Municipality of Anchorage
I• Development Services Department
Building Safety Division
On -Site Water and Wastewater Program, 4700 Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650 Page 1 of 2
www.ci.anchorage.ak.us (907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number. S ty O Ks 7 PID Number. Or 8 - 'Yo1 - 16
No"
Eric L.a+l erten
Wastewater System: ❑ New ® Upgrade
Ada•ss
Y/�1 DeArA•oe.n ltd. Maul. A4 9eS/6
ABSORPTION FIELD
Pl *7 Ys•-.i69i .Y of eMaaas
5fD••p Twin D Shatlaw Trent D Bed D Md O ott'W
Sod Rating-
Tom Dean ham ",,@1 paw'
LEGAL DESCRIPTION
0.6 GPDIF1'
I&. e FI.
81x La Stodmrorr.
DWh to ppe Dpnpm Dam agrW pad•.
Greer aWh Dwain ppe:
1 OeArw10aan
I. I/ Ft.
'• Z FI
7~,r p Ratge Sw m.
Fe ad•d mwa ongnr pw
C✓" Largln:
0•S FI.
S•• FI.
Well: EKA.rr []New ❑ Upgrade
2.S
Nu iad nes
/
Dutrroa Drw..n l•u
FI.
Ft
Cosemaattm (Prone, A B, Cf.
Total Dean.
cased w:
Tar •Dsorp o nes
Ptpa Mrenr F•-BlO Perf
FI.
I FI
781 FT
V-To?f no^•Pe-f
DrAw
DO. Dried
Staw Wnat LevrMlrw
ACjI 6Af•
Date M•Nred /
0/y loo
Fl
exon
vwd
Pump San
C.sag Negm AD G,
TANK
GPM
FL
FI
SEPARATION DISTANCES
91 Septic ❑ Holding ❑ S.T.E.P. ❑ Other.
To
Septic
Absorption
Lit
Holding
umcrPnvate
saoa.
ap.utr
From
Tank
Field
Station
Tank
Sewer Line
G JIteA
I ZSi7 Gr.
www
Nu a Gdnpalmam
Was
lO3
116
—
—
7ZSA
She t/
2
sa.awra
1,,,1
len•
_
-
LIFT STATION /vA}•
a..
.aver.
La Los
1 y'
11'
-
-
Gr
'Fury an' leer at.
'Pump of Mw a
Hgh wan ram at
Fandran
in
Pump Max• a Mair
Ewahcr aspaawns WM b/
Curran Drrn
_
_
_
Ftw n s II /
t "taf-11Pel Y Cfl� Pbef 0^&IyICW
BENCH MARK
4Otr xr4Nc k4mL- a X eni 4es Iae
lorauon rb Desaqum.
(js/Cje ea olA G/- N u/
sumed uwum.
�� `` J
�!-•r !off ^w 1t %' I•^Yet' %+1e lnl.
l
�Oe/I l/` Or �0. %DO.O Ft
F e roma 019601johiso
Engineer's Stamp
Inspections performed by: rlaFfry Tech Sve Dates: 1" e/ Z/a C
2nd&/J /Ol,t
- y ApO.V.U%>ti
pF•'•:
Development Services Department Approval:'
p•��
Conditional Approval Date:
,;." �? ASItH I -A
�•, _� THEODORE F. MOORE �•
(� n�0%
Date
T,^ •. C0-3589
••seen c!
Reviewed and approved by:
�.�
PERMIT NO: SW060057
PID NO: 018-401-16
55'
I
NEW 1250 -GALLON
TSEPTIC TANK
NEW 55 -FOOT LONG t
"E^
SOIL ABS. TRENCH —1 "C"
"B" "F'
w. 7.2' EFF. GRAVEL
T.. HED
#1H
;
GROUND
SWING TIES:
ELEV. 96.0'
Y,e cr tty
FROM: COR. "A"
COR. "B'
COFi. "C' COR. "D"
TO:
." 1F
S.T. C.O."E" 63.5'
18•
29' '+
S.T. C.O. "F" 72.5'
10'
20.5' ^
DBL. C.O. "G" 74.5'
8.5'
18'
C.OJM.T. "H" 133'
INV. i r� '• �t ;
45' 17'
LOT 1
DEARMOUN S/D fi>
"A"
TBM
100'
PAGE 2OF2
PLAN VIEW
SCALE: 1" = 30'
DeARMOUN ROAD
N
G
c
C
4 FEET
SOILCOVER
GROUND
ELEV. 96.0'
Y,e cr tty
." 1F
ell
INV. INV.
1250-GALLONr
INV. i r� '• �t ;
„
93.2'
92.6'
SEPTIC TANK
t t ,�-
93.6 h
to .
55 -FOOT LONG
SOIL ABS. TRENCH
TMCDOR' F. A:OORE ,=
a .a CF - 3 S I ••fw
BOTTOM EXC.
ELEV. 85.4'
LOT 1, DeARMOUN SID
SEPTIC SYSTEM UPGRADE
BOTTOM T.H. #1 ELEV. 79.0
AS -BUILT INSPECTION REPORT
NO GROUNDWATER OBS.
CROSS SECTION
FLATTOP TECINICALSERVICES I SCALE:ASNOTED
NOT TO SCALE
14530 ECHO CANYON ROAD DRAWN BY TFM
,., .....�r
G
c
C
MUNICIPALITY OFANCHORAGE
Development Services Department
On -Site Water 8 Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 995196650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Upgrade
Date Issued: Apr 17, 2006
Expiration Date: Apr 17, 2007
Permit Number: SWO60057 Parcel ID: 018-401-16
Legal Description: Dearmoun Lot 1
Design Engineer: 0019 FLATTOP TECHNICAL SERVICES Site Address: 4001 Dearmoun Rd
Owner Name: Eric Lamberson Lot Size: 34500 SO. FT.
Owner Address: 4001 Dearmoun Rd Total Bedrooms: 4 Permit Bedrooms: 4
Anchorage , A 99516 -
This permit is for the construction of:
❑✓ Disposal Field 0 Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ).
