HomeMy WebLinkAboutGARRETSON LT 6Onsite File #017-432-43 Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904 Page of ON-SITE WASTEWATER INSPECTION REPORT Permit Number: 191460 PID Number: 017-432-43 Dwelling: ❑ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ❑ Upgrade Name Stanley & Darlene Dunagan ABSORPTION FIELD ❑ Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound Site Address 7131 North Park Drive Anchorage, AK 99516 ❑ Other Phonef Bedrooms Soil Rating depth from original grade (907) 272-8463 777 4 Existing GPD/SF JTotal Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Ft. Gravel depth beneath pipe Ft. Subdivision Block Lot Garretson 6 Fill added above original grade Ft. Gravel length Ft. Township Range Section Gravel width Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line Ft2 Ft. Well >100' N/A N/A N/A NA TANK 9 Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Greer Capacity 1,250 Surface Water > 100' N/A N/A N/A Material Number of compartmentsGal. Lot Line >5' N/A N/A N/A NA Plastic 2 Foundation >10' N/A N/A N/A LIFT STATION Manufacturer Capacity Remarks Tank only permit. Gal. Alarm location Electrical installed by PIPE MATERIAL House to tank D3034 Tank to drainfield D3034 Installer A+ Home Services Drainfield N/A CO/MT D3034 Inspector J. Williams BENCH MARK (Assumed elevation) 100 ft Inspection 15' 12/16/19 Location and description 2 nd Bottom of siding. 3rd 4m ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp OF '° '° q X404 Conditional Approval: Date®�P�°'°°° � �°• 49th i 7V ®..........uu.....uu..........u.......�..... �®� ;°MICHAEL E. ANDERSON d 0 f No. CE -4381 .�•Z IN X04, Septic System Approved Date 3 a7 =40 p* %. 3/24/20.°••°�<&4 Note: this approval does not include well permit requirements. 4p 4t10R0FESSIQNP� pRO ®®� (K@v UD/UL/l ZS) 100500 FEET 1"=50' 4-BDRM HOME CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND 2CO MH1 PERMIT # OSP191460 PID #017-432-43 GARRETSON, LOT 6 A B MH1 50.6 SV1 54.05 2CO 53.2 AB 27.8 31.2 37.7 NORTH PARK DRIVE 3/25/20 EXISTING WELL DECOMMISSIONED EXISTING SEPTIC TANK IN PLACE PER M.O.A. CODE. EXISTING ABSORPTION TRENCHES. FENCE NEW 1,250 GALLON SEPTIC TANK w/20" MANWAY SV1 CONNECTED TO EXISTING FLOW DIVERTER VALVE EXISTING ABSORPTION TRENCH. PLAN AS-BUILT 100' WELL RADIUS SHEDS SHED PROFILE AS-BUILT (NO SCALE) PERMIT # OSP191460 PID # 017-432-43 GARRETSON, LOT 6 3/25/20 92.85 87.9 93.4 99.2FCOMH1 SV11250 GAL PLASTIC SEPTIC TANK 2CO92.65 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http-1/www-muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP191460 Work Type: SepticTank Upgrade Tax Code Number: 01743243000 Site Legal. Address: GARRETSON LT 6 G:2839 Site Mailing Address: 7131 NORTHPARK DR, Anchorage Owner: DUNAGAN STANLEY D & DARLENE E Design Engineer: FORGE ENGINEERING This permit is for the construction of: O Disposal Field 9 Septic Tank ❑ Holding Tank ❑ Privy Effective Hate Expiration Date: Lot Size in Sq Ft �,„ent g . f� Department 10/14/2019 10/13/2020 49419 Total Bedrooms: 4 ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (2417). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either. a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing t . % Date: /,` ; Received By: Issued By: /t Date: �4Z4 9 PINUPS MUNICIPALITY OF ANCHORAGE Community Development Department `.s Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 017-432-43 Property owner(s) Stanley & Darlene Dunagan Day phone 272-8463 Mailina address 7131 North Park Drive Anchorage, AK 99516 Site address Same Legal description (Sub'd., Block & Lot) Garretson, Lot 6 Legal description (Township, Range & Section) Lot Size 49,419 Sq. Ft. Number of Bedrooms Four (4) APPLICATION IS FOR: (® all that apply) Absorption Field ❑ Septic Tank ❑X Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage ❑ APPLICATION IS AN: TYPE OF DWELLING: Initial ❑ Single Family (SF) ❑X (w/wo ADU) Upgrade 0 Duplex (D) ❑ Renewal ElDuplex Dwellings ❑ (SF and/or D) THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: 9 -26 - Date of Payment: lol q 1 ig Receipt Number: 06ASCID Permit No. 06 PI q l t4bb Permit App_:- : .'-.:c Waiver Fees: Date of Payment: Receipt Number: Waiver No. PO BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) October 9, 2019 MOA Development Services Department On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Garretson, Lot 6 – 7131 North Park Drive Septic System Design Dear On-Site Services Engineer: The septic tank on the subject lot has failed and must be replaced. We are submitting this design and permit application for the construction and placement of a new 1,250-gallon septic tank. The attached site plan identifies the location of the home and the septic system along with the new tank location. The existing well on the lot is also shown. No conflicts exist between this proposed tank and any other well or septic system on this or adjacent lots. The new tank will be constructed a minimum of 100’ from any existing wells. It will also be 100’ from surface water and more than 5’ from the existing absorption trench. The new tank will be 10’ from the house foundation and more than 5’ from any deck or stair supports. Please refer to the attached plan sheet for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Michael E. Anderson, P.E. 10/9/19 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP191460, Rebecca Carroll, 10/14/19 10050 0 FEET 1"=50' 4-BDRM HOME NOTE: NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC SYSTEMS. CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND MH GARRETSON, LOT 6 NORTH PARK DRIVE 10/7/19 EXISTING WELL DECOMMISSION EXISTING SEPTIC TANK PER M.O.A. CODE. EXISTING ABSORPTION TRENCHES. FENCE 1,250 GALLON SEPTIC TANK w/20" MANWAY SV 2COFD CONNECT TO EXISTING FLOW DIVERTER VALVE EXISTING ABSORPTION TRENCH. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP191460, Rebecca Carroll, 10/14/19 Municipality of Anchorage Page l of DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: ~0~/~ PID Number: ~::~ / ? "/ 71~I N, P~r~ Dr. No of Bedrooms Phooe 3 'Cb" - o ~o ¢ LEGAL DESCRIPTION Wastewater System: [] New [~ Upgrade ABSORPTION FIELD Deep Trench -- Shallow Trench ~ Bed ~ Mound Z Other O, ~'- GPD'Sq Ft Total Depth from original grade Gravel depth beneath pipe I, 0 ' Ft WELL: (e~,sr,~-~ New Upgrade Class,ficabon IPriva!e A.BC! Driller Tolal Depth Cased To Fi Stat,c Ft Date Drilled '¢,'aler LC,el Ft GPM Ft Ft SEPARATION DISTANCES Gravel length: F~lil dbsorptJun area J Pipe materiah Date installed: IO/~/?~ TANK Septic ~ Holding _~ S.T.E.P Manufacturer Material Capacity in gallons: I Number of Compartments LIFT STATION N. 4. BENCH MARK Inspections performed by: Department of Health and Human Services approval // I0o. oO ENGINE£R'$ $£AL P. ermit I~o. ? ?-- o .~ I ~ Page '~ of 3 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Legal Description: I,.~¢' ~'/ ~-~xr'r ¢'f..~o,q ~ / lb PID No.: 72-0~3 A (2/91} MOA25 I  I',IORTH ?AR~. J)RII/P-- FRO'f"l: CON VA" ¢oR *~" WEST 7~ ~3' ,Flattop Technical Services 14530 Echo Street Anchorage, Alaska 99516 i ENGINEER'S SEAL ....... , THEODOR2 F. ~OORE Permitl{Io. ~F__O3 !~ Page Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Legal Description: PID No.: ' 017¥ lO0~ -- 72-013 A (2/91) MOA 25 I'~, 1'; OR¥ l:']attop Technica! Ser~ 14530 Echo Street Anchorage, Alaska 9! 