Loading...
HomeMy WebLinkAboutCHICKADEE SLOPES TR A LT 4BChickadee Slopes Tract n Lot 4B #015-231-86 Municipality of Anchorage' Development Services Department Building Safety Division Ort -Site Water and Wastewater Program. 4700 Elmore Road P.O. Box 195650 Anchorage, AK 99507 Page of www.d anchorage.skus (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number. SWO90071 PID Number. 015-231-86 Mew Michael oulrk Wastewater System: 1] New ❑ Upgrade Baa... P.O. Box 111398 Anchorage, AK 99511 ABSORPTION FIELD Paw 441-9352 Munxr a B•aaom• 4 P Do" Turn O serbw Tm D BW O Mw 13011W DESCRIPTION sat FtsLEGAL a 1.2 T� 12� GP Ft, 13 c La 4B auEawrpn DWM top txeom ape W"J•a• Gn aLpu+pr PPe Chickadee Slopes 8 n. 4 Ft Tow wV Rrpe salon Fr e0a•0 eaoN apnr Vea• Cn Lergm 0 to •1 Ft, 50 Ft, Well: ONew Upgrade t.a� dlmll Dwtrge IIMI 5 Ft. CwLmmcvt (P . A B. C) Tar DW. Cewa m Tar mewl t on rw Pq 4etrir Private 206 Ft. 1 58.32 FL 500 Fe ASTM D3034 PVC Dawn aw Da st • Wr•r Levy n Iw att, w M -W Drilling 7/20/09 61 FL Sanders 6 Sanders 7116.17109 Ywa Pw setaa..gtwp�tAom CG TANK 5 CPM Ft. 2 FL SEPARATION DISTANCES O Septic ❑ Holding ❑ S.T.E.P. ❑ Other. To Septic Absorption Lift Holding ublx/Prwate •a'••` o From Tank Field Station Tank sewer urts Anchorage Tank 1,250 or Mr Mnw•r a Canprvilriw w•r >100' >100' N/A WA >26 Steel Two (2) s,erwwr >190' >100' N/A NIA LIFT STATION La (bw >5' 6'— NIA N/A Gr 'Pump an' ww a 'Pump ar M.M K Mpn wewr rrm a Fanaeoal >V >`!T WA NIA In in h Pom MM• a Meer Elcmrll lnpcemF pwW W cvun(x.n None Noted R� See Lot Line Waiver. BENCH MARK unopn.v D«apiwn. Garage Slab • •oan 100.0 FL A. Harala 7/16109 Engine/ Stamp MIlkI Inspections performed by: Dates: 1M �t,� 2nd 7/17109 Skit, ......e�,C,gs1I, • Development Services Department Approval .F vj: •.�y�i Conditional Approval Date: «•« ••• •.. • P i MXNAM ! ANDUM011I : oa :• CE -4381 *•\z�. Reviewed and approved by: Date: Ppa jESStO���� mof — _ _ _ — _ — _ — _ _ — — _ — _ '�♦♦♦ ...... �'f/y�•• IL c M80 300R1N0021 : ''-C�'11 ••• d . :o m p• IL ZO'991 M .SS JO 00 N ;. �: Li u N, + : OIV i •jam �. O� : . � Z � i I ••��.., I fY� I 1 I I I s z m ` O g LLI;; m G a y y 1 pE O d f0 m @ + 12 W D q ` 00, ---------------- u 0 Y J `o>< W o A s H o: Q.. Q � CL O a $ UJ N Q = o apq a Q Lit c:_: m W W N � 11 �0 Q 0o U J E = z h 0 O Q J^ v L.1._ i,b>AA Fb b FIA Af. :n ii F <oo R^n 9+ �n l4i O O� N L: 3N3rM'V3 ALnLLnOl d aa E SO'99L M ,00 ,ZO 00 N z r IL Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519655 - 343-7904 Onsite Wastewater Disposal System or Well Inspection Report Permit Number. SWO90071 y / y Uf.7 IFinYve Enmq __ Gmunu > 1,250 Gallon Septic Tank i.9 5.7 Page 3 of 3 PID No. 015-231-86 25' (Trench Length) WEST TRENCH N 97.6 90.54-1 II Drainfield Rock 86.4 79.1 No Groundwater 5/12/09 EAST TRENCH PROFILE AS -BUILT No Scale 3.2 90.4 �, v /98.6 II 96.8 p / —L II 111 ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (F May 27, 2010 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Tract A, Lot 4B, Chickadee Slopes Subdivision Separation Distance Waiver Absorption Trench to Lot Line Dear On Site Services Engineer: The lot line was not clearly marked during construction of the absorption trenches on Tract A, Lot 4B, Chickadee Slopes Subdivision. The westernmost trench was inadvertently placed at 6' from the north property line. Placement of the absorption trench at this location will not adversely affect neighboring lots. The well on the lot to the north is more than 170' away and the septic system on the lot more than 50'. We hereby recommend a lot line waiver be issued allowing placement of the absorption system at 6' from the north lot line. Sincerely, Michael E. Anderson, P.E. 1W VC -A__ E. A\JEIS9\ MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGALDESCRIPTION: LOT 4B, CHICKADEE SLOPES SUBDIVISION PERFORMED FOR MICHAEL QUIRK DATE: 7/16/2009 PROJECT No.: PARCEL ID#: TECHNICIAN: A. HARALA DEPTH TEST HOLE 3 Met) 1 10 f 11 12 BOH @ 12.0' 13 14 15 16 17 18 19 COMMENTS: SLOPE SITE PAN SEE SITE PLAN R WAS GROUND WATER ENCOUNTEREDP No ff YES ® WHAT DEPTH^ DEPTH OF WATER AFTER MONUTORLNG: 3-S% DATE OF MONTTOMNG: DATE READING OG/01- G/OL2 NET TIME (MINUTES) EP ER O (INCHES) NET DROP (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 7/16 2 8:14/8:24 10 2,25/10.5 y: a. •. 3 . 10 4 3 8:37/8:47 POORLY GRADED SAND 5 •�,+. •• WITH SILT 4 • SP/SM 6 ;. 5 9:02/9:12 10 7 8.00" 8 w 10 2.25/10.25 8.00" 9 '. .. 10 f 11 12 BOH @ 12.0' 13 14 15 16 17 18 19 COMMENTS: SLOPE SITE PAN SEE SITE PLAN R WAS GROUND WATER ENCOUNTEREDP No ff YES ® WHAT DEPTH^ DEPTH OF WATER AFTER MONUTORLNG: 3-S% DATE OF MONTTOMNG: DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) EP ER O (INCHES) NET DROP (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 7/16 1 8:14/8:24 10 2,25/10.5 8.25" 2 8:26/8:36 10 2.12/10.25 8.13" 3 8:37/8:47 10 2.00/10.00 8.00" 4 8:50/9:00 10 2.25/10.25 8.00" 5 9:02/9:12 10 2.12/10.12 8.00" 6 9:14/9:24 10 2.25/10.25 8.00" PERCOLATION RATE• 1.3 (MIN/INCH) PERC. HOLE DIA 6. �� (INCHES) TEST RUN BETWEEN:1 1.0 FT. and 12.0 FT. TEST PERFORMED BY ANDERSON ENGINEERING. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 5/27/2010 Job No. 09.116 Well Owner. Legal Description: M -W Drilling, Inc. •P.O. Box 110389*Anchor'age, AK 99511• •907-345-4000 • 907-345-3287 Fax• GROUNDWATER WELL AS -BUILT & LOG Use of Well: Domestic Hale Depth: 206' Casing Size: 6' Cased To: 58.32 Material: A 53 Steel GR B Wall: 250 Drill Method: Air Well Completion: Open end X Screen _ Perforated _ Perf. Method: Screen/ Perforation description: Grout Notes: ( 3 ) Sack(s) of Bentonite Notes: Bedrock from 58' to 206' Well Development Method Notes: Static water level (SWL) 61' below top of casing (TOC). Well yield test at 5 Gals. per minute (GPM) for 1 hour(s) with 100% of drawdown (DO) from static level(SWL). Method: Air Lift Stan Date: 7/17/09 Completion Date: 7/20/09 Pump Install Date: WELL LOG Depth in feet from top of casing. Details of formations penetrated, size of material, color and miscellaneous detailft, 0 TO 3 Casing Stick Up 3 TO 57 Gravel, cobbly, silty 57 TO 206 Bedrock: blk siltstone argillite with small water seaps in To sporadic fractures TO TO TO TO TO To WAYNE E. W TBERG TO TO President, M -W Drilling, Inc. WGWA AkGgnCtrLIcNaloW TO TO TO TO Legal Description chickadee Slopes Development Services Department Property Owner Name K Address: Michael Quirk PO Box 111398 Anchorage, AK 99511 Building Safety Division , O x r, �+ y 4" On -Site Water 6 Wastewater Program 4700 Elmore Road feet P.O. Box 196650 s Mark Begich Anchorage, AK 99507 Mayor muni,cm/onsitl `S (9 (907) 343-7904 Pump Installation Log Well Drilling Permit number: SW'09007t Date of Issue: 5126109 Pared lAnntinentian Number:015-231 6 Legal Description chickadee Slopes Property Owner Name K Address: Michael Quirk PO Box 111398 Anchorage, AK 99511 Pump Installation Date: 01/1312010 Pump Intake Depth Below Top of Well Casing: 206 feet Pump Manufacturer's Name: Grunfos Pump Model: IOSOEI.330 Pump Size 1 (one) hp Pitless Adapter Burial Depth: 10 feet Pitless Adapter Manufacturer's Name: Unknown Pitless Adapter Installer: Unknown Well Disinfected Upon Completion? ❑ Yes El No Method of Disinfection: Comments: Pump Installer Name: M -W Drilling. Inc. Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. MUNICIPALITY OF ANCHORAGE Dlevelopment Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 015-231-86 1. GENERAL INFORMATION Expiration Date: I - Z 3 ' 2 Z� Complete legal description Chickadee Slopes, Tract A, Lot 413 Location (site address) 12240 Rockridge Drive Anchorage, AK Current property owner(s) Michael & Mary Ann Quirk Day phone (907) 441-9352 Mailing address P.O. Box 111398 Anchorage, AK 99511 Real estate agent 2. TYPE OF DWELLING: ❑� Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) Day phone 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well ❑■ Private Septic 0 Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 9 I2. SD CO V) D Waiver Fee $ Date of Payment Receipt Number. Q0 COSA# 05G201571 Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm Forge Engineering Phone (907) 522-7773 Address 1399 W. 34th Ave Suite 101, Anchorage, AK 99503 Engineer's Printed Name Michael E. Anderson, P.E. Date 10/15/20 OF �,. °• °® 6. DSD SIGNATURE ®' 'a9th .. 6 • ' ` 09 u..... ......................E .. ..:'�..® —PYA System #1 Approved for L bedrooms ®��, :, r.�Icr+AELEANDERsoui�jlg o c� System #2 A roved for bedrooms ®'sem �..,. IN 0. CE -4.381 pp Disapproved pp 0�®4���p�0/15/20®®" OFES �® ®gaals Conditional approval for bedrooms, with the following stipulations: vurAI Ln n" &a 1NAST'�' v' o G ODnr,r. AAA c i A p �\ Nr SER\1\ ,�S t By: ` Original Certificate Date: / O 'oy "z0 The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist blue sheet Legal Description: Chickadee Slopes, Tract A, Lot 4B If more than 1 septic system on lot: COSA Checklist # of A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled 7/20/09 Total depth 206 ft Cased to 58 ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) '18 in. Date of flow test for COSA 10/13/20 Static water level at beginning of test 72 ft. Comments B. TANK DATA Age of tank(s) 11 years Tank type/material Septic/Steel Measured operating fluid level in septic tank 49 ❑ Standpipes/foundation cleanout per record drawing Date of pumping 9/23/20 -Alaska Quality Septic D. ABSORPTION FIELD DATA Deep Trench Which system tested (date installed) 7/17/09 0 ALL standpipes present per record drawing Total measured depth from grade 12 ft (max) Measured depth to pipe invert from grade 7.3 ft (min) ❑ N/A — pressurized field ❑ Monitor tubes go to bottom of effective. If not, state depth into effective Parcel ID: 015-231-86 Structure served by this system Well production at time of test 3.5 gpm Water storage tank volume None gallons Well disinfected for coliform test? ❑ Yes ❑ N ❑ Coliform bacteria is Negative Nitrate mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ❑ Arsenic less than MRL (ND) Collected by FORGE