Loading...
HomeMy WebLinkAboutGLENN VIEW ESTATES WEST PH 2 BLK 2 LT 6Glenn View Estates West Ph 2 Block 2 Lot 6 #051-793-27 Municipality of Anchorage Page 1 of 3 Department of Health and Human Services Division of Environmental Services On-Site Services Section 825 "L' Street Room 502 P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW010050 PID Number 051-793-27 Name: MM&M Construction Wastewater System: New Address: P.O. Box 670495 Chugiak, AK 99567 ABSORPTION FIELD Phone: Number of Bedrooms: 688-1236 Four (4) Deep Trench - LEGAL DESCRIPTION Soil Rating: 8 GPD/Ft Total Depth from original grade: 11.5 Ft. Block: Lot: Subdivision: 2 6 Glenn View Est. West Phase II Depth to pipe bottom from original grade: 4.5 Ft. Gravel depth beneath pipe: 7 R. Township: Range: - Section: Fill added above oiginal grade: 0 Ft. Gravel Length: 55 Ft. Well: Community Water Gravel width: 3 Ft. Number of lines: 1 Distance between lines: N/A Ft. Classification (Private, A, B, 0): Class A Total Depth: Ft. Cased to: FL Total absorption area: 770 Ft' Pipe Material: ASTM D3034 PVC Driller: Dale Drilled: Static Water Level: Ft. Installer: MM&M Construction Date Installed: 6/26-30/01 Yield: GPM Pump Set at: Ft. Casing height Above Ground: Ft. TANK - SEPARATION DISTANCES n Septic • Holding ❑ S.T.E.P. 0 Other: To From Septic Tank Absorption Field Lift Station Holding Tank •ubliclPdvate Sewer Line Manufacturer' Anchorage Tank Capacity Gallons: 1,250 Wel >200' >200' N/A N/A >25' Material: .Steel Number of Compartments: Two (2) surface Water >100' >100' N/A N/A LIFT STATION — NONE ON LOT Lot One >5' >10' N/A N/A Size: Ga, Manufacturer: Foundation >5' >10' N/A N/A 'Pump on level at: in. 'Pump off- level at: in. High water alarm at: in. Curtain Drain None Noted Pump Make & Model Electrical Inspections performed by' 'Remarks: BENCH MARK Location and Description: Back Patio Door Stoop - Assumed Elevation: 100.0 Ft. c, n7jfitfls1Stam p Ot- Ai's:, e. 48'A�•• .- ix M n Inspections performed by: Mike Anderson Dates: 1a' 6/26/01'%` (ijo 71:::;,V 40TH v� 2 4 �°°`°� '°'y9' ' 4 2nd 6/30/010; ,.f�ykf f 4 it....,<,.. A, o MICHAEL E. ANDERSCN Department of Health and Human Services approval Reviewed and approved bG:iv [ Date: " /7-01 S 5,,:-. CE-4381 t4 aROFc5510 P .j' (Rev. 70/99) t7 W% ol. b.' September 10, 2001 Municipality of Anchorage Building Safety Division On -Site Water and Wastewater Program 4700 S. Bragaw Street Anchorage, AK 99507 Attention: Dan Roth Subject: Lot 6, Block 2, Glenn View West Subdivision Phase 11 Septic System Design Permit Number SW010050 Dear Dan: The location of the absorption trench for the subject lot was moved toward the back of the lot to allow more buffer between the front of the house and the roadway. A test hole was placed at the location shown on the site plan for the as -built which revealed identical soils to those shown on the test hole submitted with the design. A percolation test was performed at the new test hole and the results are attached. In addition, water monitoring at the new location revealed no groundwater. Placing the absorption system at the location shown will not conflict with wells or septic systems in the area. We therefore request the final location of the septic system be approved as submitted. Sincerely, Michael E. Anderson, P.E, Attachment Municipality of Anchorage DEVELOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK 99519-6650 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number SW010050 PAULA SUE CIRCLE 1 PID No. 051-793-27 Four Bedroom Home ilk c4 5 S1 ® M7 Alternate Site 10Landscape Easement 15' Utility Easement Page 2 of 3 81 S2 M1 C4 C5 38.1 30.2 40.9 25.5 40.4 PLAN AS-BUILT it"e .... e ,4=micHarti E. ANDERSON , "t-\ GE -43814 Co SCALE 1" = 40' 8 29.6 37.3 96.4 42.8 95.9 Municipality of Anchorage DEVELOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK 99519-6650 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number SW010050 PID No. 051-793-27 U 99.7 NMV UUU 2"" rns NMV• UU 1,250 95.9 / Gallon Se . Tank 99.2 Geotextile N x E 1. Fabric 95.7 Page 3 of 3 P8 81.2 55' PROFILE AS -BUILT 