HomeMy WebLinkAboutSUETAWN ESTATE LT 2Suetawn Estates Lot 2 #051 - 501 - 18 Municipality of Anchorage' George P. Wuerch, Mayor Building Safety Division P O Box 1966.50 * 4700 S Bragaw Street Anchorage, Alaska 99519 6650 * (907) 343-8301 http//wwx~ ct anchorage al{ us ~epartment o~ Public Works 6/7/2001 c/o KND Engmeenng 20441 Ptarmigan Blvd Eagle Rtver AK 99577 SubJect Dear On-S~te Water and/or Wastewater Permit Permit Number. SW00020 Parcel ID #051-501-18 An On-S~te Water/Wastewater Permit, number SW00020, ~ssued by tins office for a single-family system, will expire on June 29, 2001. Th~s permit was valid for 365 calendar days If th~s was a well permit and the well has been drilled, a well log must be sent to th~s office for documentation of the installation and to close the permit If th~s permit was for a wastewater disposal system, an ong~nal as-built inspection report must be sent to this office for rewew, approval and documentatmn This as-built inspection report must be signed by the hcensed Professmnal Engineer who ~nspected the installation of the system As-bmlt inspection reports are reqmred to be submitted w~th~n 30 days of the completion of the system If no system was installed under tlus permit, and you are still planmng to ~nstall a well or wastewater dmposal system, a new permit must be obtmned from this office A new permit may be issued free of charge for a second year If the apphcatmn for the renewal is received on or before the date of expiration of the onginal permit When applying for a new permit, the fees are $320 00 for a wastewater permit and $120 00 for a well permit If you have any questions, please call th~s office at 343-7904 Manager On-S~te Water and W. astewater Program enc Copy ofpenmt MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-S~te Services Program 825 L Street, Room 502 P 0 Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Imtlal Date Issued Jun 29, 2000 Expiration Date Jun 29, 2001 Permit Number. SW000202 Legal Descnpbon SUETAWN ESTATE LT 2 Design Engineer 0070 KND Eng~neenng Owner Name c/o KND Engmeenng Owner Address 20441 Ptarmigan BIvd Eagle R~ver, AK 99577- Parcel ID 051-501-18 S~te Address 023226 RICKY WAY Lot S~ze 60984 SQ FT Total Bedrooms 3 Permit Bedrooms 3 Th~s permit ~s for the construction of [] Disposal F~eld [] SeptlcTank [] Hold~ng Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with I The attached approved design 2 AIl requirements specified In Anchorage Mumc~pal Code Chapters 15 55 and 15 65 and the State of Alaska Wastewater D~sposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ) 3 The engineer must not~fy DHHS at least 2 hours prior to each ~nspecbon Prowde nobflcat~on by calhng (907) 343-4744 ( 24 hours ) ( Not required for a Water Supply Permit only ) 4 From October 15 to April 15, a subsurface so~l absorption system under construction dunng freezing weather must be e~ther A Open and closed on the same day B Covered, sealed, and heated to prevent freezing Rece,ved By ("~0~..h~.- ,.