ENGINEERING Date of Sample 10/12/20 C. LIFT STATION ❑ Required maintenance completed Age of lift station years Lift station material Comments: Adequacy test date 10/13/20 Results ED Pass For 4 bedrooms Fluid depth prior to test 0 in Water added 671 gal New depth 6 in Elapsed time 1440 min ❑ Code -required soil cover over field Final fluid depth 0 in ❑ System presoaked Absorption rate >600 gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) No date of test) Gallons introduced gallons If yes, enter date Comments/Deficiencies: COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' ✓❑ Yes Community Sewer Manhole/Cleanout > 100' 0 Yes if No ft 0 Yes if No ft Neighboring Tank > 100' F71 Yes if No ft Private Sewer/Septic Line > 25' 0 Yes if No ft Absorption Field on Lot > 100' F/� Yes if No ft Holding Tank > 100' Yes if No ft Neighboring Absorption Fields > 100' Yes if No Animal Containment > 50' ❑✓ Yes if No ft F71 Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' F/� Yes if No ft Fv� Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' 0✓ Yes if No ft Surface Water > 100' ❑✓ Yes if No ft Property Line > 5' ✓❑ Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' 0 Yes if No ft Private Wells > 100' ✓V Yes if No Water Main > 10'✓❑ Yes if No ft Community Wells > 200' ❑✓ Yes if No. Water Service Line > 10' ❑✓ Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' El Yes if No ft If absorption field is under driveway comment below Property Line > 10' ❑ Yes if No 6* ft Wells on Adjacent Lots: Water Main > 10' ❑✓ Yes if No ft Private Wells > 100' ❑✓ Yes if No Water Service Line > 10' ❑✓ Yes if No ft Community Wells > 200' ❑✓ Yes if No Surface Water > 100'✓71 Yes if No ft F. ENGINEER'S COMMENTS *See Lot Line Waiver No. OSC 101059. G. ENGINEER'S CERTIFICATION QF � P .......;� q �� ! certify that I have determined through field inspections and review �'� .••'''f� '''••... of Municipal records that the above systems are in conformance with ` MOA COSAguidelines in effect on this date. +AV :� 49th��� u.. i.. non..... ....s.},.}u.. 0■........ nunn... u....n.uuu.8 O® .;o MICHAEL E. ANDERSON e No. CE -4381 .•'�� �' T� �''•.. 10/16/20 .•'•• �� COSA Checklist yellow sheet F40p'.""""".ROFESSS . P�--'40 il ft ft ft Parcel I.D. Municipality of Anchorage Development Services Department Building Safety Division Onsite Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING 015-231-86 1. GENERAL INFORMATION COSA# i�zsC lND�� Expiration Date: Complete legal description Tract A, Lot 413, chickadee slopes subdivision Location (site address) 12.240 Rockridge Drive Anchorage, AK 99516 Current Property owner(s) Michael Quint Mailing address Lending agency P.O. Boz 111398 Anchorage, AK 99511 --Mailing address — - -- - Real Estate Agent Mailing Address Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: Four (4) 3. TYPE OF WATER SUPPLY: Individual Well❑ Individual Water Storage ❑ Community Class Well ❑ Public Water System ❑ Day phone 441-9352 Day phone Day phone TYPE OF WASTEWATER DISPOSAL: Individual On-site❑ Individual Holding Tank ❑ Community On-site ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) issues Certificates o' Onsite Systems Approval (COSA) based only upon the representations given in paragraph 4 by an indepenee professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are requireo for the transfer of title (except between spouses) for properties served by a single-family on-slte wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my Investigation, based on procedures outlined In the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system Is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my Investigation and Inspection, the on-site water supply and/or wastewater disposal system Is(are) In compliance with all applicable Municipal and State codes, ordinances, and regulations In effect at the time of Installation. Name of Firm Anderson Engineering Phone 522-7773 Address P.O. Box 240773 Anchorage. AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. Date 5272010 OF A4144 -��• 1 17 p .MOtAa E AMQWN� AW b. DSDSIGNATURE ���!r�:• C8.4381 ��.4; Z.7 -10 Approved for bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: -- Y OFA%,, ..... J ' ONSITE WASTEWATER tKUUKAM AN o •. �. "�U/111111)N Attachments: COSA Checklist X Arsenic Advisory Septic System Advisory Maintenance Agreements Well Flow Advisory Supplemental Engineer's Report Nitrate Advisory Other By: '---'�­Originat Certificate Date:_ '�C7 dlz� (R«. nus Municipality of Anchorage • "' Development Services Department Building Safety Division OnSBe Water 3 Wastewater Program " "' 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www.muni.org/onsfte (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: Tract A. A Chickadee Sioaes SubdMsion Parcel 10: ors -231.86 A. WELL DATA Well type Private If A, B, or C provide PWSID # _ Well Log (Y/N) Y Date completed 7Mro9 Sanitary seal (Y/N) Y Wires properly protected (YIN) Y Total depth 205 fl. Cased to 56.32 ft. Casing height (above ground) >16 in. FROM WELL LOG AT INSPECTION Date of test U20109 Static water level 61 R ft. 9—Well production 5 g.p.m. p.m--WATER SAMPLE RESULTS: -- Coliform 0 - coloniW100 mL Nitrate NO mg/L Other bacteria' o colonies/100 mL Arsenic: NID ugA Date of sample: EL111=10 Collected by: a Harare B. SEPTICIHOLDING TANK DATA Tank Type/Material SeOclsteet Date installed ' 7/16/2010 Tank size 1.250 gat. Number of Compartments Two Cleanouts (YM) Y Foundation cleanout (YIN) Y Depression over tank (YM) N High water alarm (YM) N Date of pumping New ConM=110^ Pumper N/A C. ABSORPTION FIELD DATA Date installed 71172010 Soil rating (g.p.dJe or ft"Ibdrm)1.2 GP 7l8F System type 5' Wide Trench Length 50 fL Width 5 ft. Gravel below pipe 4 ft. Total depth 11-12 ft. Eff. absorption area -LO—fl? Monitoring tube Y Depression over field N Date of adequacy teat New Const Resufts (Pass/Fail)For—bedrooms Fluid depth in absorption field before test in. Water added gal. i New depth In. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date D. LIFT STATION Date installed Size in gallons 'Pump on' level at _ in. 'Pump off* level at _ in. Datum Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot >100, Absorption field on lot >100' Public sewer main N/A Manhole/Access (YIN) High water alarm level Meets alar 8 circuit requirements? On adjacent lots >100' On adjacent lots >100• Public sewer manhole/cleanout N/A Sewer /septic service line >27 Holding tank N/A Animal containment areas None Manurelanimal excrete storage areas None SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5' Property line >5' Absorption field >5 Water main N/A Water service line >1a Surface water >too Welts on adjacent lots >100 - SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 5"" Building foundation >10' Water main >to Water Service line >1a Surface water >100• Driveway, parking/vehicle storage >25' Curtain drain None Noted Wells on adjacent lots >100v F. COMMENTS: 'See Lot Line Waiver. i in. G. ENGINEER'S CERTIFICATION AM ��'•"•"'•� 9��f 1 certify that I have determined through field inspections and Woo* *o review of Municipal records that the above systems are in •, conformance with MOA COSA guidelines in effect on this date. Michael E. Anderson. P.E. 'r°' L AND6tE N W ,i Engineer's Printed Name I� ,• CE -4381 ?, Date 527/2010 COSA Fee $ Date of Payment Receipt Number Y �1oZ (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number0 5P 101060 DYK�I Municipality of Ancho P.O. Box 196650 • 4700 Elmore Road Anchorage, Alaska 99519-6650 • (907) 343-7904 • Fax (907) 343-7997 http:/twww.m u nl.orri/Onsite Development Services Department On -Site Water and Wastewater Program Menr cirr Department **** VARIANCE/WAIVER REVIEW **** WR#: OSP101060 HAM OSC101059 Permit#: SW090071 PID#: 015-231-66 Legal Description: Chickadee Slopes Tract A Lot 4B Engineer. Anderson Encilneerincl Applicant: Micheal Quirk Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 6.0 feet. This waiver approval applies to the existing absorption field to property line separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ..................................................... a ...... .............. ..... Waiver Is Granted: X Waiver is not Granted: Dale: 6/9/2010 Approved by: O e of eviewer Rec#: 045211 Amount: $200.00 Date Paid: 5-27.10 **** VARIANCE/WAIVER REVIEW **** rig<V y= YC£�9•o i� IX na^o�m mcy aOCy oma g� 6� 0 0 I 7 N 00 02' 00• W 165.03 UTILITY EASEMENT --------- — O n n [ L mr In In • e +I a / � I / r , / a I / ` I ROCKRIDGE_DRIVE iA x:� F ° o y as • , `• i Op rig<V y= YC£�9•o i� IX na^o�m mcy aOCy oma g� 6� 0 0 I 7 N 00 02' 00• W 165.03 UTILITY EASEMENT --------- — O n n [ L mr In In • e +I a / � I / r , / a I / ` I ROCKRIDGE_DRIVE iA MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water d Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Permit Number: SW090071 Legal Description: Chickadee Slopes Design Engineer: 0014 ANDERSON ENGINEERING Owner Name: Michael Quirk Owner Address: PO Box 111398 Anchorage , AK 99511 - Date Issued: May 26, 2009 Expiration Date: May 26, 2010 Parcel ID: 015-231-86 Site Address: 12240 Rockridge Dr Lot Size: 49504 SO. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: 0 Disposal Field 0 Septic Tank ❑ Holding Tank ❑ Privy Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904( 24 hours). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. A. THE SEPTIC TANK SHALL NOT BE BURIED DEEPER THAN 5.5 FEET. B. THE ENGINEER NEEDS TO DO AN ADDITIONAL PERCOLATION TEST TO VERIFY THE LOCATION OF THE PROPOSED RESERVE FIELD PRIOR TO CONSTRUCTION OF THE SEPTIC FIELD. PLEASE SUBMIT STAMPED AND SIGNED RESULTS WITH THE AS -BUILT INSPECTION REPORT. IF THE RESULTS REQUIRE A DESIGN CHANGE, CONSTRUCTION OF THE SYSTEM WILL STOP PENDING ON-SITE REVIEW AND APPROVAL. Received By. Date: 61al A t Issued By:/: (L, 11�/ / �� Date: 7 Municipality of Anchorage Development Services Department Building Safety Division _ On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519.6650 www.muni.org/onsite (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 015-231-86 Property owner(s) Michael Quirk Day phone 441-9352 Mailing address P.O. Box 111398 Anchorage, AK Zip Code 99511 Site address 12240 Rockridge Drive Anchorage, AK Zip Code 99516 Legal description (Sub'd., Block & Lot) Tract A, Lot 4B, Chickadee Slopes Subdivision Legal description (Township, Range & Section) Lot Size 49.504 Sq. Ft. Number of Bedrooms Four (4) THIS APPLICATION IS FOR Q all that apply): THIS APPLICATION IS AN: Absorption Field 0 Initial 0 Septic Tank F±1 Upgrade ❑ Holding Tank ❑ Renewal ❑ Privy ❑ Private Well Water Storage ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: i 30 Waiver Fees: Date of Payment: Receipt Number. (Rev. 11105) Date of Payment: Receipt Number. ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 FAX May 13, 2009 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 46, Chickadee Slopes Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 4B, Chickadee Slopes Subdivision intends to construct a new four- bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to accommodate the home. The attached Site Plan and backup documentation identify the location and configuration of the proposed well and septic system along with the alternate site. Also identified on the plans are the existing wells and septic systems on surrounding lots. No conflicts exist between the proposed well and septic system and wells or septic systems on adjacent lots. Drainage arrows are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. The test holes placed on the lot in the area of the absorption trench and alternate site indicates silty sand and gravel to poorly graded sand (SM/SP/GM). The percolation rate of the soil was determined to be between 1 and 5 minutes per inch. No groundwater was found during the placement of the test holes and none was noted during the monitoring period. An application rate of 1.2 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,250 -gallon septic tank and two 25' long by 5' wide by 4' effective depth absorption trenches to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trenches will be 8' below the surface and the total depth will be 12'. A flow splitter valve will be placed to insure even flow to each trench. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. The ground surface on the lot in the area of the septic system slopes to the southwest. The new trench will be constructed parallel with the ground contours as much as Lot 4B, Chickadee Slopes Subdivision May 13, 2009 Page Two possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from all wells and any surface water and 10' the proposed and existing water services in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, (Ea L , Michael E. Anderson, P.E. Attachments 0 �U; 49;n X. Y - W L C. AY)ERSC% I i i' 4A OQ mi \ n wecse•oo•rr n 0 w - U _ O K Y U . C=M K 4 1 5 18 1A 0 UPPER HUFFMAN DRNE • 49th •.....:. ..... ....... .... . ....5.. AREA MAP � V ;LMICHAEL ANDERSM*/ • ,�1�f/j, SCALE 1' = 100' ��j ; ..S'OS ••''i 3ni�Ja 30CMIA00�1 s i 0, 03 1"a u�= 8 V I I I r ` wr\\ z M\O r � /yIJ y� tj O �I -,d-V M > V) Q]y = n II O o o Ld J N rn m a- �\ m J QN N N u V) O N N U g H VN a W z 00 p z Q ' U coon -D'o = °a$ U nom« N <j o C \ O c;; d O J" 0 �L2 u NNW C N 1- 1! (4"t I- -------------------------------- luawaso3 Al! nn ,Ol i'0'99l :I7I'( :Li 1l 6 le • LOT 4B, CHICKADEE SLOPES SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom Home 5' Wide Trench System Perc. Rate: 1-5 Min./Inch 1,250 Gallon Septic Tank Application Rate: 1.2 GPD/SF 4' Drainfield Rock 4 Bedrooms X 150 GPD/1.2 GPD/SF (Application Rate) = 500 SF Absorption Area 500 SF/5 SF/LF•.5 (Red. Factor) = 50 LF Trench Length THEREFORE: Construct 2 - 25' Long x 5' Wide x 4' Effective Depth Absorption Trenches at the Location Shown. Flow Line Elevation in Trenches to be 8' Below Original Ground Surface. Total Depth to be 12' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. Place a Flow Splitter Valve to Insure Even Flow to Each Trench. Natural Backfill 7,6,' Geotextile Fabric 6 O 4" Perforated PVC (Holes Down) 4'0" 5' Drainfield Rock TYPICAL 5' WIDE TRENCH SECTION (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Wells in the Area. Minimum 100' Separation From Surface Water or Streams. �. MSE .OF.q���t� Municipality of Anchorage Lae ebpmentservices.Department' 49SH v *fie .. 19undn9 Safety DWidw / .... ... .. . ..... •... •,0 y� ctFweWatdrand wastewater Prwram• i-•• ....... 49P4700 Ornvs Road " MICH,gEI E •�� P.O. Sm 1901150 Mdi ge. AK 99507. ,I CE - 43 1 S ' `r W . V w sndy—noe.ak.us t �F •eS�S� : •V��� . (907)3479O4 S�f0 •••.....••• a e► .soils Log-peecolation Test ,• PerTcrmsdFor. ' MicNeiI;Brain .. - DaceParrorrr+eG '� Dr/ . Legal � ;, 'Chickadee Slopes Subd.; Lot 4BTgA,nehlp.Range. Sectlrn: Sop Ste Rm_ v 3; �• 4: 5 (((��� i 6_ .S- T • ... ' . WAS GROUND WA" • . e g_ EvcouNTE RED? _ 5.. : 1t}- • iYES.ATWHATDEPTHf '. • O r . Depth to Water Arty 11 13- ReadnD Date Craw TFne Net Time - Depth to Water Net Drop - 14-- 15 1 /'�"!' Iii �31�'i'1• IIS .9'1" 1& / 1+59: Z7 sip zo Y Inc t¢;ly 23•y " �3 L—JE .. ..:_... ..