1"=10' 95.35 87.7 SaVAz OF 4/ 4cTH t�7J�%�° o -s C•` 9 . N;iCHAEL E. ANDERSON e 4, . CE -4381 if>F9f ., PROFESS\O 44. a AP se Rock cat iDrainfield 4 81.2 55' PROFILE AS -BUILT 1"=10' 95.35 87.7 SaVAz OF 4/ 4cTH t�7J�%�° o -s C•` 9 . N;iCHAEL E. ANDERSON e 4, . CE -4381 if>F9f ., PROFESS\O 44. a Municipality of Anchorage Department of Health & Human Services 825 L Street, Anchorage, AK 99502-0650 SOILS LOG - PERCOLATION TEST A O'r it r.r: Lao \ -... z. �frc.PFO Performed For: MM&M Contracting Date Performed: °fir,' 6OFESSO Legal Description: Lot 6. Block 2 Glenn View West Estates Phase II SLOPE TESTHOLE NO. 2 GM/SM Silty Gravel 6 with Sand Bottom of Test Hole Was Groundwater Encountered? North South No If Yes, What Depth? Depth to Water After Monitoring 713/01 Date: None S L 0 P E SITE PLAN See Site Plan Reading Date Gross Time Net Time Depth To Water Net Drop 1 26 -Jun 2:08 1.38" 2 2:38 3.5" 2.12" 3 3:08 5.75" 2.25" 4 3:09 1.5" 5 3:39 3.75" 2.25" Perc. Rate: 13.3 Min./Inch Perc. Hole Diameter: 6" Test Run Between 5 Ft. and 6 Ft. Comments: Perc. Cavity Presoaked Prior to Test. Test Hole Placed During Construction Performed By: Mike Anderson, I Michael E. Anderson Certify That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Date: 9/10/01 MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Permit Number: SW010050 Legal Description: Design Engineer: 0014 Anderson Engineering Owner Name: MM & M CONTRACTING Owner Address: P.O. BOX 670495 CHUGIAK , AK 99567 - This permit is for the construction of: Disposal Field ✓ Septic Tank Holding Tank (o/3o/&: fb:oom4 Date Issued: Apr 03, 2001 Expiration Date: Apr 03, 2002 Parcel ID: 051-793-27 Site Address: NI -IN PAULA SUE CIRCLE Lot Size: 40035 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 Privy Private Well Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 6-/5-O/ SEF_ EN6/ naR`S Ra✓r:Ea PE 516,1/ pc, TEC 6-/4-G/ A ?T4cR6-D. Received By: Issued By: Date: ' 3°'0 Date: 4 -3 -01 Parcel I.D. Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING on -793 -2.7 Permit Number SW O/005'O Property owner(s) MM&M Contracting Day phone 688.1236 Mailing address (1) P.O. Box 670495 Chugiak, AI( 99567 Mailing address (2)/V//A/ P99tjt19 5tE C /RCLE1 Zip Code 79517 Legal description (Lot, Block & Sub'd.) Lot 6, Block 2, Glenritiew Estates West Subdivision Phrw2 Legal description (Section, Township & Range) Lot Size 40 037 Acre•/Sq.Ft. THIS APPLICATION IS FOR: Sewer Only Sewer and Well Sewer Upgrade THIS PROPERTY CONTAINS: Hot Tub Swimming Pool Therapy Pool Number of Bedrooms Three (3) Well Only Water Storage n C ❑ Jacuzzi ❑ ❑ Water Softening Unit (l n I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: t ClIXJ Date of Payment: Receipt Number: (Rev. 12/00) Gal °0t Waiver Fees: Date of Payment: Receipt Number: MEMORANDUM DATE: June 16, 2001 TO: Dan Roth l ,� FROM: Mike Anderson, P.E!' cAs4— SUBJECT: Lot 6, Block 2, Glennview Estates West Subdivision Phase II Septic System Design Revision Permit No. SW010050 We have revised the design for the septic system for Lot 6, Block 2, Glennview Estates West Subdivision Phase II to include a four-bedroom system as opposed to the original design which was for a three-bedroom home. The new design includes a 1,250 gallon septic tank and a 54' long x 3' wide x 7' effective depth absorption trench. The attached Site Plan shows the location and dimensions of the new system. As with the original design the new system will not conflict with wells or septic systems on neighboring lots. Please review the attached design revision and modify the permit to allow the new septic system design. Thank you for your assistance with this modification. March 21, 2001 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 6, Block 2, Glenn View Estates West Subdivision Phase II Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 6, Block 2, Glennview Estates West Subdivision Phase II intends to construct a new four-bedroom home on the lot. The lot is currently vacant and all adjacent lots in the new subdivision are also currently vacant. We are hereby applying for a permit