3, The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:
Received
✓� �-
Date:
'C'
Issued By: �/�I
fl
Date:
1411-714b
Municipality of Anchorage
Development Services Department
Building Safety Division
% On -Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onsite
(907)343-7904
ON-SITE SEPTIC/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 0(0— YD l —16'
-
Property owner(s)
C r•1 c
La m S erYo,f
Day phone - v V 19
Mailing address
4YO01
Pe Ar'rnC'u^ R/4
Zip Code 99X"
Site address
Code
Legal description (Sub'd, Block & Lot) 1-6f ? . De -CIO
Legal description (Township, Section & Range)
Lot Size 3T 00 Sq. Ft.
THIS APPLICATION IS FOR (®all that apply):
Absorption Field
Septic Tank
❑
Holding Tank
❑
Privy
❑
Private Well
❑
Water Storage
❑
Number of Bedrooms
THIS APPLICATION IS AN:
Initial
❑
Upgrade
Renewal
❑
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
z a2�n/ '0;� -2;�
(Signature of property owner or authorized agent)
Permit/Rush Fees: %/6�O Waiver Fees:
Date of Payment: Y //7 /zoOr Date of Payment:
Receipt Number: D 7 7 % 7 L/ Receipt Number:
(Rev. 11/05)
FLATTOP TECHNICAL SERVICES,
CML & ENVIRONMENTAL ENGINEERING • ENERGY CONSERVATION & ANALYSIS
TED MOORE, P.E. 14530 ECHO CANYON ROAD
PHJFAX: (907)345.1355 ANCHORAGE, AK 89516
E -Mail: tgmooreftcl.net March 16, 2006
M.O.A. DSD
P.O. Box 19-6650
Anchorage, AK 99519
Dear Sirs:
The purpose of this letter is to provide the required design narrative in support of our application
for a permit to upgrade the wastewater disposal facilities on Lot 1 of DeArmoun S/D, located at 4001
DeArmoun Road. Soils logs, pert test results, a site plan, design drawings and specifications, as well as
a copy of the waiver application submitted to DEC, are enclosed for your review.
The proposed system will be constructed in the vicinity of test hole # 1. As can be seen from the
soil log, the native material between 1.5' and 17' below ground level is a silty gravelly sand with a
measured pert rate of 13 minutes per inch. Using the soil application rate of 0.8 gpd/sq. ft. specified in
the wastewater ordinance, this 4 -bedroom residence requires a total absorption area of (4 x 150)/0.8 =
750 square feet. The proposed 54 -foot long trench design with 7 feet of effective gravel has a total
absorption area of 756 square feet.
The topography of the lot in the area of proposed construction slopes down towards the south at
approximately 3%.
The proposed project will have no significant impact on present or future water supply and
wastewater disposal systems serving adjacent properties, nor will it have any significant impact on
reserved space -surface and subsurface, or on drainage.
Please give me a call at 345-1355 if you have any questions on this submittal.
Sincerely,
Ted Moore, P.E.
cc: Bill Reith, ADEC Wastewater Program
Eric Lamberson, 4001 DeArmoun Road
WELLS APPARENTLY SERVING
0
BOTH CABINS ON LOT 2
(L
CABIN,
LOT 2
0
DeARMOUN SID
Z =1
DRIVE 7.�-'
SEPTIC CAB X
SYSTEM GA
lZ
ABANDON EXISTING TRENCH
-...,�.Z.:ABANDON EXISTING -SEPTIC ,.TANK
R 15C
A
......-4
4: ------
T.H.
#1
LJ
cr (o
DRIVE
......... . ..... ... ...... INSTALL NEW
.
1260 -GALLON
0
SEPTIC TANK
z
PRIVATE WELL
......... SITE FOR R I
wCONSTRUC'T'
NEW REPL. TR.
rJ
64 -FOOT LONG SOIL
LOT I
ABSORPTION TRENCH
DEARMOUN S/D
P :3
IL
w. 7.0' GVL BELOW PIPE
rr)
..................
. ....... . . . ..
-------------------------C
DeARMOUN ROAD
------------------------------------------------------------------
, wol�'oft%k%
4406'
..A III
Ar
A -l-Apo 14,
LOT 1, DEARMOUN SID
SEPTIC SYSTEM UPGRADE
9
SITE PLAN
.........................
FLATTOP TrCHNICAL SERVICES 1 INCH = 50 FEET
.. ........
THE F. M E
0
14530EC110 CANYON ROAD DRAWN BY TFM
16. CE *
ANCHORAGE. ALASKA "516 MARCH, 2006
. .'. .6.
:slo
NOTE: THIS IS NOT A SURVEYED PLAT.
ALL LOCATIONS SHOWN ARE APPROXIMATE.
CONSTRUCT 54 -FOOT LONG
SOIL ABSORPTION TRENCH
w. 7.0' GRAVEL BELOW PIPE
4" DIA. F-810 PERF.
I1,Flhlm
54
PLAN VIEW
SCALE: 1" =10'
MONITOR
MOUND BACKFILL
FILTER FABRIC
4" DIA F-810 PERF. PIPE
12"-212"
BOTTOM OF EXCAVATION
INSTALL NEW
1250 -GALLON-----\
SEPTIC TANK
4" DIA.
D-3034
DBL.
C.O.
" C.O.
fit
7 1 7.5
THEODCRE F. MOORE ;
+'•, CE -3509 P``'
TRENCH
CROSS-SECTION
SCALE: 1" = 5'
LOT 1, DcARMOUN S/D
SEPTIC SYSTEM UPGRADE
PLAN AND CROSS-SECTION
FLATTOP TECIINICAL SERVICES SCALE: AS SI IOWN
14530 ECHO CANYON ROAD DRAWN BY: TFM
ANCIIORAGE. AK.99516 61ARC11. 2006
FLATTOP TECHNICAL SERVICES
14530 ECHO CANYON ROAD
ANCHORAGE, ALASKA 99516
TEST HOLE # 1 SOILS LOG — PERCOLATION TEST
LEGAL DESCRIPTION: LottDeArmoun S/D
DATE PERFORMED: _MarCh.6.2006
PERFORMED FOR: Eri_c_Lamberson
DEPTH PL
(t)
1 SM Reddish sarxly loam
2
3
4
5
6
8 -0 SM/GM Silty gravely sand w. boulders
Dry, very densely compacted
9- Non -cohesive but hard digging
11
12
13
14
15
16
17
18
19
20
B.H.
SLOPE
35
36
e.eI y
O A41�t
✓•• f
r ..........................0
THEODORE F. ,l'.00kE
CE -3589 p; L
'n'�°�>p.. ;r1!, 41
SITE PLAN '
T.H.
