HomeMy WebLinkAboutEAGLE RIVER VALLEY RANCHETTES LT 33C.. ' ~ MUNICIPALITY OF ANCHORAGE · L~ DE ITMENT OF HEALTH AND HUMAN SERI~ ES ~ Environmental Health Division 825 "L" Street. Anchorage, Alaska 99502, Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT ~.m~ DISTANCES /7/O'~Z, 0 /~_Z./~' ~ SEPTIC ABSORPTION ~e~;.~ TANK FIELD WELL LOt UIOCk I Subdlv,s~o. ~ Township. Range, Section AS-BUILT DIAGRAM IS~ow Iocahof~ Of we,. septAc system, prope~y hnes, Iounaat~o~. driveway, wa~er bod~es, elcl ~ Mater~ NO. Of ~mpadmenls WELLS SR B 196X I ~ ki~R~ AK YY~Ii Cedily thai this i~p~ion was peflormed ac~rding Io all Health Depa.ment Approval: Date. ' 72-013 (3/85) PERM I '! NO: [)ATE ISSUED: APPLICANT: ADDRESS: CONTACT PHONE: LEGAL DESCRIP: LOT SIZE: MAX BEDROOMS: _ I TY OF D~PARTMENT Or' HEALTH AND ENVIRONMENTAL Pt~OTECTION 825 L STREET, ANCHORAGE., AK 99501 Ol~l S I TE 860574 10/03/86 HORLD BELt{ ~ S&S ENGINEERING EAGLE RIVER, AK ~762181 ~64-47eU Sr - ; -'--- IT 99577 ~UBDIVISION: E. R. VAL. RANCHETTE LOT: 53C SECTION: 7 TOWNSHIP: 14N RANGE: 1W 19600 (SQ. Fl'. OR ACRES) BLOCK: NA Listed below are the options available to you in des'igning your septic system. Choose the option that best Fits your site. DEPTH TO PIF'E BOTTOM. (Fl'.) GRAVEl_ DEPTH '(Ff.) TOTAL DEPTH (F'lr'. ) GRAVEL'" WID]'H (FT.) GRAVEL LENGTH (FT.) GRAVEL VOL(UME (CU. YDS. ) TANK SIZE (GALS) SOIL RATING (SQ.FT. /BR) TI:,IENI2.1-1 BFD W. DRAIN ~/. 0 w-- 4.0 4.0 10.0 4.5 7.5 P_.~ 24.0 5.0 ~67.0 ~'- ' 45.0 87.0 ~* 4(~}.4' '- ' 40.0 64.5 ~00.~] ** 1,000.0 *~. 1.,000.0 *~ GRAVEL LENGTH )* 75 FT. REQUIRES MULTIPLE. RUNS (NOT EXCEEDING 75 FT. EACH) TANK MUST HAVE AT LEAST ]'WO.COMPARTMENTS I cer'li~y that: 1. I am familiar with the requirements for on-site sewers and wells as set ~orth by the MunicipaIity o~ Anchorage (MOA) and the State o~ Alaska. R. I will install the system in accordance with all MOA codes and regulations, and in compliance with the design criteria o~ this permit. 3. I will adhere to all MOA and State o~ Alaska req(~irements ~or the set back distances ~rom any existing wGll, wastewater disposal system or public sewerage system on this or any adjacent or .nearby lot. 4. I understand that this permit is valid For a maximum of 3 bedrooms' and any enlargement will require an additional permit. IF A LIFT,STATION" IS INSTALLED IN AN AREA COVERED BY MOA BUILDING CODES, THEN (1) AN ELECTRICAL F'ERMIT AND INSPECTION MUST BE OBTAINED; (-~) AS-BUILTS .WILL NOT BE APPROVED WITHOUT-AN ELECTR~CA.L ELECTRICAL WORK M ~LJG~ BE DONE BY/ A .~_IC~-D ' AF'F-LICANT: H~I:~LD BELK , [/ INSPECTION REPORT; AND (~) THE ELECTRICIAN. GRE~'-'~ ANCHORAGE AREA BOr"~'~H Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME~¢J~'C~"~;~e~ MA,L,NGADDRESS~ 7/~ ~/!~r LOCATION LEGAL DESCRIPTION /--' ~ SEPTIC TANK: DISTANCE FROM WEL' -- MANUFACTURER// "'; ., NUMBER OF MATERIAL ~'t') Yl C//'e ["P~ COMPARTMENTS / INSIDE LENGTH .. INSIDE WIDTH. LIQUID DEPTH ~'/' t. IQUID CAPACITY f~:~O GALLONS. SEEPAGE PIT: NUMBER OF PITS I DIAMETER __ OR WIDTH /~ j LENGTH/~, DEPTH / LINING MATERIAL CRIB SIZE: DIAMETER DEPTH ~- DISTANCE FROM: WELL TOTAL EFFECTIVE BUILDING FOUNDATION ..~.