZ ti'6 d w z U-)cwn o m Q Q LL1 d o \ \ l U) 0')Oz w q `t > u� N \co FW �~Q gZ_ = �✓y zq = U) LU F- I vw q,� HE- Wi2 F- _ E- U)D C)w �y do F'rn U)W 0z0 u) Wz w~ LU OU aiu N F- �� cnoo w I I o, oa oU c)Z} LO w0 U)<w Z0~ o Lu O> ADO Z OE LLm ZQcU) t=jcna o0 �z a N 00003'19" W 300.15' j W o al F- Z U U I c~>w `- I �� omw WOm c� I i LU OJ U) �U)w 0wlq- 03 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP211324 Work Type: Septic Upgrade Tax Code Number: 01828124000 Site Legal Address: WELLMAN LT 2 G:3135 Site Mailing Address: 3540 TWILIGHT LN, Anchorage Owner: NELSON PATRICK L Design Engineer: GARNESS ENGINEERING GROUP LTD This permit is for the construction of: Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Effective Date: Expiration Date �r�nt X04 S�, o Department Lot Size in Sq Ft Total Bedrooms: 8/26/2021 8/26/2022 ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing I Special Provisions: 100 ft separation between the proposed septic system and the well on the lot to the east shall be confirmed prior to construction. Received By:(r Date: Issued By: 2 OG 2nt 6'5 Date: $ 2 b ocD 3 '. TYPE OF DWELLING: wG�j;t �1 S1 Li+tA P ar �S ANCHORAGE va �a F y } i u52& 5 ai �`�n aY u :� Y`` : Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Privy ❑ Multiple Dwellings ❑ (SF and/or D) Private Well ❑ Development Senjices Depa! i!-nent �_ - - Phone- 907-343-790 On -Site Water & Wastewater Section Distance: Pax: 907-343-7997 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 018-281-24 Property owner(s) PATRICK NELSON Mailing address 3540 TWILIGHT *ANCHORAGE, AK Site address Legal description (Sub'd., Block & Lot) WELLMAN; LOT 2 Legal description (Township, Range & Section) Lot Size Day phone 509-545-3772 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field 0 Initial ❑ Single Family (SF) x❑ Septic Tank Q Upgrade x❑ (w/wo ADU) Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Privy ❑ Multiple Dwellings ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. Gzvn_,� �- (Signature of property owner or authbzDzed agent) ( �1�---' Permit/Rush Fees: 5q 5 Waiver Fees: Date of Payment: A d2 I Date of Payment: Receipt Number: 0329 (V C-2 Receipt Number: Permit No.OS%�2 1 /l C-1 Waiver No. G:\Development Services\Building Safety\On Site Water and Wastewater\Forms\Client FormsTermit Application.doc Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211324, Rebecca Carroll, 08/26/21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211324, Rebecca Carroll, 08/26/21 DESIGN CRITERIA: NUMBER OF BEDROOMS: 3 GALLONS PER DAY (GPD): 450 PERCOLATION RATE/S: 2.8 MIN/INCH PROPOSED APPLICATION RATE: 1.2 MINIMUM DRAINFIELD SQ.FT.: 375 FT' DRAINFIELD DESIGN: MAXIMUM DEPTH: 6.75 FEET WIDTH: 5 FEET LENGTH: 