HomeMy WebLinkAboutSHENANDOAH HILLS LT 7Shenandoah Hills Lot 7 #015-212-44 Municipality of Anchorage ,, Development Services Department o= - .~ ._ .. "' ~,- Building Safety Division On-Site Water & Wastewater Program, 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 ~ ~' www.ci.anchorage.ak.us (907) 343-7904 Page I of On-Site Wastewater Disposal System and/or Well Inspection Report Permit Humbert SW050057 PID Number:, 01 5--21 2--44 Name: WILLIAM HURST Wastewater System: [] New [] Upgrade Address: 12030 SHENANDOAH ROAD * ANCHORAGE, AK 99516 ABSORPTION FIELD No. of Bedrooms: Ph°ne:(907) 345--7904 3 D Deep Trench [] Shallow Trench · Bed r'lMound ·Other LEGAL DESCRIPTION ~,, ,~: To~, Depth ,Mm ori0,.., o~.: · 0.5 aPO/Sq. Block: Lot: Subdivision: Depth to plpe bottom from original grade: °ravel depth ben.th pipe: - 7 SHENANDOAH HILLS SEE DWG. Township: Range: Section: RII added abow o~glnol grade: °ravel length: SEE DWG. ,o,,,,,. .id,,: N,,~.,' of ,n",: Joi.~nn" b.t... WELL: [] New [] Upgrade 15 CIo,~iflcation (Private, A.B,C): ~ Cased To: Total abeorpUon area: Pipe mter~l: .-r~\~ ~ .. 900+ so..., D 3034/ F-810 Driller: ~.~,~\~.,~J~'~ D~t.e Drilled: StMJc Woter Level: Ir~teller. I:)~te In"balled: n. AKWWC INC. ~/4-7/200~ o.. ~ ~ ~ TAN K SEPARATION DISTANCES []Se~t~¢ [] Ho~ing ·S.T.E... ·  Septic Absorption Uft Holding =ubllc/Pdwte Manufacturer:. Copecl~ In gallon.: Tank Reid StoUon Tank Sewer Unoa ANCHORAGE TANK/ORE:NCO SY~ILIVlS 1 500 Well lbO'+ 100'+ 100'+ - 25'+ "at'~: FIBERGLASS .um~. of ¢omportment~: 2 S~,o:e Wote~ 100'+ 100'+ 100'+ - - LIFT STATION Size In gallon.: J Idanufactumn Lot Une 5'+ 10'+ 5'+ - - 1500/50IANCHORAGE TANK/ORENCO SYSTEMS 'Pump un' level at: rpump eft" level at: JHIgh water alarm at: Foundation 5'+ 10'+ 5'+ - -- TIMER/20" J TIMER/13'I 46"/22" Curtain Dra~n - NONE KNOW~I Pump Make & Model: rlect~col In,pecflono peffm'rn"d b~: I ' 1~20 OS 05 HHF M.O.A. Remarks: THE EXISTING SEPTIC TANK AND DRAINFIELD BENCH MARK Location and WERE COMPLETELY ABANDONED. BOTTOM OF SIDING NEAR POINT "B" · THIS IS AN ADVANTEX TREATMENT SYSTEM Assumed [Jonathan: · *EXCAVATION was LIMITED TO THE REMOVAL OF lJ;)O.O0 ENGINEER'S SEAt/ ORGANICS. 2.0 TO 5.1 FEET OF M.O.A. APPROVED SAND FILTER ADDED TO r Inspections performed by: AKWWC, INC. Dates:2ndlSt 4./4/20034/5/2003 ~~cO./ zl'(;);~___~ '".'~ , 3rd 4/6/2003 4th 4/7/2003 ~)~e$1.. q:-7{~7~j ..' ..,.,,~ Development~--'"-e-"'--a-'~en'Approval~_~~e, ir,~ ~.. / R~viewe8 and approved by:/_ 4~/2~/~3 (Rev. 12/01) '%~,~ro f e s sTo~'~':=' PERMIT NUMBER: · 015-212-44 tJ[ / ' ~ SH£NANDOAH HILLS ' / ~ S/D; LOT 6 A B C ~ MH2 WILLIAM HURST (907) 545-7904 2 OF 5 A B C ST1 74.91 21.75 47.58 POD 78.88 26.18 51.35 MH1 84.05 31.81 56.00 MH2 86.32 34.35 58.52 MT1 61.29 18.58 - MT2 75.3,3 31.74 - MT3 76.78 72.76 - MT4 83.74 75.07 - PERMIT NUMBER: 015-212-44 /---TOP OF MANHOLE -, ,~ / 9s.78 (AVCO ~ FINAL ORADE - / TOP OF IdANHOLE ~" 97.65-gT.6g 98.80 (AVO.) VAULT ~ G~E = gg.31-gg.g3 ~ ~T ~ ~INSU~ON ~ ~ORIGIN~ - ~2.~7 _~ ~ / / / / ~1~ OF DI~IB~ON UNE - 96.87. THE TOP OF ~D / DI~IB~ON UNE IS 1.25 INCH ~C = g6 27 /A~ ~ INCH HO~ SPAC~ 28 INCH~ ON C~ER ' ~ '] ' (12 PER ~ 72 HO~ TOT~) PR~ED FOR: , PHONE NUMBS: PAGE NUMBER: SHENANDOAH HILLS SUBDIVISION; LOI 7, q~r,'l...l .." PROFILE AS-BUILT DRAWING OF SEPIIC SYSIEM UPGRADE otesslo MOA Fa~'- DDCFaXl 12/2~I/'02 6:49 PAGE 9/25 RightFAX : ,. P~ ~ o~ ~ INSPECTION REPORT MUNICIPAI,ITY OF ANCHORAGE -- BUILDING SAFETY.DMSION 4700 SOUTH BRAGAW STI~EET, ANCHORAGE, ALASKA , :'. INSPECTIONS: Folc~ (907) 343.8300 Fax: (907) 249.7777 INFORMATION: (907) 343.8211 DATE: "~'-["q Ccrr~t/om ~s~,ntial as ,xplair~d b~low.~,,,~ Will ~.exnmine a~ nex~ imp~ztion. [] l'lPOI~g (Stomavatar) , [] c.o. an,roved. [] C.C.O. approved (~ma~nts COM3~NTS: Repon gi,,'~n to: MUNICIPALITY OF ANCHORAGE Building Safety Division MEMORANDUM DATE: April 28, 2003 TO: File of Shenandoah Hills Subdivision Lot 7 FROM: Dan Roth Engineer II, On-Site Water Wastewater Program SUBJ: Waiver of the required 6 feet separation of the bottom of a bed system to bedrock The subject waiver has been granted for a bed system on the above stated lot to impermeable soils of 4 feet instead of the required 6 feet separation. The waiver is granted for the following reasons: * The bed is located 100 feet plus from any water wells. * The area is developed with large lots thus density will remain Iow * The soils are dense silts that will treat septic effluent well in a relatively short distance * The effluent received by the bed is from an Advantex AX 20 wastewater treatment system * Ground water is not extremely shallow (approx ~ 7 feet) MUNICIPALITY OF ANCHORA GE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Apr 01, 2003 Expiration Date: Mar 31,2004 Permit Number: SW030057 ~['L'~'~-I ]D'e~'(~:il~{i(~': ]S'J::IEi',jA'NDOAH HILLS ET ]] 7' Design Engineer: 0041 AK Water & Wastewater Consultan' Owner Name: WILLIAM HURST Owner Address: 12030 SHENANDOAH ROAD ANCHORAGE, AK 99516-2201 Parcel ID: 015-212-44 Site Address: 012030 SHENANDOAH RD Lot Size: 65430 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for the construction of: E~] Disposal Field r~ septic Tank r-] Holding Tank ]---] Privy [] Private Well Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Date: Municipality of Anchorage Development Services Department , Building Safety Division , On-Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERHIT APPLICATION FOR A SINGLE FAMILY DWELLING' Parcel I.D. 0t ,5-212-44 Permit Number ~'~O ~Oo5"7 Property owner(s) Mailing address (1) Mailing address (2) Legal description (Lot, Block & Sub'd.) LOT 7: Legal description (Section, Township & Range) Lot Size ~3%"/"~ ~0 Acres/Sq.Ft. THIS THIS WILLIAM HUR~I' 12030 SHENANDOAH ROAD * ANCHORAGE, AK SHENANDOAH HI!~I~$ N/A Day phone 545-7904 Zip Code SUBDIvIsION 99516 Number of Bedrooms 3 APPLICATION IS FOR: Sewer Only ['-I Well Only E] Sewer and Well [--] Water Storage Sewer Upgrade [] PROPERTY CONTAINS: Hot Tub E] Jacuzzi r-] Swimming Pool [--] Water Softening Unit r'-I Therapy Pool BI I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable ,Municipal codes. ALASKA WATER &: WASTEWATER CONSULTANTS~ INC. -(SignekJre-ofl~roperty owneror c~uthorized-egent)- Permit Fees: '~400 Waiver Fees; Date of Payment: 3/2.7 / 0 ~) Date of Payment: Receipt Number: ,~0'~'1 Receipt Number: ALA SIG WATER & WASTEWATER CONSULTANTS, INC. March 24, 2003 Municipality of Anchorage Development Service Department Building Safety Division On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 Reft Septic System Upgrade for Lot 7; Shenandoah Hills Subdivision ADVANTEXTM TREATMENT SYSTEM To whom it may concern: 1. GENERAL: The existing 3 bedroom home is served by a private well and septic system. The existing septic system is in a state of failure and needs to be upgraded. Two test holes were excavated on the property. We are proposing to design the septic system around the 30 foot radii ofthese test holes. Due to the poor permeability of the receiving soils we are proposing to use an Advantex treatment system and a bed type drainfield. 2. SOILS: See the attached log, which shows the soil classifications, groundwater monitoring, and the percolation test results. 3. DRAINFIELD APPLICATION RATE: The intent is to install an Advantex treatment system that will allow the use ora small drainfield in the area around the 30 foot radii of the test holes. The Advantex system has received class III approval and we are going use an application rate of 0.5 GPD/FT2. 4. BED DESIGN: a. Percolation Rate: 80 minutes/inch b. Proposed Application Rate: 0.5 gallons/day/ft2 c. Number of Bedrooms: 3 d. Design Flow: 450 gallons per day e. Minimum Absorption Area: 900 fi2 f. Total Depth: 1.0 feet (max.) g. M.O.A. Approved Sand Filter Depth: 2.5 minimum h. Effective Depth: 0.5 feet i. Width: 15 feet 6901 Debarr Road, Suite 2B - Anchorage, AK 99504 ~ Ph: (907)337-6179 ~ Fax: (907)338-3246 j. MinimUm Length: 60 feet long k. Effective absorption area: 900 S. ORENCO PACKAGE SYSTEM: The fiberglass tank with the Advantex Treatment System will be manufactured by Anchorage Tank & Welding to meet the latest design criteria established by Oreneo Systems, Inc. The point of contact at Anchorage Tank is Lowell MeNutt. As with their standard STEP tank, it is equipped with a high water alarm per. M.O.A requirements. 