(,~/,'"'~'* NEAREST LOT LINE~'~'O~' ABSORPTION AREA (WALL AREA) '~' ADDITIONAL ABSORPTION WELL: TYPE CONSTRUCTION BUILDING NEAREST NEAREST FOUNDATION , LOT LINE , SEWER LINE CESSPOOL , OTHER SOURCES APPROVED. , DISAPPROVED REMARKS DEPTH DISTANCE FROM: SEPTIC SEEPAGE ., TANK , SYSTEM DISTANCES:, INSTALLED BY= ~/-~ ~rl/'//O~Y~ PiPE MATERiAL:C:RI/ C~,~,'~ i/Oh LOT SLOPE: Z eeef REMAR~:./~'a ~;/ Form No. EQ-031 DIAGRAM OF SYSTEM ~ GreATEr ANChOrAge Area Borough DEPARTMENT OF ENVIRONMENTAL QUALITY 3330 *'C" STREET ANCHORAGE, ALASKA 99503 TELEPHONE 274-4561 PERMIT NO. o SEWAGE DISPOSAL SYSTEM ~ APPLICATION AND PERMIT/x~.~.~/_~.~.,,~7 PHONE~ INSTALLATION LOCATION LEGAL DESCRIPTION INSTALLATION OF: SEPTIC TANK ~'/ ~' SEEPAGE PIT. ~ FINANCED THROUGH TO BE INSTALLED BY SOIL TEST RESULTS ~ ~~J DRAIN FIELD OTHER NOTE~ THIS PERMIT IS NOT VALID WITHOUT ~OIL TEST FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING Of ANY SYSTEM V~HOUT FINAL INSPECTION BY THE DEPARTMENTOP ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK SIZE AREA TYPE MINIMUM DISTANCES, REQUIREMENTS FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIT ~ / DRAIN FIELD SEPTIC TANK TO SEEPAGE PIT WALL SEPTIC TANK ~--/ . SEEPAGE: PIT TO NEAREST LOT LINE. WELL TO SEF~J'IC TANK /~")~) / DRAIN FIELD ~ / WATZ" MAiN TO SEPTIC T~NK, K~ DRAIN FIELD /~ / SEPTIC TANK, , ~,~/~ SEEPAGE PIT TO RIVER, LAKE. STREAM. . ALSO CONSIDER AREA WELLS, SEEPAGE PIT /~ / CAST IRON INTO AND OUT DF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION S FEET INTO UNDISTURBED SOIL. a INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. · GRAVEL BACKFILL CONFORM TO E~ORDUGH REGULATIONS REGARDING INSTALLATION, DIAGRAM OF' SYSTEM I I- I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF (~REATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE DATE ~;:2~.///.~,~, /~7-~ APPLICANT'S ,IGNATUR / Munlcl~llty of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICE~~ ~ 825"L"Street. Anchorag,e Alaska 99502-0650,~.~./~w ~,~ ~.,=.~,,~'~' .. ~_ , ~' SOILS LOG -- PERCOLATION TEST DATE PERFORMED: -~./ PERFORMED FOR' .~. ~/' 1 2 ? / WAS CROUND WATER ENCOUNTE.ED? 11 S L IF YES, AT WHAT O 12 DEPTH? p E Depth to Water After/~ 13 Monitoring? / -- ~' Date: Cross Net Depth to Net Reading Date Time Time Water Drop _... .----- Z / 1" Z/.',~ ~ ~ ~ o ~/~ ~ ~ly /~/~" ~- ', 3 ~ t~ " 7 /{~* ~ " , ~ ~/~, /~ . 7 ~/~" ,. 14- 15- 16- 17- 18- 19- 20- PERCOLATION RATE ~ (m~nutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN /~'~FT AND ~ FT COMMENTS ~ & g ENGINEERING ' ~ SR8 196X ~ ////~ // · ~ CERTIFY THAT THIS )'EST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELI~ EFFECT ON 'HIS DATE. DATE: 72-008 (Rev. 4/85) DRAWN .I '1 Municipality of Anchorage 1. . On -Site Water and Wastewater Program as� (907) 3434904 S A F E T Y Certificate of On -Site Systems Approval' PAl Parcel I.D. 050-984-'l 3 Expiration Date: 1. GENERAL INFORMATION: Complete legal description EAGLE RIVER VALLEY RANCHETTES; LOT 33C Location (site address) 18637 Twenty Grande Rd. *Eagle River, AK 99577 Current Property owner(s) Michelle Sprosty Day phone 907-317-4155 -Mailing address Real Estate Agent Day phone 2. TYPE 'OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ , Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual Individual Water Storage ❑ Holding Tank ❑ Community ClassWell ❑ -Community.. ❑-....;: Public Water System ® Public Sewer WaiverNariance request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ Waiver Fee Date of Payment •�15'J Date of Payment Receipt Number ��ar.