~,..0~ / ~/ ~ND ENGINEERING 20~1 PTAPdV~GAN BLVD EAGLE RIVER, AK 99577-8736 (907)696-6111/FAX (907)696-8111 June 15, 2000 Municipality of Anchorage Dept. of Health & Human Services On-Site Services Section P. O. Box 196650 Anchorage, Alaska 99519-6650 Subject: New sewer & well permit - Sue Tawn Estates Lot 2 Add. No.1 Gentlemen: The owner has requested we proceed forward to obtain a well and septic permit on the subject lot On May 25, 2000 we dug one testhole for the proposed system The results of the test is attached The general slope of this lot is from west to east at a grade of approximately 5-10% for the western one-third of the property. From there the slope continues in excess of 25% to Little Peter's Creek on the eastern portion of the property. We have designed our system utlhzmg the testhole we excavated for the 3-bedroom house, which is proposed for this lot. The lot will be served by an individual well. We propose to install a 2' wide deep trench Water was not encountered during the excavation or monitoring There are no public or private wells within 200' of our proposed system location except as noted There is no surface water within 100' of the proposed system and there are no known curtain drams within 50'. We do not expect there to be any adverse effect on adjacent lots by the development of this system. If you have any questions, please contact me at 696-6111/FAX 696-8111. Respectfully submitted, ]l(I~) Engineering attachments On-Site Well and Sewer Application Wastewater Absorption System Details/Site Plan Soils Log/Percolation Test ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 (907) 696-6111/FAX (907) 696-8111 September 13, 2000 Municipality of Anchorage Dept of Health & Human Services On-S~te Services Section P O Box 196650 Anchorage, Alaska 99519-6650 Subject: Request modification of design for new sewer/well permit - Sue Tawn Lot 2 Permit Number SW000202 Gentlemen. On June 29~', 2000 you issued a permit for a new well and sephc Subsequently the owner has decide to change the previously proposed 3-bedroom house to a 5- bedroom house, which necessitates the design to be changed to a 1500 gallon septic tank and to a trench length of 52 feet All other items on the previous request will remain ~the same Please find the attached plan-destgn modifications for your approval. If you have any questions, please contact me at 696-6111/FAX 696-8111 Respectfully submitted, ~}~D Englneenng Kenneth M Duffus, P E Attachments Wastewater Absorption System Details/Site Plan K B WASTEWATER 1500 S,T, TH-O0 DISPDSAL SYSTEM SUE TAWN S/D, LOT 2 5-1OF. r-., FCB DETAILS ~> 7 25+Xr 5-10Xr.., c~[c,~o KMD ,m,~> NW1160 f f f f Scc~te 1'= 80' PAGE 8 DF 8 ]~) ENGINEERING 2044! PTARMIGAN BLVD. EAGLE RIVER, AK 99577-B736 000,30 WELL & WASTE~/ATER DISPOSAL SYSTEM DETAILS/SITE PLAN SUE TAWN S/D, LOT K I D ~ ,~ ,,/ ---ELDERDrive " 3 DESIGN DETAILS 5 BDRM X 150 GPO = 750 GPD 750 GPD/IE GPO PER SO FT (167 MIN/IN)= 6E5 SO MIN 3' COVER IF REQUIRED PREPARED FOR DORRIS & AL ROSS PO DBX 671508 CHUGIAKo AK 99567 FIELD BOOKS cou~J~O BOUND~Y' MLH ORA~ sY~,.m MLH ~D KMD A~ILT' MUH DA~ D~ r~ ~,o NW1160 ~"~ 00030 DWG ~"~ 00030 3 Scare 1'= 100' PAGE 1 DF 2 ~) ENGINEERING 2044! PTARMIGAN BLVD. EAGLE RIVER, Al( 99577-8736 FT 625/(6'(D) X 2'(W)) (60' GRAVEL) = 520 FT TRENCH ND PU~ILIC W£U.$ WITHIN ~00' ar Use 1 'trench 52°(L) x ~'(W) x 6'(D) ND SEPTZC SYST~NS VITHZN EO0 ~ To'at depth OF g~ve[ below d,s~mbu~on p~pe ~s 60' 1 USE 1500 GALLON SEPTIC TANK INSULATE TANK IF <4' COVER INSULATE TRENCHES VITH ~' HD BURIAL FDAN 3 CONTRACTOR ~ILL ENSURE NAXINUN EX SLOPE INTO SEPTIC TANK ADDITIONAL FILL WILL BE ADDED OVER SYSTEM TD ACHIEVE ~%OFA EAGLE RIVER, AK 99577-8736 Performed for SOILS PERCOLATION TEST Dorris & A1 Ross Date Performed 5/25/00 Project Sue Tawn Lot 2 TEST HOLE # 00-01 Depth (Feet) ORG - black rootmat SEE ATTACHED SITE PLAN