6. SURFACE WATER: There is some ponding of water along the north lot line but will be 100+ feet from proposed septic system. 7. TOPOGRAPHY: The average topography in the area of the proposed drainfield is a 5%- 10% slope running approximately east to west. 8. WAIVER TO IMPEARMEABLE SOILS: Two test holes were excavated on the property. Percolation tests were performed in both test holes at approximately 5 feet deep and were found to be impermeable. This impermeable layer was found at a depth of 3 feet in both test holes. A percolation test was also performed at a depth of 1 foot in test hole #1 and found to be 80 min/ineh. We are requesting that the vertical separation distance between the bottom of the drainfield, and the impermeable soil layer, be waived to 4 feet. Justification for this reduced separation distance is summarized as follows: The effluent being discharged to the drainfield is from an Advantex treatment system, which has CBOD and TSS levels that are expected to be less than 10 mg/L. In addition, the total nitrogen levels are expected to be less than the effluent from a lined Intermittent Sand Filter (effluent from an ISF can be discharged into a drainfield that is only 4 feet from bedrock and impermeable soils) There will still be a 4 feet separation distance between the bottom of the drainfield and groundwater There will be no discemable benefit (reduced BOD, TSS, or total nitrogen) achieved by passing the effluent through 6 feet of soil vs. 4 feet of soil. It is generally agreed upon that the pathogen reduction occurs within the first 4 feet of soil, hence the 4 feet required separation distance to groundwater. It is reasonable to assume that by the time the effluent passes through 2.5 to 3.5 feet of imported sand and then 2 feet of the insitu 80 minute per inch soil that the BOD and TSS levels will be essentially zero (0). It is further assumed that there will be no more reduction in total nitrogen achieved by building the mound several feet higher. The highly treated effluent will probably not see further reduction in nitrogen levels without introduction of a carbon source (as is the case with ISF effluent). Based upon the facts presented we are requesting that the vertical separation distance between the bottom of the proposed drainfield and an impermeable soil layer be reduced to 4 feet. 6901 Debarr Road, Suite 2B ~ Anchorage, AK 99504 ~ Ph: (907)337-6179 ~ Fax: (907)338-3246 9. CLOSING: I am open' to any suggestions from your department that would be an improvement to the proposed system. I am unaware of any negative impacts that this installation would impose on adjacent wells, or septic systems. If you have any questions, please call us at 337-6179. Sine Presi{ P.E., M.S. NOTE:/tttached is a site plan drawing, a design drawing, an/ldvantex detail, a trench detail, two soil logs, and a 7 page construction specification letter which are all part of the design package for this septic system. 6901 Debarr Road, Suite 2B ~ Anchorage, AK 99504 ~ Ph: (907)337-6179 ~ Fax: (907)338-3246 I I ' ~ BLOCK 7. LOT 1 BL~K 7~ ~ BLOCK 7. LOT ~ 7 BEo~ ~ i ~ ~ '~LOCK 7. LOT 5 I I %~ (SEE DESIGN PAGE 2 OF 4).-- % .... ~ ./ I ~ ~ SHE~DO~ HI~ I I i I I OONSULTANTS, INC. 69Ol DEBARr rOaD. SUITE ~8 · ANCHOraGE. AK OqSO~ * PHONE (007)557-6[79 ' FAX (qOT)558-SZ~6 ' -- ' ---- PREPPED mr PHONE NUMBER: PAGE NUMBER: SITE P~N FOR PROPOSED SEPTIC S~EM UPGRADE I PROPOSED DRNNFIELD. EXCAVATE A TRENCH THAT _.~.~ "--' ~ '"-'"' I IS 1 FEET DEEP MAXIMUM BY 15 FEET WiDE BY / - \ t~ OF CLEAN, WASHED SEWER DRNNROCK. THE .- / DISTRIBUTION UNES ARE TO BE 1.25 SCH 40 PVC / g.~ WITH 1/8 INCH HOLES SPACED 28 INCHES ON / ~ SHENANDOAH HILLS ~ CENTER (12 HOLES PER LATERAL 72 .HOLES . ~ S/D; LOT 6 ~ TOTAL). (SEE DETNL PAGE 4 OF 4).~ / ~ / / ~Em~NGSE~CTANKTO \ I ~ ~ ~ / / / BE COMPLETELY ABANDONED \ ~. J ~,~ \'\ /! / PER UPC \ ~ J -~-'~ \ \'. DO(; FENCE. MAY HAVE I~ / ~ ~C \ \ \~. TOaEREM~D~ // / ~ \\ \ \ \\ ' ~ / / ~ ~INSTALL FOUNDATION ~ -\\ \ \ \\ # 4 / '7 / CL~O~ \ VAULT (SEE DETAIL PAGE ,3 OF 4). .' ?..-', :. I ~ ~ APPROXIMATE LOCATION OF TOE I ~ OF SLOPE FOR FILL NEEDED DATE: ~:>~**~-~*~ ALASKA WATER & WASTEWATER sCALE: , . CONSULTANTS, lNG. 1" -- 40' PREPARED FOR: PHONE NUMBER: PAGE NUMBER: WILLIAM HURST .'345-7904 2 OF 4 ' SHENANDOAH HILLS SUBDIVISION; LOT 7 " '"" qh,~e~. ' '.~ ...... -" ~.~,~:~ DESIGN OF PROPOSED SEPTIC SYSTEM UPGRADE AdvanTex' Treatment System NOTE: JIM CROSS, ' P.E. HAS THE ,~w.~x ~,~ AX20 - Mode 1 a ~ ~ 40x94P°d --. INLET_.._ ~~ RISE TO THE iFILTER ABOVE IT. ,,30 INCH s'PvccouPuNC ~ . ~ II!lllll CLUED TO TANK ~ [ltlll~lllll~llllllElll~~! ! - :: I I I ~1111 INLET ~' SUDE SECTION "~ I ~ "' ~,.~ VAULT . /, III I, II I, II tl_llll s.[t. PRD~O~;/ N IFIB'E'RG[As~;'"TA,NK II1[ ii" f/I/ EpuMFFLpUENT BRIDCE [XCAVAIION--j ~~2~"~J [ I I J ! :J c..,.,~.,z..,-.,,, ff~.?; ~t.~0~ . co,su,..,-,,,-,-~.,,o. ,.T.S. ~ .... ~ .... ""':q'::~ ~'" ~q0~ DEB,'.RR RO~.D, SUFTE ~B o ,~NC~ORA~E. AK q~50.~ o PHONE Cq07)537-~lTq ' FAX (q07)'~58-~,~-6 ~,~,~. ~o,:: ,.o.~ ....~,: ~^~ .,..~,: ~..~...~ .... .2..~(:. ....... k .... .~l WILLIAM HURST (907) 545-7904 5 OF' 4 l~ ~ :.,[e~r~h'{ ~'/~. ~nes,~[: q ~'... ..' SHENANDOAH HILLS SUBDIVISlON~ LOT ? I~j,~ .~.~.J ..... WPE or WORK: '~'~ DETAIL DRAWING OF ADVANTEX TREATMENT UNIT THE DISTRIBUTION UNES ARE TO BE 1.25 INCH SCH  40 PVC WITH ~ INCH HOIFS SPACED 28 INCHES ON CENTER (12 HOLES PER LATERAL,~ 72 HOLES TOTAL). -~iOMT MTO · '[ :" I - BI [ I 12, I. I EI I ~1 I I - 60 FEET LONC ' / FINAL GRADE I-4. -20' To ToE o~- SLOPE -I / I ~' FOR F1LL OVER DRAINFIELD I / --0.5' OF EFFECTIVE / /---~NSULATION \ / / / / z--~N~ALL B~C~NG AND \ __-- ~ --._/ ~/ ~AKINO ,~ .REDED "S~X~i~G-~s-NEEDEo ~ '~ ...... ..,,.....,-....,..,...,. ..... ,-. '..',,,_';..'....-~.-,. ..'~::~.%....., -.~..,~;j..-;.-.;.~.: ~'.:'..~, 1 FOOT DEEP MAXIMUM. --m~l -- I FOOT DEEP MAXIMUM. EXCAVATION TO BE LIMITED TO I"-'~' 15 FEET WIDE ' I EXCAVATION TO BE UMITED TO THE REMOVAL OF' ORGANICS.-- ' / THE REMOVAL OF' ORGANICS. / THE DISTRIBUTION UNES ARE TO BE 1.25 INCH PVC WITH ~ INCH HOLES SPACED 28 INCHES ON / - CENTER (12 HOLES PER LATERAL, 72 HOLES TOTAL). 3/24/2003 c.J.G. ~/~x~.' AI~$KA WATER & WASTEWATER *~: ~'"'lq , CONSULTANTS, INC. '-'/I ........ ........... 6q01 DEBARR ROAD, SUITE 2B ° ANGHOI¥,GE. AK qqS0L · PHONE (q01)5~7-61?q · FAX (~01)3~8-~2L6 N·T,.S· ~.----, PREPARED FOR: PHONE NUMBER: PAGE NUMBER: ! ..... t ..... I ......... WILLIAM HURST (907) 345-7904 4 OF 4 [le:/ ~i~j~ess.: LEGAL DESCRIFTION: SHENANDOAH HILLS SUBDIVISION; LOT 7, I~b~'~".i, ~fPE OF WORK: DETAIL DRAWING OF DRAINFIELD UPGRADE WATER & WASTEWATER ~01 ~ ~. ~ ~ ~ ~ ~ ~ * ~ (~7~-61~ ~ F~ (~7~ · ~ ~.~,, ISOIL LOG - PERCO~TION TESTi PERFORMED FOR: WI~M HUR~ DA~: ~/14/200~ .~?.~. ............ ORGANICS ITEST HOLE ~1 I PAGE 1 OF 2 SOIL C~SSIFICATIONS ~_J SITE P~NI :~: GP HL ,,%. 5 ' ', DEPTH TO DATE ;~]J SC/SM GROUNDWATER ~  ~J[~~ SEEP ~ 9' ~/14/2005 DATE READING CLOCK NET TIHE WATER LEVEL NET DROP TIHE (HINUTES) READING (INCHES) ~/~ 7/2oo~ 1 2:~ ~ - 8' - m 2 ~:o~ 5o 5 UPPER BENCH ~ 5:01 - 6" - . ~:~ ~o ~ s/~' ~/~" 5 5:~1 - 6- - 6 ~:o~ ~o ~ ~/~" ~/~' 1B~ PERCOLATION RATE BO (HIN./INCH) PERC. HOLE DIA. 6 (INCHES) 19~ TEST RUN BETWEEN 1.0 FT. AND 2.0 FT. 20 ~ A FOUR HOUR PRESOAK WAS PERFORHED: ~ YES ~ NO SOILS LOGGED BY: ~ FISHER PERCOLATION TEST PERFORHED BY: MA~ FISHER COHHENTS: PERFORMED BY AK~C, INC. I, JEFFR~ A. GARNESS, CERTI~ THAT THIS ~ ~ERFORMED IN ACCORDANCE WITH A~ ~ATE AND MUNICIPAL GUIDEUNES IN E~EOT ON THIS DATE: I DEPTH TO DATE GROUNDWATER SEEP O 9' 3/14/2003 9.5' 3/17/2003 ~.5~ 13/24/2oo3 .... .9. ...... 6901 ~ ROAD, SUfT[ lB * [ ~ 99504 ' Pt40Nr'' (~07}..%37-8179 ' FAX: (007)338-3240 ° Wl~u~r..: ol~wwc.com I$OIL LOG - PERCOLATION TEE;TI ...... LEGAL DESCRIPTION: SHENANDOAH HILLS SUBDMSION; LOT 7 PERFORMED FOR: WiLUA~ HURST DATE: =/14/200:~ ITEST HOLE #~1 I PAGE 2 OF 2 I (/3 SOIL CLASSIFICATIONS 0 !