516 ENGINEER'S SEAL :es CIVIL & ENVIRONMENTAL ENGINEERING · ENERGY CONSERVATION & ANALYSIS THEODORE F. MOORE, P.E. 14530 ECHO ST. PH: (907) 345-1355 June 21, 1993 ANCHORAGE, ALASKA 99516 Dan Roth M.O.A. DHHS P.O. Box 19-6650 Anchorage, AK 99519 Dear Mr. Roth: RECEIVED JUN 2 3 1993 Mumc~pal~ty ot Anchorage Dept. Health & Human Services Dan Bolles asked that I return the enclosed "pink sheet" to you regarding the new wastewater disposal system installed last October on Lot 6 of Garretson S/D. Apparently he had inspected the installation in late April or early May and found water in the old monitor tube for our test hole #10 and was concerned about a possible shallow water table. As noted on the pink sheet we reinspected the system on June 17, at which time the test hole monitor robe was dry, as was the monitor tube in the lower trench and the surface water diversion ditch. My interpretation of these findings is that the water observed by Mr. Bolles was not groundwater, but instead was attributable to the large collecting area of the depression around the test hole concentrating meltwater from a relatively large area down into the poorly permeable softs at the bottom of the test holes where it could only slowly percolate away. I discussed these findings and our interpretation with Dan Bolles, and he indicated that DHHS would now approve the installation. The final surface grading work is now in the process of being completed. Please give me a call if you have any further questions on this installation. Sincerely, Ted Moore, P.E. .~o, ~Z O 3 I~ Page Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report LegalDescription: /-~{' ~'~ ~z~rr ~'£o,~ _~1~ PIDNo.: 0/'7¥ :~2~'...~ ~7t . TR EN CH 12,5'o $.T. _ ~ I~JORTH P.~AR(-:. ,/ Flattop TechnicaI Services 14530 Echo Street Anchorage, Alaskcz 99516 ENGINEER'S SEAL ..... ;....~...', ~., .. ... ~.aT '7 INO~ 0 0 f~ LoT ~ NORT. R PARK DR\YE ~']~[oP Technica! Sez~ce~ 14530 Echo Street Anchorac2e, Alaska 9951~ £o'T TEST Fo d;ARR ET5o N BOLE LOCATION SiTE PLAN SCAL~. : i "= ,~0 DAT.:: NoT~: THI& I$ HOT A 5u~.vE"/ED PL,qT. ALL LocATIoNg PAGE 1 OF 1 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT PERMIT NUMBER:SW920318 DESIGN ENGINEER:FLATTOP TECHNICAL SERVICES OWNER NAME:BAILEY RANDY ERROL & OWNER ADDRESS:7131 NORTH PARK DR ANCHORAGE, ALASKA 99516 PARCEL ID:01743243 DATE ISSUED: 9/30/92 EXPIRATION DATE: 9/30/93 LEGAL DESCRIPTION: GARRETSON LT 6 LOT SIZE: 49500 (SQ. FT.) NUMBER OF BEDROOMS: 4 THIS PERMIT: 4 THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS RECEIVED BY: ~T~ DATE: ~ / ~' /~ ~ DATE: ?- 3 o- FLATTOP TECHNICAL SERVICES CI~,2L & ENVIRONMENTAL ENGINEERENG · ENERGY CONSERVATION & ANALYSIS THEODORE F. MOORE, P.E. 14530 ECHO ST. PH: (907) 345-1355 September 21, 1992 ANCHORAGE, ALASKA 99516 M.O.A. DHHS Attn: Dan Roth or John Smith P.O. Box 19-6650 Anchorage, AK 99519 Dear Sirs: This submittal is a follow-up to our discussions on September 15. The purpose of this letter is to provide the required design narrative in support of our application for a petnfit to upgrade the wastewater disposal facilities for the 4 bedroom residence on Lot 6 of Garretson S/D, located at 7131 North Park Drive. Soils logs, perc test results, a site plan, design drawings and specifications are enclosed for your review. The existing soil absorption system was installed in 1981 and consists of a 1250 gallon septic tank followed by 75 lineal feet of soil absorption trench containing 6 feet of sewer gravel. The soils test conducted prior to construction reported a measured percolation rate of 20 minutes/inch. The system was sized on the basis of 225 square feet per bedroom. After a number of years of problem-free operation, the system is now in a state of failure, requiring periodic pumping to prevent sewage from backing up into the house. During August and September of this year we dug 10 test holes on the lot in an effort to determine the optimum site for a replacement system. The predominant soil type on this lot is a dense gray gravelly silt. · While several of the test holes showed pockets and/or thin veins of sand and gravel, we were unable to identify a large enough contiguous area of granular material to design an upgrade in it. Three different perc tests conducted in the silt all demonstrated percolation rates in excess of 60 minutes per inch. After discussions with Dan Roth and John Smith @DHHS on September 15, we concluded that the only practical alternative to a holding tank is to install a series of oversized soil absorption trenches. Since the property owner does not need a HAA certificate at this time, it will be possible for an adequacy test to be conducted after the trench upgrade has been in service for at least one year prior to issuance of a HAA certificate. The logs for test holes 7, 9 and 10 are most applicable to the proposed upgrade trenches. Test hole g9 was dug just before several days of min. The initial perc test showed an absorption rate of just under 60 minutes per inch in the pre-soak phase with 12" of water in the perc hole. On September 8 a significantly slower perc rate was measured due to the fact that the entire bottom of the perc test pit had been saturated by recent heavy rains. On September 10 the perc hole was dug out deeper and a perc rate of 320 minutes per inch was measured. We feel this perc rate is still on the conservative side, both because it was conducted in soils which had been over-saturated, and because it ignores the contribution of the scattered sand seams which constitute an estimated 5 - 10 % of the sidewall area~ The monitor tubes in each of these test holes were dry on 9/17/92, indicating that there is not a shallow groundwater table problem. To develop appropriate sizing criteria for this upgrade, we extrapolated from the required absorption areas in the 1986 and 1990 versions of the wastewater ordinance corresponding to different measured perc rates. From the an examination of the relationship between perc rates and required absorption areas for a range of perc rates, we noted that doubling the measured perc rate results in a 33% increase in the required absorption area, and tripling the perc rate causes a 50% increase in the absorption area. Thus, we calculated that doubling the 60 min/in perc rate to 120 min/in, and then tripling that to 360 min/'m would, dictate a doubling of the required area corresponding to 60 minfm soils. Since we measured a perc rate of 320 min/in, we have sized the upgrade on the basis of 0.45/2 = 0.225 gpd/sq, ft. The required absorption area for this 4 bedroom residence thus becomes (4 x 150)/0.225 = 2667 square feet. Using a gravel depth of 7' below the horizontal distribution pipe, the required trench length is 2667/(2 x 7) = 191 lineal feet. The proposed upgrade design achieves this with 2 parallel trenches of 105' and 86' lengths spaced a minimum of 20 feet apart. This sizing criteria does not count the contribution of the scattered sand seams which were noted in several of the test holes. By virtue of the trenches extending so far across the lot. the system should maximize the interception of these sand seams. Since the measured perc rate is so slow, it is particularly important to minimize any extra water coming into the trenches from surface runoff, particularly during breakup. To accomplish this, an existing surface drainage swale, which the property owner constructed last year, will be re-routed and extended around the north end of the trenches. Even though this swale did not carry any discemable surface flow this year, it's creation is viewed as added insurance. The topography of the lot in the vicinity of the proposed trenches slopes towards the west at approximately 10%. The proposed project will have no significant impact on present or future water supply and wastewater disposal systems serving adjacent properties, nor will it have any impact on reserved space/surface and subsurface, or on areawide drainage concerns. Please give me a call at 345-1355 if you have any questions on this submittal. Sincerely, Ted Moore, P.E. UI,.IDE~I6, NATE b LoT '7100 FluFFPI4N R~ k,'iTt.