to construct a new septic system on the lot to serve the new home. The attached Site Plan and backup documentation identify the location and configuration of the new septic system and the parameters used in the design. It also shows the location of the alternate site and the water service line proposed for the lot. Existing drainage patterns are also shown and will not be altered by the development of the lot. Several test holes have been placed in the subdivision over the past years. All of these holes reveal well to poorly graded gravels with sands with percolation rates between 3 and 21 minutes per inch. A test hole at the proposed location for the new absorption trench revealed silty gravel with varying degrees of sand. No groundwater was noted in the test hole during excavation and none was noted during the monitoring period. We are therefore proposing to place a 3' wide by 54' long absorption by 7' effective depth absorption trench to treat the septic effluent. The pipe will be placed at 3' below the existing ground surface and the total depth of the trench will be 10'. A minimum of 3' of cover will be placed over the bed to prevent frost penetration and possible freezing. The ground surface on the lot slopes as shown on the attached Site Plan with a slight grade from east to west. The area for the new absorption trench, however, is fairly flat. The new trench will be constructed parallel to the contours of the surface in conformance with Municipal requirements. Grading will be accomplished to assure surface drainage is away from the new trench. The existing drainage pattern on the lot will not be affected during development. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The subdivision is currently Lot 6, Block 2, Glennview Estates West March 21, 2001 Page Two served by a community water system. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, ciliaLAL Michael E. Anderson, P.E. Attachments c nWs_ -7,`0 miGIR n E. ANDERSON #4,%fP ^ CE 4381 PROFESSION PAULA SUE CIRCLE cI n m 1 \P\ Four Bedroom House 01,250 Gallon Septic Tank Alternate Site 454' Long X 3' Wide X 7' Effecti e Depth Absorption Tr-nch do LOT 6, BLOCK 2, GLENN VIEW ESTATES SUBDIVISION PHASE 2 SITE PLAN SCALE 1" = 40' ",F OF f ;* 49IEt4,4 4 A 0 MfCHAfL E. ANDERSCN -: CE - 4381 t s lat®� ®tea • LOT 6, BLOCK 2, GLENNVIEW ESTATES WEST SUBDIVISION PHASE II DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom Home Perc, Rate: 6-15 Min./Inch Application Rate: .8 GPD/SF Deep Trench System 1,250 Gallon Septic Tank 7' Drain Field Rock 4 Bedrooms X 150 GPD / .8 GPD/SF = 750 SF of Absorption Area 750 SF/14SF/LF = 53.6 LF Trench Length Therefore: Construct an Absorption Trench 54' in Length by 3' Wide With 7' of Drainfield Rock Beneath the Distribution Lateral. Distribution Lateral to Be Placed 3' Below Existing Ground. Total Depth of Trench to Be 10' from Existing Surface. Mound Over Trench if Necessary to Provide Minimum Cover of 3'. Natural Backfill Geotexti.le -Fabric 4" Perforated PVC (Slots Down) NOTE: 7'_0" Drainfield Rock TYPICAL DEEP TRENCH SECTION (NO SCALE) Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 10' Separation From Lot Line. Minimum 4' Separation From Groundwater. Minimum 10' Separation From Water Service Line. Minimum 50' Separation From Break in Grade >25% l iH E> v.Te6.s8Fe7i las 1.yG1(/f}!d� +f C:• �'C MiCHAEL E. ANDERSON f ^' CE -4381 Municipality of Anchorage Department of Health & Human Services 825 L Street, Anchorage, AK 99502-0650 SOILS LOG - PERCOLATION TEST Performed For: MM&M Contracting Date Performed: Legal Description: Lot 6. Black 2. Glenn View West Estates Phase II SLOPE OG/OL TESTHOLE NO. 1 GM/SM Silty Gravel with Sand Bottom of Test Hole Was Groundwater Encountered? If Yes, What Depth? North South No Depth to Water After Monitoring 3/10/01 Date: None S L 0 P E eco! cs cc, 0 P, oMiCHAEL E. gt�DERSG`i•151 #6' CE -4381 $ffy`D • 10/41£411t,‘"» SITE PLAN k PROFESS \N See Site Plan Reading Date Gross Time Net Time Depth To Water Net Drop 1 19 -Oct 10:15 2.13" 2 10:45 4.5" 2.37" 3 11:15 6.75" 2.25" 4 11:16 2" 5 11:46 