~~ GP :~ ME ~-F- ' 'FRTTD~ GM CL <C GC OL 4-- 0 % o~ SW MH s_~" '. SPsM oHCH SEE SITE PLAN ca sc ON PAGE 1 OF 2 7-- 0 ~ DEPTH TO GROUNDWATER DATE ~o- © I, DATE READING CLOCK NET TIME WATER LEVEL NET DROP 11 -- TIME (MINUTES) READING (INCHES) ~ 3/~7/2003 1 2:29 - 6- _ 12-- LL I 2 2:59 30 6" O" LOWER 13..- 0 BENCH 3 2:59 - 6- - 4 3:29 30 6" O" 14-- 5 3:29 - 6- - LLJ 6 3:59 30 6" O" 15-- <C 1 6I ~ 18- PERCOLATION RATE >120+ (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) 19-- i TEST RUN BETWEEN 5.0 FT. AND 6.0 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: [] YES []No SOILS LOGGED BY: MAl'r FISHER PERCOLATION TEST PERFORMED BY: MATF FISHER COMMENTS: PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WFFH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: DEPTH TO GROUNDWATER DATE ALASKA WATER & WASTEWATER 4' CONSULTANTS, INC. E" ': .... : ......... ISOIL LOG - PERCO~TION TESTI ~; ~ ~:~ef~;~FX.~"' LEG~ BESCRIP~ON: SHE~DO~ HI~ SUBDNISION; LOT 7 ss~]" ~0~ '~'. iC~-7053 .." PERFORMED FOR: Wl~ HUR~ DATE: 3/14/2003 qh~e ".) / ...' f ORGANICS ITEST HOLE ~OlL C~SSIFICATIONS~ ~_JS~E  ~~~~~~ DEPTH TO DATE SC/SH ~ GROUNDWATER SEEP e 9' ~/~4/200~ 6' ~/~7/200~ ~' 5/24/200~ 10 I 11 DATE READING CLOCK NET TIME WATER LEVEL NET DROP TIHE (MINUTES) READING (INCHES) 12 3/17/2003 1 2:30 - 6- - 2 3:00 30 6" O" 13 3 3:00 - 6- - 4 3:30 30 6" O" 14 5 3:30 - 6- - 6 4:00 30 6" O" 15 16 17 18 PERCOLATION RATE >120+ (MIN./INCH) PERC. HOLE DIA. - (INCHES) 19 TEST RUN BETWEEN 4.0 FT, AND 5.0 FT. 2 A FOUR HOUR PRESOAK WAS PERFORHED: ~ YES ~ NO SOILS LOGGED BY: ~ FISHER PERCOLATION TEST PERFORMED BY: ~ RSHER COMMENTS: SM ~YER W~ FOUND TO BE 80 MIN/INCH IN TE~ HOLE ~1 PERFORMED BY A~C, INC. I, JEFFR~ A. GARNESS, CER~ T~T THIS W~ PE~FORMED IN ACCORDANCE Wl~ A~ ~ATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: DEPTH TO DATE GROUNDWATER SEEP O 9' 3/14/2003 6' i3/17/2003 G' 3/24/2003 7, LOT TALUS BLOCK 7 WEST ]LOCK 7, WEST 7, LOT ~E'FRC WEST ~CK 7. LOT ~OPOSED SE::P~( (SEE DES~¢N ~SEP'nC LOT HILLS LOT 8 IHOLDING TANK SHENANDOAH HILLS S/D; LOT 9 ~SHALLOW LOT 2 6qOI DEBARR RO PREPARED WlLLIA~ SHENA TYPE SITE P AK qqSO& ' PHONE (q07)557-6170 ' FAX (q07)5~, PHONE NUMBER: 545-7904 tDIVlSlON; LOT 7 ~TIC SYTEM UPGRAD )RAWN BY: SCALE.: 100' 5'H~tVt~tvPO~l¥ /.{/Lz5 'L"oT 7 .... ' DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION .- ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME [PHONE · ~UPGRADE -- I Well I Absorption area Dwelling PERMIT NO. DISTANCE TO: I I ~ z Manufacturer Material No. of compartments  Liq. capacity in gallons IF HOME.DE: Inside length Width Liquid depth ~ ~ DISTANCE TO: Well Dwelling PERMIT NO. O ~ ~ Manufacturer Material Liquid capacity in gallons ~ ~ DISTANCE TO, Well /m+ Foundation Nearest lot I~ ~ PE~~t ~ ~ No. of lines O~nches ~ ~ Length of sachS' Total length ~ ' Trench widt~ Distance bet~en Iin~ ~ ~ Top of tile to finish grade ~ , Material beneat~ile (~ nches T°ta' effective ab2:~~ Length Width Depth PERMIT NO. ~ ~ Type of crib Crib diameter Crib depth Total effective absorption area m Well Building foundation Nearest lot line ~ DISTANCE TO: ~ Class Depth Driller Distance to lot line PERMIT NO. ~ Building foundation Sewer line Septic tank Absorption area(s) ~ DISTANCE TO: OTHER SOIL TEST RATI~ APPROVED DATE LEGAL 72~313 (Rev. 3/78) ./ _ MUNICIPALITY OF ANCHORAGE_. Departmen,~,f Health and Environment~'~Protection 825 L Street, Anchorage, AK. 99501 .~ 264-4720 ~ ~.~o75-9' * '"' HANDWRITTEN PERMIT * * ~-- Permit ~ ~ ~C-4,G~i~]~-OR ON-SITE SEWER PERMIT Applicant: ~; ~..n..~_jq Mailing Address: kY)! Location: 7-/~Y%; ~C0 ~-~ ~-~ Phone Number: Legal Description: -~Z~~ ~K L~7 / Lot Size: Type of Soil Absorption System Is: Trench: Drainfield: Seepage Bed: ~ Holding Tank Maxi~num Number of Bedrooms: ~ Soil Rating (sq. ft/br) The Required Size of the Soil Absorption System Is: DEPTH ~'' ~:1 I LENGTH .5'-'~' GRAVEL DEPTH · WIDTH' ,,,.~7 The length dimension is the length(in feet) of the trench or drainfield. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(in feet). There is no set width for trenches. The gravel depth is the minimu~ depth of gravel between the outfall ~ipe and the bottom of the excavation(in feet). ~ ~ REQUIRED SEPTIC(HOLDING) TANK SIZE = ' /OOf2) GALLONS ~ * Permit applicant has the responsibility to inform this'department during the installation inspections of any wells adjacent to this property and the number of residences that the well will serve. · ~ ~ ~ TN0(2) INSPECTIONS ARE REQUIRED ~ * ~ Backfilling of any system without final inspection.and approval by this departm~ will be subject to prosecution. Minimum distance between a well and any on-site sewage disposal system is 100 fE for a private well or 150 to 200 feet from a public well depending upon the typ~ of public well. Minimum'distance from a private well to a private sewer line is 25 feet and to a community sewer line is 75 feet. Well logs are required and must be returned to this department within 30 days of the well completion. Other requirements may apply. Specifications and construction diagrams are available to insure proper installation. * * * PERMIT EXPIRES DECEMBER 31., I certify that: (1) I am familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage. (2) I will 'install the system in accordance with codes. (3) I understand that the on-site sewer system may require enlargement if the r~si~nce is remodeled to inc'lude more that 3.bedrooms. Signed: '~ ~~ Issued by: Applicant Date: 3 SWP/024 (1/81) MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG -- PERCOLATION TEST SOILS LOG PERCOLATION TEST SLOPE ', SITE PLAN I / I/ILl N I III I /1/1~1 I N II/ . !,1 I~ I I I I I 1 10 11 ~ 12 13 14 15 16 18 20 72-008 (6/79) WAS GROUND WATER ENCOUNTERED?. IF YES, AT WHAT DEPTH? ' Gross Net Depth to Net Reading Date Time Time Water Drop ~.H~o CJ,I~.~5 n:~ . . ~,o / Il:qb, IOfn/~ ,'.t? ,0.~ PERCOLATION RATE TEST RUN BETWEEN CERTIFIED BY: 5-7 '~"'"' ~ FT AND {minutes/inch) .'~ .S- FT ,.. ~':..Y~X , /;':.? - ~'DATE:q' /7'?,.¢ w~UNICIPALITY OF ANCHORAGE ~ Heal~ land Environmental Protec~ ~n Fourth Floor West 825 L Street Anchorage, Alaska 99501 264-4720 INSP,.ECTION REpORT"ON-SITE SEWAGE DISPOSAL SYSTEM SEPTIC TANK: FROM WELL _/0~;; . MANUFACTURER. ~ MATERIAL COMPARTMENTS INSIDE LENGTH. INSIDE WIDTH LIQUID DEPTH LIQUID CAPACITY/"6:f~'~:2 GALLONS. TILE DRAIN FIELD: DISTANCE FROM WELL /~O-& .FOUNDATION /0 f';/-~NEARESTLOT LINE ii ~~ / TOTALoF LINELENGTH~' ?-~ f ~ of Lines DISTANCE BETWEEN LINES TRENCH WIDTH~ IN. TOTAL EFFECTIVE ABSORPTION AREA DEPTH: TOP OF TILE TO FINISH GRADE SQ. FT. LENGTH OF EACH LINE DEPTH Of FILTER MATERIAL BENEATH TILE IN. ABOVE TILE IN. SEEPAGE Pit: DIAMETER ~ OR WIDTH , Log Crib Rings Crib Size:J DIAMETER . BUILDING FOUNDATION__, NEAREST LOT LINE ,, LENGTH ., DEPTH , DEPTH , . DISTANCE FROM: WELL ,. TOTAL EFF~'CTIVE ABSORPTION AREA (WALL AREA) SQ. FT. Well / Class:/n~, Depth: Well Distance To: Lot Line Bldg: Sewer:Line: Pipe Materials: # of Bedrooms: Installer: !,hia Remarks: DEF'RRI'MENT OF~qEALTH AND ENVIRONMENI"AL F'?i~FECI']IJN ~ ~ 825 'L' _.'I"REEI'.. ~N,ZH'DR~GE, HK. 995 ..... F'ERMIT NO.~ ( 778~ ) · · APPLICANT LOCATION LEGAL DAVE DEAN'S CONSTRUCTIO ~R~NNRNDORH PLACE L7 SHENNRNDORH HILLS SUBD BOX il5 CHICKALOON ST EBGLWE R '694-9387 LOT SIZE 65646 SQUARE FEET TYPE OF SOIL ABSORBTION SYSTEM IS: TRENCH MA>',ID1UM NUMBER OF BEDROOMS : 3 SOIL RATING TIlE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS: THE LENGTH DIMENSION IS I'HE LENGTH (IN FEET) OF- THE I'RENCH OR DRAINFIELD. THE DEPI'H OF A TRENCH OR PII' IS I'HE DISTANCE BETWEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE EXCAVATION (IN FEET). ]'HERE IS NO SET WIDTH FOR TRENCHES. ]'HE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE 8ND THE BOTTOf'I OF THE EXCAVATION (IN FEET). . I';-:EL;!LI I RI----D StSF'I- I L--- TI~I'-.I K S I ZE= :L000 t-~FILLCxI'-IS I=-I~.~.~cZFiI__~E PUl:iD, l-i- F-~F'-Y I C~I'-,i PACKAGE PLHNT MAY BE INSTALLED AT THE PERMITI'EE"-'~ OPTION SUBJECT TO THE FOLLOWINA CONDII-IONS: i. EITHER A CLASS I OR I I NSF APPROVED PL~NT MAY BE INSTALLED. 