40 & 40 FEET (80 FEET TOTAL) EFFECTIVE: 0.5 FEET REDUCTION FACTOR: N/A ACTUAL SQ.FT.: 400 FT' CONTRACTOR TO HAVE ALL 100' WELL RADII FLAGGED BY A PLS PRIOR TO CONSTRUCTION GEG, Ltd. HAS AN 8 PAGE SPECIFICATION LETTER THAT PERTAINS TO THIS DESIGN. BY PROCEEDING FORWARD WITH THIS INSTALLATION, THE ENGINEER, WELL DRILLER, CONTRACTOR AND PROPERTY OWNER AGREE THAT THEY HAVE READ THESE SPECIFICATIONS AND AGREE TO ACCEPT THE TERMS AND CONDITIONS OUTLINED. PROPOSED 1000 GALLON HDPE GREER TANK; INSTALL DOUBLE CLEANOUTS BEFORE AND AFTER TANK lZi / / I !j !! I 5'+ FROM TANK APPROXIMATE LOCATION OF EXISTING I TRENCH TO BE ABANDONED IN PLACE L c #1 Q s GARAGE EXISTING HOUSE j 00 �l �O�GN T.H,#\\\ L2' L2 ' A '-11- WELL ON LOT 134: PER THE CONTRACTOR (JASON WITH A+ HOME SERVICES), HE MET WITH THE HOMEOWNER OF LOT 134 AND DETERMINED THAT THE WELL IS LOCATED INSIDE OF A WOODEN BOX (NEAR THE SOUTHWEST CORNER OF THE HOUSE). GEG WAS NOT ABLE TO CONTACT THE HOMEOWNER ON 7/14/22 TO CONFIRM THAT THE WELL IS LOCATED INSIDE THE BOX, HOWEVER, IT WAS CONFIRMED BY GEG THAT THE BOX IS 100'+ FROM THE LOT LINE. IN SHORT, IF THE WELL IS LOCATED WHERE THE HOMEOWNER TOLD THE CONTRACTOR IT WAS LOCATED, THERE ARE NO CONCERNS. 19 DRAINFIELD 1klFkI TA ARNESS ENGINEERING GROUP, Ltd 3701 EASTTUDOR ROTb'19EIOIE'ANCAl2E-,ASLISKAE PtrONE tf-0ij337-61i9i Y. 55 -v,:�w.gzmessengieering.nm :.... ..+ :.. . ......................�. .0 PREPARED FOR: PHONE NUMBER: PAGE NUMBER: f � J ej�+A. Ga ness Q a PATRICK NELSON 509-545-3772 2 OF 2 �# C g -_Ar PROJECT/LEGAL DESCRIPTION: DRAWN BY: •#�� • Qi� Z2 \e" WELLMAN; LOT 2 D.J.G. SIF•••''••• ( �'i TYPE OF WORK: DATE: ♦,111NOi E,SS\ ' DESIGN OF SEPTIC TANK UPGRADE7/14/2022 # ICENea Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211324, Rebecca Carroll, 08/26/21 ELECTRIC PEDESTAL -----TWILIGHT LANE ---------- 0 EAST 164.82' i.. w DRIVEWAY' w'. r� v GARAGE l WELL 41.0' v ' 23.0' 10.0' 07 ATTACHED Cd N 9 5, COVERED SHED DECK 45.9' 24.0' ; - o i SEPTIC rNn CLEANOUT N SHED Z 4.0' ^ 1.5' C) 4.0' M 1 -STORY LOG 0 vN AND FRAME w 616.0' HOUSE —� DECK LOT 1 SEPTIC STANDPIPES w 0 0 LOT 2 49,466 sq, ft. l S 89058'39" W 164.82' LOT 155 0 20' 40' EASEMENTS OF RECORD, OTHER THAN THOSE SHOWN ON THE RECORDED SUBDIVISION PLAT (79-75) ARE NOT SHOWN HEREON. THIS DOCUMENT DOES NOT CONSTITUTE A BOUNDARY SURVEYAND IS SUBJECT TO ANY INACCURACIES THATA SUBSEQUENT BOUNDARY SURVEY MAY DISCLOSE. UNDER NO CIRCUMSTANCES SHOULD ANY OF THE DATA HEREON BE USED FOR CONSTRUCTION OF FENCES, IMPROVEMENTS, OR FOR ESTABLISHING PROPERTY BOUNDARIES. JOB # 21091 NO CORNERS SET THIS DATE I SCALE 1"= 40' 0 N 0 w C = LOT 134 m t CD o CD �E OF A Bfi 7i� JJ •• LS -14837 r��rFPFO 6/302021 QSJQ� AS -BUILT I HEREBY CERTIFY THAT I HAVE SURVEYED