#1
Lot 1, DeArmoun S/D
DeArmoun Road
Date Reading
Clock Net Tine
Time (minutes)
Percometer
Reading
Net Drop
(Inches)
3/6!06 12" Presoak
-start
ter
wa1
water
#3
_
12:42PM
1.12 _ 30
1:12:4
1:42:45
1:43:30
2:13:30 13U
27 5/8
23-3/8
21
2
21 �11/8
1/8
23.71/16
21 3116
23/8
X18
-
PERCOLATION RATE__j3_ (minuteslBxh) PERC HOLE DIAMETER 6_
TEST RUN BETWEEN 6.0_FTAND__p,5_ FT
COMMENTS: Size absorption trench on basis of 0.8.gpd/sq. R.
PERFORMED BY FLATTOP TECHNICAL SERVICES. 1 J.a./� • w+ti.L CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: I I6 /O 6
(Tfattop 7uhnica[Senvices
14530 Echo Canyon 4j9a,(ylnch"e AX99S16
Qfrone (907) 345-135S
Lot 1, DeArmoun SID
4001 DeArmoun Road
Wastewater disposal system installation
Specifications
1.0 General:
1.1 The scope of the project consists of abandoning an existing steel septic tank and installing a
new 1250 -gallon septic tank that discharges effluent into a new 54 -foot long soil absorption trench
containing a total of 7.5 feet of sewer gravel.
1.2 Construction shall be as depicted on the approved site plan and design drawings. Minor
deviations from these drawings may be allowed or required by the engineer conducting the inspections.
All construction procedures and material specifications shall conform to Municipal and State
requirements. All separation distances shall be in conformance with Municipal requirements, unless
specifically waived. A waiver has been requested to allow installation 135 feet from the Class "C" well
on Lot 2.
1.3 The contractor shall be responsible to obtain any necessary utility locates, and to work
around any buried utilities.
1.4 Unless agreed otherwise, the contractor shall be responsible for any tree clearing and
grubbing necessary to complete the project. Prior to the start of excavation, the contractor shall cut
down and remove the branches of all trees larger than 6 inches in diameter and neatly stack these trees
outside the construction area. If requested by the property owner, the contractor shall then bury non -
detrimental branches, brush and roots generated by the construction work at a suitable site on the
property located no less than 10 feet away from all present and foreseeable construction areas. The
contractor shall neatly stockpile any detrimental material which cannot be buried, for subsequent
disposal by the property owner.
1.5 The contractor shall provide adequate cover material and rough grading over all system
components to ensure that proper drainage is achieved after settlement and that there are no residual
depressions. Insofar as possible the contractor shall minimize damage to trees and existing lawn areas.
1.6 Unless specifically agreed otherwise, the homeowner shall be responsible for finish grading
after the soil is compacted, as well as placement of topsoil and reseeding all areas disturbed by the
construction.
2.0 Septic Tank:
2.1 The existing septic tank must be properly abandoned by thoroughly pumping, removing the
top and backfilling with soil.
2.2 The new 1250 -gallon, 2 compartment septic tank shall be Municipally approved and shall be
set level on undisturbed soil. Each compartment shall be equipped with a watertight manhole cover and
a 4" cleanout. If the tank is buried less than 4 feet, it shall be insulated with 2 inches of approved burial
type, rigid insulation.
2.3 All pipe connections to the tank shall be equipped with waterproof mechanical couplings.
The waste line from the residence to the septic tank shall have a minimum slope of 1/4'" per foot, and
the waste line between the tank and the soil absorption system shall have a minimum slope of 1/8" per
foot. A cleanout shall be installed 1 - 4 feet from the building foundation, and a double cleanout shall be
installed within 5 feet downstream of the septic tank. The discharge line from the septic tank shall tee
into the perforated distribution pipe in the absorption trench at a point no more than 50 feet from either
end.
3.0 Soil absorption system:
3.1 The soil absorption system shall be constructed by excavating a 54 -foot long trench to a
depth of 11 feet below ground level in the vicinity of the test hole.. The long axis of the excavation shall
parallel an existing contour
3.2 The bottom of the excavation shall be level. Any compacted or smeared surfaces shall be
raked to allow proper infiltration.
3.3 A total of 7.5 feet of approved sewer gravel shall be placed in the bottom of the excavation
with the perforated distribution pipes laid level such that the pipe inverts are no less than 7.0 feet above
the bottom of the sewer gravel. Sewer gravel shall be 0.5" - 2.5" screened gravel, with less than 3%
passing the #200 sieve.
3.4 Monitor tubes and cleanout pipes shall be of 4" diameter and installed in the locations shown
on the design drawings. The portion of the monitor tube extending through the sewer gravel shall be
perforated.
3.5 Approved filter fabric shall be placed over the entire top surface of the sewer gravel. A
minimum of 2 feet of soil cover is to be placed over the filter fabric. If the soil cover thickness is less
than 3 feet, two inches of rigid, burial type insulation is to be placed over the entire top surface of the
gravel, in addition to the filter fabric.
3.6 The top surface of the cover material shall be raised a minimum of 6 inches higher than the
surrounding terrain to allow for subsequent settlement, and shall be graded to smooth contours. Fill
slopes shall be no steeper than 3:1.
3.7 Unless specifically agreed otherwise the homeowner shall be responsible for arranging to
have the site finish graded after the backfill material has stabilized, and for placement of adequate
topsoil and seed to promote rapid revegetation of all areas disturbed by the construction.
4.0 Inspections:
4.1 A minimum of 4 engineering inspections will be required during the course of the project:
(1) initial stakeout with the contractor to establish the location of the system and to discuss the plans,
specifications and construction procedures, (2) after the native material has been excavated to expose the
infiltrative surface to ensure that it is level and at the right elevation, and conforms with the soil test
information, (3) alter the sewer gravel is in place and the distribution pipes have been laid and connected
up to the septic tank, but prior to placement of insulation or filter fabric, and (4) after rough backfill and
grading is complete. The septic tank requires one inspection after it is set level and the piping
connected, but prior to backfill. This inspection may be incorporated with any of the above inspections.
4.2 The installer shall coordinate the timing of the inspections with the engineer sufficiently far
in advance to ensure the availability of the engineer.