> ti3� Receipt Number COSA# Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm: Garness Enoineerina Group, Ltd (GEG) Phone: '907-337-6179 Address: 3701 East Tudor Road, Suite 101- Anchorage, Alaska 99507 Engineer's Printed Name: Jeffrey A. Garness Date In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system in accordance with the guidelines and regulations established by the Municipality of Anchorage and industry practices. The reported results describe the condition of the system/s on the date/s of the evaluation. Separation distances were measured to readily identifiable features. Hidden defects or encroachments may exist that were not identified during the evaluation. The operational life of all wells and septic systems depend upon a variety of variables, including but not limited to, soil conditions, groundwater levels (that may fluctuate during the year), quality of construction (materials and workmanship), and the water usage of the family utilizing the system/s. These conditions can vary, and are outside the control of GEG. Satisfactory test results do not guarantee future performance of the system/s; therefore, GEG makes no warranty (express or implied) regarding the future performance of the well or septic system. GEG makes no representation whether an alternative well or septic system can be installed on the property in the event either of the current systems fail to perform adequately in the future. The content of this report is for the sole benefit of the person/party that retained GEG to perform the evaluation. Reliance upon the information provided in this report by any other person or party (including subsequent property purchasers) is not authorized, nor will it confer any legal right whatsoever. 6. DSD SIGNATURE System #1 System #2 Approved for Conditional approval for bedrooms with the following sti 3 V'!ly*2::K� S , ' " y r By: Original Certificate Date: The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist _ Septic System Advisory Well Flow Advisory Nitrate Advisory Arsenic Advis.ary..1 +, Other Legal Description: EAGLE RIVER VALLEY RANCHETTES; LOT 33C Parcel ID: 050-224-13 If more than 1 septic system on lot: COSA Checklist # 1 of 1 Structure served by this system 1 A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Comments AWWU WATER B. TANK DATA Age of tank(s) 47 years Tank type/material CONCRETE Measured operating fluid level in septic tank 63" ❑ Standpipes/foundation cleanout per record drawing Date of pumping 1/31/20 D. ABSORPTION FIELD DATA TRENCH IS A "SPILLOVER TRENCH" Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? ❑ Yes ❑ No ❑ Coliform bacteria is Negative Nitrate mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ❑ Arsenic less than MRL (ND) Collected by Date of Sample C. LIFT STATION ❑ Required maintenance completed Age of lift station years Lift station material Comments: N/A Which system tested (date installed) "10115186 Adequacy test date 1/24/20 ❑ ALL standpipes present per record drawing Results ❑✓ Pass For 3 bedrooms Total measured depth from grade 10.5 ft (max) Fluid depth prior to test 0 in Measured depth to pipe invert from grade **6•8+ ft (min) Water added 1008 gal ❑ N/A — pressurized field 2 New depth in ❑ Monitor tubes go to bottom of effective. If not, state 195 depth into effective Elapsed time min ❑ Code -required soil cover over field Final fluid depth 0 in ❑ System presoaked Absorption rate 450+ gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) NONE date of test) Gallons introduced 2022 gallons If yes, enter date NIA Comments/Deficiencies: 'PRESOAKED