~ I~ 10o' OF PROP. C..ER LOT -/ t ~ £ PTi C. LoT I E~IST~,G · (D~3 - OF 51.v'A LE l.t- Bt:,R M t4OU<;E ~,~ELL LOT 2 LoT 5' ~ NgR."r,~ PAR~ DR~VE Flattop Technical Services 14530 Echo Street ' ~.~- ~': ........ ..'~ LOT (:, GAR~ET$ON SEPTIC. S"/STE~ UPGRADE SITE PLAN SCALE: [u,_50~ DA't E,: ~J/~12 NOTt=: THinS IS NoT' A SURVE'~ Eb J~LL LOCATIONS <A c.o.% A q" pERF. pIPE' ~" NON - PE F-glO FRo~ ~EPTIC C'LE,~N Oo 1' FlcrUop Technical Services ~4530 Echo Street Anchorage, Alaska 9951R ~ O~..~.~%.. .,,2'. ~,~ ..... ~" ~,~~......:~.~ SECT I 0 N I"= 5' 1o% ~ FU.-r~'~ - I FABRIC., ~' T LOT ~ 6ARRETSON SOIL ABSORPTION 'TI~ENC FLAN ~-CROSS $[CT~ON 5CAI_E: AS SHowN Flattop Techn~al Serv~s 14530 Echo Street, Anchorage, AK99516 Phone (907) 345-1355 Lot 6 Garretson S/D 7131 North Park Drive Wastewater disposal system installation Specifications 1.0 General: 1.1 The scope of the project consists of upgrading the existing system by the addition of 191 lineal feet of 12' deep soil absorption trenches containing a total of 7.5 feet of sewer gravel. Access to the construction site shall be achieved by partially f'dling the southern end of the existing drainage swale along the east boundary of the lot to allow vehicular access. After the job is complete this portion of the swale shall be reconstructed to it's original configuration. 1.2 Construction shall be as depicted on the approved site plan and design drawings. Minor deviations from these drawings may be allowed or required by the engineer conducting the inspections. All construction procedures and material specifications shall conform with Municipal and State requirements. All separation distances shall be in conformance with Municipal requirements, unless specifically waived. 1.3 The contractor shall be responsible to obtain any necessary utility locates, and to work around any buried utilities. 1.4 The contractor shall provide adequate cover material and rough grading over all system components to ensure that proper drainage is achieved after settlement and that there are no residual depressions. Insofar as possible the contractor shall minimize damage to trees and existing lawn areas. 1.5 Unless specifically agreed otherwise, the homeowner shall be responsible for f'mish grading after the soil is compacted, as well as placement of topsoil and reseeding all areas disturbed by the construction. 2.0 Existing septic system: 2.1 The existing septic tank may be retained in service provided it appears structurally sound at the time of connection of the new soil absorption trenches. 2.2 The existing soil absorption trench shall be retained in service with the connection piping configured to favor initial distribution to the original trench. 3.0 New soil absorption system: 3.1 The upgrade to the soil absorption system shall be constructed by excavating a total of 191 lineal feet of soil absorption trenches in 2 segments of 105' and 86' each. The trenches shall be aligned roughly parallel to the surface contours of the land. The depth from original ground surface to the bottom of the excavation shall not exceed 12', and where it is feasible to follow a lower surface elevation contour the total depth may be reduced to 10'. 3.2 The bottom of the excavation of each trench shall be level. To minimize the total amount of sewer gravel required, the width of the trench may be as narrow as is practical to work in, down to a minimum width of 12". Compacted or smeared surfaces should be raked to promote optimum infiltration. 3.3 A total of 7.5 feet of approved sewer gravel shall be placed in the bottom of the excavation with the perforated distribution pipes laid level such that the pipe inverts are no less than 7.0 feet above the bottom of the sewer gravel. Sewer gravel shall be 0.5" - 2.5" screened gravel, with less than 3% passing the #200 sieve. 3.4 Monitor tubes and cleanout pipes shall be of 4" diameter and installed in the locations shown on the design drawings. The portion of the monitor tube extending through the sewer gravel shall be perforated. The 4" (ASTM D-3034) pipe linking the 2 u'enches shall incorporate a 4" high "bump" to ensure serial distribution of effluent to the eastern trench first. 3.5 Approved filter fabric shall be placed over the entire top surface of the sewer gravel. If the soil cover thickness is less than 3 feet, two inches of rigid, burial type insulation is to be placed over the entire top surface of the gravel, in addition to the filter fabric. 3.6 The top surface of the cover material shall be raised a minimum of 12 inches higher than the surrounding terrain to allow for subsequent settlement, and shall be graded to smooth contours. Fill slopes shall be no steeper than 3:1. 3.7 The existing dry surface drainage swale, which has a depth of 2' - 3', shall be extended around the north end of the new trenches maintaining a constant downwards slope. The edge of the swale shall be no closer than 15 feet from any portion of the trenches, and it shall taper out to natural ground level near the west property line. This swale work shall be done after the trenches have been constamcted. 3.8 All areas disturbed by the construction shall be covered with 4 inches of topsoil and seeded to promote rapid revegetation. This work shall be the responsibility of the property owner. 4.0 Inspections: 4.1 A minimum of 4 engineering inspections will be required during the course of the project: (1) initial stakeout with the contractor to establish the location of the system and to discuss the plans, specifcafions and construction procedures, (2) after the native material has been excavated to expose the infdlrative surface to ensure that it is level and at the right elevation, and conforms with the soil test infom~ation, (3) after the sewer gravel is in place and the distribution pipes have been laid and connected up to the septic tank, but prior to placement of insulation or filter fabric, and (4) after final backfill and rough grading is complete. 4.2 The instailer shall coordinate the tinting of the inspections with the engineer sufficiently far in advance to ensure the availability of the engineer. '7 140~ I,'VE LL ~ FlattoP Technical Services 14530 Echo Street Anchorage, Alaska 995] ~ LoT TE ST ~o ~ARRET£ON BOLE LOCATION StTE PLAN $C AL'.C: = NOTE'. "l"Ht& I$ HoT A SuI~VE'fED VLAT. ~tLL LoCA'r IOH & i~I&HS~; Tdch'n}c~l 14530 Echo Street *~fic~orage, ~l~sk¢ 99518 MunicJpalJ~y of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L' Street, Anchorage, Alaska 99502-0650 SOILS LOG ~ PERCOLATION TEST ~. ~/ PERFORMED FOR;, RANDY LEGAL DESCRIPTION'. J.,-OT ~ B/ilL£y GARRETSoH Township, Range, Section: SEC 2(o., T SLOPE SITE PLAN 1 2 3 4 5 F$ 6 7 8 9 10 11 12 13 14 15 16 17 19, 20- t"lL SILT WAS GROUND WATER ENCOUNTERED? DEPTH? Monitoring? t~_,~ Dr'~, Date: Reading Date Gross Net I Depth to Net I Time Time Water Drop AT ~EST E~ . ~ 11:29 2 ~Ry OF TE~T ~oLE DRY ~ TH~N ~ ~IN ~T~ ~ H~O F~LO~ ~oPPE~. PERCOLATION RATE ~ I (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN ~.~ FTAND . ~-~ FT COMMENTS ~~lg~ ~JTE ~~l~ TIE PER~ORMEDBY: FZA~OP TEc~. ~vcS. I ~~ CERTIFY THAT THIS TEST WAS PERFORMED iN ACCORDANCE WITH ALL STA%E AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 72-008 (Rev, 4/85) PERFORMED FOR:,.. LEGAL DESCRIPTION: 2 3 HL 4 5 6 5P 7 8 9 ~o ~.H. 11 12 13 14 15 16 17 16 19 20 14530 Echo S[reet Afichorage, Alaska 99516 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST T.H. ~2 RANDy LoT ~, B4~LE¥ GRAV[LL"I SILT' FINE SANb (HOIST") G1~AVELLY SANDY TffAN T.I~. 