FLATTOP TECHNICAL SERVICES
CIVIL 6 ENVIRONMENTAL ENGINEERING • ENERGY CONSERVATION & ANALYSIS
TED MOORE. P.E. 14530 ECHO CANYON ROAD
PHJFAX:(907)345.1355 ANCHORAGE, AK 99516
E -Mail: tgmoore@gcl.net March 16, 2006
Bill Reith, P.E.
ADEC Wastewater Program
555 Cordova Street
Anchorage, AK 99501
RE: Separation distance waiver between presumed Class "C" well on L2, DeArmoun S/D and proposed
private septic system upgrade on Ll, DeArmoun S/D
Dear Mr. Reith:
By means of this letter I am requesting issuance of a waiver allowing a proposed private septic
system upgrade to be constructed on Lot 1 of DeArmoun S/D at a distance as close as 135 feet from the
closer of two presumed Class "C" wells on Lot 2 of DeArmoun S/D. The actual status of these wells is
unknown; however physical inspection, as well as documents on file with the Municipality, indicate that
both wells comprise a Class "C" water system serving two separate dwelling units on Lot 2. My client,
the owner of Lot 1 of DeArmoun S/D, has no ownership or interest in the wells on Lot 2, except insofar
as he needs to upgrade the presently failing septic system on his own lot. Copies of a site plan, soils log,
design drawings and specifications for the proposed septic upgrade are enclosed, along with a well log
for Lot 2, as -built survey of Lot 2 and water sample test results for a nitrate sample collected from the
water system on Lot 2.
According to the enclosed well log for Lot 2, the well was drilled in July of 1978 and has a total
depth of 170 feet and a yield of 15 gpm. The log indicates predominantly clayey soils extending down
to 127 feet and also between 135 feet and 159 feet. The open-end casing of the well draws from an
aquifer located approximately 168 feet below ground surface, and the static water level is reported to be
at 45 feet below ground surface.
The enclosed as -built survey of Lot 2, dated August of 1983, shows the location of the two wells
on that lot, and indicates that at that time the active well was the more northerly of the two, which is
located more than 150 feet from the proposed septic system upgrade on Lot 1. However, as of March of
2006 the more southerly of the two wells also has a sanitary seal and conduit, indicating that it is (or
could be) part of the water system. This well is located approximately 130 feet from the present septic
system on Lot 1. While details of the exact underground configuration and construction are unknown,
septic standpipe locations are indicated on the as -built survey for Lot 2. From these one can determine
that the septic system serving this lot is located between the wells and the existing and proposed septic
system on Lot 1, and actually is much closer to both of the wells than the proposed septic upgrade for
which the waiver is being requested. This would lead one to the expectation that any indication of septic
contamination found in the water system would most likely be attributable to the on -lot septic system,
not one further away. As it happens, the water system's measured nitrate level of 0.12 mg/1 is almost
non-detectable, indicating an absence of septic contamination from any source.
The proposed septic upgrade on Lot 1 will be further from the well than the existing system but
still slightly closer to the well than the 150 -foot protective radius DEC specifies for Class "C" wells.
While it would theoretically be possible to construct the septic upgrade outside the 150 -foot radius, this
would entail considerable additional expense as well as destruction of valued man-made and vegetative
features.
As indicated on the soils log, the topography slopes downward from the wells to the septic
system on Lot 1. This means that were the system to fail in such a manner that effluent is discharged
onto the ground surface it would tend to flow away from rather than toward the well.
The following is an assessment of how waiver analysis points could be assigned in accordance
with DEC's 1985 "Separation Distance Waiver Guidelines for SCRO".
Category
Points
Distance to water table (assume at 168 -foot depth of source aquifer) 7.3
Soil sorption (predominantly clay and sand) 4.5
Soil type (predominantly clayey sand with pert rate>50 min/in.) 3.0
Water table gradient (<5% gradient away from water source) 2.9
Horizontal separation (135 feet) 4.4
Total 22.1
Based on this point assignment it appears that the requested waiver can safely be granted without
concern as to the potential for the proposed septic system being a potential source of contamination for
this water system. This conclusion is further augmented by the fact that after years of operation with
existing septic systems located significantly closer to the well the nitrate level is almost undetectable.
I am in the process of filing an application with the Municipality for a permit to allow
construction of the proposed upgrade. Please give me a call at 345-1344 if you have any questions on
this submittal.
Sincerely,
Ted Moore, P.E.
o.3vaba
" L) Jdl'a
49T
;►�
.................... kt
.THEODORE F. VOORE .*
CE -35009 • ' a•
4.4LL+:,� • ... R EI,P
a� !•v..r. v.;wk
Jul 26 2001 14:20 P.02
STATE LALUM Frank Murkowald, Governor
555 CORDOVA
DEPT. OF ENVIRONMENTAL CONSERVATION ANCHORAGE, AK 99501
Phone: (907)269-7519
DIVISION OF WATER Fax: (907) 269-3487
WASTEWATER DISCHARGE PROGRAM httpJ/www state.alcus/ded
April 11, 2006
Ted Moore, P.E.
Flattop Technical Services
14530 Echo Canyon Road
Anchorage, Alaska 99516
Re: DeArmoun Subdivision, Lot 1 & 2 -Separation Distance Waivers between a Class C
Source Well and an Onsite Wastewater Treatment System-ADEC Plan Tracking
Number 5496
Dear Mr. Moore:
On March 17, 2006 we received an engineered request to reduce the required separation
distances, between a Class C source well on Lot 2, and a planned replacement onlot wastewater
treatment system on Lot 1, DeArmoun Subdivision.
The new wastewater treatment system consists of a new two compartment 1,250 gallon septic
tank and a deep trench type soil absorption system with a 7 foot effective depth, a length of 54
feet and piping to serve the existing 4 bedroom home.
Based upon the engineer's recommendation, soil information, recent drinking water sample
results, and proper decommissioning of the exiting septic system, the following waivers are
approved.
The separation distance from the Class C source well on Lot 2 to the new septic tank on
Lot 1 of DeArmoun Subdivision is reduced from 150 feet to, 135 feet.
The separation distance from the Class C source well on Lot 2 to the new deep trench
type soil absorption system on Lot 1 of DeArmoua Subdivision is reduced from 150 feet
to 140 feet.
This approval does not imply the granting of additional authorizations nor obligate any state,
federal or local regulatory body to grant required authorizations.