EXSISTING CRIB ON -123 8 TESTED EXSISTING CRIB ON 124. CRIB IS CONNECTED TO TRENCH. ALL ONE SYSTEM. "FOR 1986 TRENCH COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' ❑ Yes if No *5 Community Sewer Manhole/Cleanout > 100' ❑ Yes if No ft ❑ Yes if No Neighboring Tank > 100' ❑ Yes if No ft Private Sewer/Septic Line > 25' ❑ Yes if No Absorption Field on Lot > 100' ❑ Yes if No ft Holding Tank > 100' ❑ Yes if No Neighboring Absorption Fields > 100' if No ft Animal Containment > 50' ❑ Yes if No ❑ Yes if No ft ft If septic tank is under driveway comment below Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' ❑ Yes if No ft 0 Yes if No From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ❑ Yes if No *5 ft Surface Water > 100' ❑✓ Yes if No _ Property Line > 5' ✓❑ Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' ❑✓ Yes if No ft Private Wells > 100'✓❑ Yes if No Water Main > 10' ✓❑ Yes if No ft Community Wells > 200'✓❑ Yes if No _ Water Service Line > 10' ❑✓ Yes ** if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' ✓❑ Yes if No ft If absorption field is under driveway comment below Property Line > 10' 0 Yes if No ft Wells on Adjacent Lots: Water Main > 10' 0 Yes if No ft Private Wells > 100' Yes if No Water Service Line > 10' ❑✓ Yes if No ** ft Community Wells > 200' ✓❑ Yes if No Surface Water > 100'✓❑ Yes if No ft F. ENGINEER'S COMMENTS *MET CODE AT TIME OF INSTALL - DECK PILE MAY BE 0' TO CONCRETE TANK (SEE ATTACHED PHOTOS). —LOCATION UNKNOWN, BUT ASSUMED 10'+ PER 1986 INSPECTION REPORT. NO INLET BAFFLE ON SEPTC TANK. OUTLET BAFFLE WAS REPLACED (SEE ATTACHED PHOTOS) BY ARM SERVICES ON 2/25/20. 006000 �� G. ENGINEER'S CERTIFICATION I certify that / have determined through field inspections and review s/��DD of Municipal records that the above systems are in conformance with H MOA COSA guidelines in effect on this date. COSA Checklist yellow sheet Q CF, -7V53 0^ .. 3µ Za ro.fessio #AECC884 ft ft ft ft ft ft ft ft M ft Lot 33-A S 89059'15" E 133.0 10' Utility Easement Septic vent (typ) v� 0 O Chain link fence tf� o (tYP) co Lot 33-C O co T_ O co Notes: 1. This lot is served by a community well. 2. Asphalt location is approximate due to snow and icedn site. Asphalt S 89059'15" E 133.0 GRANDTWENTY ROAD ,�?'• ' . s `�'•� 9 th 4=� 00 •v • lizabeth L Walatka .0 �� ���F • 8036 - LS • �® �'1j �OSSIat1AA-•�®'1r 0, AS -BUILT NO CORNERS SET THIS DATE I hereby certify that I have performed a Mortgagee's inspection in accordance with ASPLS Standards of the following described property: LOT 33-C. EAGLE RIVER VALLEY RANCHETTES Anchorage Recording Precinct, Alaska, and that the improvements situated thereon are within the property lines and do not overlap or encroach on the property lying adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission lines or other visible easements on said property except as indicated hereon. Dated at Anchorage, Alaska Y�� this 27th day of February 2020 THOSE SHOWNN ON THE RECORDED . EASEMENTS RECORD, OTHER FRED WALATKA R ASSOCIATES, L.L.C. PLAT ARE NOT SHOWN HEREON FB 20-1, pg 18-19 BE 907-248-1666 Engineers and Surveyors UNLESS OTHERWISE NOTED. This drawing is a representation of conditions found at the time the mortgage location survey was performed. This document does not constitute a boundary survey and is subject to any Inaccuracies that a subsequent boundary survey may disclose. The information contained on this drawing shall not be used