J FOR HOLE LOCATION I GP/GW - cobbies to 2'-3' Loose bm/gray Was Ground water encountered? NO What depth? NA Depth to water after momtormg? NONE Date? 6/2/00 Reachng Date Gross Net Depth to Net T~me T~me Water Drop 1 5/25/00 1 00 9" 2 110 10mm 24/16" 611/16" 3 * 1 11 9" 4 121 10mm 27/16" 69/16" 5 * 1 22 9" 6 132 10mm 214/16" 62/16" 7 * 1 33 9" 8 1 43 10 mm 3" 6 ' 9 * 144 9' 10 1 54 10 mm 3" 6 ' 11 * 1 55 9" 12 2 05 10 mm 3" 6 ' · Water Added Percolation Rate 1 67 (mm/m) Perc Hole Diameter 6" J Test Run Between 2 feet and 3 feet HOLE PRESOAKED PRIOR TO TEST B 0 H. - 21' I, Kenneth M Duffus, certify that flus test was performed m accordance w~th all State and Mumcapal gtudehnes m effect on flus date GRE,' ',R ANCHORAGE AREA B0, ' _GH Department of Environmental QualiW 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME SEPTIC TANK: DISTANCE FROM WELL INSIDE LENGTH MAILING ADDRESS /~O /-/~/~'//n1 ~/, LEGAL DESCRIPTION ~// ~ MANUFACTURER ////)gel ~. T~// MATERIAl INSIDE WIDTH LIQUID DEPTH PHONE NUMBER OF COMPARTMENTS .LIQUID CAPACITY /~ GALLONS. SEEPAGE PIT: NUMBER OF PITS DIAMETER OR WIDTH LENGTH DEPTH LINING MATERIAL BUILDING FOUNDATION__ ADDITIONAL ABSORPTION CRIB SIZE: DIAMETER NEAREST LOT LINE DEPTH DISTANCE FROM: WELL ~- TOTAL EFFECTIVE ~ ABSORPTION AREA (WALL AREA . FT. WELL: TYPE BUILDING FOUNDATION -- CESSPOOL APPROVED NEAREST SEWER LINE CONSTRUCTION NEAREST LOT LINE OTHER SOURCES DISAPPROVED OEPTH DISTANCE FROM: SEPTIC SEEPAGE TANK SYSTEM REMARKS DISTANCES: INSTALLED BY: PIPE MATERIAL: LOT SLOPE: REMARKS: DIAGRAM OF SYSTEM Form No. EQ-031 DATE GREATER ANCHORAGE AREA BOROUGH· DEPARTMENT OF ENVIRONMENTAL QUALITY 3330 "C" STREET ANCHORAGE~ ALASKA 99503 TELEPHONE 274-4561 SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PEI~MIY PERMIT NO. INSTALLATION LOCATION LEGAL DESCRIPTION INSTALLATION Of: SEPTIC TANK f SEEPAGE Pit ~ TYPE AND SIZE OF FACILITY TO Be SERVED ~/~ FINANCED THROUGH ADDRESS SOIL TEST RESULTS ., OTHER NOTE: THIS PEI~MIT IS NOT VALID WITHOUT SOIL COMPlETiON DATE ANTICIPATED FINAL iNSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTmENt OF ENVIRONmENTAl QUALITY AU, ThORiTY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK size f~ TYPE ~ SEEPA'ge AREA SiZE ~ TYPE ~ ~/~. DRAIN FIELD FOUNDATION TO SEEPAGE Pit 7~ { DRA]~ FIELD SEPTIC TANK TO SEEPAGE Pit WALL SEEPAGE PIT ALSO CONSIDER AREA WELLS. seEPAGE PIT TO RIVER, LAKE, STREAM. CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRI~ CROS~]N~ GAP~F EXCAVATION 5 FEET INTO UNDISTURBED SOIL. ~JNCH D~AMETER CAST IRON SIPHON PIPES ON SEPTIC: TANK AND SEEPAGE Pit FITTED WITH Airtight REMOVABLE CAPS· CONFORM TO BOROUGH GULATiONS REGARDING iNSTALLATION. } CERTIFY THAT ] AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE A~EA ~OROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE DESCRI SY EM IS IN ACCORDANCE WITH SAID CODE. '~-" ~t31~-¥ REATER ANCHORAGE AREA BOROUGH OF ENVIRONMENTAl QUALITY JUL '~ ~ ~§~B DE.-'RTM'~ZNT3330 "C" Street ~ ~o~ou~rANCHORAGE ALASKA 99503 Performed For ~ _(~ (~ w Legal Description: Lot ~ __Block This Form Reports Soils Log_~ Soil Test Must Be Logged To 4' Case # Dated Performed 7- Subdivision Percolation Test Below Proposed Seepage System Depth Feet Soil Characteristics 3-- 4-- 5I 6~ 7-- ~9~ 10~ ll-- 12~ 13-- 114-- Was Ground Water Encountered?