1~b SILT WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? Oeplh to Waler After Monitoring? Date: Reading Date Township, Range, Section: SEC 2G , T 12/,[~ R 3~'' ' SLOPE SITE ~LAN Net Time Depth to Water Net Drop PERCOLATION RATE __ (minutes/inch) PERC HOLE DiAMETER . TEST RUN BETWEEN __ FTAND . FT COMMENTS ,SEE ,,~¢Cot~pAN',ll/,IG SITE ~LAN F'olP ~'~'~(~ "rtE5 / TEK'r RoLE t~r, fl,T: ,~..( ~'~1( ¢~.,( ' ' PER/5ORMED ev: FLATTOP "FECfl. ~;vc$. ' ,~'T° ~ ~ CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STA';I'E AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. CATE: 72-008 (Rev. 4/85) PERFORMED FOR: LEGAL DESCRIPTION: PT 1 2 3 I~L 5 6 7 8 iO 11 12 13 14 15 16 17 '19 2O 14530 Echo Street A:~chorage, Alaska 99516 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST T. 14. ~3 RANDY B4~L£y ~E~D ]Sh~ No 5Aflb EASIER T.N. v, ~ SLOPE I~..-,~, .............. :...~ I D~TE PE~F'O~iE~:.,. Township, Range, Section: SEC WAS GROUND WATER ENCOUNTERED? N IF YES, AT WHAT DE >TH? Oepth to Water Alter Moniloring? Oalc: Reading Date Gross Time SITE PLAN (DeS © Net Time Depth to Water PERCOLATION RATE -- (m~nutes,dnch) PERC HOLE DIAMETER TEST RUN BETWEEN ~ FTAND __ FT COMMENTS .~gg t~CCo~p~I~"{II, IG SITE '~AN F'o~ ~,~'l,~l~ 'l'lg~ ,/-rE~T ~oLE LO¢,ATI~)I,/_~ . Net Drop PER(rORMEDBY: .F'/-ATToP "FEcH. ~L/CS. I '~"~'-e,~"~-~... CERTIFY THAT THIS TEST WAS PERFORMED iN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 72-008 (Rev. 4/85) PERFORMED FOR: LEGAL DESCRIPTION: p'F 2 3 4 I'4L 5 6 7 8 9 10 11 12 13~ 14 15 16 17 18, 19- 2O 145S0 Echo S[reet A~chorage, Alaska 99516 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST T. N. ~,~ RANDY LOT ~ Township, Range, Section: SEC 2~o., T 12H~ R :Sk; SLOPE SITE PLAN Lo4~4 WAS GROUND WATER ENCOUNTERED? I IF YES AT WHAT DEPTH? Oeplh 10 Water Aller Moniloring? _]j,5-. ~- _~ Reading ~TAR Date 3:03 zt:V2 Net Time ~o Depth to Water 2~/a 25 ",d ~, '., PERCOLATION RATE ~ (oO Iminutes/mchJ PERC HOLE DIAMETER ~" TEST RUN BETWEEN 5.7~ FTAND , ~.2,.~ FT COMMENTS ,~EE AC¢o~PA~'-hflG $ITE ~N ~O~ 5~IN~ TIE~ / ~E~T ~oLE LoC~TI~ .. ~.T. ~NST~. ' ' Net Drop PERI~ORMEDBY: FLATTOP TECfl. 5VC_5. ~_ ~'-.-.c~ ~ CERTIFYTHATTHISTESTWASPERFORMEDiN ACCORDANCE WiTH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE, DATE: 72-008 (Rev. 4185) PERFORMED FOR: LEGAL DESCRIPTION: PT t 5/1 2 3 4 NL 5 6 5P 7 9 B. tt. 10- 11 12 13 14 15, 16 17 18 19 20 ~4530 Echo Street Afichorage, Alaska 99516 Munlcipalily of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 'L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST T.~t. ~5 RAN[:)'-/ B41LEY LOT MOIST Township, Range, Section: SEC .2fo., T 12 h[~ R 3Al SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? Depth to Water After Monilorino? ....... IJaic: .... L O P E Reading Gross Time Net Time Depth to Water PERCOLATION RATE -- (mmutes/inch) PERC HOLE DiAMETER TEST RUN 6ETWEEN FT AND FT COMMENTS lxlo ~. '~. ,,~ ~ /w l l e& ' Net Drop PER~'ORMEDBY: FLA'TTOP 'r'gcft. SI/CS. I ~'"~~ CERTIFY THAT THIS TEST WAS PERFORMED iN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ~ /'~-//,~ Z, 72-008 (Rev. 4/85) PERFORMED FOR: LEGAL DESCRIPTION: 2 3 4 5 6 7 8 9 10 11 12 13 14. 15 16 17 18 19 20 F/6tl6~ Te~chhlc~I S&~iC~s 14530 Echo Street Ahchorage, Alaska 99516 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST RANDy B/iILEy REbblSH $.4,',IDY LOAM SILT · . ............... ~. ~THEODoRE F ~OO ' ' ,~ i / DATE PER~b~MED:. · ~12ol~z Township, Range, Section: SEC 2~ T 12 N R 3~ SLOPE WAS GROUND WATER ENCOUNTERED) Gross Time IF YES, AT WHAT DEPTH? Depth Io Waler Alter MonitorinD? Date: Reading Date SITE PLAN Net Time Depth to Water Net Drop PERCOLATION RATE . tmlnutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN ~ FTAND . FT COMMENTS . .,~'g ~CCoPtp,,~I,.["{I~G <~ lTL 'i~LAN ,c'OF~ SA/'IN~ 'TIE~ / ~'E~T ~OL~ LiDC,~TiO~I_ PER¢ORMEDBY: 1F'L~T~OP 'T'~-mClL/. Si/CS. i ~"~¢~ ~ CERTIFY THAT THIS TEST WAS PERFORMED iN ACCORDANOE WiTH ALL STATE AND MUNICtPAL GUiDELiNES iN EFFECT ON THIS DATE. DATE: 72-008 (Rev, 4/85) PERFORMED FOR: LEGAL DESCRIPTION: 2 3 FtL 4 5 6 7 8 9 10 11 12 13 14 15 16 17, 18- 19- 20 COMMENTS ',~EE ~ .T, SET 14530 Echo $~reet Anchorage, Alaska 99516 Mun~c~pafll¥ of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST RAND'/ BAILEY LOT ¢o GARRET$oH Township, Range, Section: SEC SLOPE " REDDI£R S;4ND¥ SITE PLAN GRAY G~A VE L L ,¢ sP/s WAS GROUND WATER ENCOUNTERED? IN, TE~ ~l[[b WITI IF YES, ATWHAT DEPTI I? TAN ~L Deplh to Waler Alter Depth to Water Net Drop Reading Date [ Gross Time Net Time PERCOLATION RATE TEST RUN BETWEEN ITE PL,qN F'o~ (manutes/inch) PERC HOLE DIAMETER . FT AND FT PERI~ORMEDBY: F~-,~'l~'Oe 'T~ciL/' SI/CS' I ~"~ ~'~"~':~ CERTIFY THAT THIS TEST WAS PERFORMED iN ACCORDANCE WITH ALL STATE AND MUNICIPAL GU[DELiNES iN EFFECT ON THIS DATE. DATE: 72-008 (Rev, 4/85) PERFORMED FOR: LEGAL DESCRIPTION: J.-. O T PT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19- 20- Fj&t[6 T ch'nfc l 14580 Echo S[reet Affchorage, Alaska 99516 Municipality o! Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST RAND"/ Township, Range, Section: SEC 2~,., T 121~ R 3t, v' SLOPE SITE PLAN ~I~AY ~RAVELL"J SiLT IF YES, AT WHAT DEPTH? Depth Io Water Alter Monilering? .... Datc: Reading GROSS Time Net Time Depth to Water Net Drop PERCOLATION RATE (m~nutes/,nch) PERC HOLE DIAMETER __ TEST RUN BETWEEN __ FTAND FT COMMENTS . 'SEE' ACco~pA~'h~ S ITL '~LAN FoR $k..~4; T~E~ / TE[T ~oZg LOCATiO~ No ' ' PER~ORMEDBY: ~A~O~ T~C~, ~vc5. i ~ ~ CERTtFY THAT THIS TEST WAS PERFORMED iN ACCORDANCE WITH ALL STA~E AND MUNiCiPAL GUiDELiNES iN EFFECT ON THiS DATE. DATE: . ~ ~ 72-~8 (Rev. 4/85) PERFORMED FOR: LEGAL DESCRtPTION: F~&ffS~ Te-chnfcal 14530 Echo Street · ~f/c~horcrge, Alc~sk~r 99518 Municlpalily of Anchorage DEPARTMENT OF HEALTI-I & HUMAN SEI]VICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST T.I-I. ~ ~ DEPTH (F_~_~T) pT' 2 3 Ifil 4 5 6 7 8 9 10 11 12 13 14 15 16 18 19, 2O RAND"/ LoT /~ REDDISH SANbY L o.4 PI .SANb IN POC~'ET<~ NEAR BOTTOM COMMENTS _~EE f~C¢chtpAl'.l"[hqG __ ~Ei~C.. TEST Co'41;>,.'CTEO tN G RA't CRIW£ TDENSE. COt'IEStVE $CATTE~Eb SEAMS Township, Range, Section: SEC 2~0, T 12h/ SLOPE ,~ILT WAS GROUND WATER ENCOUNTERED? N ! S IF YES, AT WHAT L DEPTit? 0 P E R 3~v' SITE ~LAN Reading Date Gross Net Depth to Net Time Time Water Drop ~"soA~ q/~ ~/: '~2 2'7 lo: q'7.. 2~, 'fig ~: s~ PERCOLATION RATE ~0 (minutes/mch) PERCHOLE __ TEST RUN BETWEEN , -/.~' FTAND 3 .... ' ' . -- CERTIFy THAT THIS TEST WAS PERFORMED iN ACCORDANCE WITH ALL STA~rE AND MUNICIPAL GUIDELiNES;i~ EFFECT O:; i'HiS DATE. DATE: __ ~;~ /"~ ¢ /~ ~__ 72-008 (Rev. 4/85) --- PERFORMED FOR: LEGAL DESCRIPTION: DEPTH (FEET} 2 3 4 6 7 8 9 10 11 12 13 14 16 18 2O COMMENTS .,SEE t4, L PT 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST T ~. ~o RANDy Bd~L C-'¥ FI&II6~ T¥Chnicb! Servzce~ 14530 Echo Street ,'-~.. .-:~..~ I'~.. Afichorage, Alask~ 99516 MunlcipalHy o~ AnChorage DEPARTMENT OF HEALTI-I & I IUMAN SEItVICES / ~)~'., CE- LOT ~ ._~_~ARRETSDN Township, Range, Section: SEC 24o T,~_.~__~2~ R 3~v' SLOPE SITE PLAN $1MI/..JP. TO T,N.~q WAS GROUND WATER ENCOUNTERED? N IF YES, AT WltAT DEPTR~ ' P Oeplh lo Waler After I'tUDDY ~OT'rOt'l E ~ ' Reading Date Gross Net Depth to Net Time Time Water Drop PERCOLATION RATE ~ (minutes/mchjPERCHOLEDiAMETER . TEST RUN BETWEEN __ FTAND . FT PERC'ORMEDBY: ~._~LATTO? T£CfI,. gl/CS. , ¢.~.