THE FOLLOWING DESCRIBED PROPERTY: LOT 2, WELLMAN SUBDIVISION ANCHORAGE RECORDING DISTRICT, ALASKAAND THAT THE IMPROVEMENTS AS DEPICTED HEREON EXIST AS SHOWN IN RELATION TO THE PROPERTY LINES. DATED THIS 3rd DAY OF JUNE, 2021, AT ANCHORAGE, ALASKA. FIXED HEIGHT, LLC C.O.A.122554 Land Surveying Services 907.290.8949 225 W 23rd Ave., Anchorage, AK 99503 WWW.FIXEDHEIGHT.COM %,./ MUNICIPALITY OF ANCHORAGE ,,~./ DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME MAILING ADDRESS LEGAL DESCRIPTION LOCATION _o~ I DISTANCE TO: ]Well Manufacturer HOME~DE t~in gallons I? : Well /.~g) I Length of e~ci~ I~eo~ ~ IAbsorption area Inside length PHONE ~NEW E]UPGRAOB Dwelling Mater'a Total length of lines Material bene~t~hi~le' NO. OF BEDROOMS PERMIT N~.~.~ ~~~,0~,. No, of compartments~.~ Material Nearest lot line Trench wid~ inches Liquid depth Dwelling PERMIT NO. Manufacturer Liquid capacity in gallons Foundation PERMIT NO. '2 DISTANCE TO: No. of lines Top of tile to finish grade Width Total effective absorption area Length Depth ,e of crib Crib diameter Crib depth Total effective absorption area Well Building foundation Nearest lot line DISTANCE TO: Depth Building foundation DISTANCE TO: Driller Sewer line PERMIT NO. Distance to lot line Septic tank OTHER PI PE MATER IA L~).~ . SOILTESTRATING /F~ 2-~0"13 (Rev. 3/78~ (~ DATE LEGAL DEPARTMENT OF HEAL. TH AND ENVIRONMENTAL PROTECTION 825 "L" STREET, ANCHORAGE, RK. 9950-1 ~64-4, ~0 O~I--S I TE '__~E[.]EF-.' PER~ ][ T PERMIT NO. ( ?905:88 ) RF'PLICRNT TED WELLMRN ,...~.-490 E ~RR ~ ~ '-~ LOCATIGN [.ICM N LEGAL TYPE OF SOIL RBSORBTION SYSTEM tS: TRENCH 54450 SQURRE FEET MRNIMUM NUMBER OF BEDROOMS SOIL RATING THE REQUIRED SIZE OF THE SOIL RBSORPTION SYSTEM IS: E'-" E P 'l" H .~- dL:-l- ~__E~GTH: 3~ f3~ R fi"," E L. ~-'E F' T ~ = 7 THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRAINFIELD. THE DEPTH OF A TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE GROUND RND THE BOTTOM OF THE EXCRVRTION (IN FEET). THERE IS NO SET WIDTH FOR TRENCHES. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFRLL PIPE AND THE BOTTOM OF ]'HE E~CAVRTION (IN FEET). F-: E r_-.. IJ I RED SEPT I C: TF-II'-tI~-:] S I ZE= .-1~_ O,L:~ E-! GF~LL~]~-t~ ;PERMIT RPPLICRNT HRS THE RESPONSIBILITY TO INFORM THIS DEPRRTMENT DURING THE INSTALLATION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY RND THE NUMBER OF RESIDENCES THAT THE WELL WILL SERVE. ]-b~C~ (2) I ~SF'ECTIO~S RE:E REC~LII E:E[:. BRCKFILLING OF ANY SYSTEM WITHOUT FINRL INSPECTION RND RPPROVRL BY THIS DEPRRTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCE BETWEEN R WELL RND RNY ON-SITE SEWRGE DtSPOSRL SYSTEM IS 100 FEET FOR A PRIVATE WELL; OR i50 TO 200 FEET FROM 8 PUBLIC WELL DEPENDING L~'ON THE TYPE OF PUBLIC WELL. OTHER REQUIREMENTS MBY APPLY. SPECIFICATIONS 8ND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER INSTALLATION. F'ERI"I I T E.S'-~ F' I RES DE~CEIF-'IBER I CERTIFY THAT i: IRM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS RS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE. 2: t WILL INSTALL THE SYSTEM IN RCCORDBNCE WITH THE CODES. 