~$ If Yes, At What Depth? Reading Percolation Proposed Depth COM~ENTS: Net Time Date Gross Time Depth to H20 Rate Mi nute Installation: Seepagn ,Pit of Inlet ........................... Depth to Bottom of Net Dro Drain Field Pit Or Trench Test Performed BY__]_._~ ~---.--~~-T- ~-~ ...... Date Certified BY: Date: · )..":. 2 .' ' -2~ {.: . ~ ~ { ~.. ~ ' : ~ i : :/~ MUNICIPALITY OF ANCHORAGE DEPARTE~ENT OF HEALTH AND ENVIRONIVIENTAL PROTECTION DIVISION OF ENVIRONMENTAL HEALTH CERTIFICATE OF iNSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY 264-4720 Application Date GENERAl. INFORMATION (a) Legal Description (include lot, block, subdivision, section, township, range) Location (address or directions) (b) ApplicantName_2¢'-'"'~ ~¢';'-¢~" /.¢~,~-¢~,,,Telephone:Home z/?~--~°'~ Business .~72--/~F_¢ Applicant Address -.~",~' ,' '/~¢'~ //? ¢ d'~ ~- · ~' ~ .~',,'-/¢- ~',~' .C'd 2 (c) Applicant is (check one): Lending institution []; Owner/builder [~[; Buyer []; Other [] (explain); (d) Lending Institution /c_~_'~ ~._ ,,q/C, Address ~--:~ ~ ~.- ZF ,q-'~ ~ ~'~, ~-,- ..~ (e) Rea Estate Company and Agent Adoress (f) Telephone ' Mail the HAA to the following address: TYPE OF RESIDENCE SinCe-Family.~ Multi-Family [] Number of Bedrooms Other WATER SUPPLV Individual Well~]' Community [] Public [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 4 SEWAGE DISPOSAL Onsite'~' Public [] Community [] Holding Tank [] Note: if community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. Page 1 of 2 72-025 'ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION ,~,s certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms end type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm F-.AGLE RIVER FNGINFFRING g:~:RVIC_~ES Telephone EA6LE RIVER, At( 99577 Address . PTu. ~U,.v Date '~ ~c.//.~ ~-- Engineer's Seal Approved for-~-,~ ~- -be/d r o o m s..,,~,_b~_~}~,~_~.~* Approved ~/' Disapproved "~ -- Terms of Conditional Approval / Cahditional CAUTION The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or anaryze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 72-025 (11/84) MU~,II¢IPAgl~' OF ANCHORAGE DEPT. OF HEALTH & E~VIRoNMENTAL pROTECTiON RECEIVED MUNICIPALITY OF ANCHORAGE (MOA) HEALTH AUTHQRITY APPROVAL (HAA) CHECKLIST - FEBRUARY 1984 264-4720 Legal Description: A. WELL DATA Well Classification ,/¢:~ r-i ~/~, ~ I(A, B, C, D.E.C. Approved (Y/N) Well Log Present (Y/N) ~ Dat~ Completed ~/~-'/~ ~ Yield .~. Total Depth _~'o / Cased to ~'0 ~ Static Water Level 'f-/~,-.-,,~_~ .g,-/~.-,r,~,. Casing Height Above Ground 2`/ Electrical Wiring in Conduit (Y/N) Y Separation Distances from Well: Depth of Grouting Pump S~t At '~° ~-~'~-~ Sanitary Seal on Casing (Y/N) Depression Around Wellhead (Y/N) To Septic/Holding Tank on Lot ~:~ 7 ~ ; On Adjoining Lots To Nearest Edge of Absorption Field on Lot /c~ ~'~-~"; On Adjoining Lo'~S To Nearest Public Sewer Line '"~/~"~"~'~- To Nearest Public Sewer Cleanout/Manhole /Z.]~., ~ To Nearest Sewer Service Line on Lot "~ $- '"- Water Sample Collected by ~,~"*~ ~ "'~'~" Date ~',/'~ Water Sample Test Results .5",~ 7~,~' '~- ~c~,.~, ~ Comments g,z.'~,~. -~-~,¢,~-~,~e~' ~ ~ ;~" ,~.~ B. SEPTIC/HOLDING TANK DATA Date Installed ? ~7].., ,,T,~.~. Size Standpipes (Y/N) ~ Air-tight Caps (Y/N) Depression over Tank (Y/N) , Pumping/Maintenance Contract on File (Y/N) Holding Tank High-Water Alarm (Y/N) No. of Compartments Foundation Cleanout (Y/N) Date Last Pumped ; for Temporary Holding Tank Permit (Y/N) Separation Distances from Septic/Holding To Water-Supply Well <~ ~ ' ,... ¢~i~,~ To Building Foundation To Property Line //_2 '/- To Disposal Field To Water Main/Service Line /0 To Stream, Pond, Lake, or Major Drainage Comments Page 1 Of 2 72 026(H/84) C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata Date Installed ?'~ Width of. Field Square Feet of Absorption Area Depression over Field (Y/N) Results of Last Adequacy Test Separation Distance from Absorption Fiel/d: To Water-Supply Well ~ ~ ~ To Building Foundation ~ ~ / Lot //,J~ ~. To Water Main/Service Line '/~ ~ To Stream/Pond/Lake/or Major Drainage Course To Driveway, Parking Area, or Vehicle Storage Area Comments --¢'~ /,~z'Ccv,. ¢¢."/'4¢~'~--'~ Type of System Design Length of Field ¢~' '/ Depth of Field ¢'/~'~ "' Gravel Bed Thickness '~' ~' ¢~ Standpipes Present (Y/N) ~ Date of Last Adequacy Test To Property Line To Existing or Abandoned System on ; On Adjoining Lots To Cutbank (if present) D. LIFT STATION Date Installed Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for Electrical Codes (Y/N) Dimensions Manhole/Access (Y/N) "Pump Off" Level at Vent (Y/N) Pumping Cycles during Adequacy Test. Meets MOA Comments ** Check Permitted Bedroom Rating Against HAA Request ** I certify that I have checked, verified or conformed to all MOA and HAA guidelines in effect on the date of this inspection .:~ Signe~~ Date MOA No. ~"~ Company Receipt No. Date of Payment Amount: $ z:~X Page 2 of 2 72-026 (11/84) Engineer's Seal EAGLE RIVER ENGINEERING SERVICES Lou Butera P.E. P.O. Box 773294 Eagle River, Alaska 99577 Telephone (907) 694-5195 9/13/85 Su~an Oswalt Municipality of Anchorage Health Department 825 L Street Anchorage, Alaska 99501 MUNICIPALITy OF ANCHORAGE DEPT. OF HEALTH & ENVIRONMENTAL PROT£CTtoN ~3~ef:Lot 2 Suetawn Estates#1 ~Dear Susan; This letter replaces the one dated 9/12/85. Caulder couplings could not be placed on the septic tank connections as these con- nections were made by cementing the cast iron pipe into the concrete septic tank. The connections were in excellent condition and there is no danger of seepage. Please keep the enclosed photos for your files. If there are any questions or concerns please call me at my office 694-5195. Sincerely ~ Lou Butera P.E. unicipaHty P.O. BOX 6650 ANCHORAGE, ALASKA 99502-0650 (907) 264-4111 TONY KNOWLES, MA YOR DEPARTMENT OF HEALTH & HUMAN SERVICES September 12, 1985 Eagle River Engineering Services P.O. Box 773294 Eagle River, Alaska 99577 Subject: Lot 2 Sue Tawn Estates Subdivision #1, WR85-010 This Department hereby reinstates a previous State DEC waiver to 87 feet for the separation distance between the existing septic tank and well on the subject lot. This waiver is valid for a three bedroom single family dwelling. Changes to the existing system will require that all sewer and water components be brought into compliance with current State and Municipal law. Sincerely, Susan E. Oswalt Acting Program Manager On-site Services SE0/ljw Mike Lewis State of Alaska Department of Environmental Conservation Ah~CHORAGE/J~ESTER."I DISTRICT OFFICE 437 "E" STREET SUITE 303 ANCHORAGE, ALASKA 99501 ~ly 23, 1985 Eagle River Engineering Services P.O. Box 773£~4 Eagle River, Alaska 99577 SUBJECT: Lot 2, Sueta~n Estates, C.hugiak, Alaska ( 8621 -!