~C~ CERTIPY THAT THIS TEST WAS PERFORMED iN AOCORDANOE WITH ALL STA'TE AND MUNiCiPAL OUiDELiNES iN EFFECT ON THJS DATE. DATE: L~/' '~1 /~)~ 72-008 (Rev, 4/85) ~ MUNICIPALITY OF ANCHORAGE ! DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AN~WELL INSPECTION REPORT NAME - PHONE MAILING ADDRESS LEGAL DESCRIPTION 'Ne. OF BEDROOMS ~ Z I Manufacturer ~ Material ~No, of compartments ~ ~ Liq. capacity in gallons Inside length Width Liquid depth i ;~ ~ ~OME~: ~~.... Well ~/ Foundation Nearest lot line PERMIT NO.  DISTANCE TO: // v ~ .. /~, ~ _~ IO~.~ ~ No. of lines~ Length of each line Total length of lines Trench Widt~z Distance between lines 7~ ~ ~ ,nches ~ Top of tile to~ finish grade~ ~ . Materialb~nea~t~le ~ Total effecti~ absorption Length ~t Depth ~_~- PERMI~O,  Well /~ Building foundation ~rest lot line C DISTANCE TO: ~ Class~F/ /~ Depth Driller Distance to lot line PERMIT NO. ~ Building foundation Sewer line Septic tank Absorption area(s) ~ DISTANCE TO: : SOIL TEST RATING REMARKS i i 1 APPROVED DATE LEGAL I'-llJl'-.I T i--: T F'I----IL T T'"r' CIF Rf-,IC:HCIP..'i-"tIJb_ [:'EPARTMENT '-- HEALTH AND EN"/IRONMENTAL -'~:nTEC:T!AN F-L'---' F, ."~_ I---I E ! L R ~-~ r':, PERMIT NO. APPLICANT L.H. CONSTRUCTION., LOCATION NORTH PARK DRIVE LEGAL LOT 6 GRRRETSON STREET., ANCHSRAGE, AK. :264-4720 INC. 5:740 BONI FRC:E LOT SIZE 47500 SQl_tARE FEET TYPE OF ~SAIL ABSORPTION SYSTEM IS' TRENZH MA',:..',IMI_IM NUME:ER OF BEDROOMS = 4 SOIL RATING (SQ FT,./BR)= 225 THE REQUIRED SIZE AF THE SOIL RBSOF.'.PTION SY.S~ IS: [:',E F' T H = 12 L E f-4G T H =~.-'EL DEPTH= ~ THE LENGTH DIMENSION IS THE LENGTH ,:;IN FEET;:, OF THE TRENCH OR DRRINFIELD. THE DEPTH OF R TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE EXCAVATION (IN FEET). THERE IS NO SET WIDTH FOR TRENCHES. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE AND THE BOTTOM OF THE EXCAVATION (IN FEET). ~:E _F-.!I_I I ~:ED ';EPT I I~ TRr4F:-'. S I ZE= 125£'~ F'ERMIT RPPLIF:RNT HAS THE RESF'ONSIBILITY TO INFORM THIS [:,EF'RRTMENT DURING THE INSTALLATION INSPECTIONS OF ANY WELLS R[:,JAF:ENT TO THIS PROPERTY AND THE NUMBER OF RESIDENCES THAT THE WELL WILL SERVE. TI---IL'-~ ,:_' 2 _-~-i I I'-.ISF'EC:T I C~I'-.IS AE:E RE~_-":I-_I_I I E:E[:-, BRF:KFILLING AF ANY SYSTEM WITHOUT FINAL INSF'ECTION AND APPROVAL BY THIS DEF'ARTMENT WILL BE SUBJECT TO PROSECLITION. MINIMUM DISTANCE BETWEEN A WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS 100 FEET FOR A PRIVATE WELL OR t50 TO 200 FEET FROM R PUBLIC: WELL DEPENDING UPON THE TYPE OF PUBLIC WELL. MINIMUM DISTANCE FROM A PRIVATE WELL TO A PRIVATE SEWER LINE IS 25 FEET AND TO A COMMUNITY SEWER LINE IS 75 FEET. WELL LOGS ARE REQUIRED AND MUST BE RETURNED TO THE DEPARTMENT WITHIN 30 DAYS OF THE WELL COMPLETION. OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER INSTALLATION. I CERTIFY THAT i: ! RM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET FORTH BV THE MUNICIPALITY OF ANCHORAGE. 2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES. 2: I UNDERSTAND THAT THE ON-SITE SEWER S~'STEM MAY REQUIRE ENLARGEMENT IF THE RESIDENCE IS REMODELED TO INCLUDE MORE THAN 4 BEDROOMS. S I GNED: ........................ AF'PLtCRNT L.H. C:ONSTRLIC:TIFIN., INC. Department 825 264-4720 * * * HANDWRITTEN PERMIT * * * WELL AND/OR ON-SITE SEWER PERMIT Appiic t:_ /NC. Mail±ng Ad.ess: Location: ~. P~M ~f. ? Phone Number: Legal Description: A L ~FF~ O~ Type of Soil Absorption System Is: Trench: X Drainfield: Seepage Bed: Maximum Number of Bedrooms: --MUNICIPALITY OF ANCHORAGE-" f Health and Environmenta. 2rotection L Street, Anchorage, AK. 99501 n~t Size:49b--O O Holding Tank: Soil Rating (sq. ft/br) ~ The Required Size of the Soil Absorption System Is: DEPTH /,~., EENGTH 3.7 GRAVEL DEPTH ~ WIDTH The length dimension is the length(in feet) of the trench or drainfield. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(in feet). There is no set wi~tth for trenches. The gravel depth is the minimum depth of gravel between the outfatl pipe and the bottom of the excavation(in feet). * * REQUIRED SEPTIC(HOLDING) TANK SIZE = /':'~'~O GALLONS * * Permit applicant has the responsibility to i~form this department during the installation inspections of any wells adjacent to this property and the number of residences that the well will serve. * * * TWO(2) INSPECTIONS ARE REQUIRED * * * Backfilling of any system without final inspection and approval by this department will be subject to prosecution. Minimum distance between a well and any on-site sewage disposal system is 100 feet for a private well or 150 to 200 feet from a public well depending upon the type of public well. Minimum distance from a private well to a private sewer line is 25 feet and to a community sewer line is 75 feet. Well logs are required and must be returned to this department within 30 days of the well completion. Other requirements may apply. Specifications and construction diagrams are available to insure proper installation. * * * PERMIT EXPIRES DECEMBER 1 9 8 1 * * * I certify that: (1) I am familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage. (2) I will install the system in accordance with codes. (3) I understand that the on-site sewer system may require enlargement if the residence is remodeled to include more that 3 bedrooms. Issued by: Signed: Applicant Date: SWP/024 (1/81) Location: Legal Oescripeion: ~ _~ ~dFFd1~ ~,~ LOt The Reguire~ Size of the ~oii Absorption $yste~ ES: DEPTH /~. _ ~ ~__. ORA~L ~ _~ WiD~ ~e [~ag~h d~ns[on [~ ~a length(tu ~emt) o~ the ~ucb or ~a~fiald. ~ the ~tt~ o~ the excavation(in feet). ~ero is ~ ~t w~th loc t~ch~, ~e gravel d~th ~ ~e m~ depth o{ gcawek ~t~ tho ~tfalk ~ ~ t~ ~tt~ of tbs ~avatio~{ia f~t). Pecmi~ 4ppl[caA~ ~{ thru re4~nsibili~y eo info~ ehiG d~r~nt 4~i~ t~ ins~allag[o~ ~$~ti~9 o[ any wells adj4o~ ~o ~hi{ pretty a~ ehe n~: of res[de~e9 tha~ ~h .Ll viii s~rva. ' aek{illin~ o{ ~ny sysg~ vLt~ut [~nal in~elon ~ affroval by thim dm~l: ~L~n~,m dista~e between a ~1l and any on-site sewage disposal syst~ ~or a prtva~ yell or 1~0 ~o 200 f.t f~ a public veil d~inq ~u of public ~ll. M~ 4ist~e Er~ a private well tO a pciva~ ~c Ls 25 and to a c ity kine is 75 feet. ~ l~s are a~ ~$~ ~ ~n~ gO ~hi{ d~rtz~ within 30 day{ of ~h{ wall Othe~ r~Lr~nts My ~ly. Sp~ificakion~ a~ <~st~t~ 4~gCa{ avai%ab~e to insure pr~r ~stallati~. I <~rtify c~t: (1) f ~ ~ailiar wi~h ~{ ~[rmn~ for on.ire ~rs and ~I~{ set fo~h by t~ M~l~aktty of ~rage. issued by: ~ate: SWP/O24(l/$t) PERFORMED FOR: LEGAL DESCRIPTION: 1 2 3 4 5 6 7 8 9 10 11' 12 13 14 15~ 16- 17 18 19 20 COMMENTS SOILS LOG MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST PERCOLATION TEST L~/./ CoN CsTRdcT' iol, J /NC DATE PEREORMED: SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? E Reading Date Gross Time .'~COLATION RATE ~ O TEST RUN BE~EEN / FT AND Net Depth to Time Water - 17 ~ '~- 17.~- .:~ o ~..E. o (minutes/inch) Net Drop PERFORMED BY: CERT,E,EDS : BOX 1369~ t~rAR RO~-m.- A ANCgORAO~.~ ~ 99502 SIX INCH WATER WELL DRILLED AND CASED OUT TO THE DEPTH OF DRILLED AT THE RATE OF $27.00 PER FOOT. r. 8~ // Cor~,t. 345-4572 333.-8742 PROPERTY OWNER 180 LOCATION OF WELL SITE DRILLER WELL LOG: 0 ..... 19' 1~ .... 46' 46---180' Cou.~e q~zu~. S ¢cre. rai ~rmnd_,L .boudate,,~. 15~ c.J~?. /~a, te,r Z, em.,rXn4 q.,t.a,-m&~ a p. orou~ ,t~p.~ mxz, t.e,,tX, ag Qu~t~ 167 go 174 ~-~. /~ p, wdu, e_tX. or~ o~t 4 ~ 3 3;~ zztk i30 ~ o~t ~aaZe.'~ ,,~ o~4t bo,t.t~t~ 3/4 I~o,'~e $~.be. ~ ,,trou2xt .be ,t.,~ZadJ.ed 15 ~ o~t ,ba,t.i;~ Co~.t. o~ g,~2d..tn~: $21.00 p.e_vr ~goo,t. X 180 ~_.,~: $3780.00 Co,~.t oZ U~ti Sead.: $20000 COST INCLUDES ALL LABOR AND MATERIAL FOR COMPLETION OF' SAID DRILLING. WRITE CHECK PAYABLE TO RAMPART DRILLING WORKS FOR THE SUM OF $3800000 THANK YOU VERY MUCH. DATE BERNIE CLAUS OF RAMPART DRILLING WORKS ar~,VlC, r' c~4Agc, rnl:' Iv.