Any person who disagrees with this decision may request an adjudicatory hearing in accordance
with 1 a AAC 15.195-18 AAC 15.340 or an informal review by the Division Director in
accordance with 18 AAC 15.185. Informal review requests must be delivered to the Division
Director, $55 Cordova Street, Anchorage, Alaska 99501, within 15 days of receiving the decision.
Adjudicatory hearings requests must be delivered to the Comm; sioner of the Department of
Fm ironmental Conservation, 410 Willoughby Avenue, Suite 303, P.O. Box 111800, Juneau,
Alaska 99801, within 30 days of the decision. If a hearing is not requested within 30 days, the
right to appeal is waived.
Jul 26 2001 14:20 P.03
Thank you for your cooperation. If you have any questions please do not hesitate to contact me at
269-7519.
Respectfully, a
William R. Rieth, P.E.
Environmental Engineer
cc: David Johnson, W W, w/o enc.
MUNICIPALITY OF ANCHORAGE 1
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street- Anchorage, Alaska 99501 Telephone 264.4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
NAME
Mrs Elva Sde-s
PHONE
77-G7GV1
1❑1�NEW
iF� UPGRADE
MAILING ADDRESS
/.b Anna o a blviye-
LEGAL DESCRIPTION Ir I /
L- o� e- A% -moo k, 14J G s7 ty k ,fea-
LOCATION 7�
D DP f�rwldv
NO. OF BEDROOMS
2
O Y
DISTANCE TO:
Well
Absorption aj ea
/ 7 7/ 4
Dwelling
6�
PER 1T NO.
2
W Fa-
Manufacturer ^ n �L�
CJ !G f-+
Mater TL -L- L
No. of compartments
to
Liq. ca .ty inAallons
Cl
IF HOMEMADE:
Inside length
Width
Liquid depth
6 Y
JVZ
DISTANCE TO:
Well
Dwelling
PERMIT NO.
_? f
Manufacturer
Material
Liquid capacity in gallons
OWell
W =
DISTANCE TO:
/�O
Fountlau n�
Nearest lo
PE PE f� JJO.
00
J a E
F- Z w
No. of lines
/
Length of tach line
7j
Total len of lines
v
Trench width
13160 inches
Distance between lines
s¢.•
p
Top of tile to finish grade
Material beneath til;
D inches
Total effective absorption area
300
W
Length
Width
Depth
PERMIT NO.
Q F-
d
Type of crib
Crib diameter
Crib depth
Total effective absorption area
W
H
DISTANCE TO:
Well
Building foundation
Nearest lot line
J
J
Class
Depth
Driller
Distance to lot line
PERMIT NO.
W
DISTANCE TO:
Building foundation
Sewer line
Septic tank
Absorption area (s)
OTHER
PIPE MATERIALS
pl/G
n
Z
SOIL TEST RATING
INSTALLER %
S �'�Cla ✓[�ivlt
L
REMARKS
P. OF A[,gs1��
�,�•�• ••N.22297E ;�� j
o IA
1 01.
•(jam..
APPROVED1l, -' NAL DATE✓ LEGAL 7� l
79-y7J�v
72-013 (Rev. 31781
PERMIT NO. C
MIJtJ I C"mF2FIL I TY QF F r-40�1ORFiGE
DEPARTMENT ,. HEALTH AND ENVIRONMENTAL .dOTECTION
825 'L' STREET, ANCHORAGE, AK. 99501
264-4720
0r4 — B I T E S E W E R P E R M I T
810021 ) q-kQc\Yczcu
APPLICANT ELVA SIDES
LOCATION DEARMOUN ROAD
LEGAL LOT K DEAP.MOUN
1338 ANNAPOLIS DRIVE
HOMESTEAD SUB
243-5302
LOT SIZE 50000 SQUARE FEET
TYPE OF SOIL ABSORPTION SYSTEM IS: TRENCH
MAXIMUM NUMBER OF BEDROOMS = /I no• SOIL RATING CSO FT/BP.)= 150
THE REQUIRED SIZE OF THE SOIL ABSORPTION! SYSTEM IS:
3D'
DEPTH= 1Q L_MrJ13_r 45 13FZnVEL- DEPTH= 5
THE LENGTH DIMENSION IS THE LENGTH CIN FEET) OF THE TRENCH OR DRAINFIELD.
THE DEPTH OF A TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE
GROUND AND THE BOTTOM OF THE EXCAVATION CIN FEET).
THERE IS NO SET WIDTH FOR TRENCHES.
THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE
AND THE BOTTOM OF THE EXCAVATION CIN FEET).
RE IJ I FZEO 'SEPTI C TRrJK 5 I ZE= 14Eif� GFiLL_OrJS
PERMIT APPLICANT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DUPING THE
INSTALLATION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY AND THE
NUMBER. OF RESIDENCES THAT THE WELL WILL SERVE.
--- TWC <2:> I RISPECT I OFJS FIRE FZMiMU I REO ---
BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS
DEPARTMENT WILL BE SUBJECT TO PROSECUTION.
MINIMUM DISTANCE BETWEEN A WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS
100 FEET FOR A PRIVATE WELL OR 150 TO 200 FEET FROM A PUBLIC WELL DEPENDING
UPON THE TYPE OF PUBLIC WELL.
MINIMUM DISTANCE FROM A PRIVATE WELL TO A PRIVATE SEWER. LINE IS 25 FEET AND
TO A COMMUNITY SEWER LINE IS 75 FEET.
OTHER. REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE
AVAILABLE TO INSURE PROPER INSTALLATION.
PERM I T EXP I RE'S DECEMBER ZEAL, 1S=+S1
I CERTIFY THAT
1: I AM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET
FORTH BY THE MUNICIPALITY OF ANCHORAGE.
2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES.
3: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE
RESIDENCE IS REMODELED TO INCLUDE MORE THAN 3 BEDROOMS.
Sq IED
APPLIC9NT ELVA SIDES
ISSUED BY
V4. 0
SOILS LOG
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION ❑ PERCOLATION
TEST
825 L. Street, Anchors9a, Alaska 99501 4644720
SOILS LOG - PERCOLATION TEST p
PERFORMED FOR: rlr4 �/GL.. G tole—s _DATE PERFORMED: 2 146 A
LEGAL
1 -
2-
3-
4-
5.
•3•4•5.