3: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENL, RRGEMENT IF THE SIGNED: ...... ;:; ..................... APPLICANT TEE) WELU1RN ..... ......... Perfformed for ,t Le_oal Descnpt~or This form reports: Depth Feet 3- 4- 5- 6- 7-- 8-- 12'--' 14-- '18- GR¢..rER ANCHORAGE AREA BOROUCk~ Dep~nrr;ent of Environmental Ou~liw ' · ' 3330 "C" Street ,' sOiLs LOB-- Soils log .~ , Percolation Was groundwater encountered? ''I .............. ,4,:,%, ~'"'~'~//~ ~ yes, at what depth? ; I Reading Date Performed . D~te ' Gro~ Time t Net Time I Depth to Water ~H;Iqt '/:5~ ¢/~ t 0 ~ o.q/ / ' '1 ~:~ ~5 ~ ~.1' f I ?. 4~ i//5 ~ ~ .~- , ~ t,x , ,,I ,,,/4 I rercolation r~te ' ""'~/" ~ : Proposed.installation: ~:.~age Pit . -- Drain Field Depth of Inlet , ~ '~--f' ,/ ,... DeRth~to.b?ttom of pit or tI%nc~h' -- COMMENTS: /~¢¢'¢'~// I0 ~,~//~¢x.~ ~ , /~ ~ ....... ~ ~,.. ~m ~11~ ~mi~i~R~. ~ . _ Date: LOCATION ..... ~-Ir'ALIT ' ¥ Or- aNCHoRAGp~ FOSS DRILLING 8F_,p 13~6 I~ra Street . ~l t~,,,~ 1 USE OF~' SIZE OF CA~ING b"' DEPTH OF HOLE/_~PT. CASED TO / -~ 2 FEET OF DRAWDOWN. REMARKS DATE COMPLETED PUMP TO BE SET AT AA Ve /~t~/~ . q~ ~ __t o ' __t~__ __t6 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION DIVISION OF ENVIRONMENTAL HEALTH CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SiTE SEWER AND WATER FACILITY 264-4720 Application Date GENERAL INFORMATION (a) Legal Description (include lot, block, subdivision, section, township, range) Location (address or directions) (b) Applicant Name ~ II~ ~1~-3 Telephone: Home ~- tqm7 Business ~qff' '7~/~ Applicant Address ~YO ~, lt~h~ ~, ~4c~or~ / (c) Applicant is (check one): Lending Institution ~; Owner/builder ~; Buyer ~; Other ~ (explain); Real Estate Company and Agent Address Telephone (f) Mail the HAA to the following address: TYPE OF RESIDENCE Single-.Family~ Multi-Family[] Number of Bedrooms .¢*~ Other WATER SUPPLY Individual Well I~ Community [] Public [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. SEWAGE DISPOSAL' Onsite [] Public [] Community [] Holding Tank [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 72~025 (11/84) Page I of 2 ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm r~'{cz ~,/~ 7~c ,~ ~ ~'c,~f ~'~,~-¢~,(',:~' Telephone Address I~'tb'-.?O ~-cA~ 5"~,..,., ,,~'ncl~rc~L/q~? ]t-~ Date c~',z ,~ ! / 8(' ~pp:;:::~ ,or~¢__------t~ Disapprov~dd . . Condition,~// Terms of Conditional Approval CAUTION 'The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 72-025 (! 