4.25" 2.25" Perc. Rate: 13.3 Min./Inch Pere. Hole Diameter: 6" Test Run Between 5 Ft. and 6 Ft. Comments: Perc. Cavity Presoaked Prior to Test. Test Hole Deepened During Construction Performed By: Mike Anderson, I Michael E. Anderson Certify That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Date: 3/21/01 Municipality of Anchorage Department of Health & Human Services 825 L Street, Anchorage, AK 99502-0650 SOILS LOG - PERCOLATION TEST Performed For: MM&M Contracting Legal Description: )mot 6. Block 2. Glenn View West Estates Phase II SLOPE tltiS °" Jg to 49TH %iv 01 070 MICHAEL E. ANDERSCN =� ®® Jl°°° CE -4381 C4 F9F°•. °' kms® jp 4444PROFESSI % * 1 MMe Date Performed: OG/OL TESTHOLE NO. 1 GM/SM Silty Gravel with Sand Bottom of Test Hole Was Groundwater Encountered? If Yes, What Depth? Depth to Water North South No After Monitoring 3/10/01 Date: None S L 0 P E SITE PLAN See Site Plan Reading Date Gross Time Net Time Depth To Water Net Drop 1 19 -Oct 10:15 2.13" 2 10:45 4.5" 2.37" 3 11:15 6.75" 2.25" 4 11:16 2" 5 11:46 4.25" 2.25" Perc. Rate: 13.3 Min./Inch Perc. Hole Diameter: 6" Test Run Between 5 Ft. and 6 Ft. Comments: Perc. Cavity Presoaked Prior to Test. Test Hole Deepened During Construction Performed By: Mike Anderson, 1 Michael E. Anderson Certify That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Date: 3/21/01 Try. 1N D ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 a 10i392FEE 31999 Performed for: SOILS PERCOLATION TEST 1*j.9TH ,p S. CE 7776�� '" `.... o % �(ennein K Dull • I Gregory Strong Date Performed: iklatROFESsk001' 10/2/ nIaNsy Project: SE1/4, SE1/4, SEC 4, T15N, R1W, SM TEST HOLE # 98-3 ORG -SM - reddish brown soft, loose SM/GM — brownish medium dense to dense S.O.H. SEE ATTACHED SITE PLAN FOR HOLE LOCATION Was Ground water encountered? NO What depth? NA Depth to water after monitoring? DRY Date? 10/9/98 Reading Date Gross Time Net Time Depth to Water Net Drop 1 10/9/98 9:47 - 6" - 2 10:17 30 min 2" 4" 3 * 10:18 - 6" - 4 10:48 30 min 2 3/4" 3 1/4" 5 * 10:49 - 6" - 6 11:19 30 min 2 3/4" 3 1/4" 7 8 9 10 11 12 * WATER ADDED Percolation Rate 9.2 (grin/in) Perc Hole Diameter 6" Test Run Between 3 feet and 4 feet I, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in effect on this date. Municipality of Anchorage On -Site Water & Wastewater Program (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 051-793-27 1. GENERAL INFORMATION Complete legal description Location (site address) 21200 PAULA SUE CIRCLE, CHUGIAK, AK 99567 Current Property owner(s) RACHEL POTTER Mailing address 21200 PAULA SUE CIRCLE, CHUGIAK, AK 99567 Real Estate Agent BOB RINK Day phone 261-7619 Expiration Date: 4-19-17 eha GLENN VIEW ESTATES WEST PHASE II; BLOCK 2, LOT 6 Day phone 529-1091 2. TYPE OF DWELLING: ▪ Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class Well Public Water System 4 TYPE OF WASTEWATER DISPOSAL: ❑ Individual On-site ❑ Individual Holding tank ❑ Community On-site 1111 Public Sewer WaiverNariance request for: N/A • Distance: - Received by: COSA to be released to the engineer, unless otherwise requested by the engineer. Date: /f���� COSA Fee $ '52.4 Date of Payment Receipt Number 61lS'16 COSA# 05°157/51 Klni<S c - Waiver Fee $ Date of Payment Receipt Number Waiver # S. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. 1 further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179 Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK, 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Engineer's Comments: In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system in accordance with the guidelines and regulations established by the Municipality of Anchorage and industry practices. The reported results describe the condition of the system/s on the dates of the evaluation. Separation distances were measured to readily identifiable features. Hidden defects or encroachments may exist that were not identified during the evaluation.The operational life of all wells and septic systems depend on a variety of variables including, but not limited to, soil conditions, groundwater levels (that