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
v0/ L
73 rO LL^l
SP
'?oocL C r&j-k0Cn
( rY-d �
SSD LR- M Q
cu.LcP c.o�+��nneg
.`��. OF A
,,,gyp.,•
h.
*:4
SITH
2225-E
f 1. 1 NE 25, 1971
•l\ s/01
COMMENTS /I" :!�K%
/20
PERFORMED BY:
72-008 (6/79)
St.
SLOPE
WASGROUND WATER
ENCOUNTERED? 'D
IF YES, AT WHAT
DEPTH?
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
.1;0
gtRCOLATION RATE (minutes/inch)
TEST RUN RETWEFV � FT AND T— FT n
CERTIFIED
DA
LL
r,
MUNICIPALITY OF ANCHORAGE
DIVISION OF ENVIRONMENTAL HEALTH
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
APPLICATION FOR HEALTH AUTHORITY APPROVAL CERTIFICATE
1. General Information
Application Date 816 fi-AV
(a) Legal Description (include lot, block, subdivision, section, township, range)
/_1 1 . i2:r 1 7TJL 525 TI2Al r3tJ
Location (address or di
3 ys-S6 9
(b) Applicants
Applicants Address,
(c) Applicant is (check one) Lending Institution ; Owner/builder
Buyer Q ; Other [:::I (explain);
(d) Lending Institution &0/ i Telephone
Address
(e) Real Estate Co. 6 Agent A/LIQ
Address
Telephone
(f) Mail the HAA to the following address:
,4F,el c 1. A.4 6eX&OAl
efool .neat
i4 i /,nia,a3,g i4/ �/9S/lam
2. Type of Residence
Single -Family [21 Multi -Family Other (describe)
Number of Bedrooms oc
3. Water Supply -
Individual Well Community Public
Note: If community well system, must have written confirmation from the State
Department of Environmental Conservation attesting to the legality and status.
4. Sewage Disposal �••-;�?-
Onsite Public Community ',.Holding Tank
Note: If community well system, must,have 'written confirmation from the State
Department of Environmental Conservation attesting to the legality and status.
[Page 1 of 21
5
Engineering Firm Providing Inspections, Tests, File Search, Data and Information
As certified by my seal affixed hereto and as of the validation date shown below, I
verify that my investigation of this Health Authority Approval shows that the on-site
water supply and/or wastewater disposal system is safe, functional and adequate for
the number of bedrooms and type of structure indicated herein. I further verify that,
based on the information obtained from the Municipality of Anchorage files and from my
investigation and inspection, the on-site water supply and/or wastewater disposal
system is in compliance with all Municipal and State codes, ordinances, and regula-
tions in effect on the date of this inspection.
Name of Firm AA t,) fte Yh z Telephone :7114 4 7 /l
Address 2 J 1,1 1 In "ah
Date
(ENGINEER SEAI1�
C...l....Z7
Q• NEI, NAVT`r`_ ..
v1:5 CE -4:o y
6. DHEP Approval �' '
Approved for �— bedrooms By ate
Approved Disapproved Conditional
Terms of Co ditional Approval
CAUTION
THE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
(DHEP) ISSUES HEALTH AUTHORITY APPROVAL CERTIFICATES BASED SOLELY UPON THE REPRESENT-
ATIONS GIVEN IN PARAGRAPH 5 ABOVE BY AN INDEPENDENT PROFESSION\L ENGINEER REGISTERED
IN THE STATE OF ALASKA. THE DHEP DOES THIS AS A COURTESY TO PURCHASERS OF HOMES AND
THEIR LENDING INSTITUTIONS IN ORDER TO SATISFY CERTAIN FEDERAL AND STATE REQUIRE-
MENTS. EMPLOYEES OF DHEP DO NOT CONDUCT INSPECTIONS OR ANALYZE DATA BEFORE A
CERTIFICATE IS ISSUED. THE MUNICIPALITY OF ANCHORAGE IS NOr RESPONSIBLE FOR ERRORS
OR OMISSIONS IN THE PROFESSIONAL ENGINEER'S WORK.
RR4/ej/D18
[Page 2 of 21
(DILE? .-SEAL)
7-19-84
( ,
JNICIPALITY OF ANCHORAGE
DEPT. OF HEALTH &
ENVIRONMENTAL PROTECTION
MUNICIPALITY OF ANCHORAGE
(MOA)
HEALTH AUTHORITY APPROVAL (HAA) AUG 14 10,84
CHECKLIST - FEBRUARY
1984 R E E�C9EI V E D
Legal Description:
A. WELL DATA
Well Classification '42 ',o>G If A, B, or
C, D.E.C. Approved(Y/N)
Well Log Present (Y/N) /V6 Date Completed ii/lleAm ),4/ Yield?( gnrt
Total Depth >,s -p Cased to IIA/PA/A)011
Depth of Grouting
Static Water Level riA/t'/IJPJV Pump Set At
///VKn/�/✓/i
Casing Height Above Ground 1411"
Sanitary Seal on Casing (Y )W'
Electrical Wiring in Conduit (Y/N)
Depression Around wellhead (Y
Separation Distances from Well:
To septic/Holding Tank on Lot / z° ry
On Adjoining Lots /nom
To Nearest Edge of Absorption Field or. Lot/?� ; On Adjoining Lots /.no"
To Nearest Public Sewer Line
To Nearest Public Sewer
Cleancut/Manhole4�/1 To Nearest Sewer Service Line on Lot 3r
Water Sample Collected By r>
Date Pa
Water Sample Vest Results S
Comments
B. SEPTIC/HOLDING TANK DATA
Date Installed 2-a�/-&D Size ZZSQ 42,4/ No. of Cc partments
Standpipes (Y/N) YGS Air -tight Cape (Y/N) yef�� Foundation Cleanout (Y/N) VrS
Depression over Tank (y/N) Date Last Pumped 5:r -Pr -94/
PLmping/Maintenarce Contract on File (Y ) for ///4
Holding Tank High -Water Alarm (Y/N) 1/ Temporary Holding Tank Permit (YM) 'si14,-
Separation Distances from Septic/Holding Tank:
To Water -Supply Well _/n7 To Building Foundation
To Property Line /p 'f To Disposal Field /7,
To Water Main/Service Line To Stream, Pond, Lake, or Major Drainage
Course
Comments
[Page 1 of 21
2-15-84
C. ABSORPTION FIELD RATA
Soils Rating in Absorption Strata /Ti) 84474 Type of System Design
Date Installed _ .') -.0 0 -Rn Length of Field ,::�/
Width of Field ,���� Depth of Field //7'
Gravel Bed Thickness ,5-�
Square Feet of Absorption Area &o 5 Standpipes Present (Y/N) YP.S
Depression over Field _(_YM) IVO 77 Late of Last Adequacy Test Y -f7- 9'41
Results of Last Adequacy ML st Oz
Separation Distance from Absorption Field:
To Water -Supply X11 / To Property Line 1,P) '
To,Building Foundation StF ` To Existing or Abandoned System cn
Lot!✓ei�� �� o 7 -e -n On Adjoining Lots V/)
To Water Main/Service Line /S' " To Cutbank(if present) ///!J
To Stream/Pond/Lake/cr Major Drainage Course ///A
To Driveway, Parking Area,
or vehicle Storage Area
Ccsment8 (JN s/!�� ro�H X �x To �cst� iw M%un i tars.