2. ~ CONTINUOUS MAINTENANC~ RGF,'EEMENT IS REQUIRED. IF ~ blAINTEN~NCE AGREEMENI' IS NOT KEPT CURRENT At'OD MAY BE REQUIRED TO ENLARGE THE SOIL ABSORPTION SAt'STEM AND/OR YOU MAY BE SUBJECT TO PROSECUTION. l'-I_..Ir~ ,-f. 2 ) I I'-,ISF'EC:-I- I ~2Jl'-,l_q . I~:E RISI_'_--!I_I I F-:ED BACKFILLING 0~ ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCE BETWEEN A WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS 100 FEEl' FOR A PRIVATE WELL OR 200 FEET FOR A PUBLIC WELL. OIHER REQUIREMENTS MAY APPLY. SPECIFICAI'IONS 8ND CONSTRUCTION DIAGRAMS ARE AVAILABLE .TO INSURE PROPER INSI'ALLATION. F'Ei;.' r-11 T E~<P I I?..ES DEI~Et-IE:EF.' 3:1_.. ::!..9-77 I CERTIFY THAI' l: I Arq FAMILIAR WII'H THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET FORTH BY THE MUNICIPALITY OF,ANCHORAGE. 2: I WILL INS'fALL THE SAt'STEM iN ACCORDANCE WITH 'THE CODES. ~: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF' ]"HE RESIDENCE IS REMODELED TO INCLUDE MORE THAN -~ BEDROOMS. V3. 0 Test Hole 91 Lot 4 pepth in Feet From To 0.0' - 2.0' 2.0' - 2.5' 2.5' - 7.5' 7.5' - 15.0' 15.0' - 16.0' 16.0' - 21.0' Table A WO %A18217 Date: 9-8-77 Logged By: T. Barber Soil Description F-4, brown Gravelly ~andy Silt, ML, wet, soft, backfill. 'F-4, brown Topsoil, with undecayed vegetative material. F-4, brown Gravelly ~andy Silt, ML, damp, stiff to hard. F-4, brown Sandy Silt, ML, damp, stiff. F-4, brown Gravelly Sandy Silt, ML, damp, stiff to hard, occasional'cobbles. NFS, brown Sand, SP, damp. Bottom of Test Hole: Frost Line: Free Water Level: 21.0' None Observed None Observed while drilling Test Hole #2 Lot 7 Table A WO ~A18217 Date: 9-8-77 Logged By: T. Barber pepth in Feet From To 0.0' - 0.2' 0.2' - 15.0' 15.0' - 20.0' Soil Description F-4, brown Topsoil. F-4, brown Gravelly Sandy Silt, SM, damp, stiff to hard, occasional cobbles. F-4, brown ~andy Silt, }~, damp, stiff. Bottom of Test Hole: Frost Line: Free Water Level: 20.0' None Observed None Observed while drilling 4040 "B" STREET, ANCHORAGE, ALASKA 99503 PHONE: 907-279-2581 September 13, 1977 W.O. #A18217 Grid %2736 Dave Deans Construction Box 115 ChickaloOn Street Eagle River, Anchorage, 99577 Subject: Gentlemen: Subsurface Investigation for Suitability of On-Site Sewer, Lots 4 and 7, Shanendoh Hills Subdivision Transmitted herein in accordance with your instructions are the results of the above referenced investigation as performed by us on September 8, 1977. The scope of this project is the investigation for suitability Of an on-site sewerage system. Included ih this.transmittal are: Test Hole Location Sketch Test Hole Logs Explanatory Information Figure 1 Table A Sheets 1-3 The exploration was conducted using a continuous flight solid stem auger. The rig is owned and operated by Denali Drilling, Inc. .Drilling was supervised, the test hole logged and percolation test~performed by Mr. Terry Barber, geologist for Alaska Testlab. The logs of the test holes are included as Table A of this report. In interpreting the logs, it'would be helpful to utilize the explanatory information contained in Sheets 1-3 of the ~eport. When drilling wa~ completed a 3/4" slotted PVC pipe was inserted in the hole to aid in determining the free water level. For the percolation test, the test hole was filled with water and left overnight, to saturate. On returning the next day, the'hole was refilled with water and the drop ~n the water level carefully monitored over the next 60 minutes, This procedure is 'not a standardized percolation test, however, we uncterstand that the Municipality of Anchorage, Depar'cment of Public Health and Environmental Protection prefers 4:ests performed in this manner to evaluate a site for a proposed on-site sewerage system. · Dave Dean Construe'ion September 13, 1977 Page 2 Using the above test, the observed minimum percolation rate for test hole #1 (Lot 4) was 5.7 minutes/inch. This requires a seepage pit absorptive area of 135 square feet/bedroom. The observed minimum percolation rate for test hole #2 (Lot 7) was 5.0 minutes/inch. This requires a seepage pit absorp- tive area of 325 square feet/bedroom. ~ The percolation'rates obtained are higher than would normally be expected for the soil types encountered. These fine grain soils, though they may percolate, have a tendency to plug. It may, therefore, be prudent to use a more conserva- tive design value of about l~square feet per bedroom for both lots. No water table was observed during drilling on either .test hole. It should be noted though, that the free water level normally fluctuates seasonally and with precipitation. We hope this report meets your present needs. If we can be of further service, please feel. free to contact us. Very sincerely, ALASKA TESTLAB JRS: rb Enclosures ~P~ROVED .. ~lefVin R. Nichols, P.E. Laboratory Manager Finegrained ~oils ] Coarse-~ained ~oils More than half of material is smaller] More tl~n half of mater~] is SiltS~uMandumitC~ys SUcsfiqu~a~UmitC~Ya ~. (For ~sua] claffication, the ~ in. size may be ugd wearer than less than 50~. equivalent to the No. 4 sie~ fines Clean ~s fines Clean ~ (aeprecbble (lilfle or no (appreciable g amount of ~mes) amount of g ~mes) fines) ~ ~ ~ ~'~ = . ~ 200 de~ ~ze) co~ ~ained taus are ch~i~ed [1111111111111111111111 ] ;s:~:=- ~ =~:,.=.* . SON WELL DRILLIk% 1305 W. 45TH STREET ANCHORAGE. ALASKA 99503 PHONE 272-9343 DRILLING LOG Location (address of: T,,,~..~n~ip, Range, Section, if,J~own; distance Use of Well main road Size of casing (r {' ' " Depth o'f Hole [o '~) ~; Ceet Static water level ,"~ O ft. (above) ((~_o~) land Screen ( ); Perforated ( ). Cased to (-"'~ ~' feet surface. Finish of well (cheek one) open end ( Describe screen or perforation. Well pumping test at I~ gallons per of drawdown from static level. (hour) ~ for. ~ hours with z~ ' Date of completion ~ -"~C ~4 - tq~J "~ WELL LOG Depth in feet from ground surface Give details of formations penetrated, size of material, color and hardness ft. TO TO TO TO TO_ TO TO TO TO_ t ~1 LI r-~ i' i-: ~: i=- F~ I_ I T ~" g--~ I~ ~ ~ ~ ~ ~ F~ ~ E .7 DEPARTMENT ~' HEALTH AND ENVIRONMENTAL OTECI'ION / 825 ~L.,'STREET, ANCHORAGE, AK. 99~g:l. 279-2511 NI~LI_ PERI~I · 1- PERMIT.NO. ( 77769 APPLICANT LOCATION LEGAL DAVE DEANS BOX lq.5 CHICKALOON Sl' E. SHENANDOAH STREET LOT 7 SHENANDOAH HILLS SUB LOT SIZE R. 694938? 65340 SQUARE FEET MINIr. IIJM DISTANCE BETWEEN A NELL AND ANN' ON-SITE ~EWAG~-~iISPi']SAL SYSTEM IS 100 FEET FOR A PRIVATE WELL OR 200 FEET FOR A PUBLIu ~m. - WELL LOGS ARE REQUIRED AND MUST BE RETURNED TO THE DEPARTMENT NITHIN 30 DAN'S OF THE WELL COMPLETION. OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS 8RE AVAILABLE TO INSURE PROPER INSTALLATION. PEa:h11 T EXI:' I RES g-',EI2Et1BER --~i. i97'? I CERTIFY ]'HAl' · ~' I Ar'l FAHILI~R NITH THE REQUIREMENTS FOR ON-SITE SENERS AND WELLS 8S SET P-OATH 8Y THE MUNICIPALITY OF ANCHORAGE. 2- I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE coDEs. SIGNED' APPLICANT DAVE DEANS V.~. 0 ��l�UHMPA UT OF HCHORQGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax. 907-343-7997 Certificate of On -Site Systems Approval Parcel 1. D. 015-212-44-000 Legal description SHENANDOAHHILLS LT 7 Expiration Date: Site address 12030 SHENANDOAH RD Anchorage AK 99516 10/24/2023 Current property owner(s) KLUG MARILYN J SURVIVORS TRUST KLUG MARILYN J / TRUSTEE X The On-site system(s) is/are approved for 3 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or advisories: lZ Original Certificate Date: 7/24/2023 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other COSA ApprovaIjune 2022 MUNICIPALITY OF ANCHORAGE 0., Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application' 1. GENERAL INFORMATION Parcel I.D. 015-212-44 Complete legal description SHENANDOAH HILLS LOT 7 Location (site address) 12030 SHENANDOAH ROAD ANCHORAGE, AK 99516 Current property owner(s) KLUG MARIYLYN SURVIVORS TRUST Day phone 2. ON-SITE SYSTEMS SIZED FOR 3 BEDROOMS 3. TYPE OF WATER SUPPLY: ® Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ❑ Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: ® Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑ Steel ❑ Plastic ❑ Concrete ® Fiberglass Age _20_ - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ® AWWTS ® Bed ❑ Deep Trench ❑ Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: Distance: By applying for this