to establish any fence. structure or other improvements. This drawing shall only be used for a single property transaction. Use of this drawing by the original client or by others at a later date without the consent of Elizabeth L. Walatka is a violation of Federal Copyright law. Unless gross negligence is discovered, the liability extent of the preparer is limited to the amount of fees collected for services in preparation of this product. U :� 1 Lot 33 -BO Septic vents � deck 1 - 0 underdeck O 2.0 OH — — ` q , O 0 14.0 o SCALE: 1 "= 30' 2 sto0 frame N O Z House o z 35.4 Wood fence - 0 38' 14.6 J--43 Lot 32-C O co Notes: 1. This lot is served by a community well. 2. Asphalt location is approximate due to snow and icedn site. Asphalt S 89059'15" E 133.0 GRANDTWENTY ROAD ,�?'• ' . s `�'•� 9 th 4=� 00 •v • lizabeth L Walatka .0 �� ���F • 8036 - LS • �® �'1j �OSSIat1AA-•�®'1r 0, AS -BUILT NO CORNERS SET THIS DATE I hereby certify that I have performed a Mortgagee's inspection in accordance with ASPLS Standards of the following described property: LOT 33-C. EAGLE RIVER VALLEY RANCHETTES Anchorage Recording Precinct, Alaska, and that the improvements situated thereon are within the property lines and do not overlap or encroach on the property lying adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission lines or other visible easements on said property except as indicated hereon. Dated at Anchorage, Alaska Y�� this 27th day of February 2020 THOSE SHOWNN ON THE RECORDED . EASEMENTS RECORD, OTHER FRED WALATKA R ASSOCIATES, L.L.C. PLAT ARE NOT SHOWN HEREON FB 20-1, pg 18-19 BE 907-248-1666 Engineers and Surveyors UNLESS OTHERWISE NOTED. This drawing is a representation of conditions found at the time the mortgage location survey was performed. This document does not constitute a boundary survey and is subject to any Inaccuracies that a subsequent boundary survey may disclose. The information contained on this drawing shall not be used to establish any fence. structure or other improvements. This drawing shall only be used for a single property transaction. Use of this drawing by the original client or by others at a later date without the consent of Elizabeth L. Walatka is a violation of Federal Copyright law. Unless gross negligence is discovered, the liability extent of the preparer is limited to the amount of fees collected for services in preparation of this product. e GREATER ANCHORAGE AREA BOROUGH Department of Environmental Quality 3500 Tudor Road, Anchorage, Alaska 99507 279-8686 Date Received ,, ~- ~ - ~_~ Time of Inspection Date of Inspection , REQUEST FOR APPROVAL OF INDIVIDUAL SENER & WATER FACILITIES FOR A~proval Requested By: · · Anchn~anm BF QQ~n,~ Phone: Address' 902 Snuth [~n~; ~ _ ......... Prooertv ~mer: $~F ,. ~hone: Legal Description:__tot 33C Eagle R]vem,_¥a]%e¥ Ranchette~ Location: 5. Type of Facility to be Inspected: Sinqle Family Dw.11tn9 Number of Bedrooms: 2-3 ) Two 04 Thre~ 6. Well Data: Con~nunity Water A. T',/pe C. Construction 7..Sewage DisPosal System: A. Installed · 19'73 C. '.Septic Tank: 1. Sizej.Qj~ 2. B. Depth , D. 'Bacterial Analysis' Installer Hamtl~nn Fv~v~e~ng ~anufacturer, .~milte~ D. Seepage Pit: 1. E. Disposal Field: Size~2. ~aterial Total. ~ength of Lines 8. Distances: A. Well To: Septic Tank Be , Absorption Area , Sewer Lines , Nemrest Lot Line Foundation to Septic T~nk · Other Contamination "~ Absorption Area Absorption Area to Nearest Lot Line ReqlJe.