may fluctuate during the year), quality of construction (materials and workmanship), and the water usage of the family utilizing the system's. These conditions can vary, and are outside the control of GEG. Satisfactory test results do not guarantee future performance of the system's; therefore, GEG makes no warranty (express or implied) regarding the future performance of the well or septic system. GEG makes no representation whether an alternative well or septic system can be installed on the property in the event either of the current systems fail The content of this report is for the sole benefit of the person/party who retained GEG. Reliance upon the information provided in this report by any other person or party, including but not limited to subsequent property purchasers, is not authorized. In short, GEG disavows any legal duty to anyone other than the person/party who paid for this repot. 6. DSD SIGNATURE VSystem #1 Approved for System #2 Approved for Disapproved. Conditional approval for bedrooms. bedrooms. Date gArk 3 •"�� �,Sillisl; \QL��V OF hyo/ IS ON-SITE 2- WATER AND bedrooms, with the following stipulations: t n WASTEWATER fl PROGRAM By: L(! . r Original Certificate Date: ( C1 1 The frlur4p= ity ar nchorage Develop, emt Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTCHMENTS: COSA Checklist Septic System Advisory Well Flow Advisory (Rnv 10x19119, Nitrate Advisory Arsenic Advisory Other If more than 1 septic system is on the lot: COSA Checklist # of Structure served by this system Certificate of On -Site Systems Approval Checklist PA 2— Legal Description: GLENN VIEW ESTATES WEST PHASE II; BLOCK 2, LOT 6 Parcel ID: 051-793-27 A. WELL DATA PUBLIC WATER If A, B, or C provide PWSID# _ Well Log (Y/N) Date completed Sanitary seal (Y/N) Wires properly pr. - -d (Y/N) Total depth ft. a -, o ft. g height (above ground) in FROM WELL LOG AT INSPECTION Date of test Static water leve ft. roduction g. p. m. WATER SAMPLE RESULTS: Coliform gpm PUBLIC WATER cotoniesI400-m1 Nitrate mg./L B. SEPTIC/HOLDING TANK DATA Date of sample: Tank Type/Material SEPTIC/STEEL Date installed 6/26-30/2001 Tank size 1250 gal Number of Compartments 2 Cleanouts (Y/N) YES Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO High water alarm (Y/N) N/A Date of pumping 4/10/2015 Pumper JR'S PUMPING C. ABSORPTION FIELD DATA Date installed 6/26-30/2001 Soil rating (. Length 55 ft. Width I`BELOW EXISTING GRADE ft2/bdrm) 0.8 System type DEEP TRENCH 3 ft. Gravel below pipe 7 ft. Total depth 10.9 ft. Eff. absorption area 770 ft2 Monitoring tube YES Depression over field NO Date of adequacy test 4/14/2015 Results (Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test 60 in. Water added 1026 gal. New depth *80 in. 215/ 81.5/ Elapsed Time: 1150 min. Final fluid depth 73.5 in. Absorption rate >= 600+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN If yes, give date *1/2" OF WATER IN CO NEXT TO MONITORING TUBE. CO ON OPPOSITE END WAS DRY. D. LIFT STATION Date installed "Pump on" level at in. "Pump of level at Cycles tested Size in gallons Manhole/Access (Y/N) alarm level at in Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: ift station on lot Absorption field on lot Public sewer main PUBLIC WATER On adjacent lots On adjacent Tots Sewer /septic service 0 containment areas c sewer manhole/cleanout Holding tank Manure/animal excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main 10'+ Water service line 10'+ Surface water 1004 Wells on adjacent Tots 100'+ PVT. & 200'+ PUBLIC SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 101+ Building foundation 10'+ Water main 101+ Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ PVT. & 2001+ PUBLIC F. COMMENTS AS -BUILT SURVEY IS ON FILE AT MOA. A +" ueb Purr ibJ(r izezeler G. ENGINEER'S CERTIFICATION 1 certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this . date. �• Engineer's Printed Nagre JEFFREY A. GARNESS �• •� Date fC/.( (Rev. 10/12/12) 0 •• Gor-essf i CE -• �PROF.