entitlement, this property is subject to inspection by municipal On-site staff to verify the accuracy of the information provided. COSA Fee $ _ ,50 Date of Payment Waiver Fee $ Date of Payment COSA # DSG2 3 -�) Waiver # COSA Application.doc COSA Checklist.docx COSA Checklist Legal Description: SHENANDOAH HILLS LOT 7 Parcel ID: 015-212-44 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____ A. WELL DATA Well log is filed with Onsite (or attached) Date drilled 5/12/2005 Total depth 86 ft Cased to 86 ft Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) 24 in. Date of flow test for COSA 7/5/2023 Static water level at beginning of test 18 ft. Well production at time of test 5+ gpm Water storage tank volume NA gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate 2.74 mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date 7/5/23 Comments SULLIVAN INSTALLED NEW WELL PUMP B. TANK DATA Measured operating fluid level in septic tank NA Date of pumping 5/10/23 – SEE AX MAINT Required maintenance completed, if AWWTS Comments: PER ANCH TANK – VERY LITTLE USE FOR 5+ YEARS. C. LIFT STATION Required maintenance completed Age of lift station 20 years Lift station material FIBERGLASS Comments: SEE AX MAINT REPORT D. ABSORPTION FIELD DATA Which system tested (date installed) 4/7/2003 ALL standpipes present per record drawing Total measured depth from grade 3.9 ft (max) Measured depth to pipe invert from grade ft (min) N/A – pressurized field. Per record drawings, field is insulated. Monitor tubes (MT) go to bottom of effective. (ED) If not, state depth into effective Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced 2000 gallons 7/3/23 date Any rejuvenation treatment (past 12 months) N If yes, enter date Adequacy test date 7/5/2023 Results Pass Fluid depth prior to test 0 in Water added 450 gal New fluid depth 1 in Elapsed time 5 min Final fluid depth 0 in Absorption rate 450 gpd FIELD STATUS – POST RECOVERY Effective depth (per record drawings) 7.2 in (MOA 0.6’ ED) Effective depth used 0 in Effective depth (ED) remaining 7.2 in Comments/Deficiencies: Approximate total measured depths from existing grade. ED per elevation measured shots & appears approximate. COSA Checklist.docx E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’ Yes if No ft Absorption Field on Lot > 100’ Yes if No ft Neighboring Absorption Fields > 100’ Yes if No ft Community Sewer Main > 75’ Yes if No ft Community Sewer Manhole/Cleanout > 100’ Yes if No ft Private Sewer/Septic Line > 25’ Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’ Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft N/A – Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10’ Yes if No * ft Tank to Property Line > 5’ Yes if No ft Field to Property Line > 10’ Yes if No ft Water Main > 10’ Yes if No ft Water Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft Wells on Adjacent Lots: Private Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No ft If tank or field is under driveway comment below F. ENGINEER’S COMMENTS *Advantex tank system & lift station / vault is 5’+ from foundation per code at install. G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm FIRST WATER CONSULTING Phone 907-350-9566 Engineer’s Printed Name CURTIS HUFFMAN, PE Date 7/15/2023 Comments: This investigation was completed in compliance with MOA guidelines, regulations, and best industry practices / methods. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes in land use, local soil characteristics, groundwater levels that may fluctuate during the year, quality of construction (workmanship & materials), the water usage of the family being served by the system and maintenance. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, any or NO estimate of how long a system will function satisfactory for current or future occupants or guarantee that no unseen encroachments, deficiencies or discrepancies exist can be given by First Water Consulting & 7/15/23 To: Page: 3 of 4 2023-05-11 00:58:07 GMT 19073086608 �. 45 5 mans a ■■ ■■ ■■■ on so on no ■an an e �■ BOB ■■■■■■■ ■nna■ ■ ■ mama■ ■ ® o - r I TRINITIMUFMAIRY21=9 From: Wes Anderson AnchorageTank 907-272-3543 Property 0w.e ackingtl Marilyn Kiug A+Home Services Tech ......__ ContaC Phone — SiteAddress 12030 Shenandoah Road, Anchorage AK 99516 907-346-212!:3 nx. she io# cnunh lox Paau RTU 4fuL # care of Lasi Inspevbon AX -101455 SW030057 201271 rRTU101469 05113/2022 Retrieve O&M Info Daily flow - — Recirc ratio Timer settings: - perform Field Sampling/Observations NTL (15 t NTUs) pH i6-9) DO (2-6) Odor of Sample " Typical i_`vusty r_, Earthy LIMoidy Non -typical [-]sulfide (.._.Cab`b�a�ge C Decay Oily film in PVU ^Yes L%No Foam in tank [;Yes !No Check Control Panel Recirc.Amp% �senarge Amps Audible and visual alarms _NOK Dial tone (telemetry only) Dyes �.-_�No Inspect/Clean Pump System - Odor: Xej Normal -.Inspect Bipmah Normal Clean -Risedud .......... ...............^ Previous Current Splice Box [2�ndCompartment Be Float Cords ... .. . Floats . _ .,, , Pump .... .... Biotube- Filter.. ... .. Biota to Pump Vault ...... .., Recirculating Splitter Valve....... _ Comments Measure Sludge/Scum Scum Inspect/Clean AdvanTex Filter Clean Odor: Xej Normal I� ;Pungent Bipmah Normal Compartment Cu nk Previous Current Previous [2�ndCompartment Be Previous Current Previous Float cords t5l Inspect/Clean AdvanTex Filter Clean Odor: Xej Normal I� ;Pungent Bipmah Normal L' Excessive I Bridging/Ponding: one/Mncr [ Excessive Inspect/Clean Discharge Pump System Inspect Riser/ id Splice Box Is Float cords t5l Inspect. Clean Laterals/Orifices _, Pod Bottom Intake Vent "' Inspect Clean Floats4"w Pump inspect/Service Other System Components inspect Clean inspect Cie -an Disinfection Equipment �,. Dispersal LateraistOnfices 1 S Observations._ *•' - Additional Services Rendered ❑ Cleaned textile Sheets? Replaced UV items? �_ . Replaced/Used other items? Parts Used: W = Warranty, B = Billable (✓ appropriate selection) ui n It,em Number Description Final/Safely Inspection + t- RSV reinstalled _N`Lkds bolted on '`"�fi' anifold .reconnected; flush valves. closed ' control panel reactivated Summary/Recommendations ~System performing; no further action needed ❑ Tank needs pumping EJ call for service EJ Other? ____ .......__ - ��r Signature'"Z;�'� ---- — — Date Fax completed form to 1-866-384-7404 www.sullivanwaterwells.com Pump Installation Log Well Drilling Permit Number: SW Date of Issue Parcel Identification Number: Legal Description Property Owner Name & Address Shenandoah Hills Lot 7 Brent Western 12030 Shenandoah Road Pump Installation Date: 6-29-23 Pump Intake Depth Below Top of Well Casing: 70 feet Pump manufacturer’s Name: F&W Pump Model: 4F11P05301S Pump Size: 1/2 hp Pitless Adapter Burial Depth: 10 feet Pitless Adapter Installer: Unknown Disinfected Upon Completion? yes no Method of Disinfection: Chlorine 50 PPM Comments: Pitless Manufacturer: Unknown Pump Installers Name: Sullivan Water Wells Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. ,Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage; AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 015-212-44 1. GENERAL INFORMATION Expiration Date: ~--~ -- ///'- O ~ Complete legal description SHENANDOAH HILLS SUBDIVISION; LOT 7 Location (site address or directions) 12030 SHENANDOAH ROAD * ANCHORAGE, AK * 99516 Current Property owner(s) Mailing address Lending agency . Mailing address Real Estate Agent Mailing address WILLIAM HURST 12030 SHENANDOAH ROAD * Day phone, 345-7904 ANCHORAGE, AK * 99516 Day phone Day phone Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3 3. TYPE OF WATER SUPPLY: Individual Well I · Individual Water Storage r-~ Community Class Well [--I Public Water System ]--] TYpE OF WASTEWATER DISPOSAL: Individual On-site I Individual Holding tank [~] Community On-site [--] Public Sewer I--] The Municipality of Anchorage Development Services Department (DSD) Issues Cedificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. CertifiCates of Health Authority Approval are required for the transfer of title (except between spouses) for propedies served bY a single-family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Cedificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's ~ work. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I ve#fy that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate 'for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, LTD. Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Engineer's Comments: In conducting this evaluation, GEG, Ltd. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation " distances measured to readily identifiable features. The operational life of ali wells and septic systems depend on the loc, al soils condition, groundwater levels that may fluctuate during the year, and the water usage, of the family being served by the system. These conditions are outside the control of the eva/uator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachrnents. GEG, Ltd can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. Phone 357-6179 5. DSD SIGNATURE Approved for bedrooms. Disapproved. Conditional approva! for 3 bedrooms, with the fllowing stipulations: At the time of title transfer, the new property owner shall sign the attached maintenance agreement which shall be returned to this office beforeafi unconditional approval is issued. Attachments: HAA Checklist Septic System Advisory Well Flow Advisory Manitenance Agreements Supplemental Engineer's Reort Other By: ~,,.--, (Rev. 12./01) Original Certificate Date: Le~a~,l D~ ci'iption:", A. WELL DATA Bo Municipality of Anchorage DeveloPment ServiCes Department - Building Safety Division On-Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, 'AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 HEALTH AUTHORITY APPROVAL CHECKJi T ; SHENANDOAH HILLS SUBDIVISION; 'LOT 7 iPl~'rcel · W~ll type· PRIVATE ' If A, B, Or C provide PwSIb# ' N/A Da~e~',c~pleted '9/2/1977: sanitary seal (Y/N) ~;ES · Total depthr :64 ff. '. casedto - 6~t- fi: .'. "'~';~i ' FROM WELL LOG Date (~f test ' 9/2~Y1977 static water level 30 ft. . '.~ Well tion 18 ' g,p.m. .... AMPLE WATI RESULTS: uoutorm ~. ~ colonies/100 mi. ArSehic: !N/A mg./L. SEPTIC/HOLDING TANK DATA ..... : Tar~l~ .T~e/Material FIBERGLAss~ADVANTEx ' ,; :!" Tan~ si~i 1500 gal. : i Numberer Compartments 2 Founda[ion cleanout (Y/N) 'YES ' Depression over'tank (Y/N) NO 015-212-44 WelllLog (Y/N) Wires proPerly ~protected (Y/N) Casinghe!ghi,~ab°vegr°und).,. AT INSPECTION 3/12/2003 - 32iii ff. I ,3.0 i~r YES .g.p.m. ia:Jlria ~"'--~'~ colonies/100 YES 12+ -in. NiJrate /,~'?)O mg./L. Date of sample: :3/1/2004 Other : Collect,ed ~y: GEG~ Ltd. Date in§tailed ,' 4/4-7/2003 CleanO~ts IY/N) YES High w,'ate'r'alarm (Y/N) YES mi. Daie of ~n-;ping NEW Pumper L.: '~'· Date !nstalled .4/4-7/2003 Soil rating ~r ft~/bdrm)**0.5 -S type BED Le~ih i~::.'60 ;fl · Width' - ~5: ~ ff Gravel below Pipe 0.6 Totaldepth 3.0+ ft. Eft. absorption area 900+ ft ~Monitoring tube YES Depression over field NO Dare'of adequacy test r~W.b'l'blEM ;' . : -:Results (Pass/Fail) PASS' i , ' · :For 3 bedrooms Fluid depth in absorption field before test ; · in; : ::Water added gal New death------in Elapsed ~Time: min. : Final fluid de : '.' ' Absorption r~te >= . a ~ d ~atment (past.12 mo.) (YIN & type)' ;: . : - If yes, give date · * THIS IS AN ADVANTEX TREATMENT SYSTEM :" i' ]! ; LIFT STATION Date installed "Pump on" level at E. SEPARATION DISTANCES Pump off' ~n. High water alarm level at ~ · in. Cycles tested Meets alarm & circuit requirements? SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot Absorption field on lot Public sewer main Sewer/septic serVice line 100'+ 100'+ . 25'+ On adjacent lots On adjacent lots Public sewer manhole/cleanout Holding tank SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: ~i. Building foundation 5'+ Property line. 5'+ :Absorption field · Water main N//A Water service line 10'.1. Surface water 100'-t- 100'+ 75'+ ,- ' 100'.1. Property line 1 O'-t- Water service line 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ ..· .. '. i. SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:' . ... Building foundation 10'+ Surface water 100'+ Wells on adjacent lots. 100'-t- F. COMMENTS .... ~ G. 'ENGINEER'S CERTIFICATION Water main .. N//A Driveway, parking/vehicle ~torage 10'+ I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA HAA guidelines in effect on this date. Engineer's Pri/~ted/Name Date~ JEFFREY. A. GARNESS HAAFee$ [-~ ~"~ Date of Payment Receipt Number Ur waiver Fee $ '~ Date of P~,m~nt !'' Receipt Number I, (~ , , N 89'57'45'W 272.63' ~ - %- ," - - ';;[,.TG.';.,~[~'~,,~.~ ........................... %,,, SINGLE FAMtLY IRAMC HOUSE REST HOLE pLACE 3-- 5--04; 2:37PM; ;907 5615301 # 2/ 7 :GS Ref.# :lient Name ?roject NameJ# :iient Sample ID ~[atrix 1041043001 Gamess Engineering Group, Ltd. NA Shenondoah Hills Lot 7 Drinking Water All Dates/Times are Alaska Standard Time Printed Date/Time 03/05/2004 9:56 Collected Date/Time 03/01/'2004 10:49 Received Date/Time 03/02/2004 15:00 Technical Director~ Stephen C. Ede Released By v,~ ~.~ ampleRem~ks: Results PQL UnRs Method Allowable Prep Analysis Container ID Limits Dale Date In[t 'aters Department Nitrate-N '4 crobiology Laboratory Total Coliform 1.30 0.100 mg/L EPA 300.0 col/100mL SMI8 9222B B (<= I O) ^. 03/02/0~ 03/02/04 JIB DKC ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT MEMORANDUM OF UNDERSTANDING BETWEEN MUNICIPALITY OF ANCHORAGE THIS MEMORANDUM OF UNDERSTANDING made and entered into as of this day'of ~/'z¢ 20t~q, by and between /~,q,~/~/q ,7- ]<l~]. , herein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY." In (AWWTS), described as consideration of the mutual covenants contained herein, the parties to this Memorandum of Understanding agree as follows: 1. ADVANCED WASTEWATER TREATMENT SYSTEMS. Municipality grants permission to Owner to utilize and operate an Advanced Wastewater Treatment System _/)/~ 1/~ ~ 7'"E~ ~loeated at ]-.o~t' 7 -~']1 e~/n a.~ ~oec~ Anchorage, Alaska. ~9n(/]c o v, e,q.~. //31<. q qJ"l ~ 2. Definitions. Ao Alteration. Any change to the design or function of an AWWTS that includes the installation or removal of any parts, components or pieces not included, in the original construction permit and design. Prior to performing any alterations to an AWWTS the owner must obtain a Wastewater Disposal System Construction Permit from the Municipality pursuant to Anchorage Municipal Code (hereinafter, "AMC") 15.65 Certificate of On-Site Systems Approval. An approval by the Municipality of existing water and wastewater disposal systems given at the time of property sale and title transfer in accordance with AMC Page 1 of 5 15.65. These approvals certify tl/at the systems are adequate for the homes that they support and meet the codes that were in place at the time of system construction. C. Damage. Any man-made or natural change in a system that would inhibit the system from performing as designed. D. Maintenance and Repair. The scheduled and as needed replacement of existing parts, components and pieces of an AWWTS that were included in the original design which would allow the AWWTS to continue to perform as designed. E. Permit (Construction). An On-Site Wastewater Disposal System Construction Permit as defined by AMC 15.65. F. Permit (Operating). An Advanced Wastewater Treatment System Operating Permit. An annual permit, issued by the Municipality, that allows the Owner to operate an AWWTS, upon meeting all requirements of this agreement, the conditions of the Operating Permit, the requirements of the On-Site Wastewater System Construction Permit and all relevant provisions of AMC 15.65. 3. Fee. Owner shall pay to Municipality an annual fee of ~ ~'~ 0 ($-~--.00), payable on or before the issuance of the operating permit and annually thereafter. The annual fee is due on or before the anniversary date of the approval by the Municipality of installed system. Page 2 of 5 4. Term. The term of this Memorandum of Understanding shall be for the life of the AWWTS. The term begins on the date of approval by the Municipality of the installed system and shall continue while the AWWTS system is in use or operational or until the property is sold or title is transferred by owner and a new certificate of on site approval is issued to the new owner or transferee of the property. 