D. LIFT STATICN
Date Installed Dimensions
Siwe in Gallons Manhole/Access (YM)
"Pimp on" Level at "Pump Off" Level at
High Pieter Alarm Level at Vent (YIN)
Tested for Pmping Cycles during Adequacy lost.. Meets MDA
Electrical Codes(Y,/N)
Camnents
** Check Permitted Bedroom Rating Against HAA Request **
I certify that I have checked, verified, or conformed to all MOA
on the date ofis ins cti
Signa Date s//o
Company MO -W + ke rH a MOA No. STB4d � 9
RB1/d5/s .
(Page 2 of 21
ir. effect
Q': 9
ks.: 4gTN a
..... ;2S y
CE. A36? y`®
tf•.. y
2-15-64
.AG�4liyc/ T�.5T _
/c2SD fAG
7oraG f1iSe L"eb.,V
/ PD'
7Z'
/S9'
ass ' ��vu Tsr
6 -s -eel
/wr 5�4 c C)(C4rLS CAf'AC IiV
OU& 7'117G fo
E WE
/d -'/o
/o
/D: y0
ii= 00
//:Zo
//: Z/o
/2:00
/2.' W
/Z:,e/o
/: 60
�= .O �jDi'7 �GiN lCt'GG y9r,'bJt2Tiad
o ,f.:.
a. o yf4ll
r� n
NHAWTHORNE-ENGINEERING .DArc : g-g-av
•?OT'AWCTIC BOULEVARD
NHAWTHORNE - ENGINEE( tIG &w*E-zes
7127 Old Seward Highw.,y AweNeRAec.ALASKA 99503
Anc1L. AK 99502 344-4711. 9B7 3;1;t-4698
jVezLTieA)
Alez-c e -Sive 6pr7elvos to yAeilvt9
.o-leoei- --Ron ' l
6 �ec� X L1 uJlde ehCi-JUAT�orO
G� SC�7ioU p< cu,4u4SP-r P1Pe 611W,'P Mbb &RSiAv9 AVAP
SVe'o y /oA.07 llJ/5l11-W "OIV f/CLs Ueli9 kZ(Veea Cr(LPeA
PiPG ANG eMeW exT��oivG FRor7 6ono� of excAv�47ioW
, o y, eo vo levee,
4 Z' / x wooDeN G19P cv� A9e1V6oAeee '11P eooe40S
evriRe exGAdA7 io,o tu/ SPRAv ,COAIJ /N&ee47'iovv e reNo,,ij�
/=/QD�'1 9RddNtl �EUEG �o �O� oA' Igoove�v CAp. !�q.PAy
IeI917 /S CO�tI>l.rluDos FiQO/'J 5/OCS/ 06 �Cgv,gT�oW
TO T"D� of lUD6'DC'iJ GO�Je Q 6vh jGii �oFF�7-7 dee, y
/O�i'i°Oe.urs ,Qunror� ,c�or7 cov>'AGr�.v�c. �.osl�uG.
CHEMICAL & GEOLOGICAL LABORATORIES OF ALASKA, INC.
TELEPHONE(907)562-2343 ANCHORAGE INDUSTRIAL CENTER
5633 B Street
Drinking Water Analysis Report for Total Coliform Bacteria
TO BEC MPL�TED BY WATER SUPPLIER « TO BE COMPLETED BY LABORATORY
�ic cru ewef�i CAovRC [u✓
Pktier5'rDe' (•) Sea h on back
WATER SYSTEM:
I.D. N.
?yd -4/7/1
Water system Nemo I Phony No.
Mame Address
&1 i , So" 99_ Co
cl Seer Zip Code
SAMPLE DATE: p ® 6 4-
Mo.
SAMPLE TYPE:
❑ Routine
❑ Check Sample (for routine sample t ❑Treated Water
with tab ref. no. ❑ Untreated Water
❑ Special Purpose
SAMPLE
NO. LOCATION
3
4 I
S I I
READ INSTRUCTIONS
BEFORE
COLLECTING SAMPLE
Cos
llected
Collected
B
lCA J
Analysis shows this Water SAMPLE to be:
Satisfactory ie-Cr;ID
❑ Unsatisfactory SAKF'r-c
❑ Sample too long in transit; sample should
not be over 30 hours old at examination to
Indicate reliable results. Please send new
sample via special delivery mail.
Date Received 01A A T
Time Received
Analytical Method:
❑ Fermentation Tube
Membrane Filter
/S/ov
Lab Ref. No. Result' Analyst
l I m
I I m
U m
U m
.n, a co . loo w &"01 h`w. rorm.r
.euzass BACTERIOLOGICAL WATER ANALYSIS RECORD
an. 1983
Membrane Filter. Direct Count
Collfonnit00ml
Verification: LTB a BGB
Final Membrana Filter Results _7'c' CoillomV100mI
Reported By. Date
\ S f ,!`
Time: a.m.
t pm.
TNTC= Too Numerous To Count
,...
DATE RECEIVED
INSPECTION APPOINTMENTS
—7'Xe
TIME
TIME
/D . —;'�b /� �� /f *1 Vuw`^
TIME
i
e Irv\
DATE
DATE p
$1
DA E
-l1—
"4
INSPECTOR
INSPECIOR
INSPECTO
fV
MUNICIPALITY OF ANCHORAGE UNICIPALITY OF ANCHORAGE
DEPT. GP FI'_!TrI &
-\ DEPARTMENT OF HEALTH G ENVIRONMENTAL PROTECTIORT/IRONMENTAL I, :, TICTION
1 825 L Street • Anchorage, Alaska 99507
ENVIRONMENTAL SANITATION DIVISION FEB 101981
Telephone 2644720 R EE cc F
REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER F kkkv FFD
DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing.