-ES (Oise Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. C °13 _a2 1. GENERAL INFORMATION Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address COSA# 0°103 7 - Expiration Date: / U -- / 6 / 0 GLENN VIEW ESTATES WEST, PHASE 2; BLOCK 2, LOT 6 21200 PAULA SUE CIRCLE * CHUGIAK, AK * 99567 FORECLOSURE Day phone Day phone BOB RINK W/ DYNAMIC PROPERTIES Day phone 261—'7619 3111 C STREET * ANCHORAGE, AK * 99503 Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class Well Public Water System 4 TYPE OF WASTEWATER DISPOSAL: l♦ Individual On-site ❑ Individual Holding tank ❑ Community On-site ❑ Public Sewer • The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of'On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179 Name of Firm 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AI< 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Address Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. Theoperational levels thfe at all wells is and septic systems depend on the local soils condition, groundwater fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. 5. DSD SIGNATURE Approved for 1 bedrooms. Disapproved. Conditional approval for Date 13114ID�a D OI e /0/t ►.ccw� ��eCr o ,2: ON-SITE G- `' WATER AND .. m WASTEWATER : PROGRAM : v-0 r NTSENC�0) bedrooms, with the fllowing stipulations: t'rofessio� buil,,. �°o.. OF qNr . . •T, •ltttll�, Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory By: 1/7, (Rev. 11/05) ) /o Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date: 0/6-09 A. Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: WELL DATA Well type Date completed Total depth GLENN VIEW ESTATES WEST, PHASE 2; BLOCK 2, LOT 6 ft. If A, B, or C provide PWSID# Sanitary seal (Y/N) Cased to ft. FROM WELL LOG Date of test Static water level ft Well production WATER SAMPLE RES g.p.m. Parcel ID: OS/ 7 1 3 - "27 PUBLIC WATER Well Log (Y/N) Wires properly protected (Y/N Casing height (ab ATI CTION ound) ft. Coliform colonies/100 ml. Nitrate mg./L. Other bacteria g.p.m. in. colonies/100 ml. epic: ug./L. Date of sample: Collected by: B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Date installed 6/26-30/2001 Tank size 1250 gal. Number of Compartments E Cleanouts (YIN) YES Foundation cleanout (Y/N) YES Date of pumping 1 U/' / v el Depression over tank (Y/N) NO High�water alarm (Y/N) Pumper San; k�t I'uvt,c trS C. ABSORPTION FIELD DATA ]•BELOW EXISTING GRADE] Date installed 6/26-30/2001 Soil ratingq(�.p.d.2 or ft2/bdrm) 0.8 Length 55 ft. Width 3 ft. N/A System type DEEP TRENCH Gravel below pipe Total depth 10.8 ft. Eff. absorption area 770 ft2 Monitoring tube YES Date of adequacy test **10/2/2009 Results (Pass/Fail) PASS Fluid depth in absorption field before test 30 in. Water added 1260ga1. Elapsed Time: 240 7 ft. Depression over field NO For 4 bedrooms New depth 65 in. min. Final fluid depth 61 in. Absorption rate >= 600+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN If yes, give date **HOUSE WAS VACANT AT TIME OF TEST. PRESOAKED ON 9/30/09 WITH 2000 GALLONS OF WATER. D. LIFT STATION Date installed Size in gallons "Pump on" level at in "Pump off level Datu E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot Absorption field on lot Public sewer main Sewer /septic service line containment areas Manhole/Access (Y/N High water alarm level at in. Cycles tested Meets alarm & circuit requirements? On adjacent lots On adjacent lots sewer manhole/cleanout Holding tank Manure/animal excrete storage areas PUBLIC WATER SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field Water main 10'+ Water service line 10'+ Wells on adjacent lots 200'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: 5'+ Surface water 1 00'+ Property line 10'+ Building foundation 10'+ Water main Water service line 10'+ Curtain drain NONE KNOWN F. COMMENTS Surface water 100'+ 10'+ Driveway, parking/vehicle storage 10'+ Wells on adjacent lots 200'+ G. ENGINEER'S CERTIFICATION 1 certify that t have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's PrintedlName JEFFREY A. GARNESS Date IOf4 04 4p rness: C%mp0 fe �e E aprofeselo,.00� �D00000�� COSA Fee Date of Payment Receipt Number 0 (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FORA