5. . Alterations, Installation and Removal of Additional Equipment. Owner agrees not to make any alterations, removal of parts or additions to the AWWTS without a Construction Permit from the Municipality. 6. Maintenance and Repairs. A. Throughout the term of this Memorandum of Understanding, the Owner shall maintain AWWTS in good repair. In addition, it shall be the responsibility of the Owner during the term of this Memorandum of Understanding, and any extensions or renewals thereof, at the owner's sole expense, to pay for'any and all: (1) repair(s), (2) maintenance, (3) adjustment(s), (4) replacement costs, and (5) inspection costs. Further, owner agrees to comply with all applicable ordinances, laws, regulations, rules and orders for the AWWTS. B. Owner agrees to provide the Municipality a written schedule of routine maintenance and repairs which have been performed on the system pursuant to the terms and conditions contained in the Owner's AWWTS Operating Permit. This schedule shall be submitted to the Municipality annually upon the renewal of the permit. The schedule of maintenance and repair contained in the Owner's AWWTS Operating Permit is: Page 3 of 5 Ce AWWTS are codified in AMC 14.60. D. Owner agrees that only Municipality will inspect and make any alterations to the systems. Owner acknowledges that the fine schedule for failing to maintain and repair an maintenance, repair personnel certified by the necessary maintenance, repairs or permitted E. Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS upon 24 hours written notice. F. Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On-Site Systems Approval. .G. Owner agrees that the relevant provisions of the standard specification guidebook for AWWTS is the governing professional guidelines for the construction, maintenance and repair of the Owner's AWWTS. 7. Nonwaiver. The failure of either party at any time tO enforce a provision of this Memorandum of Understanding shall in no way constitute a waiver of the provisions, nor in any way affect the validity of this Memorandum of Understanding or any part hereof, or the right of such party thereafter to enforce each and every provision hereof. 8. Amendment. A. This Memorandum of Understanding shall only be amended, modified or changed by a writing, executed by authorized representatives of the parties, with the same formality as this Memorandum of Understanding was executed and such writing shall be attached to this Memorandum of Understanding as an amendment. Page 4 of 5 conditions of this contract, the only authorized representatives of the parties are: For the purposes of any amendment modification or change to the terms and Purchasing Officer C. Any attempt to amend, modify, or change this contract by either an unauthorized representative or unauthorized means shall be void. 9. Jurisdiction: Choice of Law. Any civil action arising from this Memorandum of Understanding shall be brought in the 'Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Memorandum of Understanding. I0. Severability. Any provisions of this Memorandum of Understanding decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Memorandum of Understanding. OWNER: Date:.¢~f~, STATE OF ALASKA MUNICIPALITY: Title: THIRD JUDICIAL DISTRICT ) /, A The forelzoing instrument was acknowledged before me thin'ay of/-~i ~_, 2 by 0'~{,~.~, ¢,, ~_~ [~ , the ~'V2e,~./L- of 3~-~ oK DF0~nJl~.~alfof t Munieinal~tofAneh0mge. I ~ ~ ~ .... ~ PageSof5 Owner: Anchorage: DATE ~ , ' '- ' ' DATE , INSPECTOR ..... INSPECTIOR ~ . ¢'"'"~- . INSPECT(~ ..... · ' " MUNICIPALITY OF ANCHORAGE MUNICIPALITY OF ANCHOP. AGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTIOI~EPT' OF HEALTH &  ' ' 825 L Street - Anchorage, Alaska 99501' ENVIRONMENTAL P;~,OT[CTION ' ENV, RONMENTALSAmTATION DImmON APR 1 0 I981 Telephone 264-4720 . oU ST FO. - DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten Il0} 1. PROPERTY OWNER PHONE FESLER, $oe [ Loretta 345-9783 MAILING ADDRESS P. O. Box 10-588, Anchorage, AK 99511 PROPERTY RESIDENT III different from above} PHONE Same same 2, BUYER PHONE ,. 349-7961 A1 Kara ...... . MAILING ADDRESS unknown . 3. LENDING INSTITUTION [ PHONE Lawyers Title ...............................I 276-1151 MAILING ADDRESS _. P.O. Box 2260, Anchorage, AK 99510 4, REALTOR/AGENT [ PHONE Petie StrangI 279-7611 MAILING ADDRESS Dynamic Realty, S01 iq. Northern Lights, Anchorage, AK 99503. B. LEGAL DESCRIPTION - Lot 7..qhenandoah Hills Subdivision STREET LOCATION nhn Shenandoah Hills .... 6, TYPE OF RESIDENCE [] SINGLE FAMILY [] ' MULTIPLE FAMILY NUMBER OF~BEDROOMS [] One [] Four [] Two [] Five ~[ Three [] :Six Other 7, WATER SUPPLY INDIVIDUAL* [] COMMUNITY [] PUBLIC UTILITY * ATTACH WELL LOG. A well log is required for all wells drilled since June 1975. For wells drilled prior to that date, give well depth (attach log if available.) 8, .SEWAGE DISPOSAL SYSTEM [] INDIVIDUAL/ON-SITE** [] PUBLIC UTILITY YEAR ON-SITE SYSTEM WAS INSTALLED. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. ?~-mo (Re~. 6/~S)~.Z-~/'~' ~/2 1. TYPE OF RESIDENCE SINGLE FAMILY [] MULTIPLE FAMILY 2. WATER SUPPLY TH s S DE FOR o F,C A"' USE ONLY -El] INDIVIDUAL [] COMMUNITY [] PUBLIC UTILITY Connection 'Verified 3. SEWAGE DISpOSAL-SYSTEM ~ I NDIVI DUAL/ON -SITE r--IPiJBLIC UTILITY Connection Verified '~Septic Tank or [] Holding Tank Size: ~ If Tank is homemade give dimensions: TYPE OF ~_K TOTAL ABSORPTION-AREA 4. DISTANCES WELLTO: Absorption Area to nearest Lot Line NUMBER OF BEDROOMS [] ONE ~ THREE [] FIVE I--] TWO [] FOUR [] SiX PERMIT NUMBER DEPTH OF WELL &:.~' ~" DATE DR I LLED PERMIT NUMBER DATE INSTALLED INSTALLER SOl LS RATING MANUFACTURER Septic/Holding Tank IAbsorption Area ~/~ I Sewer Line 5. COMMENTS DATE ~"~APPROVED FOR 5~ BEDROOMS [] CONDITIONAL APPROVAL.{letter must accompany certificatel I--i DISAPPROVED OTHER INearest Lot Line 72-010 (Rev. 6/79) 825 'L' STR~T ANCHORAG~ ALASKA 99501 (907) 264-4111 GEORGE M. SULLIVAN, MAYOR DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION April 16, 198'1 Joe/Loretta Fesler Post Office Box 10-588 Anchorage Alaska 99511 Subject: Lot 7 Shenandoah Hills Subdivision Approval for the individual sewer and water facilities cannot be grant, ed until the foil.owing items have been co,,mpleted: ) .Th'e water analysis report needs to be delivered to this office from the Chem Lab~. 5633 B Street, for X~ our review. (2) Locate and expose the well for our inspection to determine proper construction~ also to insure minimum distance requirements are met between the well and sewer system. /(3) The septic tank pumped with a receipt submitted to this office. Please notify this department when the well has been exposed for a reinspection. If there are any further questions, please call this office at 264-4720. Sincerely, Robert C~ Pratt., R.S. Associate Specialist RCP/ljw cc~ Petie Str~ng % Dynamic Realty 501 West Northern Lights Lawyers Title Post Office Box 2260 99510 A MUNICIPALITY OF ANCHORAGS..~ DEPARTME. Of HEALTH AND ENVIRONMEN'~- PROTECT~_O~.~ · 825:' L Street, Anchoraa~.. AlasKa 99501 264-4720 91: Time 1:30 .p.m. ~ Date 3-28-78 Tuesday Insp Pratt Date Received: March 23, 1978 #2: ' #3: Time Date Time Date REQUEST FOR APPROVAL OF INDIVIDUAL SEWER AND WATER FACILIT S Lending Institution Request: First National Bank of Anchorage % Wes Club Mailing Address: Post Office Box 4-2090 99509 Phone: Property Owner: Mailing Address: 3. LegaI Description: 4: Joe Fessler % Dave Deans Phone: 277-0757 Lot 7 Shenandoah Subdivision Single Family Residence: (x) Multiple Family ReSidence: ( ) 5. Well System: individual well (x) Permit # Construction Number of Bedrooms: Three Number of Bedrooms: i Community/Public System ( ) Depth of Well 64' ! ! Well Log on File (x) Bacterial ~nalysis 6. Sewage Disposal SyStem: On-site System (x) .Public Utility ( ) Permit Septic Tank Size Absorption Area Installed 1977 Installer · Manufacturer Soils Rate Distances: Well tq Septic Tank to Sewer Line~,i Nearest Lot .line Material toiiAbsorption Area to Nearest Lot Line'i:~-' ! Absorption Area Page'Two Health and Environmental Protection of Individual Sewer ahd Water Facilities Subdivison ~ Department of Request for Approval Legal Description: Lot 7 Shenandoah Comments: Affadavit Attached: Approved: Date: Disapproved: I!' Date: Letter Attached: ( ) Department Worksheet: (,p:s .