HomeMy WebLinkAboutWOODLAND PARK LT 12E-1• Municipality of Anchorage On -Site Water and Wastewater Program < (907) 343-7904 Certificate of On -Site Systems Approval Parcel I.D. 010-092-42 1. GENERAL INFORMATION: Complete legal description WOODLAND PARK; LOT 12E-1 Expiration Date: 7--7-1-/ Location (site address) 2221 West 34th Avenue *Anchorage 99509 Current Property owner(s) Dash Delores Trust Day phone Mailing address Real Estate Agent Sam Daniel Day phone 2274626 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual ❑ Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer WaiverNariance request for: Received by::fr � Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 59(a Date of Payment W!�p? Receipt Number 6536 -6 COSA# of)cm I 1 Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm: Gamess Engineering Group, Ltd (GEG) Phone: 907-337-6179 Address: 3701 East Tudor Road, Suite 101- Anchorage, Alaska 99507 Engineer's Printed Name: Jeffrey A. Garness Date: _ / In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system in accordance with the guidelines and regulations established by the Municipality of Anchorage and industry practices. The reported results describe the condition of the system/s on the date/s of the evaluation. Separation distances were measured to readily identifiable features. Hidden defects or encroachments may exist that were not identified during the evaluation. The operational life of all wells and septic systems depend upon a variety of variables, including but not limited to, soil wnditions, groundwater levels (that may fluctuate during the year), quality of construction (materials and workmanship), and the water usage of the family utilizing the system/s. These conditions can vary, and are outside the control of GEG. Satisfactory test results do not guarantee future performance of the system/s; therefore, GEG makes no warranty (express or implied) regarding the future performance of the well or septic system. GEG makes no representation whether an alternative well or septic system can be installed on the property in the event either of the current systems fail to perform adequately in the future. The content of this report is for the sole benefit of the person/party that retained GEG to perform the evaluation. Reliance upon the information provided in this report by any other person or party (including subsequent property purchasers) is not authorized, nor will it confer any legal right whatsoever. 6. DSD SIGNATURE System #1 Approved for 3—bedrooms System #2 Approved for _ bedrooms Disapproved Conditional approval for bedrooms, OF /.. IryA ....n= ��ppro/ess0�. rnxr.�Fn Qyi�Y OF,yN J T with the followA st' 5:E �C. 1�ANn IT Original Certificate Date: The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 b an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineers work. ATTACHMENTS: COSA Checklist_ Nitrate Advisory Septic System Advisory Arsenic Advisory y>C Well Flow Advisory Other cosnbwasheet 10-10-12.doo If more than 7 septic system is on the lot: . (_ G COSA Checklist # _of Q1_+ Structure served by this system _ a � Q Certificate of On -Site Systems Approval Checklist g WOODLAND PARK; LOT 12E-1 � Legal Description: Parcel ID: 010-092-42 A. WELL DATA *63+ PER GEG INSPECTION "WELL IS LOCATED INA PIT -SEE ATTACHED EMAIL FROM SULLIVAN WATER WELLS Well type PRIVATE If A, B, or C provide PWSID# N/A Well Log (Y/N) "NO Q Date completed 1960(?) Sanitary seal (Y/N) "YES Wires properly protected (Y/N) "YES �( Total depth '63+ ft. Cased to '•UNK ft. Casing height (above ground) "12+ in. FROM WELL LOG Date of test G Static water level Well production g.p.m. AT INSPECTION 3/22/2017 35.1 2.8+ g.p.m. WATER SAMPLE RESULTS: Coliform 0 colonies/100 ml. Nitrate ND mg./L. Collected by: GEG, Ltd. Arsenic: 35.9 ug./L. Date of sample: 3/22/2017 B. SEPTIC/HOLDING TANK DATA PUBLIC SEWER Tank Type/Material Date installed Tank size gal. Number of Compartments Foundation cleanout (Y/N) _ Depression over tank (Y/N) Date of pumping Pumper C. ABSORPTION FIELD DATA Date installed Length ft. Total depth ft. Eff. Date of adequacy test Soil rating (g.p.d./Wor Width i Cleanouts (Y/N) High water alarm System type Gravel below pipe ft. ft' Monitoring tube_ Depression over field_ Results (Pass/Fail) For bedrooms Fluid depth in abso n field before test _ in. Elapsed _ min. Final fluid depth rejuvenation treatment (past 12 mo.) (Y/N & type) Water added _gal. New depth _in. in. Absorption rate >= g.p.d If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off" level at wa er alarm level at in. Cycles tested Meets alar & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot NIA Absorption field on On adjacent lots 100'* On adjacent lots 100'+ Public sewer main -'u+ Public sewer manhole/cleanout "50'+ Sewer /septic service line ""20'+ Holding tank 75'+ Animal containment areas 50'+ Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: PUBLIC SEWER Building foundation Water main Wells on adjacent lots Property line Water service I SEPARATION DISTANCE FROM ABSORPTION FI Property line Water service line F. COMMENTS Surface water Wells on adjacent lots Absorption field Surface water TO: Water main Driveway, parking/vehicle storage 'CODE AT TIME OF INSTALLATION "ASSUMED PER CLEANOUT LOCATION SHOWN ON SURVEY G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date (Rev. 10112112) I #RLUUUb9 Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 Arsenic Advisory Certificate of On -Site Systems Approval # OSC171112 A Certificate of On -Site Systems Approval inspection and test of potable water was recently conducted on the well water supply on Block , Lot 12E-1 of Woodland Park Subdivision. This inspection revealed an arsenic concentration of 35.9 micrograms per liter (ug/L) for the property's well water sample. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 ug/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Information on arsenic is available from the On -Site Water and Wastewater Program website (www.muni.org/onsite) or at 343-7904. This advisory must be attached to all copies of the subject Certificate of On - Site Systems Approval. R 0-P.9ULLIVAN WATER WELLS Drilling • Piling • Pumps P.O. Box 670269 Chugiak, AK 99567 P: (907) 688-2759 F: (907) 688-2259 TO: Garness Engineering PROPERTY ADDRESS:2221 W. 34th Anchorage, AK (Woodland Park) David, Date: 3-30-17 We have completed the upgrade to the existing sump system. Upon testing the system by flooding the well pit, it turns on before any water reaches the well casing and any potential annular space. The pump turns off with roughly 1/4" of the water remaining; also well below the well casing. We replaced the split well seal with a similar, but watertight version as well. The camera revealed that the well has been lined. We were unable to view any portion of the 6" casing beyond 7 feet from top of casing. The wire to the pump was wrapped in a way that made sending the camera into the liner problematic. Thank you and please call with any questions. Regards, Cole Sullivan �� ry u•t No.r2004-11,1 ..- O _ 20IISIv N 88'25'31" E 50.5 71 I 170.80' r- LOT 12E-1 1 Story House N 89'55'54" E 142.38' � ao n ti I,n W. 34th Avenue (kck u m c I r 3 / o Storag\ Building L Basement Details Not To Scale Access 28 4.1"0 h 46.3' h td oI r .. 0 ^ 8.2 2 Story 0.6' House 2 j' \ „y� 16.7' h � Brick V io Chimney NN „ 15.2' Lf) Pi oZ • 21.7' w s� m CoFrnM Porch � 00 ,� $ , - –? ��. ' 5.7' h upper Deck N 1�p ����y 6.5' a O W 'L _ _� '.,., Greenhouse on O g ,.t, v Shed Beck Foundation to 10.8'YWYY1 Storage\ S 89'56'30" E o \� �d Buirdg18 16 6 Scall = 40' 71.14' N o � - N09BS I 1. Bearings and distances are record per re erenced plat unless otherwise noted. 2. Sufficient boundary evidence was recovered to establish the subject parcel on the ground. Not all controlling evidence is shown hereon. —SOF. LLC .:.(�oF•A�gy� Far�oint Land Services, 0 Monument ��P;'•tl SURVEYING, MAPPING. LAND PLANNING, GIS 'Wqq. 9`� ,.,,.. Septic Vent 1 131 E. 76th Ave., 5ulte 101 Anchorage, Alaska 99518 � Power pole *: — '.* �. 48TH � ..� FarpolntAK.com • (907) 522-7770 •survey@farpolntak.com p ASM II' SURVEY OI:: SURVEY CERTIFICATION: FARPOINT has conducted a physical ® Wat er Well CILot 12E-1, Block E, Woodland Park survey of the subject property, the improvements situated MICHAEL J. HORNE . o thereon are within the property lines as shown. Existing Fence • Subdivision, �rF9• LS -5318 JQ�i EXCLUSION NOTES: It is the owners responsibility to determine �lF�AOfESSb%K, �paDi� ORK ORDER�No oAAE Alaska suLe ZONE: the existence of any easements, covenants, or restrictions which Glacier City Realty ``������� Mar. 28, 2017 1 LE: R-1 do not appear on the Plat used for this survey. NOTE: Under no p.0. Box 550 17025 DRAWN: CHECKED: GRID No: FB BOOKIPAGE: Circumstances should any data hereon be used for construction Girdwood, AK 99587 1LA ME SW1628 134/34-35 or for the establishing of property lines. Pierce Blewett From: David Garness Sent: Wednesday, April 05, 2017 9:41 AM To: Pierce Blewett Subject: FW: 3309 Willow Ln. - Connect Records From: Curtis, Nick J. [mailto:Nick.Curtis@awwu.biz] Sent: Wednesday, April 5, 2017 9:03 AM To: David Garness Subject: RE: 3309 Willow Ln. - Connect Records David, I just checked and both lots are connected and served by our sewer system. We do not have water to either of the lots. Thank you, Nick Curtis Engineering Tech 11 Anchorage Water 8 Wastewater Utility Direct: 907-564-2708 Nick. Curtis(&awwu. biz Excellence Through Innovation www.awwu.biz ©0 From: David Garness[ma ilto:David (&garnessengineering.com] Sent: Wednesday, April 05, 2017 8:52 AM To: Curtis, Nick 1. Subject: RE: 3309 Willow Ln. - Connect Records Nick, Thank for the information. Could you also confirmed that they are connected and served. Could you also confirm that Woodland Park Lot 13E (2233 West 34Th Avenue) is served? I don't need the connect card, but just confirmed that they are both served. Thank you David Garness From: Curtis, Nick J. [mailto:Nick.Curtis@awwu.biz] Sent: Tuesday, April 4, 2017 3:53 PM To: David Garness Subject: 3309 Willow Ln. - Connect Records Hi David,