~-_ r~r'~ MONTH WILL N MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 Parcel I.D. # CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING ~'-'~ - L\~,,.~- L.:\~,~ HAA# 1. GENERAL INFORMATION Complete legal description LoT (o., ~,4R,~ET son 5/'C) Location (site address or directions) Property owner Mailing address Lending agency Mailing address -1131 No,~T/4 Day phone Day phone Agent Address Day phone Unless otherwise requested, HAA will be held for pickup. NUMBER OF BEDROOMS: TYPE OF WATER SUPPLY: Individual well Community well NOTE: Public water If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. TYPE OF WASTEWATER DISPOSAL: Individual on-site Holding tank Community on-site NOTE: Public sewer If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025 (Rev. 1191) Front MOA #21 STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm FLAfToP TEcH Address I~( 5'3o ECHo Engineer's signature ,~~ Phone 3q5--135'5- , /tUCH ,AK ~.. ~ Date 7/~'~-/9_7 DHHS SIGNATURE ,/~'_ Approved for Disapproved. Conditional approval for bedrooms, with the following stipulations: Additional Comments ~'££ '~ £?TE/~ER 21: / ? ~2 L £/'TEt'~/r 2n TE~ The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72~125 (Rev. 1191) Back MOA#21 Municipality of Anchorage Department of Health and Human Services HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: LoT A. Well Data Well type Log present (Y/N) Total depth ~ ~A~E'T $ oN 5'Ui5. Parcel I.D. If A, B, or C, attach ADEC letter. ADEC water system number bi Date completed ~ /15'/81 Driller Cased to /'/~' (?~ I~oc/<") Casing height 33" Sanitary seal (Y/N) ~' Date of test Static water level Well flow Pump level1 FROM WELL LOG Wires properly protected (Y/N) 7' AT INSPECTION /"/ 'r~ -q' g.p.m. ~ (~ ~ 123 ' MUNIC!PALITY OF ANt HOJ~,GE ENVIRONMENTAL SER~, iCES DIVISION EmCEIVED SEPARATION DISTANCES FROM WELL TO: Septic/holding tank on lot l O} Absorption field on lot Public sewer main Sewer service line '7~' ; On adjacent lots ; On adjacent lots Public sewer manhole/cleanout Petroleum tank NoNE WATER SAMPLE RESULTS: Coliform 0 ¢c,i [~oo ~ ~- Date of sample: 7/~ /c/z Nitrate ~-~' ~, (-~_ Other bacteria Collected by: B. SEPTIC/HOLDING TANK DATA Date installed I o/~ 2_ Cleanouts (Y/N) High water alarm (Y/N) Date of pumping 7/~' / c~ '5 Tank size 1 2. 5 o CA~. Compartments Foundation cleanout (y/N) ~ Depression (Y/N) N.A. Alarm tested (Y/N) N./~. Pumper J SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO: Well(s) on lot Ib l On adjacent lots To properly line ~°~ Absorption field z/o ' Foundation 2. o Water main/service line 5'0 Surface water/drainage ~ loc) 72-026 (3/93)' Fro~t CONTINUED ON BACK PAGE C. LIFT STATION Date installed Size in gallons Vent (Y/N) High water alarm level Meets MOA electrical codes (Y/N) "Pump on" level at SEPARATION DISTANCE FROM LIFT STATION TO: On adjacent lots Well on lot Manufacturer Manhole/Access (Y/N) "Pump off" Level at Cycles tested D. ABSORPTION FIELD DATA Date installed 10/?2 Soil rating (GPD/Ft2) O. 2 2 Length ~'7 + Io~ : 1~2 Width 2_ Gravel thickness Total absorption area 2(o$8 F(,z Cleanout present (Y/N) ~/ Date of adequacy test 7//G/? ~ Results (pass/fail) Water level in absorption field before test I O Peroxide treatment (past 12 months) (Y/N) SEPARATION DISTANCE FROM ABSORPTION FIELD TO: Well on lot Il To building foundation 3 s ' On adjacent lots ~-2 o' Surface water Curtain drain 14,A. Sudace water System type Total depth E. ENGINEER'S CERTIFICATION Depression over field (Y/N) P/~ S$ for LC After test If yes, give date Iq On adjacent lots ~/oo' Property line To existing or abandoned system on lot Cutbank t4,/~, Water main/service line Driveway, parking/vehicle storage area z~ o I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effec24~_ lc,~f this inspection. Signature $ Waiver Fee $ Date of Payment '~- / ~' ~& Date of Payment Receipt Number ~ ~¢ ¢~ Receipt Number 72-026 (3/93)* Back Bedrooms CIVIl. & ENVIRONMENTAL ENGINEERING * ENERGY CONSERVATION & A~ALYSD~ THEODORE F. MOORE, P.E. 14530 ECHO ST. PH: (907) 345-1355 September 21, 1992 ANCHORAGE, ALASKA 99516 M.O.A. DHHS Attn: Dan Roth or John Smith P.O. Box 19-6650 Anchorage, AK 99519 Dear Sirs: This submittal is a follow-up to our discussions on September 15. The purpose of this letter is to provide the required design narrative in support of our application for a permit to upgrade the wastewater disposal facilities for the 4 bedroom residence on Lot 6 of Garretson S/D, located at 7131 North Park Drive. Soils logs, perc test results, a site plan, design drawings and specifications are enclosed for your review. The existing soil absorption system was installed in 1981 and consists of a 1250 gallon septic tank followed by 75 lineal feet of soil absorption trench containing 6 feet of sewer gravel. The soils test conducted prior to construction reported a measured percolation rate of 20 minutes/inch. The system was sized on the basis of 225 square feet per bedroom. After a number of years of problem-free operation, the system is now in a state Of failure, requiring periodic pumping to prevent sewage from backing up into the house. During August and September of this year we dug 10 test holes on the lot in an effort to detet'~ine the optimum site for a replacement system. The predominant soil type on this lot is a dense gray gravelly silt. · While several of the test holes showed pockets and/or thin veins of sand and gravel, we were unable to identify a large enough contiguous area of granular material to design an upgrade in it. Three different pert tests conducted in the silt all demonstrated percolation rates in excess of 60 minutes,per inch. After discussions with Dan Roth and John Smith @DHHS on September 15, we concluded that the only practical alternative to a holding tank is to install a series of oversized soil absorption tzenches. Since the property owner does not need a HAA certificate at this time, it will be possible for an adequacy test to be conducted after the trench upgrade has been in service for at least one year prior to issuance of a HAA certificate. The logs for test holes 7, 9 and 10 are most applicable to the proposed upgrade trenches. Test hole g9 was dug just before several days of rain. The initial perc test showed an absorption rate of just under 60 minutes per inch in the pre-soak phase with 12" of water in the perc hole. On September 8 a significantly slower perc rate was measured due to the fact that the entire bottom of the perc test pit had been saturated by recent heavy rains. On September 10 the perc hole was dug out deeper and a perc rate of 320 minutes per inch was measured. We feel this perc rate is still on the conservative side, both because it was conducted in soils which had been over-saturated, and because it ignores the contyibution of the scattered sahd seams Which constitute an estimated 5 - 10 % of the sidewall area. The monitor, tubes in each of these test holes were dry on 9/17/92, indicating that there is not a shallow groundwater table problem. To develop appropriate sizing criteria for this upgrade, we extrapolated from the required absorption areas in the 1986 and 1990 versions of the wastewater ordinance corresponding to different measured perc rates. From the an examination of the relationship between perc rates and required absorption areas for a range of perc rates, we noted that doubling the measured perc rate results in a 33% increase in the required absorption area, and tripling the perc rate causes a 50% increase in the absorption area. Thus, we calculated that doubling the 60 min/in perc rate to 120 min/'m, and then tripling that to 360 