*,~o ,,,$) --O]OIAOUd .]DVUIAO:) :I:)NYUnsNI ON 009i: uuod Scl t(e~le~,sod snld) ~0£--'11¥~ O31.-llIU30 UO:! ld1303U · ~ l Depar Pro{e'6'~ion ·~- h_ 99501 ~ 264-4720 ' ~;" ~quest for ApproVal of Individual Sewer and Water.!F..ac.~'.l.i._.ties~ 1. Property Owner: Mailing Address Phone e Name of BUyer~~ ~'- Mailing Address Phone: o Lending Institution: Mailing Address: 3&~l Realtor/Agent: Mailing Address: Phone: Phone: Legal DescriPtion: Street Location: e Single Family Residence: Multiple Family Residence: (~'~Number of Bedrooms: ~ · ( ) Number of Bedrooms: (~'~Public/Community System Water Supply:_ *Individual Well If Individual Well, well depth ~1 If Community System, name of system ( ) 8. Sewage Disposal System: *~Dn-site System (~'~ Public System ( ) If On-site System, 'date of installation: *NOTE: A'well log is required on ALL wells drilled since 6/75. ** If on-site sewer system is over two(2) years old, an adequacy .test is required by this department. A fee of $25.00 must accompany each request before processing can be initiated. ~ 3/77 APPLId" ' FILLS:OUT HA['- ' "' " ~NT UPPER ~ ONLY' Phone ~:opert y'"~wner ~ ~,~. ~t ~c.J L~ ~ : : Buyer ~,1-I. ~ ~ ~ Address Zip Code : Phone Lending Institution /~ o,--~ ~ S ~ ~,~. c ~ Address Zip Code Realty Co. & A~nt ~O~ Phone Address · ~ Zip Code Legal Descrlpt~n ~ ~E~ ~O~ Street Locati~ ~H~ ~ ~ ~ Type of Resl~nce  Single Family 0 Multiple Family No. of Bedroo~ Water Supp}y ~ ~ ~ndi'v'idu~l -~ ~ ~ ~ A~ACH ~LL LOG. A w~l log Is required for all wells drilled since June 1975. ~ Community For wells drilled prior to.that date, give well depth (attach log If available). ~ Public Utility Sewer Disposal ~divld~l ~ear Indlv~ual Installed: ~P~ ~ Public ~ility When Connected to Publl~Utility: ~ Holding Tank ~TE: THE INSPECTION ~E MUST ~CCOMPANY EACH RE~EST BEFORE ~OCESSlNG CAN BE INITIATED. Time Time Time Time Date Date Date Date[,~.,.t,...t~,,l~"""~"~"-'~.~ Inspector Inspector Inspector · Inspector Field Notes: )APPROVED BEDROOMS 'CONDITIONS OF APPROVAL ( ) DISAP~OVED Soils R~ln~ Date ~wer Installed Well To ~sorptlon Area / ~ Well Log Received ~~/ ~ ~- ~- ~ WelltoTank / ~ Septlc:T~kSlze 72.023 (3/82} DATE: TO: FROM: / tt ficip i of MEMORANDUM February 17, 1983 Rodman Wilson, Director, Health and Environmental Protection SUBJECI:: Everett P. Diener, Director, Public Works Office of the Ombudsman CASE SUMMARY, NO. 82-112 The following case summary is provided for your information and review. If you have any questions, clarifying information, or comments regarding our determination or any other aspect of the case, please bring them to our attention so that we can incorporate them into this summary. Investigator Kathy Fr)ltT<'/' CASE SUMMARY In Date: I?-?I-R? Close Date: Category: HEAl TH AND FNVIRONMFNTAI PPflTF£TIflN.. <q~rfnrP Hn'l-mr ~, qpw¢,~- Cnnt'rnl(lrl R) PUBLIC WORKS: Building Safety (30.2) ~omplaint Summary: The complainant alleges that the Municipality should not have allowed development in the ~henandoah Hills Subdivision area due to the extremely high water table level. As a result, the complainant's crawlspace and septic tank require pumping on a regular basis. The complainant also alleges the plumbing leading from the house to the septic tank was not properly installed and this should have been discovered by municipal inspectors during construction, and therefore, the Municipality is liable for damages. Case Description: The complainant contends the Municipality should not have allowed the Shenandoah Hill§ Subdivision area to be developed. The complainant estimates the ground water level to be at two feet on her property. The ground water drains into the septic tank and has to be pumped frequently. The complainant consulted a private engineer who told her houses should never have been built in that area. The engineer further stated the area was not suitable for a conventional on-site septic tank system and recommended installation of a mound system at a cost of $15,000-20,000. The complainant purchased the house new in July 1980. During 1981, the complainant noticed water in the crawl-space. In the fall of that year it was necessary for the complainant to install a sump pump in the crawlspace. The problem was then checked by a plumber who discovered the pipe leading from the house to the septic tank had not been connected and the waste water was draining into the crawlspace. The plumber removed the water and sewage with a sump pump and reconnected the waste line to the building drain. The complainant feels, thi~ deficiency should have been discovered by municipal insPectors during construction of the 'house. Basis for Determination: The complainant's first allegation, that the Municipality should not have allowed development in the Shenandoah Hills Subdivision area, is determined UNSUPPORTED. Mr. Les Buchholz of the Environmental Health Division stated that the septic tank located on the complainant's property (Lot 9 Shenandoah Hills Subdivision) had.passed municipal inspection at the time of construction. At that time a percolation test was also conducted with satisfactory results. However, Mr. Buchholz added that the water table level in that area has been rising continually in the past few years. Since the area is being (12/79) Page 2 flooded with ground water many residents are installing sealed holding tanks, according to Mr. Buchholz. The complainant alleged further that the Municipality is liable for damages caused by faulty plumbing which she contends should have been discovered during the plumbing inspection. Earlier during this investigation, the Buiding Safety file on Shenandoah Hills Subdivision could not be located. The complainant concluded from this information that Building Safety inspections were not performed. However, the file has been found and is in the Building Inspection office. The file includes the final plumbing inspection which was performed on July 1, 1980 and the Certificate of Occupancy which was issued on July 9, 1980 for the complainant's house. This office spoke with Randy Flowers of Price's Plumbing, the plumber who repaired the pipe in the complainant's basement in 1981. According to Mr. Flowers, the sewage in the basement was not attributed to a defect in the main line, but rather to a 3" x 2" "comby fitting" which was not capped off. He stated further that the plumbing could not have passed inspection if the cap was not in place and added that water pressure could have caused it to come off it it was loose. However, Mr. Schurman, Building Safety Mechanical/Plumbing Inspector, stated plumbing inspections include checking for leaks after 15-20 gallons of water is run thought the pipes. Based on the information provided by Mr. Flowers and Mr. Schurman in addition to the fact that the plumbing passed inspection, the complainant's second allegation is also determined UNSUPPORTED. Case Action: The complainant filed a complaint with Public Works and requested an inspectio in June 1982. Mr. Lou Schurman responded to the request. Mr. Schurman noted during his inspection that when an upstairs toilet was flushed, clear water overflowing the garage floo drain and also overflowing the open clean-out outside the house approximately two feet from the foundation. Mr. Schurman advised this office that the problem appears to be a maintenance and septic system problem and the Building Safety Division feels there is nothing they can do. The complainant has filed a claim with the Municipal Risk Management Division. The matter i being investigated by Scott Wetzel Services, Inc., the investigators for the Municipality's self-insurance program. WA)HqE D. MABRY, OMBUD~StqAN KLF:sl CC: Case File 82-112 Complainant John Bishop, Building Official Ron Watts, Chief of Building Inspection L. Schurman, Building Inspection Les Buchholz, Surface Water & Sewer Control Ed Walsh, Scott Wetzel Services