SINGLE FAMILY DWELLING Parcel I.D. 051-793-27 1. GENERAL INFORMATION HAA# /74-Mmala Expiration Date: -J9 - = 02 Complete legal description Lot 6, Block 2, Glennview Estates West Subdivision Phase II Location (site address or directions) 21200 Paula Sue Circle Current Property owner(s) Mark and Carol Woods Day phone 688-7512 Mailing address 21299 Paula Sue Circle Chugiak, AK 99567 Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class Well Public Water System Four (4) TYPE OF WASTEWATER DISPOSAL: Individual On-site Individual Holding tank Community On-site Public Sewer n The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C'well and may be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage Is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Address P.O. Box 240773 Anchorage, AK 99524 Phone 522-7773 Engineer's Printed Name Michael E. Anderson, P.E. Date 6121/2002 5. DSD SIGNATURE Approved for L74- bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: Additional Comments LoV J2•' ON-SITE •�- WATERANLL: m WASTEWATER PROGRAM ` JIO.f� • e .O~\\\ JJJJ� ENT SEMS Attachments: HAA Checklist Septic System Advisory Weil Flow Advisory X Maintenance Agreements Supplemental Engineer's Report Other BY 77/7/2._7 t K / cC" Original Certificate Date: to Rev. 12100) Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: Lot 6, Block 2, Glenn View Estates West Phase II Parcel ID: 051-793-27 A. WELL DATA Well type AWWU If A, B, or C provide PWSID # Well Log (Y/N) Date completed Sanitary seal (Y/N) Wires properly protected (Y/N) Total depth ft. Cased to ft. Casing height (above ground) in. FROM WELL LOG AT INSPECTION Date of test Static water level ft. ft. Well production g.p.m. g.p.m. WATER SAMPLE RESULTS: Coliform colonies/100 ml. Nitrate mg./I. Other bacteria colonies/100 ml. Date of sample: Collected by: B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Date installed 612612001 Tank size 1,250 gal. Number of Compartments 2 Cleanouts (YIN) Y Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N Date of pumping Pumper Recent Construction C. ABSORPTION FIELD DATA Date installed 6130!2001 Soil rating (g.p.d./f2 or ft2/bdrm) .8 GPD/SF System type Deep Trench Length 55 ft. Width 3 ft. Gravel below pipe 7 ft. Total depth 11.5 ft. Eff. absorption area 770 ft2 Monitoring tube Y Depression over field N Date of adequacy test Results (Pass/Fail) For bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date g.p.d. D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) High water alarm level at Meets alarm & circuit requirements? "Pump on" level at in. "Pump off" level at _ in, in. Datum Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot On adjacent lots Absorption field on lot On adjacent lots Public sewer main Public sewer manhole/cleanout Sewer /septic service line Holding tank SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5' Property line >5' Water main N/A Water service line >10' Wells on adjacent lots >100' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 5' Absorption field >5' Surface water >100' Building foundation >10' Water main >10' Water Service line >10' Surface water >100' Curtain drain None Noted Wells on adjacent lots >200' F. COMMENTS S Health Authority was issued on this property in October of 2001. House year ago. Driveway, parking/vehicle storage >10' has been occupied only 8 months. Constructed less than 1 sswike II 4. . 91: . t ' �,k�4#9 G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA HAA guidelines in effect on this date. Engineer's Printed Name Michael E. Anderson, P.E. Date 6121/2002 HAA Fee $ 375 tfri— �• s�oA g*: 49=w � I# "" ••M!CHA _E 1',� ERSC,N • •. 2. ° ;c. !40 1 "`„�' V. S .1/ 47 a Li f<qF •" �\a' i> °`C .4 @4 "frESSI0I °w' Date of Payment Receipt Number (Rev. 12/00) 6—t1 -oz 2144-2, Waiver Fee $ Date of Payment Receipt Number ROM : CeUNT.Y RERLTY PHONE NO. : 9076881238 5vr?. " ... Sep. 10 2001 08:44RM P1 -1 GPA s,. r• le Wyo., ," 3<�a Rye •'•-« 400 Y .:.o z3a ..4 h7 ✓44..5 Vis.` .a....'::.�.: Received Time Sep•10• 9:O1AM Ihereby entity that FJ ave aegyed ihe.