min/in would, dictate a doubling of the required area corresponding to 60 rain/in soils. Since we measured a perc rate of 320 min/in, we have sized the upgrade on the basis of 0.45/2 = 0.225 gpd/sq, ft. The required absorption area for this 4 bedroom residence thus becomes (4 x 150)/0.225 = 2667 square feet. Using a gravel depth of 7' below the horizontal distribution pipe, the required trench length is 2667/(2 x 7) = 191 lineal feet. The propOSed upgrade design achieves this with 2 parallel trenches of 105' and 86' lengths spaced a minimum of 20 feet apart. This sizing criteria does not count the contribution of the scattered sand seams which were noted in several of the test holes. By virtue of the trenches extending so far across the lot, the system should maximize the interception of these sand seams. Since the measured perc rate is so slow, it is particularly important to minimize any extra water coming into the trenches from surface runoff, particularly during breakup. To accomplish this, an existing surface drainage swale, which the property owner conslructed last year, will be re-routed and extended around the north end of the trenches. Even though this swale did not carry any discemable surface flow this year, it's creation is viewed as added insurance. The topography of the lot in the vicinity of the proposed trenches slopes towards the west at approximately 10%. The proposed project will have no significant impact on present or future water supply and wastewater disposal systems serving adjacent properties, nor will it have any impact on reserved space/surface and subsurface, or on areawide drainage concems. Please give me a call at 345-1355 if you have any questions on this submittal. Sincerely, Ted Moore, P.E. CIVIL & ENVIRONMENTAL ENGINEERING " ENERGY CONSERVATION & ANALYSIS THEODORE F. MOORE. P.E. July 12, 1993 14530 ECHO ST. PH: (907) 345-1355 ANCHORAGE, ALASKA 99516 Randy Bailey 7131 North Park Drive Anchorage, AK 99516 Dear Mr. Bailey: Per your request on July 6 we conducted adequacy tests of the water supply and wastewater disposal systems serving your residence on Lot 6 of Garretson S/D. Our test results indicate that both systems are adequate, and we are in the process of applying for a Health Authority Approval (HAA) certificate from the Municipality. The following is a description of our test procedure and findings. According to the driller's log, the well was completed in August of 1981 and has a total depth of 180 feet and a yield of 4 to 5 gpm. On the date of our test the static water level stood at 44 feet below the top of the casing. During the course of our test we pumped a total of 724 gallons of water from the well at the maximum pump output of 6.4 gpm, which caused the water level inside the casing to be drawn down to 128 feet, but no further. Based on our test data we determined that the total yield of the well is in excess of 6.4 gpm, which exceeds the Municipal criteria for approval of a single family residence, and also meets the FHA criteria that a well be able to supply 720 gallons of water within a 4 hour period. Water samples collected on July 6 were satisfactory, showing no bacteria per 100 ml., and 0.29 mg/l of nitrate-N. In October of 1992 a new wastewater disposal system was installed to replace the original system which had been installed in 198 I. The new system consists of a 1250 gallon septic tank followed by two parallel soil absorption trenches with a combined length of 192 feet, each containing 7 feet of sewer gravel. The soil absorption trenches were sized at double the maximum s~ze normally used to compensate for the fact that the soils in this area have a very slow percolation rate. Usually an adequacy test is not required to be performed on a newly installed system prior to issuance of a HAA certificate, however because the design was unconventional, the Health Depa~iment felt an adequacy test would be appropriate. To assess the adequacy of the system we arranged for a pump truck to add 3000 gallons of water into the upper trench, after which time we mn another 724 gallons of water into the first cleanout pipe downstream of the septic tank. The fluid levels in the septic tank and in the soil absorption system standpipes were monitored before, during and after the flow of water was stopped. The initial fluid depth in the upper trench was 10 inches and the lower trench was dry. The addition of 3700 gallons of water caused the fluid depth in the upper trench to rise another 39.5 inches, which was still below the overflow pipe connecting it to the lower trench. After the addition of water was stopped, the fluid level in the upper trench alone receded at a more than adequate rate for a 4 bedroom residence. In conducting an adequacy test we attempt to provide a thorough, conscientious engineering analysis of the system. The reported results describe the performance of the system under the conditions encountered at the time of the test. Septic systems do deteriorate over time and satisfactory test results do not guarantee future performance of the system under different conditions. Please feel free to give me a call if you have any questions on this report. Sincerely, Ted Moore, P.E. MUNICIPALITY OF ANCHORAGE ~ DIVISION OF F~N~IRO~-~fENTAL ~%LTH & DEPARTM~N~f OF ~TH ~%~ EN~IRO~ ~O~CTION ;3~IC~ION FOR ~,~TH A~HORI~ ~OV~ ~RT~iCA~ 1. ~er~ I~fo~ation Application Date (a) Legal Description (include io~, block, subdlvision,~ection, to.ship, ra~e) ~T ~ ~ ~e~ ~c~ ~/2 ..~ ~3.~ ~ ~3c 2 ~- Location (address or directions) (b) Applicants Name (c) Applicant is (check one) Lending institution Buyer I i ; Other! ~ (e~piain); ~, h-, z ~ ..... Telephone - Home Busines~-'--- Applicants ~dress (e) Real Estate Co & Age~. .... ~ .... ~ ,'~/~,:~ ....... Address -. ~>.' ~ ~'~ ./ ~,pff~z~ : :-~. ~ Telephone (f) Mail the ~--~-& to the following address: 2. Type of Residence Single-Family!~-:~-~i Number of Bedrocms 3. Water Supply Individual We!ii !¢ulti-Family ! Other (describe) Note: If community well system, must have w~itten confirmation from the State Department of Environmental Conservatien attesting to the legality and status. 4. Sewage Disposal Note: If community well system, must have written confirmation from the State Department of Envirop~ental Consent-at!on attesting to the legality and status. [Page 1 of 2] Engineerin~ Firm Providing Inspections, Tests~ File Search, Data and Information A~ certified by my seal affixed hereto and as of the validation date shown below, I ver£fy that ~ investigation of this Health Authority Approval shows that the on-site water ~upply mnH/or w-astewater disposal system is safe, functional and adequate for t~ ~ber of bedrooms and type of structure imdica:ed herein, i further verify that, ba~ed on the information obtained from the l~nicipality of Anchorage files a~d from my investigation ~d inspection, the om-si~e ~ter supply and/or wastewater disposal mystem is im compliance with all l~nlcipai and State codes, ordinances, and regula- ~ior~ ~z~ effect on the date of this inspection. ~ff~P Approval Approved for Approved Telephone (Ei';Gt~ER SEAL bedrooms By Disapproved __ Ter-~s of Conditional Approval CAUTION ~ :~;ICiPAZITY OF _~;CHORAGE b~ZP.~J~._~ENT .c: ;~AZTE A~ a_~ .... ~h~.~ ~OTECTION . ~v o=OJ ~ F~PRESE~- ~iO~ ~N El P~--~ 5 ~0-~ BY ADl LNDEPE~Eh~ ~OFESSIO~L ENGIh~ER P~GISTE~ ~,~. ~ ~EP ~ES ~iS AS % COL~SY TO PL~C~kSERS OF EO~S ~D _,o~I~I~,~ ~ OP~ER TO SATISFY ~DEP~ ~,D S~.~ . ~ ~iNG ~'"- , ~ ~ ..... CER~!N '"~ ~QU~E- ~'~7~S. ~0~E3 OF ~EP DO NOT C0:~UCT E:SPECT!0:S OR :&~ALYZE DATA BEFORE A , ~T~iCA~ ~ ISSL~D. ~ ~.~I~P.