1. PROPERTYOWNE
ESM % y
PHONE
a/ 4" c� a
YEAR ON-SITE SYSTEM WAS INSTALLED.
MAILING ADDRESS
/330 ",,
PROPERTY RESIDENT (If different from above) r—�
PHONE
2. BUYS
�.... -�9C& cP �va
PHONE
�fi�-3/y3
MAILING AD ESS
?DocJ 3.2= -,"�Lf<
3. LENDING INSTITIJITION �
PHONE p
CEJ J :! F.✓/ti�� N
i O D�
MAILING ADDRESS f, e
4. REALTOR/AGENT
T.—,PHONE
MAILING ADDRE S
D
1S1L4t
5. LEGAL DESCRIPTION f
.
T
STREET LOCATION
6. TYPE OF RESIDENCE
NUMBER OF,BEDROOMS
SINGLE FAMILY
❑ One ❑ Four ❑ Other
' Two ❑ Five
❑ MULTIPLE FAMILY
❑ Three ❑ Six
7. WATER SUPPLY
INDIVIDUAL'
• ATTACH WELL LOG. A well log is required for all wells drilled
0 COMMUNITY
since June 1975. For wells drilled prior to that date, give well
❑ PUBLIC UTILITY
depth (attach log if available.)
8. SEWAGE DISPOSAL SYSTEM
INDIVIDUAL/ON-SITE"
YEAR ON-SITE SYSTEM WAS INSTALLED.
❑ PUBLIC UTILITY
r
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED
72-010 (Rev. 6/79) , •� I ,/t1n , � /,� -
rt
—.' THIS SIDE FOR OFFICIAL USE ONLY
1. TYPE OF RESIDENCE
❑ SINGLEFAMILY
❑ MULTIPLE FAMILY
NUMBER OF BEDROOMS
❑ ONE ❑ THREE ❑ FIVE ❑ OTHER
❑ TWO ❑ FOUR ❑ SIX
2. WATER SUPPLY
❑ INDIVIDUAL
❑ COMMUNITY
❑ PUBLICUTILITY
Connection Verified
PERMIT NUMBER
DEPTH OF WELL
DATE DRILLED ...
LOG RECEIVED
3. SEWAGE DISPOSAL SYSTEM
❑INDIVIDUAL/ON-SITE _ _
❑PUBLIC UTILITY
Connection Verified
PERMIT NUMBER
DATEINSTALLED
INSTALLER
❑Septic Tank or ❑ Holding Tank
Size: If Tank is homemade
give dimensions:
SOILS RATING
TYPE OF TANK,
MANUFACTURER
TOTAL ABSORPTION AREA
MATERIAL
4. DISTANCES
WELL TO:
Septic/Holding Tank
Absorption Area
Sewer Line
Nearest Lot Line
Absorption Area to nearest Lot Line
5. COMMENTS
I_A_r11; bJ
�PPROVEDFOR_ BEDROOMS
❑ CONDITIONAL APPROVAL (letter must accompany certificate)
❑ DISAPPROVED
DATE ^ �\ �Ne,.
BY -
720/0 (Raw. 6/79)
Municipality
®f
Anchorage
825"L"STREET` �lu�+s. a-aco-SJ
ANCHORAGE, ALASKA 99501 PQ1
(907) 264-4111 j� J
GEORGE M. SULLIVAN,
MAYOR
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
February 17, 1981 1)%
V"
Maxweldon/
Alva Sides
1330
1330 Annapolis
Anchorage, Alaska 99504
Subject: Lot 1 De Armoun Homestead Subdivision
Approval for your individual sewer and water facilities
cannot be granted until the following items have been
completed:
(1) The water analysis report needs to be delivered to
this office from the Chem Lab: 5633 B Street, for
our review.
(2) A soils test needs to be performed on the property \ \
and a new on-site sewer system needs to be installed.
Prior to any construction, a permit needs to be
obtained from this office for new -on-site sewer
Sys em.
3 �C¢l/1 a C trP
I ere are any further questions, ple.se call this
office at 264-4720. V)
Sincerely,
Robert C. Pratt, R.S.
Associate Specialist
RCP/ljw
cc: First National Bank of Anchorage
Post Office Box 4-2090 99509
Jerry Dewhurst
% Dynamic Realty, Inc.
501 West Northern Lights Boulevard
99503
GREATER ANCHMM AREA BOROUGH
Department of Environmental Quality
35bO Tudor Road, Anchorage, Alaska 99507 279-9686
' Date Received
Time of Inspection /Q : 00
Date of Inspections%
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER & WATER FACILITIES
FOR
1. Aoproval Requested By:
Address.
Phones
- 2.
Prooerty Owner:
QIA-016 w
Phones3yc/-A rw
3.
Legal Description:
9-4-�i iLkAjL
00fu.x- ��--
>r
4. Locations
5. Type of F
Number of Bedrooms:
6. Well Data:
A. Type
C. Constructi on zs
B. Depth / Zp
D. Bacterial Analysis'
7. Sewage Disoosai Systems
A. Installed (a(0/ 8. Installer 0\wo..
C. Septic Tanki 1. Size%C:500 2. Manufacturer
D. Seepage Pit' 1. $izeeil 2. Material tg3,
E. Disposal Field: Total Length of Lines
B. Distances:
A. Well Tot Septic Tank K ci-� Absorption Area 1 0 0 Sewer Lines
e)()r , Nearest Lot Line 4 ! , Other Contamination
B. Foundation to Septic Tank 3C\ /
a/ "1. Absorption Area 5 C. Absorption Area to Nearest Lot Line of '
k,
� `k+quest for Approval �' ,Wividual Sewer 6 Water Faoiltr'i�s
Page Two x
• 9. Commentas
Approval Valid for One Year From Date Signed
Greater Anchorage Area Borough, Department of Environmental Quality
DTAGRAM OF SYSTEM
T certifv that the information contained in this request for approval to be a true
and accurate representation of the subiect sewer and water facilities located sto