__._.. .._...---.. .------•— ."_COUITION RATE (mYwreFwAl _ ... .. PERI Nott pAYETE1t • . TESTRUNBETWEEN •'FT AND I- FT - t UARMENTS ; L� . PI72FORMED 8Y: CERTIFY THAT THIS TEST WAS ' T1�' ..:..PERFORNED INACCORD4NCEWTH ALLSTATE AND MUNICIPAL GUIDF1P1E5IN EFFECT ON THI50.4TE DATE - . OF+� Municipality of Anchorage .• (ENGINE RS a Development Services Department �• 4 9 D '� :-7e' Or Slte �eudWastewater eProgram •• �r i. ... 1 ` fN11 . 700 Omar. Road�...� .......... .. e�j P.O. Bax 196&50 Anchorage, AK 99507 .._.__�_ A1tClfAiI-F-Ar�p�kyCp-._-s-._ / www.N.anehaaae.ek.us P f:• -CE-4381. (9Dn 343-7904 , 'Fp•.S—I i—C y�•: �c� Soils Log -Percolation Test 44�'TorissmO.0:~ Pwf=-d For "Michael Brain Date Perlam,et 3 DJ Legal Descdptlrn: ' Chickadee Slopes Subd., Lot 4B TgA..hlp. Range, sec6an r 9cp Ste Flan I. oL .1. 2-P61H � .•is o:.. L t. it, (� 3,r3 b1Yti�l�•+h►wl ;. 4 f r1 I.. U 6- • 'g_ � e WAS GROIND WATER .• . ENICOUNTERED? 14 1 IFYES.ATWWVDEPTh7 �'. / Depth to WaterARsr Mann~12 ter✓ E 1 13 MC l / Reading Date : Gross Inure ' Net Tkne Depth to water Net Drtp .. . 14- 1s I6 30 115 I O•0. 17-/ is 0 30 it 20- . PERCOLATION RATE .: PERC MOLE DIAMETER• F • TESTRUN 9EIWEEN FT' AND FT .;. .. - PERFORMED BY: .. 1 '- -.,CERTIFY TFV.T'THIS TEST WAS "PERFORMED IN ACCOItDVNC WITH ALL STATEAND MUNICIPAL GUIDELINES IN EFFECTON THIS RATE "DATe 1- •`'..: MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 DEPTI I (&e0 I- 2 3 4 5- 6 7 8 9 10- 11 12- 13- 14- 15- 16- 17- 18- 19 - SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT 4B, CHICKADEE SLOPES SUBDIVISION PERFORMED FOR: MICHAEL BRAIN DATE: 3/4/2009 PROJECT No.: PARCELID#: TECHNICIAN: A. HARALA TEST HOLE 2 OG/OL A O C •.. SILTY SAND • WITH GRAVEL v SM/GM A 4. O A SITE PAN SEE SITE PLAN R k Y i WAS GROUND WATER ENCOI.NTERED? NO IF YES Q WHAT DEPTH' • DEPTH OF WATER AFTER MONITORING NONE e DATE OF MONITORING .7 ] POORLY GRADED SAND WITH SILT e SP/SM BOH @ 19.5' DATE READING G7'0SS TIME (MINUTES) NET TIME (MINUTES) DEP ER O (INCHES) N€T DROP FINCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 3/5/09 1 2:02 4.38" 2 2:12 10 12.63" 8.25" 3 2:13 4.25" 4 2:23 10 12.38" 8.13" 5 2:24 4.50" 6 1 2:34 1 10 1 12.63111 8.13" PERCOLATION RATELI-2 (MIN/INCH) PERC. HOLE DIA 6. � (INCHES) TEST RUN BETWEEN:: 8_0 FT. and 9_0 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 5/12/2009 Municipality of Anchorage -. Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519.6650 www.muni.org/onsite (907) 343-7904 Parcel I.D. CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING 015.231-86 1. GENERAL INFORMATION COSA# ('),SC 10'10��l Expiration Date: I - �L /21 Complete legal description Tract A, Lot 4B, Chickadee slopes subdivision Location (site address) 12240 Rodoidge Drive Anchorage, AK 99516 Current Property owner(s) Michael Quirk Mailing address Lending agency - ---- ------ --Mailing address - - Real Estate Agent Mailing Address Day phone 441.6362 P.O. Box 111398 Anchorage, AK 99511 Day phone Day phone Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: Four (4) 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual On-site Q Individual Water Storage ❑ Individual Holding Tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates c' On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an indepenee professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are requireo for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also Issues COSAs upon request to homeowners. Certificates of Ons to Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, 1 verify that my Investigation, based on procedures outlined In the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system Is (are) safe, functional and adequate for the number of bedrooms and type of structure Indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my Investigation and inspection, the on-site water supply and/or wastewater disposal system Is(are) In compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of Installation. Name of Firm Anderson Engineering Phone 522-7773 Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. Date 5172010 L MORSOH: ,4: 6. DSD SIGNATURE s CE -4381 �i _Ie, Approved for bedrooms. •,,�f��,�, Disapproved. Conditional approval for bedrooms, with the following stipulations: Attachments: COSA Checklist X Arsenic Advisory Septic System Advisory Maintenance Agreements Well Flow Advisory Supplemental Engineer's Report Nitrate Advisory Other By: Ll/, Original Certificate Date:�j��` — LO (n.. „W) Municipality of Anchorage Development Services Department Building Safety Division Onsite Water & Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: Tract A. Ld B, Chickadee Slopes Subdivision Parcel ID- 015.231-86 A. WELL DATA Well type Prwete If A, B, or C provide PWSID # _ Date completed 7120109 Sanitary seal (YIN) Total depth Zoe ft. Cased to x•32 ft. FROM WELL LOG Date of test 7rz001 Static water level 61 R Well production 5 g.p.m. ---WATER SAMPLE RESULTS:—.