~ :~C~OP-&~ NOT ~SPONSIB~ FOR ~ORS (DHE? =.~Alej/Di8 [Page 2 of 2] 7-19-84 MUNICIPALITY OF ANCHORAGE (MOA) HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST- FEBRUARY 1984 264-4720 Legal Description: / ~ T A WELL DATA Well Classification Well Log Presen~N) Total Depth /'~O/ Cased to /?/::,;z / Static Water Level ~/_ ~ Casing Height Above Ground ',~"~ / Electrical Wiring in ConduitS) Separation Distances from Well: If A, B, C, D.E.C..Approved (Y/N) Depth of Grouting '~ Pump Set At ~ Sanitary Seal on CasinO'S4} *' Depression Around Wellhead (Y(~ ~ To Septic, Holding Tank on Lot Standpipes(~N) Depression over Tank (Y~/} Pumping/Maintenance Contract on File (Y/N) Holding Tank High-Water Alarm (Y/N) Separation Distances from Septic/Holding Tank: To Water-Supply Well ~t'To Property Line To Water Main/Service Line /L ,,¢.;~ /¢"~ Course ¢1~l O~:) ~ ; On Adjoining Lots 7~ ,//~1~/~'/'- '/~To Nearest Edge of Absorption Field on Lot //~'/''X~ ; On Adjoining Lots To Nearest Public Sewer Line ,4./?t~, %' To Nearest Public Sewer Cleanout/Manhole ~"-~E To Nearest Sewer Service Line on L.o~ , Water Sample Collected by ~ ; Date '"~;~:2/~"(~'- ' Water Sample Test Results ~ ~/,~ fi~.~, /C-~ 7~/~ ~ Comments ~) ~ , ~ SEPTIC/HOLDING TANK DATA Size /'7__~) No. of Compartments Air-tight Caps ~) Foundation CleanoutCN) Date Last Pumped "~/D ~/;~,.~'- /~ .¢C Temporary Holding Tank Permit (Y/N) To Building Foundation To Disposal Field (¢ / To Stream, Pond, Lake, or Major Drainage Page 1 of 2 C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata Date Installed ~'//<~/~'/' Width of Field 4~Square Feet of Absorption Area Depression over Field (Y~ V ,~Results of Last Adequacy Test Type of System Design Length of Field Depth of Field Gravel Bed Thickness ~ ! Standpipes PresentON) Date of Last Adequacy Test To Property Line ~'~ / ~ 4 To Existing or Abandoned System on Separation Distance from Absorption Field: ,,~To Water-Supply Well /('~'/'~ To Building Foundation ,-~;/'~- Lot /t~ ~ ; On Adjoining Lots To Water Main/Service Line ~ ~ /~ To Cutbank (if present) ,~/~ To Stream/Pond/Lake/or Major Drainage Course ~ / O O ~';~"~ To Driveway, Parking Area, or Vehicle Sto. rage Area~ _.~J~~;z~,~ ';~z'~" / "J~'-- D. LIFT STATION Date Installed / / Size in Gallons/ "Pump On" Level at High Water Alarm Level at Tested for Electrical Co~es (~. I Dimensions · ! , / ~""'~"PumpOff"Le~el;t ~ / ~ Vent(Y/N) Pumping Cycles during Adequacy Test. Meets MOA ** Check Permitted Bedroom Rating Against HAA Request ** I certify that/'~ave checke~ verified, or copformed to all M~JA and]HAA guidelines in effect on the date of this inspection. Signed ~ ~,A~ Co p.n No. Date of Payment Amount: $ A~ .~b Page 2 of 2 72-026 (11/84) ALASKA el OIROl mi lqTAL COIqTROL $[ RuiCE$, linC. ~nqine¢rin§ $ [nulronmentoJ Sludles VIC / MARSTON REALESTATE C/O 2804 W NORTHERN LIGHTS ANCHORAGE AK 99503 SELLER-CHARLES WALTERS 8/19/85 VIC / MARSTON REALESTATE C/O 2804 W NORTHERN LIGHTS ANCHORAGE AK 99503 50471 LEGAL:GARRETSON SUBDIVISION LOT 6 ADEQUACY TEST FOR SEWER SYSTEM ADEQUACY TEST DATE-7/30/85 THE TYPE OF ABSORPTION SYSTEM IS A TRENCH WITH AN AREA OF 900 SQFT. THE SYSTEM IS CAPABLE OF ACCEPTING 600 GALLONS OF WATER PER DAY. THE SURGE CAPACITY OF THE SYSTEM IS 472 GALLONS. BASED UPON THE TEST DATA THE SYSTEM IS ACCEPTABLE FOR A 4 BEDROOM HOME. SEPTIC TANK ADEQUACY THE EXISTING SEPTIC TANK VOLUME OF 1250 IS ADEQUATE FOR THIS 4 BEDROOM HOUSE. THE SEPTIC TANK/PACKAGE PLANT WAS PUMPED ON 7/30/85 . FLOW TEST ON WELL WELL FLOW DATE-7/30/85 A FLOW TEST WAS PERFORMED ON THE WELL. 472 PUMPED AT A RATE OF 6.3 GPM OVER A DURATION OF 2 THE DRAWDOWN WAS 87 ' WITH A RECOVERY TIME OF 385 AND THE STATIC WATER LEVEL WAS 39 FEET. THE WELL IS ADEQUATE FOR THIS 4 BEDROOM HOME. - ~'.L~:~],': _., i:: '-','. ~ GALLONS OF WATER WAS HOURS. MINUTES 1200 LU~st 33rd Au~nue ~uil¢ ~, Armc~oroQ8 AIOS,~O 99503.907/ 561-50z:10 RECEIVEE~ INSPECTION APPOINTMENTS j TIME TIME ~,~ TIME DATE DATE ~ ~ DATE MUNICIPALITY OF ANCHORAGE  DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION 825 L Strut - Anchora~, Al~ka 99501 ENVIRONMENTAL SANITATION DIVISION · e,e..o.e R REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES DIRECTIONS: Complete all pa~s oH page 1. Incomplete r~D~ ~ill Dot ~ ~r~, Please allow ten (10) days for pr~essing. 1. ZOPE~OWNER- I PHONE MAI LIN G ~ODR ESS PROPERTY RESIDENT (If different from above) PHONE 2. BUYER PHONE MAILING ADDRESS 3. LENDING INSTITUTION I PHONE MAILIN~ ADDRESS 4, REALTOR/AGENY I PHONE I MAILING ADDRESS 5. LEGAL DESCRIPTION ~T~T LOCATI'0N ~. ,,.,./--< ._, TYPE OF RESIDENCE NUMBER OF~BEDROOMS [] One [] Four ~ SINGLE FAMILY [] Two [] Five [] MULTIPLE FAMILY [] Three [] Six [] Other 7. WATER SUPPLY INDIVIDUAL* [] COMMUNITY [] PUBLIC UTILITY * ATTACH WELL LOG. A well log is required for all wells drilled since June 1975. For wells drilled prior to that date, give well depth (attach log if available.) 8. SEWAGE DISPOSAL SYSTEM L~i~_ INDIVIDUAL/ON-SITE*~ [] PUBLIC UTILITY YEAR ON-SITE SYSTEM WAS INSTALLED. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. THIS SIDE FOR OFFICIAL USE ONLY 1. TYPE OF RESIDENCE NUMBER OF BEDROOMS [~] ~'"~N G L E FAMILY [] ONE [] THREE [] FIVE [] OTHER [] MULTIPLE FAMILY [] TWO ~ FOUR [] SIX PERMIT NUMBER i2. WATER SUPPLY [~INDIVI DUAL DEPTH OF WELL [] COMMUNITY DATE DRILLED [] PUBLIC UTI LITY Connection Verified LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER []I~DIVIDUAL/ON -SITE DATE INSTALLED []PUBLIC UTILITY Connection Verified INSTALLER [~Septic Ta~J( or ~ Holding Tank Size: / ~ g If Tank is homemade SOILS RATING give dimensions: TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL 4. DISTANCES Septic/Holding Tank IAbsorption Ar.a Sewer Line I Nearest Lot Line I I WELL TO: Absorption Area to nearest Lot Line 5. COMMENTS ~~ accompan~ certificate) October 2, 1981 (3) L.tt. Construction, Inc. 3740 Boniface Parkway Anchorage, Alaska 99504 Subject: Lots 4, 5, 6 Garretson Subdivision Approval for the individual sewer and water facilities cannot be granted until the following items have been completed for the properties above: Lot 4 Garretson Subdivision The water analysis report needs to be submitted to this office from the Chem Lab, 5633 B Street, for our review. A well log needs to be submitted to this office for our files and review. The depression over the septic tank and the trench area needs to be filled in and reinspected. Lot 5 Garretson Subdivision (1) The water analysis report needs to be submitted to this office from the Chem Lab, 5633 B Street, for our review. (2) A well log needs to be submitted to this office for our files and review. (3) The depression around the well casing needs to be filled in so that it slopes away from the casing. (4) The hole in the top of the casing needs to be filled so that the cap is water tight. (5) The area over the septic tank and the trench area needs to be filled in. The cleanout needs to have a cover on it. 'L.H. Cons'truction, Inc. OcYober 2, 1981 Page Two '/ (3) Lot 6 Garretson Subdivision (1) The water analysis report needs to be submitted to this office from the Chem Lab, 5633 B Street, for our review. A well log needs to be submitted to this office for our files and review. The hole in the well head needs to be covered so that it is water tight. (4) The depression over the septic tank needs to be filled in with dirt. Please notify this department for a reinspection when the noted descrepancies have been corrected. If there are any questions, please call this office at 264-4720. Sincerely, James S. Roberts Associate Environmental Specialist cc: First National Bank of Anchorage Post Office Box 4-2090 99509