~t for Approval of Individual Sewer & Water Facilities Pa.~e Two 9. Comments: Approval Valid for One Year 'From Date Signed Creater Anchorage Area Borough, Department of Enviro~mental Quality DIAGRA~I OF SYSTE~ ! certify that the information contained in this request for approval to be a true and accurat, representation of the subject sewer and water facilities located att Signed Date GREATER ANCHQ~GE AREA BOROUGH Department ot' Environmental quallt,y 3330 "C" Street. Anchorage. Alaska 99503: 274-4561 Date Received Septa be 25, 1973 Time of Znspection Date of ]:nsoecttoo,_ , September_ 25, "73 R]~QUEST FOR APPi:~OVAL OF INDTVTDUAI. .~WER & WATER FACILZTIES FO~ 1. Aoprova! Requested 6y~ SMllev~s Realty_. _ ,, Address'. ... P,O,..8ox_ 1086. Eaole Rtver ~AK ..... 2. ProoeT'ty Owner ~ 3. £.ega! Oescripttonc Lot,,,33Ct,Ea91e P, Jve~ Yal~ev Ral~chetts 4. Local':ertl 2D G~nd P~t Ea,qle Rtver 5. T.vOe of 'Facility to be InSpectecl~. Sine1= Famtlv O~elltn9 Number of Sedroomst 6. ~ell Oa~at A. Type C. Constructs on 7. Sewage Disposal System= A. ~n~at/ed Auq.73~ ¢, Septic Tank-= 1, D. Seepage Pti= E. Dispose! Field= B. T o_(2) ..... B, Depth .. D. Bacterial Analys~s'_... Phone, 694-P1 lfi Phone = 6. Installer 'H~m~ltnn Size 1~O0.6als 2. Manufacturer ,,mt1+,, .. Size 16xIGxlO 2. Mater~al COncrel~ Total Length of Lines, A. Welt To= Septic Tank ,Absorpt[on Area , Sewer Lines , Nearest Lot Line ,, Othe~ Contaminate. on . 8. Fr, undat, ion ~o Septic Tank "~ Ab'eO~ton A~a R'e~st-for ~.pproval of ,~divldua! Sewer ~. Wate'r F'aoilit.~.~i~ · Page Two g..C~ents:,. .. Aporo~D~,$approved .,: Dat. [ J Approval Valid for One Year Fr~ Date Signed ~Greater A~o~ge Area 8orough, Ue~ent of Enviro~ental ~altty OIAGRAM OF SYS'fE~ ! cart/fy that the information contained in this request for approval to be a true end accurate representation of the Sub.~eCt sewer and water fac.~ltttes located et, $1qned Oate[ ]500 Tudor Road, Anchorage, Alaska GRERTER AN~HORAG~ AREA BOROUGH Department of Environments! Ouallty Oats Received , August 28r, 1973,_' Time of Inspection ...... Date of Insoection . R£~JEST FOR APPRO1/AL' OP INDTV~DUAL SEWER & WATER FACiLITiES FOR F.H.A Anprove I Requested By ~ .Cous tneau.. & Ree.ves ._ _ A4d~ess~ BOX 7,63, .Ea~le Rtver,AK 99577 2. Pronert¥ Owner: 3. Legal Desctiption~ 4. LocetLon~ 5. T.v~e of Facility to be Inapected~ Number of ~edrooms,, l~.~e (3). 6. Wetl Data~ C. Cor~ttucti en 7. Sewage Di~osal.Systam~ A. ~nsta!led Aug C. Septic Tank~ P. 5eepaqePtt~ ~. Dlsposa~ Fteld~ D~stances: _.; Phone Phone Lot 33 C. Ea~le Rlve~ Valley Ranchettes Single Famtly Owelltng B. Depth_ -._.__ _ - = - D. Bacterial Anatysts Size 1000 Ga.la2. Size .16x16 , 2. Total Length of Lines Manufacturer Hamtlton Material _Con, rets ~tngs [nstallet Hamtlton ..... . . _ A. Well To~ Septic Tank , Absorption Area , Sewer Lines , Nearest Lot Line , Othe~ Contamination . B. Fnundation to Septic Tank 5a, "~ Ab$o:pt~on Area 26~ . C. Absorption Area to Nearest Lot L~ne , 20' · . rteq~, st for Approval .or X.n,--~lduat sewer &. water rao2~G2e~*~ · P~qe Two ,~ Lot 33C.,Ean1~ R~v~ U~]ley Q?~h~ . 9. Com~ents~ Approval Valid for One Year Fro~ Date Signed G~eater Anchoroqe Area Borough. Department of Environmental Quality DIAGRAU OF ~ ce:tl fy that the information contained in this request for approval to be a t~ue an~ accurate ~epresentat$on of the suB.Sect sawer and water facilities located Siqned Date