---------... .__-------.. Coliform o - colonies/100 mL Nitrate N/D mg/L Arsenic: N/D ug/I Date of sample: 5n8no10 B. SEPTICIHOLDING TANK DATA Tank Type/Material sepik•JSteei Tank size 1,250 gal. Number of Compartments Two Well Log (Y/N) Y Wires property protected (YIN) Y Casing height (above ground) >18 in. AT INSPECTION Otherbacteria 0 colonies/100mL Collected by: A- Haraia Date installed 7/16/2010 Cleanouts (Y/N) Y Foundation cleanout (Y/N) Y Depression over tank (YIN) N High water alarm (Y/N) N Date of pumping NeW Construcdon Pumper N/A C. ABSORPTION FIELD DATA Date Installed 7/17/2010 Soil rating (g.p.dJft or ft'/bdrm)1.2 GPorsF System type 5 wide Trench Length 50 ft. Width 5 ft. Gravel below pipe 4 R Total depth 11.12 ft. Elf. absorption area 500 ft Monitoring tube Y Depression over field N Date of adequacy test New Conat• Res ufts (Pass/Fail) For _ bedrooms Fluid depth in absorption field before test In. Water added gal. New depth In. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) N if yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) 'Pump on' level at _ in. 'Pump off' level at —in. High water alar level at In. Datum Cycles tested Meets alarm 8 circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot >100, On adjacent lots %10(r Absorption field on lot >100' On adjacent lots >10a Public sewer main N/A Public sewer manhole/cleanout NIA Sewer/septic service line >26 Holding tank N/A Animal containment areas None Manure/animal excrete storage areas None SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation >s Property line>5' Absorption field >S Water main N/A Water service line >10 Surface water '100' Wells on adjacent lots >100' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property tine 6"" Building foundation >10' Water main >10' I Water Service line >10' Surface water >1W Driveway, parking/vehicle storage >25' Curtain drain None Noted Wells on adjacent lots >1001 F. COMMENTS: "'See Lot Line Welder. i it \\\fill G. ENGINEER'S CERTIFICATION =�Q�;:•"'��'•:;95�1� I that I have determined through field • •�9,�j i*491" certify inspections and '••• 1 49 review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. F«»..' Engineers Printed Name Michael E. Mderson, P.E. Q,.k���' Ate; � r CE -4381 Date V27/2010 S' L7"yV •� 4��G COSA Fee $ b s Waiver Fee $ Date of Payment r o D Date of Payment S �� Receipt Number()Y %7a Receipt Number (Rev. 11/05) q', 0 5 P/0106 V Municipality of Anchorage P.O. Box 196650 • 4700 Elmore Road Anchorage, Alaska 99519-6650 • (907) 343-7904 • Fax (907) 343-7997 http:1twww.m u ni.org1Onsite Development Services Department On -Site Water and Wastewater Program Ment Ueprrdnrnt **** VARIANCE/WAIVER REVIEW **** WR#: OSP101060 PID#: 015-231-86 HAM OSC101059 Permit#: SWO90071 Legal Description: Chickadee Slopes Tract A Lot 4B Engineer. Anderson Engineering Applicant: Micheal Quirk Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 6.0 feet. This waiver approval applies to the existing absorption field to property line separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ............................................................. a..... a ...... ..... Waiver Is Granted: X Waiver Is not Granted: Date: 6/9/2010 Approved by: &Z e/f y e of eviewer Ree#: 045211 Amount: $200.00 Date Paid: 5-27-10 **** VARIANCE/WAIVER REVIEW **** . oc 02'004 w 1 65. 03 ROC&R DGE�DRIVE_�_� � § Ln { § � Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program. 4700 Elmore Road P.O. Box 196650 Anchorage. AK 99507 Page of www.ci.anchorsge.ak.us (907) 343.7904 ONSITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number. SWO90071 PID Number. 015.231.86 wnr Michael Quirk Wastewater System: Q New ❑Upgrade gym.... P.O. Box 111398 Anchorage, AK 99511 ABSORPTION FIELD Pna,• 441-9352 Runo.r a "�• 4 O 0o" Tw OS"Teter 08w O Marr p Ddw LEGAL DESCRIPTION ° 1.2 TOW G•Maanap12.d. GPOSt' n. aiaa� X48 Chickadee Slopes Gwnco-a earan8 � Gr.wd.pnwwFnP4 Ff. n To.n4vP: Rrp. Satan Fr Wad •Eow aper T•d• Grn lupn: 0 to .1 F, 50 n. Well: © New ❑ Upgrade Gmv 5 ra.no.ralmh 2 Dr �rra >10 F,. Ft C4vrnura+(Fnv-u. A a Q: Tar DOM. Crrd b: Tar r4apom M Pp mxt W Private 206 Ft.58.32 Ft 500 Fp ASTM D3034 PVC Pvw D•u DVNdd smc wra L n w DW IMW.d. M -W Drilling 720109 61 n Sanders E Sanders 7/16.17109 Yra: Pup So L.rna �•F'V'1 tFPv. Gaub. TANK 5 GP4 Fr. 2 Ft SEPARATION DISTANCES 0 Septic ❑ Holding ❑ S.T.E.P. [3 Other. To Septic Absorption Lift Holding lublic4privitte From Tank Field Station Tank Sr rtine Anchorage Tank 11,250 Gr. M• M aCaryrownu. VM >100' >100' WA WA >29 Steel Two (2) swf.o wFvw >100, >100' WA WA LIFT STATION LAX LM >5' 6'— WA WA Gr 'P,mp ar Antir. 'PnW FR'I..r•t Man vnur rrma FPaWuon >5' >70' WA WA h_ k yv cwnonin None Noted Pune Ora 6 4odr EI•Nbi n.P.FEa,F pe V M R —See Lot Line Waiver. BENCH MARK Wraan rq D.wgam. Garage Slab w .tion. 100.0 FI Engineef Stamp Stamp Inspections performed by: A. Harala Dates: 1r 7116/09 ���� 1 7/17/09 �'QSII, Development Services 2nd Department Approval = �P:�O•F•.'