1/84) MUNICIPALITY OF ANCHORAGE (MOA) HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST- FEBRUARY 1984 264-4720 Legal Description: A. WELL DATA Y Cased to ~ 6'~' If A, B, C, D.E.C. Approved (Y/N) ~ ,~'. Date Completed ~.lh~l 7/ Yield Depth of Grouting Pump Set At _~. '~S" Sanitary Seal on Casing (Y/N) Y Depression Around Wellhead (Y/N) Well Classification Well Log Present (Y/N) Total Depth [~£1 Static Water Level 7~' Casing Height Above Ground Electrical Wiring in Conduit (Y/N) Separation Distances from Well: N To Septic/Holding Tank on Lot Ill' ¢-~ ¢'. c,. ; On Adjoining Lots ~. too ' To Nearest Edge of Absorption Field on Lot ~' I ~5' ' ; On Adjoining Lots '~ coo ' To Nearest Public Sewer Line ~,/J. To Nearest Public Sewer Cleanout/Manhole N, 4. To Nearest Sewer Service Line on Lot N,,4. Water Sample Collected by "T'~ ,~/ ; Date Water Sample Test Results Comments C -J-~ c~/ ~ c~ m,~, ~,' ,8' / ,'5' B. SEPTIC/HOLDING TANK DATA Date Installed "7/E-¥/7,~ Size Standpipes (Y/N) Depression over Tank (Y/N) Pumping/Maintenance Contract on File (Y/N) Holding Tank High-Water Alarm (Y/N) Separation Distances from Septic/Holding Tank: TO Water-Supply Well I! I ~ ~o~ ¢, ~', To Property Line ~, ~o ' To Water Main/Service Line Course ~> I No. of Compartments ~-- Air-tight Caps (Y/N) ~' Foundation Cleanout (Y/N) N Date Last Pumped ~/'[¢'/~9'(¢ ; for N,~. Temporary Holding Tank Permit (Y/N) To Building Foundation '~0 ' To Disposal Field ~c¢- d~'/'a~ce' ~,:/- ..¢Ao,,.,,~ o~ To Stream, Pond, Lake, or Major Drainage Comments H~z~,y ..Cecum [~,~r ~adtc~/~c.( Page 1 of 2 72-026(11/84) C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata Date Installed Width of Field ~6" Square Feet of Absorption Area 5-q~ Depression over Field (Y/N) N Results of Last Adequacy Test /'~¢,¢~a ~¢ Separation Distance from Absorption Field: To Water-Supply Well To Building Foundation Lot ~ +70 ' To Water Main/Service Line To Stream/Pond/Lake/or Major Drainage Course To Driveway, Parking Area, or Vehicle Storage Area Comments .~'~ ~t '~ ~2{c¢~ (,~c~.( Type of System Design Length of Field ~¢ / Depth of Field Il* - I'~.~ Gravel Bed Thickness '7 ¢ Standpipes Present (Y/N) Date of Last Adequacy Test To Property Line ~ lO ' To Existing or Abandoned System on ; On Adjoining Lots ~ -~ / To Cutbank (if present) ~I,A. D. LIFT STATION ~h ,'~, Date Installed Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for Electrical Codes (Y/N) Dimensions Manhole/Access (Y/N) "Pump Off" Level at Vent (Y/N) Pumping Cycles during Adequacy Test. Meets MOA Comments ** Check Permitted Bedroom Rating Against HAA Request ** I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. Date MOA No. Signed ~~ Company Receipt No. Date of Payment Amount: $ '~'~,'b%~ Page 2 of 2 72-026 (11/84) Engineer's Seal '~UNICIPALITY OF ANCHORAGE MUNICIPALITY OF ANCHORAGE DEPT. O? }!:Ai. TH & DEPARTMENT OF HEALTH IA ENVIRONMENTAL PROTEC[~i,~ONMF. NTAL ,r, kOTECT[ON 825 L Street JAnchorage, Alaska 99501 JUN 1 ENVIRONMENTAL ENGINEERING DIVISION Telephone 264-4720 FIEQUEST FOB APP.OVAL OF INDIVIDUAL WATER AND SE~ FA~L~/T~) DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed~ Please allow ten (10) days for processing. MAI L~ING ADDRESS PROPERTY RESIDENT (If different from above) 2. BUYER ~AI LI N~ ADDR ESS 3. L lNG INSTITUTION MAILING ADDRESS PHONE PHONE 5, LEGAL DESCRIP ON ~ , TREET LOCATION 6. TYPE OF RESIDENCE ~.~..~ /NUMBER OF BE~OOMS · ~ ~ One ~ Four ~ Other ~ SINGLE FAMILY ~> /~ Two ~ F,ve ~ MULTIPLE FAMILY ~ Three ~ Six 7. WATER SUPPLY ~ INDIVI DUAL* * ATTACH WELL LOG. A well (o§ is required for all wells drille"~--~' [] COMMUNITY since June 1975. For wells drilled prior to that date, give well [] PUBLIC UTI LITY depth (attach log if availab)e,) **If individual/on-site, give installation date If system is over two (2) years old an adequacy test is required by this Department. 8. SEWAGE DISPOSAL SYSTEM '~--I N DI VI DUA L/ON-SITE~ [] PUBLIC UTILITY NOTE THE INSPECTION_FEE MUST ACCOMPANY. ~~.~ORE PROCESSING. CAN BE INITIATED. .2:30 THIS SIDE FOR OFFICIAL USE ONLY DATE RECEIVED INSPECTION APPOINTMENTS TIME TIME TIME DATE DATE DATE I NSP ECTOR I NSP ECTOR INSPECTOR DIRECTIONS: 1. TYPE OF RESIDENCE · NUMBER OF BEDROOMS ~ SINGLE FAMILY [] ONE ""EZ] THREE [] FIVE [~] OTHER [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMBER 2. WATER SUPPLY -~C'~ ~] INDIVIDUAL DEPTH OF WELL ~ COMMUNITY DATE DRILLED Conn'ection Verified LOG RECEIVED PERMIT NUMBER 3. SEWAGE DISPOSAL SYSTEM ~O[ ~ INDIVIDUAL/ON -SITE DATE INSTALLED ~PUBLIC UTILITY ~-~ Connection Verified ~N~TALL~ ~Septic Tank or ~ Holding Tank ~ ~ ~j~_ Size:/~(~ . If Tank is homemade SOILS,RATING give dimensions: ~ ~ . TOTAL ABSORPTION AREA ~RI~L 4. DISTANCES ~ Septic/Holding Tank Absorption Area Sewer Line [ Nearest Lot Line I WELL TO: Absorption Area to nearest Lot Line ~ CO~DITIO~A~ A~PBOVAL {letter must ack,pang cortificato} ~ DISAPPROVED DATE ~ ~ ~t ~ BY(Title) LEGAL DESCRIPTION 72-010 (Rev. 3/78) BASIS OF REARINGS EAST (ISI9.01' REC.) (lll, B.SB' ACCEPTANCE OF DEDICATION LEGEND ~URVEYOR'S CERTIFICATE VICINITY MAP SCALE , MILE CERTIFICATE OF OWNERSHIP & DEDICATIOI~ I(WEi, HEREBY CERTIFY THAT I AM (WE ARE) THE OW#ER{S) OF THE NOTARY' ACKNOWLEDGEMENT LOTS I G 2 BLN LOT 1:55 BOMHOFF & ASSOCIATES, INC. Engineering' Planning' Surveying 102OWES1 INTERNATIONAL AIRPORT ROAD ANCHORAGE A L ASK A