£onQvmg des:. t, At::ltaragrc. rding, RecoPie. Alaska and that. the improve,,, amts st ammo thter. maroon are wiitthin. the propertylines and do iot ovllapot a nap$tjj an the property lye adjacent theteto'';fhab'. no improvemerds on property tying adjacent thereto.enctoach on the premises in question and that -there are no roadways,?,' transmission Tinea or other ale* easements on said property except as iztdirated hereon. Dated at Eagle Riva: Aknaka this 7-5^Th• Oaf TO lY zoJ • SCALEROBERT C. JOHNSON -R : I„ SCALE: SurroyortJo.880-L5BOX 77-0456, `' River„ Alaska :99571 Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING HAA # /1/4ofb1/6/3 Parcel I.D. 051-793-27 Expiration Date: C% — I % - 1. GENERAL INFORMATION Complete legal description Lot 6, Block 2, Glenn View Estates West Subdivision Phase II Location (site address or directions) Paula Sue Circle Current Property owner(s) MM&M Construction Day phone 688-1236 Mailing address P.O. Box 670495 Chugiak, AK 99567 Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: Four(4) 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class A Well Public Water System TYPE OF WASTEWATER DISPOSAL: ❑ Individual On-site ❑ Individual Holding tank Community On-site ❑ Public Sewer The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. 5. DSD SIGNATURE 1/ Approved for ¥ bedrooms. Disapproved. Phone 522-7773 Date 9110/01 Conditional approval for bedrooms, with the following stipulations: Additional Comments il WATER AND • WASTEWATER °. PROGRAM Attachments: HAA Checklist X Maintenance Agreements Septic System Advisory Supplemental Engineer's Report Well Flow Advisory Other BY: So/ G✓. i" cret (Rev. 12100) Original Certificate Date: 9 — / 7- 0 / Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: Lot 6, Block 2, Glenn View Estates West Phase II Parcel ID: 051-793-27 A. WELL DATA Well type A If A, B, or C provide PWSID # Well Log (Y/N) Date completed Sanitary seal (Y/N) Wires properly protected (Y/N) Total depth ft. Cased to ft. Casing height (above ground) in. FROM WELL LOG AT INSPECTION Date of test Static water level ft. ft. Well production g.p.m. g.p.m. WATER SAMPLE RESULTS: Coliform colonies/100 ml. Nitrate mg.A. Other bacteria colonies/100 ml. Date of sample: Collected by: B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Date installed 612612001 Tank size 1.250 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout (Y/N) Y Depression over tank (YIN) N High water alarm (Y/N) N Date of pumping Pumper C. ABSORPTION FIELD DATA Date installed 6130/2001 Soil rating (g.p.d./ft2 or ft2/bdrm) .8 GPD/SF System type Deep Trench Length 55 ft. Width 3 ft. Gravel below pipe 7 ft. Total depth 11.5 ft. Eff. absorption area 770 ft2 Monitoring tube Y Depression over field N Date of adequacy test Results (Pass/Fail) For bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date g.p.d. D. LIFT STATION Date installed Size in gallons "Pump on" level at _ in. "Pump off' level at in. Datum Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot On adjacent lots Absorption field on lot On adjacent lots Public sewer main Public sewer manhole/cleanout Sewer /septic service line Holding tank SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Manhole/Access (YIN) High water alarm level at in. Meets alarm & circuit requirements? Building foundation >5' Property line >5' Water main NIA Wells on adjacent lots >100' Absorption field >5' Water service line >10' Surface water >100' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line >10' Building foundation >10' Water Service line >10' Water main >10' Surface water >100' Driveway, parking/vehicle storage >10' Curtain drain None Noted Wells on adjacent lots >100' F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that t have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA HAA guidelines in effect on this date. Engineer's Printed Name Michael E. Anderson, P.E. Date 911012001 APV t RP' •AS F F ..Mt ICH E L thts .a FC. , CE 'MVP #m00 :k6FESS10 s;c;—' HAA Fee $ ")1 `3 Date of Payment q ti; o5 Receipt Number (Rev. 12/00) t_UDOH Waiver Fee $ Date of Payment Receipt Number