�' •;�*� vj�• *' 49� Conditional Approval Date: «... ... ... . .. .. .............. ,V°. ;wvcua ! ANcfItSOH:W "�,:CE-4381 ..•.i`r� 09,9 –%(� Reviewed and approved by: Date: 11 6 P,par t SS10\�� 0 CD Cll IA •�. �• a 3N80 3001WIDO ! 4Wa Ye • •• _ •. z I k'' Imo cd. so d LO'S9l M .SC .l0 00 NL� � u � • %Q: toI.7 u Ne i i p O I ���L, 0\ • $i Z I .., % _ • I I 1 I Z \ Z 1O u \ ico --------------- tz N n n o>Y W via J r a Q Q N f --i _ W W n a In o O oOw 8 ;uZo V)U+ n I� � W u Q a M 0 < UJ OV) = a 0 p a n om Y Q U_ E J w = Z H o U 0 1..1... r,m �amr,m In 0 gm 5 (A W 1N3I13SY3 AL LL1 m a E SO'99l M ,00 .LO 00 N z .r EL Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519.6655 - 343-7904 Onsite Wastewater Disposal System or Well Inspection Report Permit Number. SWO90071 5 00.5 N N / F.4 E." 1 1,250 Gallon t n Septic Tank .9 5.7 Page 3 of 3 PID No. 015-231-86 25' (Trench Length) WEST TRENCH N ro 98.6 s 3.2 90.4 N 98.6 5/12/09 EAST TRENCH PROFILE AS -BUILT No Scale ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (F May 27, 2010 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Tract A, Lot 4B, Chickadee Slopes Subdivision Separation Distance Waiver Absorption Trench to Lot Line Dear On Site Services Engineer: The lot line was not clearly marked during construction of the absorption trenches on Tract A, Lot 4B, Chickadee Slopes Subdivision. The westernmost trench was inadvertently placed at 6' from the north property line. Placement of the absorption trench at this location will not adversely affect neighboring lots. The well on the lot to the north is more than 170' away and the septic system on the lot more than 50'. We hereby recommend a lot line waiver be issued allowing placement of the absorption system at 6' from the north lot line. Sincerely, Michael E. Anderson, P.E. V: -A.._ E. A♦JL3cQ> MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT 4B, CHICKADEE SLOPES SUBDIVISION PERFORMED FOR. MICHAEL QUIRK DATE: 7/16/2009 PROJECT No.: PARCEL IDB: TECHNICIAN: A. HARALA DEPTH TEST HOLE 3 (IS) 1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 17 18 19 4" d. OG/OL POORLY GRADED SAND WITH SILT SP/SM BOH @ 12.0' SITE PAN SEE SITE PLAN Y WAS GROUND WATER ENCOUNTERED? No IF YES @ WHAT DEPTH' DEPTH OF WATER AFTER MONTTORING: DATE OF MONITORING: DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH To WATER (INCHES) NET DROP (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 7/16 1 8:14/8:24 10 2,25/10.5 8.25" 2 8:26/8:36 10 2.12/10.25 8.13" 3 8:37/8:47 10 2.00/10.00 8.00" 4 8:50/9:00 10 2.25/10.25 8.00" 5 9:02/9:12 10 2.12/10.12 8.00" 6 9:14/9:24 10 2.25/10.25 8.00" PERCOLATION RATE•, 1.3 (MN/INCH) PERC. HOLE DIA.6 CHES) TEST RUN BETWEEN• 11 A FT. end 12.0 FT. COMMENTS. TEST HOLE PRE SOAKED PRIOR To TEST. TEST TO VERIFY SOIL CONDITIONS. SOILS SIMILAR TO TEST HOLE N0. 2. TEST PERFORMED BY ANDERSON ENGINEERING. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 5/27/2010 Job No. 09-116 WellOwner. Mike Legal Description: _ CN6 M -W Drilling, Inc. *P.O. Box 1103139 *Anchorage, AK 99511• •907-345-4000 ♦ 907-345-3287 Fax* GROUNDWATER WELL AS -BUILT & LOG Use of Well: Domestic Hale Depth: 206' Casing Size: 6' Cased To. 58.32 Drill Method: Air Well Completion: Open end X Screen/ Perforation descriptions Grout Notes: (3 ) Sack(s) of Bent Notes: Bedrock from 58' to 206' Material: A 53 Steel GR B Wall: 250 Screen Perforated Perf. Method: Well Development Method Notes: Static water level (SWQ 61' below top of casing (TOC). Well yield test at 5 Gals. per minute (GPM) for 1 hour(s) with S00% of drawdown (DD) from static level(SWL). Method: Air Lift Start Date: 7/17/09 Completion Date: 7/20/09 Pump Install Date: WELL OG Depth in feet from top of casing. Details of formations penetrated, size of material, color and miscellaneous details. 0 TO 3 Casing Stick Up 3 TO 57 Gravel, cobbly, silty 57 TO 206 Bedrock: bik siltstone argillite with small water seaps in To sporadic fractures TO TO TO TO TO To TBERG TO Presideni, M -W Orilling, Inc. A InCoUlcNalOW TO TO TO TO TO Development Services bepartment �.� Building Safety bivision On-Site Water & Wastewater Program o 4700 Elmore Road P.O. Box 196650 i Mark ch Anchorage, AK 99507 s "� Mayor www Muni OM/onsite (907) 343-7904 Pump Installation Log Well Drilling Permit Number: SW 090071 Date of Issue: 5/26/09 Parcel Identification Numbcr:015-231-86 Legal Description Chickadee Slopes Property Owner Name & Address: Michael Ouirk PO Box 111398 Anchorage. AK 99511 Pump Installation Date: 01/132010 Pump Intake Depth Below Top of Well Casing: 206 feet Pump Manufacturer's Name: Grunfos Pump Mode1:10SOEl330 Pump Size 1 (one) hp Pitless Adapter Burial Depth: 70 feet Pitless Adapter Manufacturer's Name: Unknown Pitless Adapter Installer: Unknown Well Disinfected Upon Completion? ❑ Yes 0 No Method of Disinfection: Comments: Pump Installer Name: M -W Drilling, Inc. Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation.