Loading...
HomeMy WebLinkAboutEAGLE RIVER VALLEY RANCHETTES LT 1AEogle River Volley Ranch ttes Lot IA 050- 221 -34  Municipality of Anchorage Development Services Department ~:~ Building Safety Division On-Site Water and Wastewater Program, 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 Page of www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: OS¢{ttO-~5 PID Number: O50- TZi- 3d Name: ~lGm~5 ~;~?.~ WastewaterSystem: U New ~ Upgrade , [ AK ABSORPTION FIELD Phone: Number of Bedrooms: ~ ~ DeepTrench ~ Shallow Trench ~ Bed ~ Mound ~ Other: Soil Rating: Total Depth from original grade: LEGAL DESCRIPTION ~.~[¢ Ft. Block: Lot: Subdivision: ,,~, ~ Depth to pipe bottom from original grade: Gravel depth beneath pipe: Ft. Township: Range:/' Section: Fill added above original grade: Gravel Length: Ft. Ft. Well: ~;~ ~ New U Upgrade Gravelwidth: Ft. Number of lines: ~ Distancebe~eeniines:Ft. Classifi~tion (Private, A, B, C): Total Depth: Cased to: Total absorption area: Pipe Material: Ft. Ft. Ft= Yield: I Pump Set at: Casing Height Above Ground: ~ ~,. ~. TANK SEPARATION DISTANCES ¢ Septic ~ Holding ~ S.T.E.P. ~ Other: ~ Manufacture~: Capacity: To Septic Absorption Li~ Holding 'ubli~Private Tank Field Station Tank SewerLine Material: . / Number of Compadments: SuCa~Water ~'~ ~ / LIFT STATION Lot Line ~ i~~ Size: Man~a~uren Foundation ~ ;+ "Pump on" level at: "Pump o~' level at: I High water ala~ at: in. in. in. Cu~ain Drain ~ 0~ Pump Make & Model Electri~l Inspections pe~ormed by: Remarks: ~['~i~ ~¢1[ ~ ~,,~C,F, 60~ ~ ~ Lo,rich and Description: BENCHMARK fO0 ~t. Inspections pefformed by: L~ b[~.~ Dates: 1" dz 'Oil 2~d , ,z~- ;" Development Se~ices Depa~ment Approval {. ,/;::~}(~}. Conditional Approval Date: ~¢,~~~::: Reviewed and approved by: ~" I .'- LoS lA SWING T/ES ': I A C 22.0' 31.0' .: .'.--.. 0 23.5' 37.5' j ~ A ~1 E 25.0' 40.5' j I E~o C INSTALLEONE1VI250GALLONSTEELSEPTIC CONNECTEO TO EXISTING CRIB ABANDONED EXISTING SEPTIC TANK PER MOA J CODE REOUIREMENTS EgGLE RIVER V~LLEY RANCHETTES I 25 0 25 50 75 SCALE, l' = $0 FT, A B C 22.0' 3hO' O 23.5' 37.5' E 25.0' 40.5' : ' NOTE: SUBDIVISION SERVED BY PUBLIC WATER. NO WELLS ' WITHIN 200 FEET OF PROPOSEO SEPTIC TANK · ~ REPL4CEMENT SITE. -- 5 FEET CLIVER DOUBLE / N CLEANLIUT$ ~ - _ £~V.=~ZB' FLIUNflA TILIN i ~ ~- ~ £LEANLIUT · = ~ r~.o' ~.:~.o' EXZrT DRAINFIELD ~ SCAL~' 1' = 50 FL BENCH raNK ASSUMED E~VATION ~ FEET SPURK~ND ENGINEERING EAG~ RI~R V~Y R~CHETTES LOT lA SEPTIC SYSTEU ASBUILT 20~ W f5~H. AVENUE m~E: WAY ~, 20~ ARCH. AK. 9950~ ~OW NIlPPEI PENMIT ~ OSP ~055 PID ~ 050-~-34 ENVNL]A,DI, D~6 Permit Number: Tax Code Number: Work Type: On-Site Wastewater Disposal System OSP111055 05022134000 Septic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Upgrade Permit Effective Dates: May 11, 2011 to May 10, 2012 Design Engineer: SPURKLAND ENGINEERING Subdivision: EAGLE RIVER VALLEY RANCHETTES Site Legal Address: EAGLE RIVER VALLEY RANCHETTES LT lA G:0054 Owner/Address: KLIPPEL THOMAS F & MARY 19114 MAN O WAR EAGLE RIVER AK 995778335 Permit [. e l a r [m. e n. t Site Mailing Address: 19114 MAN O WAR RD, Eagle River Lot Size in Sq Ft: 17955 Total Bedrooms: 3 This permit is for the construction of: N Disposal Field Y SepticTank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Date: ::- . ' .' UNICIPALITY Community Development Department ~ Development Services Division On-Site Water & Wastewater Program Mayor Dan Sullivan OF ANCHORAGE Phone: 907-343-7904 Fax: 907-343-7997 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. .C.:7,C,-- Z~.i- ~.5'/ Property owner(s) I<i,pp .l Mailing address i~fil~ /v~c,,,~-©--i,,V:~c- Site address -- ~Ai~n~-- Day phone Legal description (Sub'd., Block & Lot) Legal description (Township, Range & Section) Lot Size Sq. Ft. Number of Bedrooms._"z'., THIS APPLICATION IS FOR: (~ all that apply) Absorption Field Septic Tank Holding Tank Privy Private Well Water Storage THIS APPLICATION IS AN: Initial [] Upgrade [~ Renewal [] THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. ( r r or authorized agent) Jsh Fees: ~,CI~ "~"" Date of Payment: Receipt Number: Permit No. Waiver Fees: Date of Payment: Receipt Number: Waiver No. G:\Building\On Site\Forms\Client Forms\Permit App_010411 .doc (Rev. 1111 ) Environmental Consulting and Design Municipality of Anchorage Development Services Department Building Services Division On-site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 May 3,2011 Subject: SEPTIC TANK PERMIT APPLICATION EAGLE RIVER VALLEY RANCHETTES LOT lA Ladies and Gentlemen: We are submitting an application to upgrade the septic tank for this lot. The existing septic tank serving the above referenced property is 42 years old and the owner would like to replace it. The submittal consists of one (1) drawing showing the present improvements on the lot and the proposed improvements of the lot, of which only the septic tank is subject to this permit application. There are no wells within one hundred feet of the proposed replacement site. The installation of this septic tank will not prevent wells and septic systems from being installed on the adjacent lots. There are no developed or natural surface / sub surface drainage courses within 100 feet of the proposed septic tank location. The proposed septic tank will not change the general slope of the area. Ponding and/or concentration of surface runoff will not result from this installation. If you have any questions or are in need of additional information please contact me at 279-3916. Sincerely, Lars Spurkland, P.E. 203 West 15th Avenue Suite 202, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (907) 276-6013, SpurklandEng~gci.net MAN-D-P/AN RDAD I ..:-.'-....:_. ': I I ~ INSTALLNEWI250GALLONSTEELSEPT/C CONNECT TO EX/STING CRIB ABANDON EXISTING SEPTIC TANK PER I~OA CODE REOUIREI~ENTS I 25 0 25 50 75 $CALE~ I' = 30 NOTE: SUBDIVISION SERVED BY PUBLIC WATER. NO WELLS WITHIN 200 FEET OF PROPOSED SEPTIC TANK REPLACE/~ENT SITE. D~U~E /-- 5 ?EET C~VER J_ N~ I C:EAN~UTS ~ - _ _ / ~ FBUNDA TIllN i ~ ! ~ ~ ~- ~ CLEAN£UT 1250 GALLDN SEPTIC TANK ~,,. EXIST BRAINFIELB ~ ~ ~ ~ %AR~ SPURKLAND ~,~ ~:~ No CE-Z~SO0 85 0 ~5 50 75 i00 185 150 SCALE~ l' = 50 FL BENCH UARN · "A" ON SITE P~N ASSU~ED ELEVATION I00 FEET SPURK~ND ENGINEERING EAG~ RI~R VALLEY R~CHETTES LOT 1~ SEPDC SYSTEW DESIGN 20~ · 15TH. A VENUE ANCH. AK. 99501 TOW KLIPPEL DATE: WAY ~, 201~ (907) 279-5916 1~114 ~AN 0 WAN ND., EA~LC RIVEN, AN ~77 PENMIT ~ PID ~ 050-~]-34 ENVNL]A,~],~5 Environmental Consulting and Design Single Family On-site Wastewater Disposal System Construction and Material Specifications Subject Property: Eagle River Valley Ranchettes Lot lA Date: May 3, 2011 General: 1. The owner shall contract with a contractor to perform the work outlined in these specifications and plans in accordance with the attached MOA permit. There is not contractual arrangement between the contractor and the Engineer. The Engineer shall be the owner's representative and will inspect the work to document the contractors activities. Final acceptance of the contractors work rests with the owner and the MOA. The scope of the work includes the installation of a new 1250 gallon septic tank. The location of the drain field is shown on the attached site plan drawings. All components of the proposed septic system must be constructed a minimum of 100 feet from any surface water or water wells in the area. A minimum of 4 feet of earthen cover is required over the septic tank. If less than 4 feet of cover is available, 2-inch thick, 40 psi, direct bury board foam shall be installed directly over the septic tank and all installed piping. Construction shall be in accordance with the approved site plan and design drawings and any special provisions noted on the Municipal well and/or septic permit. All materials, components, workmanship and construction practices shall comply with the Municipality of Anchorage's latest ordinances regarding wells and septic systems, as well as MOA, Development Services Department, On-site Water and Wastewater Program (DSD) policies. The contractor is responsible for obtaining all underground utility locates, layout of the proposed system, and verifying and maintaining all required separation distances to lot lines, surface water, wells, steep slopes, etc. The property owner shall be responsible for final grading any depressions formed from settlement of backfill material. The property owner is also responsible for vegetation of all areas disturbed by septic system installation activities. Contractors installing wastewater disposal systems must be certified to do so by the MOA DSD, On-site Water Wastewater Program. Property owners installing their own systems must receive advanced approval from MOA DSD prior to system installation activities. The contractor shall ensure that ALL materials being used are in compliance with the most current guidelines established by the Municipality of Anchorage. Refer to "Standards and Specifications for Component Parts and Materials Used in the Construction of On-site Wastewater Disposal Systems", Dated December 2000, as provided by MOA DSD, On-site Water and Wastewater Program. 203 West 15th Avenue Suite 202, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, Lspurkland~gci.net Environmental Consulting and Design Septic Tank Installation: 3. 4. 5. 6. w 9. 10. 11. 12. 13. 14. 15. 16. A new septic tank, of the size specified in the design drawings, shall be procured from a qualified manufacture/supplier if the existing septic tank is found to be defective. Construction shall include two 4" diameter cleanouts for pumping access. The burial rating of the tank shall be adequate for the actual burial depth encountered. The tank shall be level and sufficiently bedded to prevent settling of shifting of the tank. All standpipes on the tank shall extend a minimum of 12inches above the final grade. Tanks installed with less than 4 feet of cover shall be insulated. The sewer service line from the house to the tank shall have a minimum slope of 2% unless prior approval is obtained from the engineer. The inlet and outlet lines from the tank shall be bedded in drain rock or the soil shall be sufficiently compacted to prevent future settlement of the soil. Septic tank inlets, outlets and cleanouts shall be fitted with water tight couplings. A cleanout shall be installed ! to 4 feet from the foundation. Post tank cleanouts shall be installed per MOA requirements. Does not apply to pressurized lines. In areas with high ground water, the septic tank shall be sufficiently anchored to resist buoyancy forces when there is not adequate soil cover to resist uplift force. The contractor shall refer to the engineer for direction regarding this matter. The tank backfill shall be graded sufficiently to ensure positive drainage away from the tank. All holding tank and lift stations shall have an audible and visible alarm inside the residence being served. All lift stations shall be wired in compliance with all IVlOA guidelines and the Uniform Electrical Code. A municipal electrical permit and inspections must be obtained where required by the MOA. The contractor shall verify that the septic tank/lift station is a minimum of 100 feet from any residential water well, :[50' from any class 'C' well and 200 feet from any community water wells. Additional separation distances must also be maintained. The contractor shall remove or abandon the existing tank in compliance with the Unform Plumbing Code. Tnspections: A minimum of one inspection is required by the Municipality of Anchorage. These inspections must be conducted under the supervision of a Professional Engineer licensed to practice in the State of Alaska. The septic tank may be set in place, but may not be backfilled. The contractor shall provide a legible copy of all field notes relating to system layout and construction to the engineer for the use in preparing the record drawings. 203 West 15th Avenue Suite 202, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, Lspurkland~gci.net Environmental Consulting and Design I The contractor shall coordinate all inspections with the Engineer. A minimum of 24 hours notice is required prior to the start of construction. Tf necessary, a preconstruction meeting will be held on-site. 203 West 15th Avenue Suite 202, Anchorage, AK 99501, Phone: (907) 279-3916 Fax: (866) 354-1597, Lspurkland~gci.net ' HEALTH DEPARTMENT ~ 327 EAGLE ST. ANCHORAGE, ALASKA 99501 279-2511 INSPECTION REPORT ON-SITE SEWAGE DISPOSAl. SYSTEM NAME LOCA,,O . AL DESC IPT,ON SEPTIC TANK: ' ("/ D,STA.CE E OM Wet, LIQUID CAPACITY ADDRESS . GALLO.S. COMPARTMENTS INSIDE LENGTH INSIDE WIDTH DEPIH SEEPAGE SYSTEM: SEEPAGE PIT: NUMBER OF PITS LINING MATERIAl NEAREST LOT LINE OUTSIDE DIAMETER OR WIDTH // ~-- , LENGTH //~'~'- , DEPTH ('~_,"Z- /~/~ ~; D~STANCE FROM WELL /'~' ~' / , BU~LD~NO FOUNDAT~ON.~ · IOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) SQ. FT. TILE DRAIN FIELD: DISTANCE FROM WELL NUMBER OF LINES ABSORPTION AREA , FOUNDATION DISTANCE BETWEEN tINES SQ. FT. LENGTH OF EACH LINE DEPTH: TOP OF TILE TO FINISH GRADE NEAREST LOT LINE TRENCH WIDTH TOTAL LENGTH OF LINES IN. TOTAL EFFECTIVE .DEPTH OF FILTER MATERIAL BENEATH TILE IN. ABOVE TILE WELL: -WpE"-'~/ L. (-)"'[-! L,-~l~t~-'~ DISTANCE FROM WATER , , BUILDING FOUNDATION.__SAMPLE , NEAREST NEAREST SEPTIC SEEPAGE OTHER LOT LINE , SEWER LINE , TANK , SYSTEM , CESSPOOL , SOURCES__ DISTANCES: DIAGRAM OF SYSTEM .... ~ , ........... :.,l :~ .... DATE ~/4~'~ APPROVED OAAB-HD-~ tlEALTil DEPARTMENT ~,U~ 327 Eagle St. Anchorage, Alaska 99501 279-2511 SEWAGE DISPOSAL SYSTEM - APPLICATION & PERMIT ..... """E ADDRESS LOCATION DF .,STALU~TIO, ~,~ ~.,~ ,.~o~ .. APPLICATION ~0 INSTALL: SE~IC TANK~, SEEPAGE PIT ~, DRAIN FIELD ~ ., OTHER FINANCED THROUGH ~ TO BE INSTALLED EY__ ~ ' x~ ~ ANTICIPATED DATE OF C ~ PERCO~TION TEST RESULTS BELOW TO BE FILLED OUT BY HEALTH DEPARTMENT AS DESCRIBED BELOW. SIZE OF UNIT TO BE S DIAGRAM OF SYSTEM DISTANCES: Health Authority I certify that I am familiar with the requirements of Greater Anchorage Area Borough Ordinance No. 28-68 and that the above described system is in accordance with said code. DATE APPLICANTS SIGNATURE GREATEK iNCHORAGE AREA HEALTII DEPARTMENT 327~..~,~";'le-.~t. ' ' ' ' ~ Anchorage, Alad~a 99501 SEWAGE DISPOSAL SYSTE~ - APPLICATION & PERMIT )..)ROUGH No. 279-2511 NAME OF APPLICANT- RESIDENCE ADDRESS LEGAL DESCRIPTION APPLICATION TO INSTALL: SEPTIC TANK TO SERVE THE FOLLOWING FACILITY FINANCED TH'ROUGH PERCOLATION TEST RESULTS '"/ MAILING ADDRESS '-'~'~'J <//~ 7 i~HONE NO. LOCATION OF INSTAL~TION -~" .... ' / ,' " , SEEPAGE PIT ~' ,DRAI~ FIELD ,OTHER ' TO BE INSTALLED BY ~ ~ n/~, 4.2~ * ,. ..-' ' ANTICIPATED DATE OF COMPLETION ~'5~/ 4'/}.,~ )l ~xt' (4/ BELOW TO BE FILLED OUT BY HEALTH DEPARTMENT '5 c'"" '- ~L~ . . SEPTIC ,TANK SIZE THiS iS TO SERVE AS'~ '~ ..... :', '-1 / (//-",'' PERMIT TO INSTALL A ' ~" ':%~ AS DESCRIBED BELOW. SIZE OF UNIT TO BE SERVED . .': . ~L~.,-~-'2;, / ' ' / TYPE '' 'r '~ ': ~ '''TYPE ....; · SEEPAGE AREA .? ~ .; '. o . ~'/4 ~ ^~-: DIAGRAM OF SYSTEM ", "' DISTANCES: Health Authority I certify that I am familiar with the requirements of qreater Anchorage Area Borough Ordinance No. 2~-68 and that the above described system is in accordance with said code. c'~5 ,~ r. ('' ~ APPLICANTS SIGNATURE DATE. f ) I DEPT. OF ENVIRONMENTAL CONSERVATION / ANCHORAGE/WESTERN DISTRICT OFFICE 437 "E# STREET. SUITE 303 ANCHORAGE. ALASKA 99501 BILL .SHEFFIELD, GOVERNOR Telephone: Address: 274-2533 To Whom it May Concern: ~: ~ ~'~ . I / ,, According to records op~.~.~le in this office the ~ .....-, .- ,t. I A ~, I I.~/'..i:~, ~l~:~:'~;ys,en~ is in complia,ce with the St~e Drinking Water Regulations Sincerely.