~A-O13 ) Dear Sir: You are hereby notified that the waiver of 87 fto horizontal separation between the well and septic tank for subject property is revoked. Upon receiving information for the )~nicipality Of Anchorage it was found that there was separation distance of only 50 ft. from the septic system to a creek on the East side of the ~bJect property. It is required by today's regulations that this distance to ~ I00 ft. In waiver request submittals, State regulations specify that waiver request for all ~aters subject to contamination rx~st be clearly identified as to distance and size of that ~ter body. In your report you failed to identify this water body and so therefore, your waiver request has been revoked. If you have any questions, please contact me at 274-2533. $tncerel ¥, ~.lichael P. Lewis Environmental Engineer l. IPL/msm EAGLE RIVER ENGINEERING SERVICES Lou Butera P.E. P.O. Box 773294 Eagle River, Alaska 99577 Telephone (907) 694-5195 July 17, 1985 Susan 0swalt Municipality of Anchorage Health Department 825 L Street Anchorage, Alaska 99501 Ref: Lot 2, Suetawn Estates #1 Dear Susan; I have performed a health authority inspection on the above referenced lot and have encountered several separation distance that should be brought to your attention. These distances all have a legitiment reason for existing, ie. priority dates or waivers, and I have listed them for your review. 1. septic tank and leach field separation to creek less than 100'. (installed prior to State regulation 10/73.)-~ 2. well to septic tank separation distance 87 feet. waiver obtained 7/12/85.)f 3. septic leach field directly adjacent to property line. (approved by Municipality in that location 7/73.) If there are any questions or concerns please call me at my office 694-5195. Sincerely, Lou Butera P.E. }!4FAGLE RIYERENG][NEERINGSERVi[CE$ ~ ~ ~ LOU Butera P.E. ' ~;~..g~ P O 'Box 773294 ~~~ E agc ~{ (,er, X laska 99577 July 15, 1985 Mr. Michael P. Lewis State Of Alaska Department of Environmental Conservation 437 "E" Street', Suite 303 Ref: Lot 2~ Suetawn Estates #1, Chugiak, Alaska 8521-WA-011 Dear Mr. Lewis: In previous excavation to install a monitor tube in the above referenced leach field it was found that the system was installed using cast iron pipe with No Hub, hose clamp type coupl- ings. The connections were found to be' in good condition and it is assumed that this is the case at the inlet of the tank which was not uncovered. From my inspection of the leach area- I am reasonably sure that the tank area would have the same type construction and ask that you approve this waivier. If there are any questions or concerns please call me at my office 694-5195. Sincerely ~ Lou Butera P.E. ,J . i 8ILL SHEFFIELD, GOVERNOR ANCHORAGE/WE. SfLRN DISTRICT OFFICE 437 "E" STREEf, SUITE 303 ANCHORAGE, ALASKA 99501 274-2533 July 12, 1985 Mr, Lou Butera, P. E. Fagle River Engineering Services P. O. Box 773294 Eagle Riw~r, Alaska 9~577 SUBJECI~: Horizontal Separation Waiver Between Well and Septic Tank, I~t 2, Suetawn Estates Subdivision # 1, Chugiak, Alaska 8521-WA-011 Dear Mr. Butera: The Department has reviewed the subject waiver request and hereby con- ditionally waives the horizontal separation between the well and septic system to 87 feet on the subject property for a 3 bedroom siu~le family residence only. Waiver is conditionally ~approved upon the receipt~by the engineer giving assistance tha~ the present septic ta~k is water tight and has been equiped with:Water tight couplings on it's inl~.and outlet con- nections. I:[ yo~u have any qaestions, please co~t~C~ me at 274-2533. ~ ~ Sincere. ~y, ' Michael P. Lewis Environmental Engineer ~L/dd